Lang CL130FFF Installation, Operation And Maintenance Instructions

Page 1
Installation, Operation, and Maintenance
Electric Cruise Line Fryer
Model CL130FFF
Lang Manufacturing 10 Sunnen Drive St. Louis, MO.63143-3800 Part Number: 2M-W482 Ph: 314-678-6315 : Fax: 314-781-2714 Rev.B WWW.LANGWORLD.COM September 27, 2013
Page 2
THE INFORMATION IN THIS MANUAL IS CRUCIAL AND MUST BE RETAINED FOR FUTURE REFERENCE. READ, UNDERSTAND AND FOLLOW THE INSTRUCTIONS AND WARNINGS CONTAINED IN THIS MANUAL.
DANGER
WARNING
CAUTION
NOTICE
POTENTIALLY HAZARDOUS SITUATION, WHICH, IF NOT AVOIDED, COULD RESULT IN DEATH.
POTENTIALLY HAZARDOUS SITUATION, WHICH, IF NOT AVOIDED, COULD RESULT IN DEATH OR SERIOUS INJURY.
POTENTIALLY HAZARDOUS SITUATION WHICH, IF NOT AVOIDED, MAY RESULT IN MINOR OR MODERATE INJURY.
Helpful operation and installation instructions and tips are present.
FOR YOUR SAFETY
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS NEAR THIS OR ANY OTHER APPLIANCE.
WARNING: IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE, INJURY OR DEATH. READ THE INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT.
Model #: Purchased from: Serial #: Location: Date purchased: Date installed: Purchase order #: For service, call:
WARNING
Lang Manufacturing 10 Sunnen Drive St. Louis, MO.63143-3800 Part Number: 2M-W482 Ph: 314-678-6315 : Fax: 314-781-2714 Rev.B WWW.LANGWORLD.COM September 27, 2013
THIS EQUIPMENT IS APPROVED FOR INSTALLATION ONLY ON VESSELS GREATER THAN 65 FEET IN LENGTH, IN ACCORDANCE WITH USCG REGULATIONS IN TITLE 46 CFR 110-113
Page 3
Table of Contents
Chapter Page
1. TABLE OF CONTENTS ....................................................................... 3
2. READ FIRST ........................................................................................ 4
3. UNPACKING ........................................................................................ 6
4. INSTALLATION .................................................................................... 7
5. INITIAL START-UP............................................................................... 8
6. OPERATION ......................................................................................... 9
7. CLEANING & MAINTENANCE PROCEDURES ................................. 10
8. TROUBLESHOOTING ......................................................................... 12
9. PARTS LISTS ....................................................................................... 14
10. EXPLODED VIEW ................................................................................ 16
11. WIRING DIAGRAMS ............................................................................ 19
Page 4
CAUTION THE FRYER WEIGHS 145 LBS. (65.91 KILOGRAMS).
FOR SAFE HANDLING, INSTALLER SHOULD OBTAIN HELP AS NEEDED, OR EMPLOY APPROPRIATE MATERIALS HANDLING EQUIPMENT (SUCH AS A FORKLIFT, DOLLY, OR PALLET JACK) TO REMOVE THE UNIT FROM THE SKID AND MOVE IT TO THE PLACE OF INSTALLATION.
CAUTION ANY STAND, COUNTER OR OTHER DEVICE ON
WHICH FRYER WILL BE LOCATED MUST BE DESIGNED TO SUPPORT THE WEIGHT OF THE FRYER (145 LBS.).
CAUTION SHIPPING STRAPS ARE UNDER TENSION AND CAN
SNAP BACK WHEN CUT.
DANGER THIS APPLIANCE MUST BE GROUNDED AT THE
TERMINAL PROVIDED. FAILURE TO GROUND THE APPLIANCE COULD RESULT IN ELECTROCUTION AND DEATH.
WARNING INSTALLATION OF THE UNIT MUST BE DONE BY
PERSONNEL QUALIFIED TO WORK WITH ELECTRICITY. IMPROPER INSTALLATION CAN CAUSE INJURY TO PERSONNEL AND/OR DAMAGE TO EQUIPMENT. UNIT MUST BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE CODES.
