Lang CSE12-208VCD, CSE12A-1, CSE12A-6G, CSE12A-1G, CCSE12A-208 User Manual

...
Page 1
ELECTRIC CLAMSHELL
®
CSE12-208VCD, CSE12A-1, CSE12A-2
Glass Surface
CSE12A-1G thru CSE12A-6G
Contact Clam
CCSE12A-208
Installation and
Instructions
2M-W363 Rev. F 3/19/2015
CSE12A
Page 2
SAFETY SYMBOL
These symbols are intended to alert the user to the presence of important operating and maintenance instructions in the manual accompanying the appliance.
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN
INSTRUCTIONS TO BE FOLLOWED IN THE EVENT USER SMELLS GAS. THIS
INFORMATION SHALL BE OBTAINED BY CONSULTING YOUR LOCAL GAS SUPPLIER.
AS A MINIMUM, TURN OFF THE GAS AND CALL YOUR GAS COMPANY AND YOUR
AUTHORIZED SERVICE AGENT. EVACUATE ALL PERSONNEL FROM THE AREA.
IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE
CAN CAUSE PROPERTY DAMAGE, INJURY OR DEATH. READ THE INSTALLATION,
OPERATION & MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR
WARNING, TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO NOT REMOVE
CONTROL PANEL. NO USER-SERVICABLE PARTS INSIDE. REPAIRS SHOULD BE DONE BY AUTHORIZED SERVICE PERSONNEL ONLY.
FOR YOUR SAFTEY
THE VICINTIY OF THIS OR ANY OTHER APPLIANCE.
POST IN PROMINENT LOCATION
WARNING
SERVICING THIS EQUIPMENT.
WARNING
RISK OF FIRE OR ELECTRIC SHOCK
DO NOT OPEN
NOTICE
Using any part other than genuine Lang factory supplied parts relieves the manufacturer of all liability.
Lang reserves the right to change specications and product design without notice. Such
revisions do not entitle the buyer to corresponding changes, improvements, additions or replacements for previously purchased equipment.
Due to periodic changes in designs, methods, procedures, policies and regulations,
the specications contained in this sheet are subject to change without notice. While Lang exercises good faith efforts to provide information that is accurate, we are not
responsible for errors or omissions in information provided or conclusions reached as a
result of using the specications. By using the information provided, the user assumes all risks in connection with such use.
MAINTENANCE AND REPAIRS
Contact your local dealer for service or required maintenance. Please record the model number, serial
number, voltage and purchase & Installation Information in the area below and have it ready when you
call to ensure a faster service.
Model No.:
Serial No.:
Voltage:
Purchased From:
Location:
Purchase
Date:
2M-W363: Electric Clamshell® CSE12A
1-Phase
or 3 Phase:
Installed Date:
2
Page 3
PROBLEMS, QUESTIONS or CONCERNS
Before you proceed consult you authorized Lang service agent directory
or
Call the Lang Technical Service & Parts Department at 314-678-6315
TABLE OF CONTENTS
Saftey Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . 4
General Information
Lockout Procedures . . . . . . . . . . . . . . . . . . . . . . . . 4
Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Technical . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Receiving the unit . . . . . . . . . . . . . . . . . . . . . . . . . 5
Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Un-crating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Installation
Electrical Connection . . . . . . . . . . . . . . . . . . . . . . . 6
Clearance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Initial Start-Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Cleaning
Daily . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Weekly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Glass Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Crome Surfaces . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Hood Stop Adjustments . . . . . . . . . . . . . . . . . . . . . . . . 9
Operating Instructions CONTACT CLAM ONLY . . . . . . . . . . . . 10
Exploded View & Parts List
CSE12-208VCD, CSE12A-1, CSE12A-2 . . . . . . . . . . . . 12-13
2M-W363: Electric Clamshell® CSE12A
CSE12A-1G thru 6G (glass surface) . . . . . . . . . . . . . . 14-15
CSE12-CC208 (contact clam) . . . . . . . . . . . . . . . . . . 16-18
Wiring Diagram
CCSE12A1 (contact clam) . . . . . . . . . . . . . . . . . . . .19
CSE12A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
NOTICE Service on this or any other Lang appliance must be performed by
qualied personnel only. Consult your Lang Authorized Service Agent
Directory. You can call our service number 314-678-6315 or visit our website www.langworld.com for the service agent nearest you.
