Lang ECCOP-AP User Manual

Page 1
IL1519
ELECTRIC FULL SIZE
COMPUTERIZED
CONVECTION OVEN
ECOD-AP
ECOF-AP
Operation
Instructions
2M-W488 Rev. D 2/5/09
ECOF-AP
1
Page 2
These symbols are intended to alert the user to the presence of important operating and maintenance instructions in the manual accompanying the appliance.
FOR YOUR SAFTEY
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN
THE VICINTIY OF THIS OR ANY OTHER APPLIANCE.
POST IN PROMINENT LOCATION
INSTRUCTIONS TO BE FOLLOWED IN THE EVENT USER SMELLS GAS. THIS
INFORMATION SHALL BE OBTAINED BY CONSULTING YOUR LOCAL GAS SUPPLIER.
AS A MINIMUM, TURN OFF THE GAS AND CALL YOUR GAS COMPANY AND YOUR
AUTHORIZED SERVICE AGENT. EVACUATE ALL PERSONNEL FROM THE AREA.
WARNING
IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE
CAN CAUSE PROPERTY DAMAGE, INJURY OR DEATH. READ THE INSTALLATION,
OPERATION & MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR
SERVICING THIS EQUIPMENT.
WARNING
RISK OF FIRE OR ELECTRIC SHOCK
DO NOT OPEN
WARNING, TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO NOT REMOVE
CONTROL PANEL. NO USER-SERVICABLE PARTS INSIDE. REPAIRS SHOULD BE DONE BY AUTHORIZED SERVICE PERSONNEL ONLY.
NOTICE
Using any part other than genuine Lang factory supplied parts relieves the manufacturer of all liability.
Star reserves the right to change speci cations and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions or replacements for previously purchased equipment.
Due to periodic changes in designs, methods, procedures, policies and regulations, the speci cations contained in this sheet are subject to change without notice. While Star Manufacturing exercises good faith efforts to provide information that is accurate, we are not responsible for errors or omissions in information provided or conclusions reached as a result of using the speci cations. By using the information provided, the user assumes all risks in connection with such use.
MAINTENANCE AND REPAIRS
Contact your local dealer for service or required maintenance. Please record the model number, serial number, voltage and purchase & Installation Information in the area below and have it ready when you call to ensure a faster service.
SAFETY SYMBOL
Model No.:
Serial No.:
Voltage:
1-Phase or 3 Phase:
Purchased From:
Location:
Purchase Date:
Installed Date:
2
Page 3
PROBLEMS, QUESTIONS or CONCERNS
Before you proceed consult you authorized Lang service agent directory
or
Call the Lang Technical Service & Parts Department at 1-800-807-9054.
TABLE OF CONTENTS
Specications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Equipment Description .. Unpacking. .
Installation
Leg Installation ..
Leg Pad Adapter Installation .. . . . . . . . . . . . . . . . . . . .8
Stacking the Oven. Ventilation & Clearence.
Electrical Connection.. . . . . . . . . . . . . . . . . . . . . . . 11
Oven Voltage.
Initial Start-Up
Pre-Power On. .
Power On . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
General Operation & Programming
Control Panel..
Typical Operation Sequence.. . . . . . . . . . . . . . . . . . . 13
Hints & Suggestions.
Loading.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Maintenance
Cleaning.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
. . . . . . . . . . . . . . . . . . . . . . . . . . . 11
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
. . . . . . . . . . . . . . . . . . . . . . . .5
. . . . . . . . . . . . . . . . . . . . . . . . . .7
. . . . . . . . . . . . . . . . . . . . . . . . . 9
. . . . . . . . . . . . . . . . . . . . . .10
. . . . . . . . . . . . . . . . . . . . . . . . . .12
. . . . . . . . . . . . . . . . . . . . . . . . . . 13
. . . . . . . . . . . . . . . . . . . . . . . .14
Troubleshooting Symptoms / Possible Causes / T
Wiring Diagram
208/240VAC.
220V/308VAC 4 Wire & 240V/415VAC 4 Wire.. . . . . . . . . . 18
380V/480VAC. . . . . . . . . . . . . . . . . . . . . . . . . . . .19
Exploded View & Parts List . .
NOTICE Service
. . . . . . . . . . . . . . . . . . . . . . . . . . . .17
onthisoranyotherLangappliancemustbeperformedbyqualied
est. . . . . . . . . . . . . . . . .16
. . . . . . . . . . . . . . . . . . . .20-27
personnel only. Consult your Lang Authorized Service Agent Directory. You can call our toll free number 1-800-807-9054 or visit our website WWW.STAR-MFG.COM for the service agent nearest you.
3
Page 4
SPECIFICATIONS
15.1”
384mm
2.5”
54mm
ELECTRICAL
CONNECTION
2.5”
54mm
ELECTRICAL
CONNECTION
27.0”
687mm
0.9”
23mm
IL1520
Front View
Right Side View
Top View
W
H
D
Model Height x Width x Depth Clearance from Weight (without optional stand) combustible surface Installed Shipping Freight Class
ECOF 27.9” x 40.1” x 39.1” Side:6”, Back: 6”, Floor: 6” 380 lbs. 420lbs 70 708mm x 1019mm x 994mm (173 kg) (191 kg)
ECOD 27.9” x 40.1” x 46.0” Side:6”, Back: 6”, Floor: 6” 460 lbs. 500lbs 70 708mm x 1019mm x 1168mm (209 kg) (227 kg)
SPECIFICATIONS
Current Number Previous Model
208V
ECOD-AP ECCO-APXD-C
240V
Qty Hz.
1 2 1/3 23 1 GA. 8.8 8.8 5.5 4 GA. 1 1/3 11.5 6 GA. 4.2 3.7 3.7 10 GA. 2 1/3 23 2 GA. 7.8 7.8 7.3 4 GA.
ECOD-AP-480V ECCO-APXD-U 480V 1 60 3 11.5 15.6 15.6 10.5 14 GA.
VOLTS ACOven
208V
ECOF-AP ECCO-AP-C
240V
ECOF-AP-380V ECCO-AP-K 380V 1 50 3 11.5 19.7 19.7 12.2 12 GA. ECOF-AP-480V ECCO-AP-U 480V 1 60 3 11.5 15.6 15.6 10.5 14 GA.
ECOF-AP-M ECCO-AP-CM
ECOF-AP2/4FA ECCO-AP2/4FA 240/415V 1 50 3PH-4 WIRE 17.8 11.5 17.8 15.3 15.3 12 GA.
208V
240V
1 60 3.3 11.5 6 GA. 6.0 2.7 2.7 8 GA. 2 60 3.3 23 1 GA. 8.8 8.8 5.5 4 GA. 1 60 3.3 11.5 6 GA. 4.2 3.7 3.7 10 GA. 2 60 3.3 23 2 GA. 7.8 7.8 7.3 4 GA.
1 2 1/3 23 1 GA. 8.8 8.8 5.5 4 GA. 1 1/3 11.5 6 GA. 4.2 3.7 3.7 10 GA. 2 1/3 23 2 GA. 7.8 7.8 7.3 4 GA.
ECOF-AP380FA ECCO-AP-KFA 380V 1 50 3 11.5 19.7 19.7 12.2 12 GA. ECOF-AP440VM ECCO-AP-SM 440V 1 60 3 11.7 17.5 17.5 10.8 12 ECOF-AP480VM ECCO-AP-UM 480V 1 60 3 11.5 15.6 15.6 10.5 14
MOTOR
AMPS PHASE
50/60 3.3
50/60 3.3
AMPS 3PH /
NEUTRAL KW TOT.
SUPPLY
WIRE 1 PH L1 L2 L3
1/3 11.5 6 GA. 6.0 2.7 2.7 8 GA.