NOTICE The data plate is located behind the front control
panel. The fryer voltage, wattage, serial number, wire size, and clearance specifications are on the data plate. This information should be carefully read and understood before proceeding with the installation.
NOTICE The installation of any components such as a vent
hood, grease extractors, fire extinguisher systems, must conform to their applicable National, State and locally recognized installation standards.
CAUTION NEVER ENERGIZE THE HEATING ELEMENTS WITH
NO OIL IN THE KETTLE OR WITH THE OIL LEVEL MORE THAN 3 INCHES FROM THE LOWER FILL
CAUTION
LEVEL.
ALWAYS KEEP THE AREA NEAR THE APPLIANCE
FREE FROM COMBUSTIBLE MATERIALS.
CAUTION KEEP FLOOR IN FRONT OF EQUIPMENT CLEAN
AND DRY. IF SPILLS OCCUR, CLEAN IMMEDIATELY, TO AVOID THE DANGER OF SLIPS OR FALLS.
Page 5
WARNING ALWAYS TURN THE FRYER POWER SWITCH OFF
BEFORE LIFTING THE HEATING ELEMENTS OUT OF THE FRYER OIL.
WARNING BE SURE TO DRAIN THE OIL INTO A SUITABLE
CONTAINER.
WARNING KEEP WATER AND SOLUTIONS OUT OF CONTROLS.
NEVER SPRAY OR HOSE CONTROL CONSOLE, ELECTRICAL CONNECTIONS, ETC.
CAUTION MOST CLEANERS ARE HARMFUL TO THE SKIN, EYES,
MUCOUS MEMBRANES AND CLOTHING. PRECAUTIONS SHOULD BE TAKEN TO WEAR RUBBER GLOVES, GOGGLES OR FACE SHIELD AND PROTECTIVE CLOTHING. CAREFULLY READ THE WARNING AND FOLLOW THE DIRECTIONS ON THE LABEL OF THE CLEANER TO BE USED.
NOTICE Service on this or any other, STAR appliance must be
performed by qualified personnel only. Consult your authorized service agent directory or call the factory at (314) 678-6315 or visit our website the service agent nearest you.
www.langworld.com for
WARNING BOTH HIGH AND LOW VOLTAGES ARE PRESENT
INSIDE THIS APPLIANCE WHEN THE UNIT IS PLUGGED/WIRED INTO A LIVE RECEPTACLE. BEFORE REPLACING ANY PARTS, DISCONNECT THE UNIT FROM THE ELECTRIC POWER SUPPLY.
WARNING DO NOT THROW ICE INTO THE FRYER BASKET
WHILE THE UNIT IS HOT. FAILURE TO COMPLY MAY RESULT IN SERIOUS INJURY AND MAY DAMAGE THE EQUIPMENT.
CAUTION USE OF ANY REPLACEMENT PARTS OTHER THAN
THOSE SUPPLIED BY LANG OR THEIR AUTHORIZED DISTRIBUTORS CAN CAUSE BODILY INJURY TO THE OPERATOR AND DAMAGE TO THE EQUIPMENT AND WILL VOID ALL WARRANTIES.
5
Page 6
Unpacking
Receiving the Fryer
Upon receipt, check for freight damage, both visible and concealed. Visible damage should be noted on the freight bill at the time of delivery and signed by the carrier's agent. Concealed loss or damage means loss or damage, which does not become apparent until the merchandise has been unpacked. If concealed loss or damage is discovered upon unpacking, make a written request for inspection by the carrier's agent within 15 days of delivery. All packing material should be kept for inspection. Do not return damaged merchandise to Lang Manufacturing Company. File your claim with the carrier.
Location
Prior to un-crating, move the fryer as near its intended location as practical. The crating will help protect the unit from the physical damage normally associated with moving it through hallways and doorways.