3
Page 4
Safety Precautions
Lang manufacturing, hereby disclaims any and all responsibility for injury, damage, loss or other claim that may occur
to person or property from improper alteration, modication, addition, operation, maintenance or service, whether it be mechanical, electrical, or otherwise, which may occur from such improper alteration, modication, addition, operation,
maintenance or service to this piece of equipment.
Safety Considerations
Your 12-inch Clamshell® is manufactured to rigid standards. This equipment is approved by a certifying agency to conform to safety and sanitation standards.
The presence of safety equipment control and interlocks on an appliance and attendant components of installation cannot in and of themselves, assure absolute safety of operation. Diligent, capable, well-trained operators and maintenance personnel, as well as proper programs of operation and maintenance, are essential to the safe and reliable operation of this appliance.
A. The responsibility of the manufacturer is to supply suitable, comprehensive instructions and recommendations
for the operation and maintenance of the appliance.
B. Trained qualied and factory-authorized personnel must perform all operation, maintenance and repair of these
appliances. It is the responsibility of the owner/operator to ensure that this happens.
C. A regular periodic program of cleaning, inspection and maintenance must be established and comprehensive
maintenance records maintained. It is the sole responsibility of the user to establish, schedule and enforce the frequency and scope of these programs in keeping with recommended practice and with due consideration given to actual operating conditions.
D. Operate this appliance within the limits it was designed for, which will not exceed the working limits of any component
within the appliance as a whole.
HIGH VOLTAGES ARE PRESENT INSIDE THIS APPLIANCE WHEN THE UNIT IS PLUGGED/ WIRED INTO A LIVE RECEPTACLE. BEFORE REPLACING ANY PARTS, DISCONNECT THE
WARNING
CAUTION
UNIT FROM THE ELECTRIC POWER SUPPLY.
USE OF ANY REPLACEMENT PARTS OTHER THAN THOSE SUPPLIED BY LANG MANUFACTURING, OR THEIR AUTHORIZED DISTRIBUTORS CAN CAUSE BODILY INJURY OT THE OPERATOR AND DAMAGE TO THE EQUIPMENT EIWLL VOID ALL WARRANTIES.
GENERAL INFORMATION
Lockout Procedure
Announce lockout to other personnel.
Turn power off at main panel.
Test lockout by turning power switch on and observing if elements come on.
Check heater circuit with voltmeter.
Perform necessary repairs or tests.
Clear the unit of personnel before starting the griddle.
Turn power on at main panel.
Announce unit is “on” to other personnel.
Controls
The broiler turns on with the power switch of the griddle.
The broiler operates with full power when it is in the closed position. In the open position, the broiler will operate with partial power and be in the “idle” mode.
2M-W363: Electric Clamshell® CSE12A
Controls Contact Clam
This broiler turns on using the separete control box, see Operating instructions on page 10.
4
Page 5
GENERAL INFORMATION continued
Technical
The broiler, not including the griddle, is standard 208 or 240V, single phase. Specify voltage when ordering.
Receiving the Unit
Upon receipt, check for freight damage, both visible and concealed. Note visible damage on the freight bill at the time of delivery and have the carrier’s agent sign the freight bill at that time. Concealed loss or damage means loss or damage, which does not become apparent until the merchandise has been unpacked. Make a written request for inspection
upon unpacking and nding concealed damage within 15 days of delivery. Keep all packing
material for inspection. Do not return damaged merchandise to Lang Manufacturing. File your claim with the carrier.
Location
Prior to un-crating, move the unit as near its intended location as practical. The crating will help protect the unit from the physical damage normally associated with moving it through hallways and doorways.
Un-crating
The unit will arrive completely assembled inside a wood frame covered by cardboard box and strapped to a skid. Remove the cardboard cover, cut the straps and remove the wood frame.
