These symbols are intended to alert the user to the presence of
important operating and maintenance instructions in the manual
accompanying the appliance.
FOR YOUR SAFTEY
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN
THE VICINTIY OF THIS OR ANY OTHER APPLIANCE.
POST IN PROMINENT LOCATION
INSTRUCTIONS TO BE FOLLOWED IN THE EVENT USER SMELLS GAS. THIS
INFORMATION SHALL BE OBTAINED BY CONSULTING YOUR LOCAL GAS SUPPLIER.
AS A MINIMUM, TURN OFF THE GAS AND CALL YOUR GAS COMPANY AND YOUR
AUTHORIZED SERVICE AGENT. EVACUATE ALL PERSONNEL FROM THE AREA.
WARNING
IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE
CAN CAUSE PROPERTY DAMAGE, INJURY OR DEATH. READ THE INSTALLATION,
OPERATION & MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR
SERVICING THIS EQUIPMENT.
WARNING
RISK OF FIRE OR ELECTRIC SHOCK
DO NOT OPEN
WARNING, TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO NOT REMOVE
CONTROL PANEL. NO USER-SERVICABLE PARTS INSIDE.
REPAIRS SHOULD BE DONE BY AUTHORIZED SERVICE PERSONNEL ONLY.
NOTICE
Using any part other than genuine Lang factory supplied parts relieves the manufacturer of all
liability.
Star reserves the right to change speci cations and product design without notice. Such
revisions do not entitle the buyer to corresponding changes, improvements, additions or
replacements for previously purchased equipment.
Due to periodic changes in designs, methods, procedures, policies and regulations, the
speci cations contained in this sheet are subject to change without notice. While Star
Manufacturing exercises good faith efforts to provide information that is accurate, we are
not responsible for errors or omissions in information provided or conclusions reached as a
result of using the speci cations. By using the information provided, the user assumes all risks
in connection with such use.
MAINTENANCE AND REPAIRS
Contact your local dealer for service or required maintenance. Please record the model number, serial
number, voltage and purchase & Installation Information in the area below and have it ready when you
call to ensure a faster service.
SAFETY SYMBOL
Model No.:
Serial No.:
Voltage:
1-Phase or 3 Phase:
Purchased From:
Location:
Purchase Date:
Installed Date:
2
PROBLEMS, QUESTIONS or CONCERNS
Before you proceed consult you authorized Lang service agent directory
or
Call the Lang Technical Service & Parts Department at 1-800-807-9054.
personnel only. Consult your Lang Authorized Service Agent Directory.
You can call our toll free number 1-800-807-9054 or visit our website
WWW.STAR-MFG.COM for the service agent nearest you.
3
W
D
H
4” (101.6mm)
2.5”
Elec. Connect.
6.8”
Elec. Connect.
36”
Elec. Connect.
(160 & 172 only)
IL1547
EQUIPMENT SPECIFICATIONS
Height x Width x DepthClearance from Weight
Model
124
136
148
160
172
15.0" x 24.0" x 28.2"243 lbs.280 lbs.
381mm x 610mm x 717mm110 kg127 kg
15.0" x 36.0" x 28.2"368 lbs.410 lbs.
381mm x 914mm x 717mm167 kg186 kg
15.0" x 48.0" x 28.2"Sides: 2"483 lbs.515 lbs.
381mm x 1219mm x 717mmBack: 2"220 kg234 kg
15.0" x 60.0" x 28.2"621 lbs.665 lbs.
381mm x 1524mm x 717mm282 kg302 kg
15.0" x 72.0" x 28.2"724 lbs.800 lbs.
381mm x 1830mm x 717mm329 kg364 kg
Freight Class(Not including legs)combustible surfaceActualShipping
MARINE EQUIPMENT IS APPROVED FOR INSTALLATION ONLY ON VESSELS GREATER
THAN 65 FEET IN LENGTH, IN ACCORDANCE WITH USCG REGULATIONS IN TITLE 46
CFR 110-113.
ANY WIRING USED IN THE INSTALLATION OF THIS APPLIANCE MUST BE STRANDED
COPPER.
5
EQUIPMENT DESCRIPTION
1” Griddle Surface
Gutter
Legs
Grease Pan
Section
Temp. Dial
Main Section
Power Switch
Section
Power Switch
Rear Gutter
(certian models)
IL1548
Exterior Construction
The griddle dimensions are 17” (43.18cm) High, 30” (76.20cm) Deep, and width is dependent on the
actual model number.
The Sides, Bottom, and Rear wall are constructed of double wall stainless steel, which allows closer
installation to combustible surfaces.
The griddle surface is made of 1” thick, highly polished steel to reduce hot and cold spots, recovery
problems, warping, and ensure even heat to the edges of the griddle.
Controls
Each twelve-inch section has its own temperature selector switch that snaps into place to lock in any
temperature from 175°F to 450°F (79°C to 232°C) in 25° increments.
Each twelve-inch section of the griddle is controlled by an area sensitive RTD probe, which can sense
and react to a temperature change of +/- 4°F.
Each twelve-inch section has a set of 6 K.W. elements for high efciency, quick recovery and outstanding
performance
Technical
The 100 Series Selectronic griddle operates on either 208/240V or 480V, at either single or three phase.
Thismustbespeciedwhenordering.