1/3 11.5 6 GA. 6.0 2.7 2.7 8 GA.
4
SUPPLY
WIRE 3 PH
Page 5
EQUIPMENT DESCRIPTION
W
Door Handle
Controls
Steam Valve
Cover
Motor Vent
Side Access
Panel
Blower Wheel
H
D
IL1521
Exterior Construction
The oven exterior dimensions are listed in the Specication Section. The Top, Front, Back, and Sides are constructed of heavy duty 430 stainless steel, with an attractive No. 4 nish.
The ovens simultaneous-opening heavy duty doors come standard with double pane windows.
The door handle is constructed of Stainless Steel and Phonolic Tubing.
The oven cavity is insulated with high temperature insulation for efciency and reduced heat loss.
Interior Construction
The ECOF oven cavity dimensions are 29” (72.5 cm) Wide, 20” (50.84 cm) High, 21” (53.38 cm) Deep..
The ECOD oven cavity dimensions are 29” (72.5 cm) Wide, 20” (50.84 cm) High, 27” (53.38 cm) Deep.
The interior of the oven is constructed of porcelainized stainless steel.
Operation
The ECOD-AP and ECOF-AP ovens are forced air convection ovens with a vented oven cavity.
The air is driven by a 1/3 HP fan motor.
Controls
Easy to use manual control knobs.
Solid state temperature sensing and controls.
Pulse and two-speed fan.
Technical
The ECOD-AP and ECOF-AP ovens come in voltages of 208/240V, 380V, 440V or 480V. .
This must be specied when ordering.
Floor space required is 48” (122.6 cm) wide, 44” (112.5 cm) deep.
The oven weighs 430 lbs.
NOTICE The data plate is on the back side of the oven above the power cord.
The oven voltage, wattage, serial number, wire size, and clearance
specicationsareonthedataplate.Thisinformationshould
be carefully read and understood before proceeding with the installation.
5
Page 6
CAUTION
UNPACKING
Receiving the Oven
Upon receipt, check for freight damage, both visible and concealed. .
Visible damage should be noted on the freight bill at the time of delivery and signed by the carrier’s agent. Concealed loss or damage means it does not become apparent until the merchandise has been unpacked. If concealed loss or damage is discovered upon unpacking, make a written request for
inspection by the carrier’s agent within 15 days of delivery. All packing .
material should be kept for inspection. Do not return damaged merchandise to Star Manufacturing Company. File your claim with the carrier.
Location
Prior to un-crating, move the oven as near to its intended location as practical. The crating will help protect the unit from the physical damage normally associated with moving it through hallways and doorways.
Un-crating
The oven will arrive completely assembled inside a wood frame and strapped to a skid. .
Cut the straps and remove the wood frame.
The oven can now be removed from the skid.
EACH UNIT WEIGHS 420 or 500 LBS. FOR SAFE HANDLING, INSTALLER SHOULD OBTAIN HELP AS NEEDED, OR EMPLOY APPROPRIATE MATERIALS HANDLING EQUIPMENT (SUCH AS A FORKLIFT, DOLLY, OR PALLET JACK) TO REMOVE THE UNIT FROM THE SKID AND MOVE IT TO THE PLACE OF INSTALLATION.
ANY STAND, COUNTER OR OTHER DEVICE ON WHICH OVEN WILL BE LOCATED MUST BE DESIGNED TO SUPPORT THE WEIGHT OF THE OVEN.
SHIPPING STRAPS ARE UNDER TENSION AND CAN SNAP BACK WHEN CUT.
6
Page 7
INSTALLATION
Rear
Support Assy
Front
Support Assy
Swivel Caster
Caster
Cardboard
IL1524
Stacked Units
Caster Sets
27” Leg Set (marine also)
27” Equipment Cart
6” Adj. Leg Sets
6” Adj. Bolt Down Leg Sets (marine only)
Accessory Options
Single Units
IL1525
Above: typical leg and caster installation. Below: accessory options, legs, casters & equipment carts sold
separately. Follow installation instructions with the each specic kit.
27” Leg Installation
With unit in position, fasten the two legs to the front corner pads then to the oven’s front corners
using the four 5/16 inch bolts provided in the leg kit. See leg pad adapter illustration to dermine
differences between front & rear support assemblies. .
Lift the oven onto its front legs and block the back up using one of the 27-inch legs set upside down in the center rear of the oven body. Install the third 27-inch leg onto the oven body on the control side rear. Gently lift the oven rear, remove the temporary support leg & install it on the last rear corner.
Leg Installation
Legs are available separately for both the single and double deck installations. Single deck installations require a 27-inch leg or
equipment cart. Double deck installations .
require 6-inch legs or casters. All these are available separately.
Place some cardboard on the ground and with assistance carefully lay the unit on its back. In stacked
The adjustable feet may be screwed in
or out as necessary to level the oven. A .
torpedo level placed on an oven rack will assist in leveling the oven.
Double-Stack Ovens
To install the 6-inch legs, adj. feet or casters on the lower unit, follow the Leg Pad instructions in the following section or in the instructions included with the leg pads.
Single Oven
To install 27” legs or cart to your unit, place the unit laying on its back onto a piece of cardborad. Be sure to read all instructions & follow the instructions provided with the kit.
7
Page 8
INSTALLATION cont.
D
E
E
E
E E E E
E
E
E
A A
A
B
B
B
B
A
C
D D D
C
C
C
OVEN BOTTOM
OVEN FRONT
IL1523
Above: Bottom on unit showing the placement of the leg adapters and their hole assignment.
labeled “B”. NOTE: There are two sets of “B” holes set at 90° from the each other. One set will create a left rear adapter and the other set will create a right rear adapter.
Install four 5/16-inch bolts through the caster base and the adapter holes labeled “B” then install .
5/16-inch nuts with lock washers and at washers.
Leg Pad Adapter
Identify the front and rear leg adapters (the front adapters have two threaded inserts, the rear has four). The leg adapters are included with each specic accessory kit.
Leg to Adapter Installation:
Install the leg’s threaded stud through the hole in the adapter labeled “C” with the bent ange of the adapter facing away from the leg.
Screw the 3/4-inch nut supplied in the
adapter kit onto the leg stud and tighten. .
Secure to oven using hardware provided.
Caster to Adapter Installation:
Place the swivel caster against the front leg
pad adapter with the ange of the adapter .
facing away from the caster.
Install the four 5/16 inch bolts through the caster base and the adapter holes labeled “A” then install the 5/16 inch nuts with washer and lock washers.
Place the rigid casters against the rear leg adapter with the ange of the adapter facing away from the caster.
Align the caster to the holes in the adapter
Adapter to Oven Installation:
Gently tip the oven onto its back. Place the front leg adapter into the front corers of the oven. The holes without the threaded inserts face the front of the oven and the ange on the adapter points toward the bottom of the oven.
The edge of the leg adapter with the threaded insert slips under the ange on the oven side, while the edge without the inserts sits on top of the threaded angle on the oven front.
Install two 3/8-inch bolts with lock washers and at washers through the front holes “D” in the leg adapter and into the threaded inserts on the oven.
Thread one 3/8-inch bolt with lock washer and at washer into the rear threaded hole labeled “E” on each of the leg adapters.
The forward threaded hole on the front leg adapter does not get a bolt installed.
Place the rear leg adapters into the rear corners of the oven so that the adapter is under the ange
of the oven side and back. . NOTE: If installing a caster place the adapter on the oven so that the casters roll forward.
Install for 3/8-inch bolts with lock washers and at washers through the holes labeled “E” in the ange of the oven and into the threaded inserts of the leg adapter.