CAUTION
NOTICE
SHIPPING STRAPS ARE UNDER TENSION AND CAN SNAP BACK WHEN CUT.
Remove unit from the skid.
2M-W363: Electric Clamshell® CSE12A
THE UNIT IS EXTREMELY HEAVY. FOR SAFE HANDLING, INSTALLER SHOULD OBTAIN
HELP AS NEEDED OR EMPLOY APPROPRIATE MATERIALS-HANDLING EQUIPMENT (SUCH AS A FORKLIFT, DOLLY OR PALLET JACK) TO REMOVE THE UNIT FROM THE SKID AND MOVE IT TO THE PLACE OF INSTALLATION.
ANY STAND, COUNTER OR OTHER DEVICE ON WHICH THE UNIT WILL BE LOCATED MUST BE DESIGNED TO SUPPORT THE WEIGHT OF THE UNIT.
5
Page 6
INSTALLATION
Electrical Connection
Verify griddle installation was performed as directed in the installation instructions.
Connect electrical service to the box at the back of the griddle.
Electrical specications are located on the data plate.
Clearance
Use this griddle only in non-combustible locations.
Maintain clearances of base appliance.
THIS APPLIANCE MUST BE GROUNDED AT THE TERMINAL PROVIDED. FAILURE TO
WARNING
WARNING
GROUND THE APPLIANCE COULD RESULT IN ELECTROCUTION AND DEATH.
INSTALLATION OF THE UNIT MUST BE DONE BY PERSONNEL QUALIFIED TO WORK WITH ELECTRICITY AND PLUMBING. IMPROPER INSTALLATION CAN CAUSE INJURY TO PERSONNEL AND/OR DAMAGE TO EQUIPMENT. UNIT MUST BE INSTALLED IN ACCORDANCE WIHT ALL APPLICABLE CODES.
WARNING
NOTICE
NOTICE
BROILER ELEMENTS CAN IGNITE GREASE FIRES ON THE GRIDDLE SURFACE, WHICH MAY RESULT IN PROPERTY DAMAGE, SERIOUS INJURY OR DEATH. ENSURE GRIDDLE SURFACE IS SLOPPED DOWN FROM BACK TO FRONT BY AT LEAST 1/4” BEFORE COOKING.
The data plate is located behind the Clamshell® between the two pivot arms. The
Clamshell® voltages, wattage, serial number, wire size and clearance specications are on
the data plate. Carefully read and understand this information before proceeding with the installation.
The installation of any components such as a vent hood, grease extractors or re
extinguisher systems must be conform to the applicable National, State and locally
recognized installation standards.
2M-W363: Electric Clamshell® CSE12A
6
Page 7
INITIAL START UP
Each unit is preheated, tested and calibrated at the factory prior to shipment. However, due to temperature and climate changes during shipment the unit can absorb moisture. Check griddle for moisture and allow the unit to dry before placing the unit into full operation.
Prior to putting any unit into full time operation at normal cooking temperatures, it must be thoroughly “seasoned” or dried out. Moisture absorption in the closed spaces, in the insulation and even inside the heating elements can cause future trouble if not properly treated.
Allow the element in the unit to dry thoroughly prior to the initial use. To dry the unit, cycle the unit on and place the hood into the down position. Allow the unit to saturate until all vapor and condensation have been removed. For best operating results allow the unit to thoroughly dry out for 8 to 12 hours.
Pre-heat the griddle for one hour, if the unit has been out of service for three days, especially when exposed to high humidity and/or cool temperatures.
During the rst few hours of operation, you may notice a small amount of smoke and a
NOTICE
faint odor from the smoke. This is normal for a new unit and will disappear after the rst
few hours of use.
ALWAYS KEEP THE AREA NEAR THE APPLIANCE FREE FROM COMBUSTIBLE MATERIALS.
CAUTION
Once the griddle has been loaded properly, lower the hood over the product.
Elements must not touch product when clamshell is in the closed position.
2M-W363: Electric Clamshell® CSE12A
KEEP FLOOR IN FRONT OF EQUIPMENT CLEAN AND DRY. IF SPILLS OCCUR, CLEAN IMMEDIATELY TO AVOID THE DANGER OF SLIPS OR FALLS.
