These symbols are intended to alert the user to the presence of
important operating and maintenance instructions in the manual
accompanying the appliance.
FOR YOUR SAFTEY
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN
THE VICINTIY OF THIS OR ANY OTHER APPLIANCE.
POST IN PROMINENT LOCATION
INSTRUCTIONS TO BE FOLLOWED IN THE EVENT USER SMELLS GAS. THIS
INFORMATION SHALL BE OBTAINED BY CONSULTING YOUR LOCAL GAS SUPPLIER.
AS A MINIMUM, TURN OFF THE GAS AND CALL YOUR GAS COMPANY AND YOUR
AUTHORIZED SERVICE AGENT. EVACUATE ALL PERSONNEL FROM THE AREA.
WARNING
IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE
CAN CAUSE PROPERTY DAMAGE, INJURY OR DEATH. READ THE INSTALLATION,
OPERATION & MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR
SERVICING THIS EQUIPMENT.
WARNING
RISK OF FIRE OR ELECTRIC SHOCK
DO NOT OPEN
WARNING, TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO NOT REMOVE
CONTROL PANEL. NO USER-SERVICABLE PARTS INSIDE.
REPAIRS SHOULD BE DONE BY AUTHORIZED SERVICE PERSONNEL ONLY.
NOTICE
Using any part other than genuine Lang factory supplied parts relieves the manufacturer of all
liability.
Star reserves the right to change speci cations and product design without notice. Such
revisions do not entitle the buyer to corresponding changes, improvements, additions or
replacements for previously purchased equipment.
Due to periodic changes in designs, methods, procedures, policies and regulations, the
speci cations contained in this sheet are subject to change without notice. While Star
Manufacturing exercises good faith efforts to provide information that is accurate, we are
not responsible for errors or omissions in information provided or conclusions reached as a
result of using the speci cations. By using the information provided, the user assumes all risks
in connection with such use.
MAINTENANCE AND REPAIRS
Contact your local dealer for service or required maintenance. Please record the model number, serial
number, voltage and purchase & Installation Information in the area below and have it ready when you
call to ensure a faster service.
SAFETY SYMBOL
Model No.:
Serial No.:
Voltage:
1-Phase or 3 Phase:
Purchased From:
Location:
Purchase Date:
Installed Date:
2
PROBLEMS, QUESTIONS or CONCERNS
Before you proceed consult you authorized Lang service agent directory
or
Call the Lang Technical Service & Parts Department at 1-800-807-9054.
personnel only. Consult your Lang Authorized Service Agent Directory. You
can call our toll free number 1-800-807-9054 or visit our website
WWW.STAR-MFG.COM for the service agent nearest you.
3
SPECIFICATIONS
30.2”
766mm
25.3”
643mm
28.0”
711mm
56.0”
1422mm
25.3”
642mm
25.3”
642mm
20.8”
529mm
28.0”
711mm
25.3”
642mm
3.0”
76mm
Electrical
Connection
28.0”
711mm
30.2”
766mm
STAND OPTIONAL
Front Side ViewTop ViewRight Side View
IL1432
Model Height x Width x Depth Clearance from Weight
(without optional stand) combustible surface Installed Shipping Freight Class
ECOH-C 25.3” x 30.2” x 25.3” Side:6”, Back: 6”, Floor: 6” 185 lbs. 225lbs 85
642mm x 766mm x 643mm (84 kg) (102 kg)
UTILITY REQUIREMENTS
Model Number
Current ModelPrevious ModelVoltsHzMotor AmpsPhaseKW
and understood before proceeding with the installation.
5
CAUTION
UNPACKING
Receiving the Oven
Upon receipt, check for freight damage, both visible and concealed.
Visible damage should be noted on the freight bill at the time of delivery and
signed by the carrier’s agent. Concealed loss or damage means it does not
become apparent until the merchandise has been unpacked. If concealed
loss or damage is discovered upon unpacking, make a written request for
inspection by the carrier’s agent within 15 days of delivery. All packing material should be kept for inspection. Do not return damaged merchandise to
Star Manufacturing Company. File your claim with the carrier.
Location
Prior to un-crating, move the oven as near to its intended location as practical. The crating will help
protect the unit from the physical damage normally associated with moving it through hallways and
doorways.
Un-crating
The oven will arrive completely assembled inside a wood frame and strapped to a skid. Cut the
straps and remove the wood frame.
The oven can now be removed from the skid.
THE UNIT IS EXTREMELY HEAVY. FOR SAFE HANDLING, INSTALLER SHOULD
OBTAIN HELP AS NEEDED, OR EMPLOY APPROPRIATE MATERIALS
HANDLING EQUIPMENT (SUCH AS A FORKLIFT, DOLLY, OR PALLET JACK) TO
REMOVE THE UNIT FROM THE SKID AND MOVE IT TO THE PLACE OF
INSTALLATION.
ANY STAND, COUNTER OR OTHER DEVICE ON WHICH OVEN WILL BE
LOCATED MUST BE DESIGNED TO SUPPORT THE WEIGHT OF THE OVEN.