8
Page 9
INSTALLATION cont.
Button Plugs
Bushing
Stacking Bolts
Upper Oven
Lower Oven
IL1526
Stacking the Ovens
Remove all the plug buttons from the top of the lower oven.
Remove the stacking kit from the oven compartment of one oven and install the 1 1/4-inch plastic bushing into the top of the lower oven.
Tip the top oven backwards and install two 3/8-inch socket head bolts, found in the stacking kit, into the two front leg holes that match the holes in the top of the lower oven. Install the socket head bolts with the heads of the bolt pointing away from the oven.
Lift the top oven and gently set on top of the lower oven so that the heads of the socket head bolts nest into the holes in the top of the lower oven.
NOTE: Each unit must have separate electrical connections
9
Page 10
INSTALLATION continued
Ventilation and Clearances
Standard minimum clearance from combustible construction is as follows.
4” from side
4” from back
6” from oor
• These ovens may be set directly, without legs, on a curbed base or non-combustible oor.
• If the oven is set without legs on a non-combustible oor or a curbed base, maintain a 4-inch back clearance.
• If the oven is set directly against a non-combustible back wall, maintain a 6-inch clearance to the oor.
• Do not install the oven closer than 4 inches from another oven on the right hand side (control panel side).
• Do not install the oven closer than 12 inches from an uncontrolled heat source (char broiler etc.) on the right side.
• Keep the area free & clear of combustible material, and do not obstruct the ow of combustion or ventilation air.
• The installation of any components such as a vent hood, grease extractors, and/or re extinguisher systems, must conform to the applicable nationally recognized installation standards.
NOTICE The installation of any components such as a vent hood, grease
extractors,reextinguishersystems,mustconformtotheir applicable National, State and locally recognized installation standards.
10
Page 11
INSTALLATION continued
208/240V
Transformer
208/240V
Jumper Location
Trim Piece
IL1593
Electrical Connection
The electrical connection must be made in accordance with local codes or in the absence of local codes with NFPA No. 70 latest edition (in Canada use: CSA STD. C22.1).
The electrical service entrance is provided by a 1 1/4-inch knockout in the bottom right front corner
of each oven, or at the oven back directly behind the control compartment. .
Grounding lugs are provided at both the front and rear service entrances.
The 208/240-volt oven is a dual voltage oven and is shipped from the factory as 208 volt. The oven must be eld converted to operate on a 240-volt power supply. To convert the oven to 240 volt,
remove the jumper wire located under the control compartment behind the bottom trim piece. .
As well as changing the transformer input wire to the 240V, color on the primary side of transformer (see illustration below).
With 380V, 440V & 480-volt installations check to be sure that the motor rotates in a clockwise direction as viewed from the front of the oven. To reverse the motor rotation, switch any two incoming power supply leads and recheck the rotation.
Supply wire size must be large enough to carry the amperage load for the number of ovens being
installed. Wire size information can be found on the oven DATA PLATE or in the specications .
section on page 4..
208/240V ovens can be installed on both single and three-phase supplies and is shipped from the
factory for three-phase. To phase the oven to match the power supply, follow the charts on the .
wiring diagram located at the back of the manual.
Certain units are provided with or can be purchased with a Cord & Plug kit . (Part number 9Q-ECOF-CK). This kit includes a 48” cord with a NEMA L15-50P plug and is
for 208/240V units ONLY. In stacked situations each units needs to have separate cord & plug assemblies.
WARNING
WARNING
Oven Voltage
The Lang Model ECOF & ECOD ovens can be operated on 208, 240-volt (single or three phase), or 380/440/480V (three phase only) source. The Amp draw, KW rating, and phasing can be found in specication section of this manual.
THIS APPLIANCE MUST BE GROUNDED AT THE TERMINAL PROVIDED. FAILURE TO GROUND THE APPLIANCE COULD RESULT IN ELECTROCUTION AND DEATH.
INSTALLATION OF THE UNIT MUST BE DONE BY PERSONNEL QUALIFIED TO WORK WITH ELECTRICITY AND PLUMBING. IMPROPER INSTALLATION CAN CAUSE INJURY TO PERSONNEL AND/OR DAMAGE TO EQUIPMENT. UNIT MUST BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE CODES.
Left: 208/240V Dual Volatage units are shipped as
208V and must be eld converted to 240V.
11
Page 12
INITIAL START UP
Pre-Power On
After the oven is installed and connected to power, prior to turning on, verify the following:
The doors open and close freely.
All racks are in the oven correctly.
All packing materials have been removed from the inside of the oven.
Power On
Once oven has been turned on verify that the blower wheel is spinning freely in a clockwise position and that the elements are heating properly.
Confi rm that both thermostat knob and timer knob move freely and that the timer beeps..
NOTICE During the fi rst few hours of operation you may notice a small
amount of smoke coming off the oven, and a faint odor from the smoke. This is normal for a new oven and will disappear after the rst few hours of use.INITIAL START UP
12
Page 13
Vent Knob
Power
Light
Pulse Fan
Hi/Low Speed Fan
Temperature Control
Timer
IL1527
General Operation & Programming
Convection ovens constantly circulate air over and around the product. This strips away the thin layer of moisture and cool air from around the product allowing heat to penetrate more quickly.
Cooking times can be shortened and cooking temperatures can be reduced.
To convert standard deck oven recipes, reduce the temperatrue 50° degrees and the time by 25%. .
Make minor adjustments as necessary.
Always weigh your product. This will give you a more consistent size, color and quality.
Check the product near the end of the initial cooking.
Do not open the oven door during baking, as this will change the baking characteristics of the oven and make it .
difcult to determine a nal program.
If the product is overdone on the outside and underdone on the inside, reduce the baking temperature.
If the product is pulling away from the edge of the pan, the temperature is too high or the cooking time too long.
A convection oven is a mechanical piece of equipment. The same control settings will always give the same results. If the results vary, problems may be because of changes in the product preparation.
ECOF-AP / ECOD-AP Control Panel
The Control panel consists of the following items. . Detailed operational descriptions are given later this .
section.
Vent Knob: When open, allows moisture to escape the cooking chamber, allowing a dryer bake. (ex: crispy fries)
Power: Turns the oven on and off Pulse Fan:.
Pulse Setting: Fan will only turn ON, when the oven is
calling for heat.
Fan Setting: Fan is on continuously, speed is
determined by the Hi/Low switch.
Hi/Low Speed Fan: Dual speed switch. Toggles the fan
between high & low speed.
Temperature Control: Allows temperature to be set in
25°F increments from 140°F to 450°F
Timer: Electronic on-hour timer with .
continuous beeper,
Typical Operation Sequence
Action Result
Turn Power Switch to ON Adjust temperature, between
140°F & 450°F and allow 20 minutes for preheating
Open oven door and insert product, set timer up to 60 minutes.
Timer beeps continuously when done.
Control panel heat call light comes on.
Oven begins heating
Timer begins counting down.
Product should now be done.
13
Page 14
General Operation & Programming cont.
Hints & Suggestions
Convection ovens constantly circulate air over and around the product. This strips away the thin layer of moisture and cool air from around the product allowing heat to penetrate more quickly.
Cooking times can be shortened and cooking temperatures can be reduced.
To convert standard deck oven recipes, reduce the temperature 50 degrees and the time by 25%. Make minor adjustments as necessary.
The lower the oven temperature the more even the bake.
Always weigh your product. This will give you a more consistent size, color and quality.
Check the product near the end of the initial cooking cycle by turning on the oven light and looking through the oven door windows.
Do not open the oven doors during baking as this will change the baking characteristics of the oven and make it difcult to determine a nal program.
If the product is overdone on the outside and underdone on the inside, reduce the baking temperature.