Minimum clearances: 2” from side and back
NOTICE The data plate is on the right side of the griddle. The oven voltage,
on the data plate. This information should be carefully read and
understood before proceeding with the installation.
6
CAUTION
UNPACKING
Receiving the Griddle
Upon receipt, check for freight damage, both visible and concealed.
Visible damage should be noted on the freight bill at the time of delivery and
signed by the carrier’s agent. Concealed loss or damage means it does not
become apparent until the merchandise has been unpacked. If concealed
loss or damage is discovered upon unpacking, make a written request for
inspection by the carrier’s agent within 15 days of delivery. All packing
material should be kept for inspection. Do not return damaged
merchandise to Star Manufacturing Company. File your claim with the
carrier.
Location
Prior to un-crating, move the oven as near to its intended location as practical. The crating will help
protect the unit from the physical damage normally associated with moving it through hallways and
doorways.
Un-crating
The griddle will arrive completely assembled inside a wood frame and strapped to a skid. Cut the
straps and remove the wood frame.
The oven can now be removed from the skid.
THE UNIT IS EXTREMELY HEAVY. FOR SAFE HANDLING, INSTALLER
SHOULD OBTAIN HELP AS NEEDED, OR EMPLOY APPROPRIATE MATERIALS
HANDLING EQUIPMENT (SUCH AS A FORKLIFT, DOLLY, OR PALLET JACK)
TO REMOVE THE UNIT FROM THE SKID AND MOVE IT TO THE PLACE OF
INSTALLATION.
ANY STAND, COUNTER OR OTHER DEVICE ON WHICH OVEN WILL BE
LOCATED MUST BE DESIGNED TO SUPPORT THE WEIGHT OF THE GRIDDLE.
SHIPPING STRAPS ARE UNDER TENSION AND CAN SNAP BACK WHEN CUT.
7
INSTALLATION
IL1549
Std Leg
Marine Bolt Down Leg
2.5”
IL1550
Above: typical leg installation.
Leg Installation
There are four, 4” legs provided for 2, 3 and
4 foot griddles.
There are eight 4” legs provided for 5 and 6
foot griddles.
The legs are shipped in the grease drawers
of the griddle. Install them into the threaded
holes on the underside of the griddle body.
Leveling adjustment may be done by screwing the bottom portion of the leg in and out.
For bolt down legs see above illustration for dimensions.
DANGER: THIS APPLIANCE MUST BE GROUNDED AT THE TERMINAL PROVIDED.
FAILURE TO GROUND THE APPLIANCE COULD RESULT IN ELECTROCUTION
AND DEATH.
INST
ALLATION OF THE UNIT MUST BE DONE BY PERSONNEL QUALIFIED TO
WORK WITH ELECTRICITY AND PLUMBING. IMPROPER INSTALLATION CAN
WARNING
CAUSE INJURY TO PERSONNEL AND/OR DAMAGE TO EQUIPMENT. UNIT
MUST BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE CODES.
NOTICE: The data plate is located behind access panel between controls and grease
drawer. The grill voltage, wattage, serial number, wire size, and clearance
specicationsareonthedataplate.Thisinformationshouldbecarefully
read and understood before proceeding with the installation.
NOTICE: The installation of any components such as a vent hood, grease extractors,
KEEP FLOOR IN FRONT OF EQUIPMENT CLEAN AND DRY. IF SPILLS
CAUTION
OCCUR, CLEAN IMMEDIATELY, TO AVOID THE DANGER OF SLIPS OR FALLS.
8
INSTALLATION cont.
Ventilation and Clearances
Standard minimum clearance from combustible construction is as follows.
2” from side
2” from back
These griddles may be set directly, without legs, on a curbed base or non-combustible surface.
If the griddle is set without legs on a non-combustible oor or a curbed base, maintain a 4-inch
back clearance.
Do not install the griddle directly against a non-combustible back wall or surface.
Do not install the griddle closer than 12 inches from an uncontrolled heat source (char broiler etc.).
Keep the appliance area free and clear of combustible material and do not obstruct the ow of
combustion or ventilation air.
Electrical Connection
There is one power supply connection on the 2, 3, and 4-foot griddles. There are two power
supply connections on 5 and 6-foot griddles. Refer to the power supply chart in the Technical
Data portion of this manual, for proper power supply size.
There is (1) one 1 1/4-inch conduit knockout on 2, 3 and 4-foot griddles located at the rear of the
griddle, through the back and the bottom of the griddle body. There are (2) two 1 1/4-inch conduit
knockouts provided on the 5 and 6-foot griddles. Use a supply wire suitable for at least 90 degree
centigrade.
This Selectronic griddle is shipped from the factory, wired for 208/240 or 480 volts, the 208/240
griddle is a dual voltage design. Jumper wires on terminal strip next to the main power supply
connection determine the griddle voltage. For a 208-volt power supply, leave the jumpers in place.
For a 240-volt power supply disconnect the jumpers as indicated on the tag on the terminal strip.
The 480-volt griddle can be operated on 480 volts only and must be specied when ordering.
All griddles are shipped from the
factory set up for a three-phase
service. Rearrange the wires in
the power supply terminal block to
convert the griddle to single phase.
Re-phasing the griddle is not
chargeable to Lang Manufacturing
Company as warranty. To convert
to single-phase have a Lang
Authorized Service Agent, follow
this chart.