Un-crating
The fryer will arrive completely assembled inside a wood frame covered by cardb oard box and strapped to a skid. Remove the cardboard cover, cut the straps and remove the wood frame.
CAUTION FRYER WEIGHS 145 LBS (65.91 kilograms). FOR SAFE HANDLING,
INSTALLER SHOULD OBTAIN HELP AS NEEDED, OR EMPLOY APPROPRIATE MATERIALS HANDLING EQUIPMENT (SUCH AS A FORKLIFT, DOLLY, OR PALLET JACK) TO REMOVE THE UNIT FROM THE SKID AND MOVE IT TO THE PLACE OF INSTALLATION.
CAUTION ANY STAND, COUNTER OR OTHER DEVICE ON WHICH FRYER WILL
BE LOCATED MUST BE DESIGNED TO SUPPORT THE WEIGHT OF THE FRYER (145 LBS.).
CAUTION SHIPPING STRAPS ARE UNDER TENSION AND CAN SNAP BACK
WHEN CUT.
Remove fryer from skid and place in intended location.
6
Page 7
Installation
DANGER THIS APPLIANCE MUST BE GROUNDED AT THE
TERMINAL PROVIDED. FAILURE TO GROUND THE APPLIANCE COULD RESULT IN ELECTROCUTION AND DEATH.
WARNING INSTALLATION OF THE UNIT MUST BE DONE BY
PERSONNEL QUALIFIED TO WORK WITH ELECTRICITY. IMPROPER INSTALLATION CAN CAUSE INJURY TO PERSONNEL AND/OR DAMAGE TO EQUIPMENT. UNIT MUST BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE CODES.
NOTICE The data plate is located behind the front control panel.
The fryer voltage, wattage, serial number, wire size, and clearance specifications are on the data plate. This information should be carefully read and understood before proceeding with the installation.
NOTICE The installation of any components such as a vent hood,
grease extractors, fire extinguisher systems, must conform to their applicable National, State and locally recognized installation standards.
Electrical Connection
Electrical service may be made through a standard 1¼-inch conduit. A hole should be cut out in one of two locations; the first is behind the unit on the right side (if looking from the back). It should be made 3” from the side and 3” from the bottom. The second location is on the bottom back right corner (if looking form the back). It should be made 2” from the side, and 3” from the back. Check the National Electrical Code for fuse for circuit breaker requireme nts.
Fryer Voltage
The Lang Model CL130-FFF can be operated on 440 Volts.
7
Page 8
Initial Start Up
PRE-POWER ON
Boil Out Fryer
WARNING
DO NOT THROW ICE INTO THE FRYER BASKET WHILE THE UNIT IS HOT. FAILURE TO COMPLY MAY RESULT IN SERIOUS INJURY AND MAY DAMAGE THE EQUIPMENT.
Ensure the elements are lowered into the fry pot. Fill the fry pot with a mixture of vinegar and water (1:10 mix). Fill until the vinegar and water level is maintained between the lower and upper fill marks. Heat to 200°F (93°C) and let stand for 30 minutes. After 30 minutes drain water and vinegar mix (see operation section for instructions). Be sure to wipe out and dry fry pot to remove any water spots.
Fill levels
There are two fill marks on the sides of the fryer kettle. The lower level indicates the fill mark with the elements out, the upper level indicates the fill mark when the elements are lowered. Fill and maintain the oil level between the upper and lower levels.
8
Page 9
Operation
CAUTION: NEVER ENERGIZE THE HEATING ELEMENTS WITH NO
OIL IN THE KETTLE OR WITH THE OIL LEVEL MORE THAN 3 INCHES FROM THE LOWER FILL LEVEL.
CAUTION: ALWAYS KEEP THE AREA NEAR THE APPLIANCE FREE FROM
COMBUSTIBLE MATERIALS.
CAUTION: KEEP FLOOR IN FRONT OF EQUIPMENT CLEAN AND DRY. IF
SPILLS OCCUR, CLEAN IMMEDIATELY, TO AVOID THE DANGER OF SLIPS OR FALLS.