If the product is pulling away from the edge of the pan, the temperature is too high or the cooking time too long.
The convection is a mechanical piece of equipment. The same control settings will always give the same results. If the results vary, problems may be because of product preparation.
Opening the vent will to allow mositure to escape the cooking chamber during part or all of the cooking process. This will allow a more crispy product, example: french fries, sh, crispy crusts. Close the vent for dough products like cinnamon rolls, breads. This is something to experiment with to determine what is best for your specic menu.
Loading
Here are some things to remember when loading your oven.
• When loading and unloading the oven, stage products and racks so the oven door is opened for the
least amount of time.
• Be sure that racks are level within the oven.
• Bent or warped pans can greatly affect the evenness of the cook or bake.
• If using baker’s parchment, be sure the parchment does not blow over the product. That will create
an uneven bake.
• Load each shelf evenly. Spaces should be maintained equally between the pan and oven walls, front
and back.
• Do not overload pan’s this will create an uneven bake.
• For best baking results, load the oven from the center out during random loading.
ALWAYS KEEP THE AREA NEAR THE APPLIANCE FREE FROM
COMBUSTIBLE MATERIALS.
CAUTION
KEEP FLOOR IN FRONT OF EQUIPMENT CLEAN AND DRY. IF
SPILLS OCCUR, CLEAN IMMEDIATELY, TO AVOID THE DANGER OF SLIPS OR FALLS.
14
Page 15
MAINTENANCE
• Oven interiors should be wiped down daily and thoroughly cleaned weekly using warm water and mild detergent.
DO NOT use caustic cleaners.
• The appliance should be thoroughly checked at six-monthly intervals by a qualied technician . (heating unit, mechanical stability, corrosion...) with particular emphasis on all control and safety .
devices.
CLEANING
• Always start with a cold oven.
• The stainless exterior can easily be cleaned using stainless steel cleaner.
• Always follow the cleaner manufacturer’s instructions when using any cleaner.
• Care should be taken to prevent caustic cleaning compounds from coming in contact with the fan wheel.
• The oven racks, rack slides, may be cleaned outside the oven cavity using oven cleaner.
• Using any harsh chemicals will result in the removal of the ETC coating and etching of the . porcelain below it. The oven interior should only be cleaned using a mild soap and a non metal scouring pad. .
DO NOT use caustic cleaners.
• Always apply stainless steel cleaners when the oven is cold and rub in the direction of the metal’s grain.
KEEP WATER AND SOLUTIONS OUT OF CONTROLS. NEVER SPRAY OR HOSE
CONTROL CONSOLE, ELECTRICAL CONNECTIONS, ETC.
WARNING
MOST CLEANERS ARE HARMFUL TO THE SKIN, EYES, MUCOUS
MEMBRANES AND CLOTHING. PRECAUTIONS SHOULD BE TAKEN TO WEAR
CAUTION
RUBBER GLOVES, GOGGLES OR FACE SHIELD AND PROTECTIVE CLOTHING.
CAREFULLY READ THE WARNING AND FOLLOW THE DIRECTIONS ON THE
LABEL OF THE CLEANER TO BE USED.
NEVER LEAVE A CHLORINE SANITIZER IN CONTACT WITH STAINLESS STEEL
SURFACES LONGER THAN 10 MINUTES. LONGER CONTACT CAN CAUSE CORROSION.
15
Page 16
Troubleshooting
Symptoms & Possible Causes
The following are charts of Symptoms and Possible Causes to aid in diagnosing faults with your unit.
Refer to the symptoms column to locate the type of failure then to the Possible Cause for the items to be checked.
To test for a possible cause refer to test to identify test procedures. Test indicated with an “*” should be done by a Lang factory authorized service representative.
Symptoms Possible Cause
No power to cord outlet Oven unplugged from outlet
Power indicator is not lit
Oven will not heat
Oven motor will not run
Product burning
Product is under done
Failed Power cord or plug Failed power switch Failed indicator light Power Switch is not “ON” Failed Transformer Failed Probe Failed Circuit board Failed Contactor Failed Over-temperature Thermostat Failed Element Power Switch is not “ON” Failed Transformer Failed Contactor Failed Motor Product is cooked too long Failed Probe Failed Circuit board Product is not cooked long enough Failed Probe Failed Circuit board
Possible Cause Test
Product is cooked too long Failed Probe Check probe for proper resistance*
Failed Circuit board
Failed Transformer
Failed Contactor
Failed Motor Failed or disconnected safety
thermostat Failed Element
No test available, operational condition
Conrm that Circuit board is getting
correct voltage and putting out correct voltage*
Check both Primary and Secondary coils for correct voltage*
Remove the wires from the contactor coil and check for continuity across the contactor coil connection*
Ensure the contactor moveable points move freely up and down*
Conrm that motor is getting correct
voltage* Check across the thermostat
connectors for continuity*
Conrm that Elements are getting
correct voltage and have continuity*
NOTICE If an item on the list is followed by an asterisk (*), the work should be done by
a Lang factory authorized service representative.
USE OF ANY REPLACEMENT PARTS OTHER THAN THOSE SUPPLIED BY
LANG OR THEIR AUTHORIZED DISTRIBUTORS CAN CAUSE BODILY INJURY
CAUTION
TO THE OPERATOR AND DAMAGE TO THE EQUIPMENT AND WILL VOID ALL WARRANTIES.
NOTICE ServiceonthisoranyotherLangappliancemustbeperformedbyqualied
personnel only. Consult your Lang Authorized Service Agent Directory. You can call our toll free number 1-800-807-9054 or visit our website WWW.STAR-MFG.COM for the service agent nearest you.
BOTH HIGH AND LOW VOLTAGES ARE PRESENT INSIDE THIS APPLIANCE
WHEN THE UNIT IS PLUGGED/WIRED INTO A LIVE RECEPTACLE. BEFORE
WARNING
REPLACING ANY PARTS, DISCONNECT THE UNIT FROM THE ELECTRIC POWER SUPPLY.