7
Page 8
CLEANING
Daily Cleaning
Clean the exterior of the appliance with cleaner and water.
Wipe drip shield between hood and griddle to remove any grease.
Weekly Cleaning
Allow the hood to burn off any carbon build up after high use periods.
With a cold griddle, lower the hood and allow the hood to cook for 30 minutes. Additional time may be necessary for more baked-on grease.
Glass Cleaning
Never use abrasives or a dull scraper on the glass surface. Scratches and nick in the glass will form weak spots and can cause the glass to break if an impact occurs.
CAUTION
Daily: mist the surface with warm water and wipe with a soft towel; doing this daily will reduce the build-up that could occur over a period of time. This can be done while the surface is warm, but the unit MUST BE TURNED OFF.
For a more extensive cleaning, use a product such as WEIMAN® Glass Cooktop Cleaner, directions for cleaner must be followed.
CHROME SURFACES (certain models)
It takes very little time and effort to keep this Industrial Chrome griddle surface sparkling clean and performing at top
efciency. DO NOT allow grease to accumulate as it will carbonize and become difcult to remove.
To prevent this condition, the following cleaning suggestions should be followed:
1. Remove excess oil and food regularly with a 4” (100mm) wide razor sharp type scraper and wipe surface with a
damp cloth if desired.
2. Following the scraping, for end of the day cleaning, a damp cloth and a non-silicate, non-abrasive, non-chlorinated cleaner such as Bon-Ami may be used to wipe surface clean, followed by wiping with clean wet cloth.
3. Follow daily cleaning steps for Non-Chrome Surfaces.
ON CROME SURFACES:
1. Never use pumice, griddle stones, or abrasives on the surface.
2. Never strike the surface with a sharp instrument or spatula edge.
3. Never use steel wool.
4. Never use commercial liquid grill cleaner on the griddle surface.
Abusing the surface voids the warranty.
2M-W363: Electric Clamshell® CSE12A
8
Page 9
HOOD STOP ADJUSTMENT
Units with an Adjustable Hood Stop Installed have the capablity to adjust between a 40° to 45° degree
settings. These simple steps will assist you in accomplishing this. If you have dif culty accomplishing this,
please call a quali ed service agent or Star Manufacturing Technical Service Department.
1. Remove the front bolts from the hood stop, and loosen the back bolts up, do not completely remove the back
bolts.
2. Adjust the hood stop to the desired position, the top hole is to stop the hood at 40° degrees the bottom hole is to
stop the hood at 45° degrees.
3. Re-install the front bolts and tighten up the back bolts.
Hood Stop
Front Bolt
2M-W363: Electric Clamshell® CSE12A
Rear Bolt
9
Page 10
OPERATING INSTRUCTIONS CONTACT CLAM ONLY
1. Turn unit on by placing switch in "ON" position. The "Heat On" indicator, program number and display will ash
indicating unit is heating. When the preset temperature is reached, the heating light, display and program light
indicator will stop ashing followed by 3 beeps. (Initial startup heating time is approximately 30 minutes).
2. Place product on the bottom cooking surface of the unit and close the lids.
3. Press program button and let displayed time count down to "0" at which time unit will beep. To turn off the beeper, press program button again.
4. Raise lids until it engages into rst indent and remove food. Using spatula, scrape residue into grease catcher
tray.
5. Turn the unit off when not in use.
TEMPERATURE/TIMER CONTROLLER OPERATION SPECIFICATIONS Startup:
1. The preset time will ash until preset temperature is reached.
2. When the control reaches preset temperature, time display, "Heat On" indicator and program indicator will stop
ashing and the alarm will beep three times.
Temperature:
1. To view the actual temperature, press and hold "Temp Button." Display will read "Lo F" if temperature is below 273°F (134°C) and "Hi F" if temperature is above 573°F (301°C).
