Lang PBF12G, PBF12S, PBF14G, PBF14S, PBF24G Operation Manual

...
TWO SIDED
GRILLS
MODEL
PBF12G, PBF12S PBF14G, PBF14S
PBF24G, PBF24S, PBF24SG
Installation and
Operation
2M-W1448 Rev. A 1/4/10
PBF12G
1
These symbols are intended to alert the user to the presence of important operating and maintenance instructions in the manual accompanying the appliance.
FOR YOUR SAFTEY
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN
THE VICINTIY OF THIS OR ANY OTHER APPLIANCE.
POST IN PROMINENT LOCATION
INSTRUCTIONS TO BE FOLLOWED IN THE EVENT USER SMELLS GAS. THIS
INFORMATION SHALL BE OBTAINED BY CONSULTING YOUR LOCAL GAS SUPPLIER.
AS A MINIMUM, TURN OFF THE GAS AND CALL YOUR GAS COMPANY AND YOUR
AUTHORIZED SERVICE AGENT. EVACUATE ALL PERSONNEL FROM THE AREA.
WARNING
IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE
CAN CAUSE PROPERTY DAMAGE, INJURY OR DEATH. READ THE INSTALLATION,
OPERATION & MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR
SERVICING THIS EQUIPMENT.
WARNING
RISK OF FIRE OR ELECTRIC SHOCK
DO NOT OPEN
WARNING, TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO NOT REMOVE
CONTROL PANEL. NO USER-SERVICABLE PARTS INSIDE. REPAIRS SHOULD BE DONE BY AUTHORIZED SERVICE PERSONNEL ONLY.
NOTICE
Using any part other than genuine Lang factory supplied parts relieves the manufacturer of all liability.
Star reserves the right to change speci cations and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions or replacements for previously purchased equipment.
Due to periodic changes in designs, methods, procedures, policies and regulations, the speci cations contained in this sheet are subject to change without notice. While Star Manufacturing exercises good faith efforts to provide information that is accurate, we are not responsible for errors or omissions in information provided or conclusions reached as a result of using the speci cations. By using the information provided, the user assumes all risks in connection with such use.
MAINTENANCE AND REPAIRS
Contact your local dealer for service or required maintenance. Please record the model number, serial number, voltage and purchase & Installation Information in the area below and have it ready when you call to ensure a faster service.
SAFETY SYMBOL
Model No.:
Serial No.:
Voltage:
1-Phase or 3 Phase:
Purchased From:
Location:
Purchase Date:
Installed Date:
2
PROBLEMS, QUESTIONS or CONCERNS
Before you proceed consult you authorized Lang service agent directory
or
Call the Lang Technical Service & Parts Department at 1-800-807-9054.
TABLE OF CONTENTS
Installation
General Installation Data . . . . . . . . . . . . . . . . . . . . . 4
Ventilation & Clearence . . . . . . . . . . . . . . . . . . . . . . 4
Electrical Electrical
Specications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Initial
Start-Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Seasoning The Setting Daily
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
General
Operating Hints & Saftey . . . . . . . . . . . . . . . . . . . . . 6
Monthly T
op Housing Maintenance . . . . . . . . . . . . . . . . . . . . . 6
Maintenance
Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Wiring
PBF12 & PBF14 208/240VAC . . . . . . . . . . . . . . . . . . . 8
PBF24 Exploded
Connection . . . . . . . . . . . . . . . . . . . . . . . 4
Grounding Instructions . . . . . . . . . . . . . . . . . 4
Cooking Surface . . . . . . . . . . . . . . . . . . . 5
the Temperature . . . . . . . . . . . . . . . . . . . . . . . . 5
Operation & Programming
Lubrication / Inspection . . . . . . . . . . . . . . . . . . 6
Diagram
240V . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
View & Parts List . . . . . . . . . . . . . . . . . . . . . 10-13
NOTICE Service on this or any other Lang appliance must be performed by quali-
ed personnel only. Consult your Lang Authorized Service Agent Direc­tory.
You can call our toll free number 1-800-807-9054 or visit our website
WWW.STAR-MFG.COM for the service agent nearest you.
3
CAUTION
GENERAL INSTALLATION DATA
This equipment is designed and sold for commercial use only by personnel trained and experienced in its operation and is not sold for consumer use in and around the home nor for use directly by the general public in food service locations.
All shipping containers should be checked for freight damage both visible and concealed. This unit has been tested and carefully packaged to insure delivery of your unit in perfect condition. If equipment is received in damaged condition, either apparent or concealed, a claim must be made with the delivering carrier.
Concealed damage or loss - if damage or loss is not apparent until after equipment is unpacked, a request for inspection of concealed damage must be made with carrier within 15 days. Be certain to retain all contents plus external and internal packaging materials for inspection. The carrier will make an inspection and will supply necessary claim forms.
VENTILATION AND CLEARANCES
The installation of any components such as a vent hood, grease extractors, and/or re extinguishing
systems, must conform to their applicable nationally recognized installation standards and/or local building codes.
ELECTRICAL CONNECTION
Before making any electrical connection be sure to read data plate which is located at the bottom of the unit.
ELECTRICAL GROUNDING INSTRUCTIONS
This unit is equipped with a 3-prong (grounding) plug for your protection against shock hazard and must be plugged directly into a properly grounded 3-prong receptacle.
WARNING
DO NOT CUT OR REMOVE THIS PLUG OR GROUNDING PRONG FROM THE PLUG.
CONNECT/PLUG UNIT INTO DEDICATED A.C. LINE ONLY SPECIFIED ON THE DATA
PLATE OF THE UNIT.
4
ELECTRICAL SPECIFICATIONS
C
D
B
A
A
IL1874
Model Voltage Rated Wattage Amps Cord Length Plug Type
PBF12(G,S) 120V/1-Ph 1400W 11.6 72” NEMA 5-15P PBF14(G,S) 120V/1-Ph 1800W 15.0 72” NEMA 5-15P (5-20P*) PBF24(G,S,SG) 208/240V 1-Ph 2700/3600W 13/15 72” NEMA 6-20P
* Canadian Requirment
PBF12(G,S)
PBF14(G,S)
PBF24(G,S,SG)
WARNING
Weight
45 lbs. 50 lbs
Freight
ClassActual Shipping
85
Model Height (D) x Width (A) x Depth (B)
21.8” x 15.75” x 19.9”
554mm x 400mm x 506mm 20.4 kg 22.7 kg
21.8” x 19.75” x 19.9” 60 lbs. 65 lbs.
554mm x 502mm x 506mm 27.2 kg 29.5 kg
21.8” x 28.75” x 19.9” 80 lbs. 85 lbs.
554mm x 730mm x 506mm 36.3 kg 38.6 kg
Clearance from
combustible surface
Sides: 0”, Back 0”
CONNECT/PLUG UNIT INTO DEDICATED A.C. LINE ONLY SPECIFIED ON THE DATA PLATE OF THE UNIT.
INITIAL START UP
Level unit using the adjustable feet under the unit (approximately 1/2" adjustment).
Before using the unit for the rst time, wipe down the exterior and grilling area with a damp cloth. Take
to
a well ventilated area and heat for approximately 30 minutes. The grill may emit a small amount of smoke as the cooking surfaces reaches 450°F. Do not be alarmed, as the smoke is caused by oils associated with the manufacturing process and will stop when the burn off is complete. Brush off any debris from the grilling surface.
5
Loading...
+ 11 hidden pages