16
Page 17
HEAT
D
BUZZER
24
1 DECK
1 DECK
2 DECK
2 DECK
VOLTS
L1-L2 L2-L3 L3-L1 TOTAL L1 L2 L3 1 PH
KW AMPS
240
208
240
208
8
8.91
4.33
6.16
8
8.91
3.67
2.75
7.33
5.5
3.67
2.75
23.33
23.33
11.66
11.66
55.3
60
28.9
37
57.7
74.2
28.9
37
55.3
60
26.5
22.9
97.2
112
48.6
56
1,4,72 DECK 2,5,8 3.6 2,4,6,81,3,5,7
L1
1,41 DECK
L2 L3
2 3
THREE PHASE
L1 L2
2,41,3
SINGLE PHASE
SERVICE CONNECTIONS
SECOND DECK
WIRING IDENTICAL
FIRST DECK
123
4 8
765
CIRCUIT BREAKERS
SECOND DECK
TERMINAL BLOCK
12 POLE
GROUND LUG
CONTACTOR
FROM MAIN
FUSES #2
DISC-STAT
HIGH-LIMIT
SWITCH
2-SPEED
HEAT LIGHT
24VAC
CONTROL
C
ON
LIGHT
PULSE
C
TOP
24VAC
NC C NO
24VAC
TIMER
2345678
9
10
12
POSITION
SWITCH
RTD
543
2
1
1
-AP
16 BLU
15 BLK
14 RED
D
D
CONNECTOR
ARKLESS
30501-02
T-BLOCK
28 PRL
PRL
29 YEL
38 YEL
PULSE LAMP
PRL
26 YEL
46 BLK
XFMR
17 BLK
30701-05
41 BRN
40 BRN
21 WHT
19 RED
42 BRN
36 RED
47 YEL 48 YEL
31400-10
11 WHT
10 WHT
12 RED
BOTTOM
48 BLK
45 BLK
#1 TOP
45 BLK
13 WHT
18 RED
22 WHT
30203-16
30303-06
17
18
19
20
WHT
WHT
WHT
WHT
31800-01
32 BLU
7 BLU
6 WHT
5 RED
30700-06
59 BLU
58 BLU
RED
WHT
BLU
BLK
BLK
RED
WHT
BLU
11090-16
43 BRN
39 GRN
38 YEL
61 BLK
60 BLK
37 YEL
31601-07
63 BLK
30 GRN
31 BLU
29 YEL
27 GRN
30802-04
26 YEL
25 BLK
24 YEL
23 YEL
35 GRN
33 BLK
34 RED
40101-10
30304-16
30800-05
28 GRN
55 53 52 54
51 57 56 50
51 55 57 53 52 56 54 50
208V
JUMPER
T7-T4
T9
P1
NO
NCC
D
1
2
3
4 4
3
2
1
FUSE
FUSE
CONTACTOR
MAIN
24VAC
C D
B
240
LIGHT
240VAC
FROM MAIN CONTACTOR
BCD
M
DOOR SWITCH
OVEN LIGHTS
MOTOR
MOTOR
CIRCUIT BREAKERS
FIRST DECK
HEATING ELEMENT
TERMINALS
REAR VIEW
SWITCH
POWER
SWITCH
PULSE MODE
"HEAT"
FROM
REMOVE JUMPER FOR 240VAC
= WIRE NUT
3667W-240V2750W-208V
2750W-208V
2750W-208V
2750W-3667W
3667W-240V
3667W-240V
LO
HIGH
30200-17
19 RED
10 RED
21 WHT
10 WHT
REVISION BLOCK
ECN NO.REV DESCRIPTION DR: DATEMFG ENG
-AP CONTROL
12 RED
10 RED
11 WHT
13 WHT
TOP
BOTTOM
CNTR
TIE WRAP
FUSE MOUNT
ECCO-226
FUSE HOLDER
30901-08
FUSE
30900-10
Model: ECCO-AP, 208-240VAC
2M-6111-109, Rev. B, 12/14/94
17
Page 18
28 GRN
30800-05
30304-16
40101-10
34 RED
33 BLK
35 GRN
23 YEL
24 YEL
25 BLK
26 YEL
30802-04
27 GRN
29 YEL
31 BLU
30 GRN
63 BLK
31601-07
37 YEL
60 BLK
61 BLK
38 YEL
39 GRN
43 BRN
11090-16
BLU
WHT
RED
BLK
BLK
BLU
WHT
RED
10 RED
19 RED
30700-06
5 RED 6 WHT 7 BLU
32 BLU
WHT
WHT
WHT
20
19
18 17
30303-06
30203-16
22 WHT
18 RED
13 WHT
45 BLK
45 BLK
48 BLK
12 RED
10 WHT
11 WHT
31400-10
48 YEL47 YEL
36 RED
42 BRN
19 RED
21 WHT
40 BRN
41 BRN
30701-05
30200-17
17 BLK
XFMR
46 BLK
26 YEL
PRL
30900-10
FUSE
CNTR
BOTTOM
TOP
PULSE LAMP
38 YEL
29 YEL
PRL
28 PRL
T-BLOCK
30501-02
ARKLESS
CONNECTOR
D
D
HIGH
LO
14 RED
15 BLK
16 BLU
-AP
1
1
234
5
RTD
SWITCH
POSITION
12
10
9876543
2
TIMER
24VAC
NOCNC
24VAC
3667W-240V
3667W-240V
2750W-3667W
2750W-208V
2750W-208V
2750W-208V 3667W-240V
= WIRE NUT
TOP
C
FROM
PULSE
"HEAT"
LIGHT
PULSE MODE
ON
C
CONTROL
24VAC
HEAT LIGHT
2-SPEED
SWITCH
CONTROL
-AP
HIGH-LIMIT
DISC-STAT
SWITCH
POWER
SWITCH
FUSES
FIRST DECK
CIRCUIT BREAKERS
31800-04
MOTOR
OVEN LIGHTS
DOOR SWITCH
M
FROM MAIN
CONTACTOR
GROUND LUG
12 POLE
TERMINAL BLOCK
D
C
B
SECOND DECK
CIRCUIT BREAKERS
567
84
3
2
1
SECOND DECK
WIRING IDENTICAL
FIRST DECK
FROM MAIN CONTACTOR
240VAC
LIGHT
24
240
B
DC
24VAC
MAIN
CONTACTOR
FUSE
1
2
3
3
2
1
D
C NC
NO
P1
T9
T7-T4
BUZZER
D
HEAT
50545253575551
55 53 52 54
51 57 56 50
HEATING ELEMENT
TERMINALS
REAR VIEW
N
FUSE MOUNT
ECCO-226
13 WHT
12 RED
10 RED
FUSE HOLDER
30901-08
11 WHT
TIE WRAP
DWG. NO:
SHEET
OF
DESCRIPTION:
W/D ECCO-AP 220/308VAC 4 WIRE & 240/415VAC 4 WIRE
61111-173
REV:
1
A
1
VOLTS
L1-N L2-N L3-N TOTAL L1 L2 L3 Neutral
1 D E CK 220/380 3.10 3.10 3.10 9.30 14.1 14.1 14.1 14.1
1 D E CK 220/380 6.20 6.20 6.20 18.60 28.2 28.2 28.2 28.2
2 D E CK 240/415 3.70 3.70 3.70 11.10 15.4 15.4 15.4 15.4
2 D E CK 240/415 7.40 7.40 7.40 22.20 30.8 30.8 30.8 30.8
L1 L2 L3 N
1 D E CK 1 2 3 N
2 D E CK 1,4 2,5 3,6 N,N
KW AMPS
SERV ICE CONNE C TIO N S
18
Page 19
BRN
BRN
HI SPEED
T1
T3
T2
T1
T2 T3
L1
L3
L2
L1
L2
L3
NC
NC
LO SPEED
BLK
BLU
RED
NC
NC
D
D
BLACK
RED
BLUE
= WIRE NUT
2750W 480V
24 VAC
NOCNC
C
ON
PULSE
C
TIMER
-AP
1
1
234
5
12
POSITION
SWITCH
BUZZER
10
9876543
2
FROM MAIN
CONTACTOR
CONTACTOR
FROM MAIN
HI
LO
FROM
"HEAT"
PULSE
SWITCH
C
CONTROL
24VAC
HEAT LIGHT
CIRCUIT BREAKERS
CONTROL
-AP
SWITCH
POWER
FUSES
SWITCH
RELAY
LIGHT
DISC-STAT
M
4