To Program Time and Temperature:
1. Press and hold "TEMP" (actual temperature displays).
2. While holding "TEMP," press and hold any program button on the Left one second, the LED above the program number light and the display reads "_ _ _ _." Enter the four-digit security code sequence, 4, 3, 2, 1. The security code will not show on the display. Once the correct sequence has been entered, the preset time will be displayed
and the LED for that program will begin to ash.
3. Set the time with the "+ or -" buttons.
4. Press the "TEMP" button to save the time.
5. The preset temperature will now be displayed.
6. Set the desired temperature for this program using the "+ or -" buttons.
7. Press the "TEMP" button to save temperature and to exit programming mode for this program. The LED will
stop ashing but will remain lit.
8. Press any other program button within 15 seconds to continue programming without re-entering the security code.
9. While programming a program (LED is ashing), if no input is received for 15 seconds, the unit will revert to
normal operation and the security code must be re-entered.
Note: Each programming change must be saved by pressing the "TEMP" button!
10
2M-W363: Electric Clamshell® CSE12A
Page 11
2M-W363: Electric Clamshell® CSE12A
11
Page 12
Parts List
Parts List
ETL File 68964 Rev.A2007
12
11
2M-W363: Electric Clamshell® CSE12A
Page 13
PARTS LIST March 19, 2015, Rev. F
Model: CSE12-208VCD, CSE12A-1-208V, CSE12A-2-208V Clamshell Hood
Fig No. Part Description Qty Application
1 2N-11160-32-2 STLHTR208VXLH1600W42.5WSI 2
1A 2N-11160-32-4 STLHTR240VXLH1600W42.5WSI 2 CSE12A-1-240, A-2-240, A-3-240, A-4-240, A-5-240, A-6-240
2 2E-30500-02 TRM STRP 4 POLE 30A 600V 1 ALL
3 2E-30501-03 TERM STRP 4 POLE W/PUSH 1 ALL
4 2E-30705-01 CONTC 2-SPD MTR 25A 24VAC 1 ALL
5 2J-40302-02 CANCTR/RECEPTACLE GGB 1 ALL
6 2P-51002-15 HOOD SPRING XLH12 NEW 1 ALL
7 K9-60102-13582 BRIDGE TO HOOD WIRE 1 ALL
8 K9-60102-13588 ROD ASY HOOD SPRNG XLH12 1 ALL
9 K9-60102-XLH609 FRONT HOOD WRAP 1 ALL
10 2K-70801-04 SNAP BUSH 3/4 SB750-10 1 ALL
11 K9-EZG-418-1 OUTER BOX SPOTWELD CSE12 1 ALL
12 K9-EZG-429 SPOT CONNECTOR MOUNT 1 ALL
13 K9-EZG-430 BOX HEAT SHIELD COMBO 1 ALL
14 K9-EZG-433 BOX HEAT SHIELD #2 COMBO 1 ALL
15 K9-EZG-436-1 BOX HEAT SHIELD SPACER 1 ALL
16 K9-XLH-709-1 HANDLE ASSY. CSE12 1 ALL
17 K9-XLH-740-1 Hood switch svc kit 1 ALL