SHIPPING STRAPS ARE UNDER TENSION AND CAN SNAP BACK WHEN CUT.
6
INSTALLATION
IL1430
16” or 28”
Stand
4” Leg
Cardboard
Leg
Mounting Hole
IL1431
Alignment Pins
pn: 2C-20108-11
Alignment Hole
Leg Installation
4” legs are available for single
countertop installations. Single and
double deck installations require
16” or 28” stand installation, casters
may also be used in certain situations.
To install the 4” legs, place some
cardboard on the oor and gently tip
the unit onto its back. Fasten the
four, 4” legs into the threaded holes
located on the bottom of the unit.
Gently lift the oven into its operating
position.
16” & 28” stand installation, after
following the assembly
instructions that were provided with
the stand, gently lower unit on to
some cardboard as shown here.
Align the stand with the bottom of
the unit and secure with the
hardware provided. With the
assistance of carefully raise the unit
to its vertical position.
Stacking the Ovens
Two alignment pins (pn:2C-20108-11) are
needed if you intend on stacking two ECOH-C
on each other as shown. These pins must be
requested at the time of purchase, or call your
Lang authorized service agent, or Lang parts
department at 1-800-807-9054.
Having completed the previous step remove
any and all button plugs from the lower unit, so
the upper unit will lay properly.
Lay the upper unit on its back and screw the
alignment pins into the two rear holes.
With assistance lift the upper unit onto the lower
unit, being certain that the alignment pins go
into the alignment holes, as shown here.
NOTE: Each unit must have separate
electrical connections
7
Screw (2x)
Screw (2x)
Oven Top
Vent Flange
Vent Cover
IL1423
INSTALLATION continued
Vent Cap
Certian units come equipped with a vent cap assembly, this gets installed on top of the unit as shown
here. If your unit does not come equipped with this feature call the Lang parts department
at 1-800-907-9054 to inquire.
This vent allows:
heat to escape from the electronic controls and motor assemlby more freely, allowing
cooler air to enter through the side.
reduces the possiblitiy of blocking the vent or having objects or moisture falling into the
controls & motor compartment possibly damaging sensitive electronic components.
Install Vent Cap
1. Unit should be turned off.
2. Align vent ange with mounting holes on top of the unit as shown here.
3. Secure in place with hardware provided.
4. Align the mounting holes on the vent cover, with the holes on the vent ange, and secure with
hardware provided.
Vent Cap Assembly Installation, standard with certain models
8
INSTALLATION continued
Ventilation and Clearances
Standard minimum clearance from combustible construction is as follows.
4” from side
4” from back
6” from oor
• These ovens may be set directly, without legs, on a curbed base or non-combustible oor.
• If the oven is set without legs on a non-combustible oor or a curbed base, maintain a 4-inch back
clearance.
• If the oven is set directly against a non-combustible back wall, maintain a 6-inch clearance to the
oor.
• Do not install the oven closer than 4 inches from another oven on the right hand side (control panel
side).
• Do not install the oven closer than 12 inches from an uncontrolled heat source (char broiler etc.) on
the right side.
• Keep the area free & clear of combustible material, and do not obstruct the ow of combustion or
ventilation air.
• The installation of any components such as a vent hood, grease extractors, and/or re extinguisher
systems, must conform to the applicable nationally recognized installation standards.
NOTICE The installation of any components such as a vent hood, grease
extractors,reextinguishersystems,mustconformtotheir
applicable National, State and locally recognized installation
standards.
WARNING
WARNING
Electrical Connection
The electrical connection must be made in accordance with local codes or in the absence of local codes
with NFPA No. 70 latest edition (in Canada use: CSA STD. C22.1).
The electrical service entrance is provided by a 1 1/4-inch knockout at the oven back directly behind the
control
compartment. A grounding lug is provided at the rear service entrance.
The ECOH-C-VCN can be purchased with a Cord & Plug kit (Part number 9Q-ECOH-CK). This kit
includes a 48” cord with a NEMA L15-30P plug. In stacked situations each units needs to have separate
cord & plug assemblies.
Oven Voltage
The Lang Model ECOH ovens can be operated on 208, 240-volt (single or three phase), or 480-volt
(three phase only) source. The Amp draw, KW rating, and phasing can be found in the wiring diagram
section of this manual.
THIS APPLIANCE MUST BE GROUNDED AT THE TERMINAL PROVIDED. FAILURE
TO GROUND THE APPLIANCE COULD RESULT IN ELECTROCUTION AND DEATH.
INSTALLATION OF THE UNIT MUST BE DONE BY PERSONNEL QUALIFIED TO
WORK WITH ELECTRICITY AND PLUMBING. IMPROPER INSTALLATION CAN
CAUSE INJURY TO PERSONNEL AND/OR DAMAGE TO EQUIPMENT. UNIT MUST
BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE CODES.
9
Loading...
+ 19 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.