5
6
1
6
2
4
3
5
L1
L2
L3
GROUND LUG
24 POLE
TERMINAL BLOCK
D
D
C
SECOND DECK
CIRCUIT BREAKERS
321
FIRST DECK
WIRING IDENTICAL
SECOND DECK
OVEN LIGHTS 240 VAC
480
24
D
LIGHT
CONTACTOR
MAIN
24VAC
FIRST DECK
MOTOR
FUSE
MOTOR
FUSE
1
2
33
2
1
DOOR SWITCH
D
C NC
NO
P1
T9
T7-T4
2 SPEED SWITCH
RTD
D
HEAT
5054565253575551
55 53 52 54
51 57 56 50
HEATING ELEMENT
TERMINALS
REAR VIEW
DWG. NO:
SHEET
OF
DESCRIPTION:
W/D ECCO-AP - 480,380 VAC
61111-110
REV:
1
D
1
L1-L2 L2-L3 L3-L1 TOTAL L1 L2 L3 1 PHA SE
1 DE CK 480 6.0 2.7 2.7 11.5 15.8 15.8 10.0 N/A
1 DE CK 380 6.0 2.7 2.7 11.5 19.7 19.7 17.2 N/A
2 DE CK 480 8.7 8.7 5.4 23.0 25.8 31.6 25.8 N/A
2 DE CK 380 8.7 8.7 5.4 23.0 23.0 39.5 32.1 N/A
L1 L2 L3 N/A N/A
1 DE CK 1 2 3 N/A N/A
2 DE CK 1-6 2-4 3-5 N/A N/A
AMPS
KW SERV ICE CONNECTIONS
3 P HAS E 1 P HAS E
VOLTS
19
Page 20
SK2366 Rev 4/21/2008
ECOF Main Assembly
1
5
7
6
1
2
3
4
8
9
10
11
13
16 1017
18
19
20 21
22
10
24
26 27 28
29
30
46
48
49
1
4
10
50
51
47
32 33
34
35
36
41
42 43
44 45
37 38
39
40
31
23 25
DetailA
Control Panel Assy
DetailB
Can Assembly
14
15
12
10
Page 21
PARTS LIST February 9, 2009, Rev. C
Model No: ECOF & ECOD Main Assembly
Commercial & Marine Full Size Electric Convection Oven
Key
Number
1 2C-20102-04 39 SCRW PHD ST 8-32X.5 PLTD ECOF-AP-380V, ECOF-AP-480V, ECOF-AP2/4FA, ECOF-AP380FA, ECOF-AP440VM, ECOF-AP480VM 2C-20102-04 40 SCRW PHD ST 8-32X.5 PLTD ECOF, ECOD 2 Q9-ECCO-230-1 1 TOP PANEL ASSEMBLY ECOF, ECOD 3 Q9-ECCO-176-2 1 BODY SPOTWELD STD. ECOF Q9-ECCO-177-3 1 BODY SPOTWELD DEEP ECOD 4 2P-70901-06 2 PLGBTNBLKPLSTC 5/8DP625 ECOF, ECOD 5 Q9-ECCO-176-4 1 STM VALVE COVER ECOF, ECOD 6 2C-20102-08 9 SCRW PHD ST 8-32X.375 ECOF, ECOD 2C-20102-08 13 SCRW PHD ST 8-32X.375 ECOF-AP-380V, ECOF-AP-480V, ECOF-AP2/4F ECOF-AP440VM, ECOF-AP480VM 7 Q9-60102-904 1 ACCESS COVER - ECCO/GCCO ECOF, ECOD 8 Q9-ECCO-124 1 TOP VENT SPOTWELD ECOF Q9-ECCO-124-1 1 ASSY - DEEP ECOD 9 Q9-ECCO-128 1 DAMPER BODY SPOTWELD ECOF, ECOD 10 2C-20103-02 3 SCRW SM PLT 10 X .5 PHLSL ECOF, ECOD 11 Q9-ECCO-182-3 1 BODY BACK S/S W/MOTOR ECOF, ECOD 12 Q9-ECCO-182-4 1 BODY BACK S/S COVER ECOF, ECOD 13 Q9-ECCO-133 1 DAMPER ROD B WELD ECOF, ECOD 14 Q9-ECO-437 1 DAMPER PIVOT ECOF, ECOD 15 2C-20602-02 2 TINNERMAN CLIP 1/4 ECOF, ECOD 16 2C-20301-20 1 NUT LOCK STOVER 1/4-20 ECOF, ECOD 17 Q9-ECCO-136 1 DAMPER BRACKET ANGLE ECOF, ECOD 18 2C-20104-41 6 SCRW MACH. 1/4-20X5/8 H/H ECOF, ECOD 19 Q9-ECCO-131 1 DAMPER ROD A WELD ECOF Q9-ECCO-131-1 1 DAMPER ROD WELD - DEEP ECOD 20 2C-20303-01 4 NUT HX SS 1/4-20 ECOF, ECOD 21 2R-70701-25 1 KNOB DAMPER BLACK PLAIN ECOF, ECOD 22 2E-31200-02 1 LUG GROUNDING UL APPROVED ECOF, ECOD 23 Q9-60102-99-1 1 BEARING BRACKET ASSY TOP ECOF, ECOD 24 2P-70201-07 2 BRNZ BR FLN 5/8IDX3/4ODX1 ECOF, ECOD 25 2C-20115-01 8 SCRW S/S 8-32X1/2 P/H S/T ECOF, ECOD 26 2C-20203-03 4 WSHR FLT SS 5/16 USS ECOF, ECOD 27 2C-20204-06 4 WSHR S/S 5/16 SPLIT LOCK ECOF, ECOD 28 2C-20111-07 4 SCRW SCKTHD 5/16-18X5/8 ECOF, ECOD 29 Q9-50312-43 1 RH DOOR ASSY E/GCCO ECOF, ECOD 29 Q9-50312-44 1 LH DOOR ASSY E/GCCO ECOF, ECOD 30 2C-71802-01 1 KEY WOODRUFF 3/16 X 5/8 ECOF, ECOD 31 2C-20201-15 5 WSHR FLT 960-C-1016 PLTD ECOF, ECOD 32 Q9-50312-67 1 PIVOT BEARING ASSY ECOF, ECOD 33 2P-73000-03 1 SST SPRKT40B11 5/8 BORE ECOF, ECOD 34 2C-20105-04 1 SCRW SET 1/4-20X1/2 ECOF, ECOD 35 2C-20301-07 1 NUT ACORN 1/4-20 PLTD ECOF, ECOD 36 2P-70201-06 2 BRNZBRFLN5/8IDX3/4ODX5/8 ECOF, ECOD 37 Q9-50312-41 1 BEARING BRACKET ASSY ECOF, ECOD 38 Q9-GCCO-185-4 2 HINGE BRACKET RETAINER ECOF, ECOD 39 2C-20115-01 4 SCRW S/S 8-32X1/2 P/H S/T PHDR ECOF, ECOD 40 2C-20111-07 4 SCRW SCKTHD 5/16-18X5/8 ECOF, ECOD 41 2C-20301-10 2 NUT HEX 6-32 PLTD ECOF, ECOD 42 2C-20102-12 2 SCRW PHD ST 10-32X3/8 ECOF, ECOD 43 Q9-ECCO-145-1 1 MICRO SWITCH BRACKET ECOF, ECOD 44 2E-30301-02 1 SWITCH, MICRO ECOF, ECOD 45 2C-20101-17 2 SCRW RND MS 6-32X1 PLTD ECOF, ECOD 46 2C-20104-50 2 SCRW HXHD 1/4-28X2-1/4 ECOF, ECOD 47 Y9-50312-05 1 HANDLE ASSY 1 HANDLE ECOF, ECOD 48 Q9-60102-1092 1 BOTTOM PANEL ECCO ECOF, ECOD
1
IMPORTANT: WHEN ORDERING, SPECIFY VOLTAGE OR TYPE GAS DESIRED PAGE
2
INCLUDE MODEL AND SERIAL NUMBER OF
Some items are included for illustrative purposes only and in certain instances may not be available.
Part
Number
Qty Per
Description
A, ECOF-AP380FA,
Star Manufacturing International, Inc.