17 2E-30307-04 SWT MERCURY TILT HI-TEMP 2 ALL
18 K9-XLH-636-21 BRIDGE COVER 2’ CSE12 NO 1 ALL
19 K9-XLH-659 RIGHT STANCHION COVER 1 ALL
19 K9-XLH-659-1 RIGHT STANCHION CVR 1 ALL
20 K9-XLH-660-1 LEFT STANCHION CVR 1 ALL
21 K9-XLH-735-221 CON. BOX/FLUE 2’GAS-12 NO 1 ALL
NI K9-XLH-704-01 ELEMENT ASSY 208 1
NI K9-XLH-704-02 ELEMENT ASSY 240 1 CSE12A-1-240, A-2-240, A-3-240, A-4-240, A-5-240, A-6-240
NI K9-XLH-781 HOOD STOP BRACKET 1 CSE12-208VCD
NI 2A-XLH-782 HOOD STOP 2 CSE12-208VCD
CSE12-208VCD, A-1-208, A-2-208, A-3-208, A-4-208, A-5-208, A-6-208
CSE12-208VCD, A-1-208, A-2-208, A-3-208, A-4-208, A-5­208, A-6-208
NI 2E-30900-30 FUSE, 60 AMP 2 ALL
2M-W363: Electric Clamshell® CSE12A
13
Page 14
25
1
2
3
27
26
1
24
18
23
22
21
19
20
4
5
6
1
Purchase these
items together
7
8
2M-W363: Electric Clamshell® CSE12A
9
17
16
13
14
15
1
12
11
10
Model: CSE12A-1G thru CSE12A-6G
CLAMSHELL HOOD GLASS
14
SK2522, Rev. -, 6/15/2011
Page 15
PARTS LIST March 19, 2015, Rev. F
Model: CSE12A-1G thru 6G, Clamshell Hood Glass
Fig No. Part Number Description Qty Application
1 2C-20111-09 SCRW HXHD CAP 10-32X1/2 24
2 K9-XLH-706-W1 REAR COVER ASSEMBLY-XLH12 1
3 K9-XLH-734 BRIDGE TO HOOD WIRE 1
4 K9-XLH-788 BASE - ELEMENT BRACKET 2
5 K9-XLH-789 BRACKET - ELEMENT 4
2N-11160-32-2 STLHTR208VXLH1600W42.5WSI
6
2N-11160-32-4 STLHTR240VXLH1600W42.5WSI 240V
7 2Q-71300-20 GLASS - HIGH TEMP CERAMIC 1
8 1P-72602-38 TAPE-FIBERGLASS 1”x1/16TK 5.21 FT
9 K9-XLH-268 FRAME - GLASS CLAMSHELL 1
10 2C-Z6925 SCREW #8X1/2 HEXW B SS 6
11 K9-XLH-705-01 ELEMENT HOLDER ASSY 1
12 K9-XLH-628-01 ELEMENT CLAMP 1
13 2C-20301-11 NUT HEX 8-32 PLTD 2
14 2C-20202-12 WSHR LOCK #8 INT STAR 2
15 K9-XLH-742-1 MERCURY SWITCH BRACKET 1
16 K9-XLH-741-1 MERCURY SWITCH BASE 1
17 2C-20101-28 SCRW THD MS 8-32X3/8 PLTD 2
18 2I-70803-04 CERMC INSLTR 9/32ID11/16 1
19 2E-30307-04 SWITCH MERCURY TILT 2
20 K9-60102-13588 ROD ASSY HOOD SPRNG 1
21 2P-51002-15 HOOD SPRING XLH12 NEW 1
22 K9-XLH-611 HANDLE BRACE TOP 1
23 K9-XLH-612 HANDLE BRACE BOTTOM 1
24 2C-20104-61 SCRW 1/4-28X3/4 FLT HD SO 2
25 K9-XLH-709-1 HANDLE ASSY. CSE12 1
26 K9-XLH-707 FOREWARD HOODWRAP ASSY 1
27 2M-60301-W2 LANG CLAMSHELL LOGO 1
2M-W363: Electric Clamshell® CSE12A
2
208V
1
IMPORTANT: WHEN ORDERING, SPECIFY VOLTAGE OR TYPE GAS DESIRED PAGE
1
INCLUDE MODEL AND SERIAL NUMBER OF
Some items are included for illustrative purposes only and in certain instances may not be available.