Controls
The power switch, located on the control box at the front of the fryer, energizes the control circuits. When this switch is on, the “power” pilot lamp will be illuminated. Turn the temperature selector dial to the desired temperature setting. This control is located next to the power switch. The “heat” pilot lamp will illuminate indicating power is applied to the heating elements. The lamp marked “overtemp” will illuminate if the oil reaches an over-temperature condition. The over-temperature thermostat shuts off the fryer before the oil reaches a dangerously high temperature.
Heating Elements
The elements may be raised and locked in the up position. The latch is located on the rear top surface of the fryer and may be activated by lifting the handle at either side of the fryer.
Draining the Fryer Oil
WARNING: ALWAYS TURN THE FRYER POWER SWITCH OFF BEFORE
LIFTING THE HEATING ELEMENTS OUT OF THE FRYER OIL.
WARNING: BE SURE TO DRAIN THE OIL INTO A SUITABLE CONTAINER.
A drain valve is provided inside the lower cabinet door. To drain the cooking oil remove the steel cap from the drain pipe located at the bottom, lower, front left corner of the fryer. Connect a drain pipe extension to the drainpipe. Pull the lever located in the front bottom left corner of the fryer.
9
Page 10
Maintenance & Cleaning
Daily Cleaning
WARNING
KEEP WATER AND SOLUTIONS OUT OF CONTROLS. NEVER SPRAY OR HOSE CONTROL CONSOLE, ELECTRICAL CONNECTIONS, ETC.
DO NOT THROW ICE INTO THE FRYER BASKET
FAILURE TO COMPLY MAY RESULT IN SERIOUS INJURY AND MAY DAMAGE
THE EQUIPMENT. CAUTION MOST CLEANERS ARE HARMFUL TO THE SKIN, EYES, MUCOUS
MEMBRANES AND CLOTHING. PRECAUTIONS SHOULD BE TAKEN TO WEAR RUBBER GLOVES, GOGGLES OR FACE SHIELD AND PROTECTIVE CLOTHING. CAREFULLY READ THE WARNING AND FOLLOW THE DIRECTIONS ON THE LABEL OF
THE CLEANER TO BE USED
.
WHILE THE UNIT IS HOT.
It is recommended the fryer oil be kept as clean as possible by straining regularly (several times a day) and filtering daily. This will lengthen the life of your oil and improve the performance of the fryer.
Daily Severe Duty Cleaning
1. Turn power switch off.
2. Remove the baskets, let baskets drain and then set aside.
3. Raise heating elements out of oil and lock in up position.
4. Remove cap from oil drainpipe on bottom of fryer.
5. Place a suitable container under drainpipe.
6. Pull drain valve lever forward to open drain valve.
7. Remove loose food particles from heating units with spatula and wire brush.
8. Flush out scrapings and sediment with a small quantity of hot oil, and allow to drain thoroughly.
9. Close drain valve and fill with a commercial fryer cleaning agent or soapy solution of non-corrosive grease dissolving cleaner.
10. Lower heating elements and set selector switch to 250ºF (121ºC) (be sure to read and follow cleaner manufactures instructions) and boil solution for 15 to 20 minutes.
11. Turn power switch off.
12. Raise heating elements and lock in up position, then drain solution from well. Refill with water and add 1/2 cup of white vinegar to neutralize alkaline left by soap. Lower heating elements, bring solution to a boil, and let stand for a few minutes.
13. Turn power switch off.
14. Raise heating elements, lock in up position, drain well, and rinse with clear, hot water. Dry well and heating units thoroughly, and close drain valve.
15. Refill fryer with oil, and lower heating elements slowly.
16. Operate fryer as normal.
Over-Temperature Protection
The over-temperature thermostat located next to the left heating element provides protection in case of malfunction of the main temperature control. It will open both the “control contactor” and the “safety contactor” removing all power from the heating elements.