Page 22
PARTS LIST June 30, 2008, Rev. C
Model No: ECOF & ECOD Main Assembly
Commercial & Marine Full Size Electric Convection Oven
Key
Number
49 Q9-ECCO-176-6 1 L/H BODY SIDE ECOF Q9-ECCO-177-1 1 L/H BODY SIDE - DEEP ECOD 50 2B-50200-93 2 RACK SLIDE 11 POS ECOF 2B-50200-94 2 RACK SLDE 11 POS E&GCCO-T ECOD 51 2B-50200-20 5 RACK ECCO/GCCO OVEN ECOF 2B-50200-31 5 RACK ECO DEEP OVEN ONLY ECOD
Part
Number
Qty Per
Description
2
IMPORTANT: WHEN ORDERING, SPECIFY VOLTAGE OR TYPE GAS DESIRED PAGE
2
INCLUDE MODEL AND SERIAL NUMBER OF
Some items are included for illustrative purposes only and in certain instances may not be available.
Star Manufacturing International, Inc.
Page 23
SK2353 Rev. A 4/25/08
Model: ECOF/D “ACCU-PLUS” Control Panel Assy Electric Full Size Convection Oven
32 6 7 119 14
16 19 20 24 26 28
Suggested Marine Parts Stocking
1
2
3
4
5
12
15
16
20
21
22
27
23
10
6
8
9
13
17
10
18
24
25
26
28
19
14
10
11
7
Detail A
Page 24
PARTS LIST June 30, 2008, Rev. C
Model No: ECOF-AP, & ECOD-AP CONTROLS PANEL
Commercial & Marine Full Size Electric Convection Oven
Key
Number
1 Q9-ECCOPAP-C 1 PANEL ECCO 208/240V ECOD-AP, ECOF-AP, ECOF-AP-M Q9-ECCOPAP-JFA 1 PANEL ECCO 380V ACCU-PLUS ECOF-AP2/4FA Q9-ECCOPAP-K 1 PANEL ECCO 380V ACCU-PLUS ECOF-AP-380V Q9-ECCOPAP-KFA 1 PANEL ECCO 380V ACCU-PLUS ECOF-AP380FA Q9-ECCOPAP-U 1 PANEL ECCO 480V ACCU-PLUS ECOD-AP-480V, ECOF-AP-380/480V, ECOF-
2 2R-70701-28 2R-70701-28 3 KNB BLK 1/4BUSH2SETSCW@90 ECCOPAP-JFA, ECCOPAP-KFA
3 2J-31601-01 1 PILOT LT 250V 6LEAD BLK ECCOPAP-JFA, ECCOPAP-KFA 2J-31601-07 2 PILOT LT 28V 6 LEAD WHT ECCOPAP-C, ECCOPAP-JFA, ECCOPAP-K,
4 2M-60301-100 1 PANEL LABEL- ECCOPAP-C, ECCOPAP-JFA, ECCOPAP-K,
2M-60301-120
5 Q9-50312-131 1 SPOT PANEL E & GCCO T & ECCOPAP-C, ECCOPAP-K, ECCOPAP-U Q9-50312-132 1 SPOT PANEL ECCO AP FAMOUS ECCOPAP-JFA, ECCOPAP-KFA
6 2E-30303-16 1 SWT TOG ON-ON BLK MOM ECCOPAP-C, ECCOPAP-JFA, ECCOPAP-K,
7 2E-30303-06 2 SWT TOG ON-ON DPDT BLK ECCOPAP-JFA, ECCOPAP-KFA 2E-30303-06 3 SWT TOG ON-ON DPDT BLK ECCOPAP-C, ECCOPAP-K, ECCOPAP-U 2E-30305-01 1 SWT INF 240V 15AMP ECCOPAP-JFA, ECCOPAP-KFA
8 2E-30304-16 1 CIR.BD.SWITCH 140’-450’F ECCOPAP-C, ECCOPAP-JFA, ECCOPAP-K,
9 Q9-30800-05-11 1 TIMER ELECTRIC 1-HR 24V ECCOPAP-C, ECCOPAP-JFA, ECCOPAP-K,
10 2C-20102-08 6 SCRW PHD ST 8-32X.375 ECCOPAP-C 2C-20102-08 10 SCRW PHD ST 8-32X.375 ECCOPAP-JFA, ECCOPAP-K, ECCOPAP-KFA,
11 2E-31400-07 1 XFORMR120-208-240/24V40VA ECCOPAP-C, ECCOPAP-JFA, ECCOPAP-KFA 2E-31400-15 1 XFRMR 480/24VAC ECCOPAP-U 2E-31400-18 1 XFORM 380/24VAC 40VA U/L ECCOPAP-K
12 Q9-ECCO-285-2 1 SPOT COMPONENT MOUNT SII ECCOPAP-C, ECCOPAP-JFA, ECCOPAP-K,
13 2C-20102-05 2 SCRW HXHD ST 8-32X.75 ECCOPAP-C, ECCOPAP-JFA, ECCOPAP-K,
14 2E-30501-02 1 TRM STRP 3 POLE W/PUSH ON ECCOPAP-C, ECCOPAP-JFA, ECCOPAP-K,
15 2C-20102-12 2 SCRW PHD ST 10-32X3/8 ECCOPAP-C, ECCOPAP-JFA, ECCOPAP-K,
16 2E-30701-05 1 CONTC 2POLE 30A 24VAC P & ECCOPAP-C, ECCOPAP-JFA, ECCOPAP-K,
17 2K-70801-07 3 SPACER SUPPORT 1/2LG ECCOPAP-C, ECCOPAP-JFA, ECCOPAP-K,
18 2E-40101-19 1 CIRBD SI TEMP CNTRL NO ECCOPAP-C, ECCOPAP-JFA, ECCOPAP-K,
19 2E-30700-06 1 CONTC3POLE35A24VAC50/60HZ ECCOPAP-C, ECCOPAP-JFA, ECCOPAP-K,
20 2E-31800-01 4 CB 250V50A 1 POLE CRLNGSW ECCOPAP-C 2E-31800-04 1 CB 480V 50A 3 POLE ECCOPAP-JFA, ECCOPAP-K, ECCOPAP-KFA,
1
IMPORTANT: WHEN ORDERING, SPECIFY VOLTAGE OR TYPE GAS DESIRED PAGE
2
INCLUDE MODEL AND SERIAL NUMBER OF
Some items are included for illustrative purposes only and in certain instances may not be available.
Part
Number
Qty Per
2 KNB BLK 1/4BUSH2SETSCW@90 ECCOPAP-C, ECCOPAP-K, ECCOPAP-U
1
Description
AP440VM/480VM
ECCOPAP-U
ECCOPAP-U
LABEL SWITCH FOR R/S INF ECCOPAP-JFA, ECCOPAP-KFA
ECCOPAP-KFA, ECCOPAP-U
ECCOPAP-KFA, ECCOPAP-U
ECCOPAP-KFA, ECCOPAP-U
ECCOPAP-U
ECCOPAP-KFA, ECCOPAP-U
ECCOPAP-KFA, ECCOPAP-U
ECCOPAP-KFA, ECCOPAP-U
ECCOPAP-KFA, ECCOPAP-U
ECCOPAP-KFA, ECCOPAP-U
ECCOPAP-KFA, ECCOPAP-U
ECCOPAP-KFA, ECCOPAP-U
ECCOPAP-KFA, ECCOPAP-U
ECCOPAP-U
Star Manufacturing International, Inc.