15
Page 16
1
See Detail A
3
2
5 6 7
4
17
8
13
14
15
16
12
9
10
11
SK2742, Rev. - , 02/10/14
2M-W363: Electric Clamshell® CSE12A
Model: CCSE12A1
Contact Clam
16
Page 17
PARTS LIST March 19, 2015, Rev. F
Model: CCSE12A1 Contact Clam
Fig No. Part Number Qty Description
1 K9-XLH-709-1 1 HANDLE ASSY. CSE12
2 K9-XLH-821 1 TOP COVER
3 K9-XLH-822 1 COVER CLOSE OFF PLATE
4 2M-60301-W2 1 LANG CLAMSHELL LOGO
5 K9-XLH-761-1 1 LEFT HINGE ARM PIVOT ASSY
6 K9-XLH-762-1 1 RIGHT HINGE ARM PIVOT ASY
7 K9-XLH-721-4 1 PIVOT ASSY CCSE12
8 K9-XLH-644 2 PISTON ROD TUBE SLEEVE
9 K9-XLH-813 1 SPRING BAFFLE
10 2N-11060-30 1 ELEMENT 208V 3600W
11 K9-XLH-820 1 CC WELDED ASSY
12 2E-Z3278-1 1 RTD PROBE - 48” LONG WIRE
13 2C-20111-09 4 SCRW HXHD CAP 10-32X1/2
14 K9-XLH-763-1 2 SPRING TUBE END-CCSE12
15 K9-XLH-703-4 2 SPRING ROD ASY XLH12-NEW
16 2P-51002-15 2 HOOD SPRING XLH12 NEW
17 2T-30401-34 1 STAT FIXED TEMP 375F
2M-W363: Electric Clamshell® CSE12A
17
Page 18
14
15
16
4
2
1
3
8
7
1
5
6
9
7
10
11
12
13
Detail
A
SK2743, Rev. - , 02/10/14
K9-XLH-580 Control Box Assembly
Model: CCSE12A1 Control Box
Fig No. Part Number Qty Description
1 2C-20103-02 8 SCRW SM PLT 10 X .5 PHLSL
2 K9-XLH-580-1 1 CONTROL BOX TOP-CCSE12A
3 2E-70505-17 1 CONDUIT CNNCTR 1/2 90o
4 1M-70502-03 60 inches CONDUIT TUBNG 1/2FLEX, (sold by the inch)
5 K9-XLH-580-4 1 CONTROL BOX BACK ASSY
6 2E-Z3335 1 RELAY DBL POLE-SNGL THROW
7 2C-20301-10 4 NUT HEX 6-32 PLTD
8 2E-05-07-0350 1 TRANSFORMER 230V/10V 6VA
9 2E-70505-02 1 CONDUIT CNNCTR 1/2 FLEX
10 K9-XLH-580-2 1 CONTROL BOX C-WRAP
11 2C-20301-11 4 NUT HEX 8-32 PLTD
12 2J-Z17605 1 CONTROL BOARD-CONTACT
13 2A-20504-12 4 SPACER - NYLON .312ODX.25
14 2M-60301-186 1 OVERLAY, CONTROL BOX ASSY
15 K9-XLH-580-3 1 CONTROL BOX FRONT ASSY
16 2E-Z12020 1 SWITCH-TOGGLE 2P ST
NI 2M-61113-W38 AR WIRING DIAGRAM, CCSE12A
2M-W363: Electric Clamshell® CSE12A
18
Page 19
61113-W38
PART NO.
LTR DATE DESCRIPTION OF CHANGE DR
-
CONTROL
E6
E5
E1
E4
E3
E2
-
-
- -
6 TAN
CONTACT CLAM W.D.
CCSE12A
MODEL NO.
MATERIAL
TITLE
-
-
FINISH
5 TAN
REVISIONS
RTD SENSOR
3 BLK
TO HEATING ELEMENTS
NO REPRODUCTION OR DISCLOSURE OF ITS CONTENTS IS PERMITTED.
THIS DRAWING CONTAINS INFORMATION CONFIDENTIAL TO STAR MFG. INT'L. INC.
RELAY/CONTACTOR
1 BLK
4 BLK
2 BLK
12 WHT
13 WHT
10 VAC.
10 WHT
11 WHT
10 VAC.
TRANSFORMER
208/240 VAC.
9 WHT8 WHT
ON/OFF SWITCH
7 WHT
2M-W363: Electric Clamshell® CSE12A
#10 SUNNEN DRIVE
ST. LOUIS, MO. 63143, USA
DATE
CK.
TOLERANCES UNLESS OTHERWISE NOTED
TDV 10-25-13
FRACTIONS ± 1/64 DECIMALS ± .005 ANGLES ± 1°
DR.
FUSE BLOCK
208/240V.
SUPPLY WIRE
19
Page 20
20
2M-W363: Electric Clamshell® CSE12A
Loading...