Page 25
PARTS LIST June 30, 2008, Rev. C
Model No: ECOF-AP, & ECOD-AP CONTROLS PANEL
Commercial & Marine Full Size Electric Convection Oven
Key
Number
21 2C-20102-04 3 SCRW PHD ST 8-32X.5 PLTD ECCOPAP-JFA, ECCOPAP-K, ECCOPAP-KFA, 2C-20102-04 4 SCRW PHD ST 8-32X.5 PLTD ECCOPAP-C
22 Q9-ECCO-289 1 FUSE MOUNT - SII 208-240V ECCOPAP-C Q9-ECCO-289-1 1 FUSE MOUNT - SII 480V ECCOPAP-JFA, ECCOPAP-K, ECCOPAP-KFA,
23
2C-20101-26
24 2J-30802-04 1 BUZZER ELEC 24V AC PIEZIO ECCOPAP-C, ECCOPAP-JFA, ECCOPAP-K,
25 2C-20103-06 2 SCRW SM PLT 6 X 3/8 PHL ECCOPAP-C, ECCOPAP-JFA, ECCOPAP-K,
26 2E-30901-08 2 FUSE HLDR FOR SC FUSE ECCOPAP-C, ECCOPAP-JFA, ECCOPAP-K,
27 2C-20101-52 4 SCRW RHD MS 8-32 X 1/2 ECCOPAP-C, ECCOPAP-JFA, ECCOPAP-K,
28 2E-30900-10 2 FUSE 15AMP 300V (SC-15) ECCOPAP-C, ECCOPAP-JFA, ECCOPAP-K, NI 2E-30600-10 1 RELAY 2PDT 240V ECCOPAP-JFA, ECCOPAP-KFA
NI 2E-30705-03 1 CONTC 2-SPD MTR ABB ECCOPAP-K, ECCOPAP-KFA, ECCOPAP-U
Part
Number
2C-20101-26
Qty Per
4 SCRW MS PLT 6-32 X .25 ECCOPAP-JFA, ECCOPAP-K, ECCOPAP-KFA, 6
Description
ECCOPAP-U
ECCOPAP-U
ECCOPAP-U
SCRW MS PLT 6-32 X .25 ECCOPAP-C
ECCOPAP-KFA, ECCOPAP-U
ECCOPAP-KFA, ECCOPAP-U
ECCOPAP-KFA, ECCOPAP-U
ECCOPAP-KFA, ECCOPAP-U
ECCOPAP-KFA, ECCOPAP-U
2
IMPORTANT: WHEN ORDERING, SPECIFY VOLTAGE OR TYPE GAS DESIRED PAGE
2
INCLUDE MODEL AND SERIAL NUMBER OF
Some items are included for illustrative purposes only and in certain instances may not be available.
Star Manufacturing International, Inc.
Page 26
SK2367 Rev. A 6/03/08
ECOF: CAN & MOTOR ASSEMLBY
Detail B
168 28 33 34
Suggested Marine Parts Stocking
1
2
3
4
5
6
7
8
9
10
14
17
4
18 19 20
21
13
15
22 13
23
25
26
27
35
28
30
31
27
32
33
34
29
24
15
16
11
12
13
Page 27
PARTS LIST June 30, 2008, Rev. C
Model No: ECOF & ECOD CAN & MOTOR ASSEMBLY
Commercial & Marine Full Size Electric Convection Oven
Key
Number
1 2U-71500-05 1 BLOWER WHEEL ECCO/GCCO ECOF, ECOD 2 2C-20101-42 4 SCRW THD MS 10-24X2 PLTD ECOF, ECOD 3 2C-20301-09 2 NUT HEX 10-24 PLTD ECOF, ECOD 4 Q9-ECCO-168 1 MOTOR MOUNT WELD ECOF, ECOD 5 2C-20111-02 8 SCRW HXHD CAP 1/4-20X3/4 ECOF, ECOD 6 2H-ECCO-172 1 MOTOR INSULATION ECOF, ECOD 7 Q9-GCCO-166-2 1 SPACER - SAFETY STAT ECOF, ECOD 8 2T-30401-09 1 STAT FXD 500 DEG OPEN ECOF, ECOD 9 2C-20301-10 2 NUT HEX 6-32 PLTD ECOF, ECOD 10 Q9-GCCO-167 1 MOTOR SHIELD ECOF, ECOD 11 2C-20301-09 2 NUT HEX 10-24 PLTD ECOF, ECOD 12 2C-31900-03 1 CABLE STRAPS 3/16X7 ECOF, ECOD 13 2C-20103-02 4 SCRW SM PLT 10 X .5 PHLSL ECOF, ECOD 14 2K-70801-01 1 SNAP BUSH 7/16 SB437-5 ECOF, ECOD 15 2K-70801-04 1 SNAP BUSH 3/4 SB750-10 ECOF, ECOD 16 2U-30200-16 1 MTR 1/3HP 460V/1/60HZ 2SP ECOF-AP-480V, ECOF-AP440VM, ECOF-AP480VM, 2U-30200-17 1 MTR 1/3HP208/240V1PH2SPD ECOF-AP, ECOD-AP 2U-30200-53 1 MTR 1/3HP240/254V50HZ2SP ECOF-AP2/4FA 2U-30200-60 1 MTR 1/3HP380V1PH50HZ2SP ECOF-AP-380V, ECOF-AP380FA 17 2C-20118-01 4 SCRW CARRAGE PLT 5/16X.75 ECOF, ECOD 18 2C-20201-09 4 WSHR PLT 5/16 FLAT SAE ECOF, ECOD 19 2C-20202-08 4 WSHR PLT 5/16 LOCK SPLIT ECOF, ECOD 20 2C-20301-06 4 NUT HEX 5/16-18 PLTD ECOF, ECOD 21 Q9-ECCO-122 1 ELEMENT TOP COVER ECOF, ECOD 22 Q9-GCCO-115-1 1 MOTOR WIRE HOLDER ECOF, ECOD 23 Q9-ECCO-123 1 ELEMENT SIDE COVER ECOF, ECOD 24 2C-20102-04 40 SCRW PHD ST 8-32X.5 PLTD ECOF, ECOD 25 Q9-GCCO-247 1 PROBE HOLDER [ECCO & ECOF, ECOD 26 Q9-50312-34 1 PROBE COVER ECCO/GCCO ECOF, ECOD 27 2C-20109-04 4 SCRW THD MS SS 10-32X3/8 ECOF, ECOD 28 2N-11090-16 1 ELE ECCO OVN 208/240V11KW ECOF-AP, ECOF-AP2/4FA, ECOD-AP 2N-11090-18 1 ELMNT ECCO 480V 11KW ECOF-AP-480V, ECOF-AP480VM, ECOD-AP-480V 2N-1 ECOF-AP440VM 29 30 2C-20112-02 4 SCRWSHLDRTHUM 1/4-20X3/8 ECOF, ECOD 31 Q9-ECCO-163 1 REAR BAFFLE SPOTWELD ECOF, ECOD 32 Q9-GCCO-431 2 LIGHT RING - CORRECTIONAL ECOF, ECOD 33 2S-31603-04 2 LAMPS INC 250V 50W ECOF, ECOD 34 2E-31602-04 2 LAMP SKT SNAP-IN WHT ECOF, ECOD 35 2E-41100-08 1 SENSOR OVEN TEMP CONTROL ECOF, ECOD
Part
Number
1090-30 1 ELE 415 440V11KW ECOF-AP-380V, ECOF-AP380FA,
2C-20103-02 8 SCRW SM PLT 10 X .5 PHLSL ECOF, ECOD
Qty Per
Description
ECOD-AP-480V
1
IMPORTANT: WHEN ORDERING, SPECIFY VOLTAGE OR TYPE GAS DESIRED PAGE
1
INCLUDE MODEL AND SERIAL NUMBER OF
Some items are included for illustrative purposes only and in certain instances may not be available.
Star Manufacturing International, Inc.
Page 28
STAR MANUFACTURING
10 Sunnen Drive, St. Louis, MO 63143 U.S.A.
(800) 807-9054 (314) 781-2777
Parts & Service (800) 807-9054
www.star-mfg.com
Loading...