10
Page 11
Maintenance & Cleaning Cont’d
Thermostat Bulb Check
The two thermostat bulbs, (temperature control thermostat bulb and over-temp thermostat bulb), are all connected to the fryer heating elements. The brackets that hold these bulbs in place should be checked on a regular basis for tightness. If any of the brackets/bulbs become loose, the brackets that hold the bulbs should be tightened right away.
Component Access
All maintenance may be done from the front. Opening the front by removing 4 bolts gains access to all circuitry, with the exception of the thermostat, which is located on the top where the thermostat knob is located. To gain access to the safety thermostat, the thermostat, and element terminals remove the 4 screws from the front of the access cover located above and to the rear of the oil well.
11
Page 12
Troubleshooting
Symptoms
What follows is a chart of Symptoms and Possible Causes to aid in diagnosing faults with the oven. Refer to the Symptoms column to locate the type of failure then to the Possible Cause for the items to be checked. To test for a possible cause, refer to the TEST section and locate the Possible Cause then refer to test to identify test procedures.
Symptom Possible Cause
No power to cord outlet Fryer unplugged from outlet
Power indicator is not lit
Fryer will not heat
Product burning
Product under done
Heat indicator is not lit
Failed power cord or plug Failed power switch Failed pilot light
Failed element Power switch is not ON Failed contactor Failed thermostat Failed transformer Tripped over temperature thermostat Product is cooked too long Failed thermostat Failed contactor
Failed temperature sensor Failed circuit board Failed temperature selector
Failed heat light Failed thermostat Failed contactor
Overtemp. indicator is not lit
Overtemp. indicator is lit
Failed indicator light Normal
Overtemp. thermostat tripped Failed indicator light Failed overtemp. thermostat
12
Page 13
Troubleshooting Cont’d
TESTS
NOTICE Service on this or any other, Lang appliance must be performed
by qualified personnel only. Consult your authorized service agent directory or call the factory at (314) 678-6315 or visit our
website
WARNING: BOTH HIGH AND LOW VOLTAGES ARE PRESENT INSIDE
THIS APPLIANCE WHEN THE UNIT IS PLUGGED/WIRED INTO A LIVE RECEPTACLE. BEFORE REPLACING ANY PARTS, DISCONNECT THE UNIT FROM THE ELECTRIC POWER SUPPLY.
If an item on the list is followed by an asterisk (*), the work should be done by a factory authorized service representative.
www.langworld.com For the service agent nearest you.
Possible Cause Test
Product is cooked too long Failed thermostat
Failed element
Failed heat contactor
Failed or disconnected safety thermostat
No test available, operational condition Check poles on thermostat for continuity
Remove the wires and check for continuity across the element Remove the wires from the contactor coil and check for
continuity across the contactor coil connection Ensure the contactor moveable points move freely up and down Check for 24 volts at the contactor coil when the computer is running*
Check across the thermostat connectors for continuity
CAUTION: USE OF ANY REPLACEMENT PARTS OTHER THAN THOSE SUPPLIED BY LANG
OR THEIR AUTHORIZED DISTRIBUTORS CAN CAUSE BODILY INJURY TO THE OPERATOR AND DAMAGE TO THE EQUIPMENT AND WILL VOID ALL WARRANTIES.
13
Page 14
Parts List May 21, 2013, Rev B
Model: CL130FFF Fryer
Item # Part NO. Description Qty Application
1 O9-C28-002-CL BODY W\STAND ASSY FOR IPK 1 2 O9-C28-503-CL FRONT ASSY [ETCHED] 1 3 O9-C28-505-CL DRAIN CAP ASSY 1 4 O9-C28-108-1-CL FRYER DRAIN COVER 1 5 2K-70302-25 PIPE NIPPLE 1X4 S/S 1 6 2K-70304-06 STREET ELBOW 90 DEG S/S 1 1 7 2V-70400-01 VALVE 1BALL NIC PLTD (NO 1 8 O9-C28-545-CL DRAIN VALVE BRKT ASSY 1
9 O9-C28-547-CL DRAIN VALVE ROD ASSY 1 10 2C-20106-01 SCRWSHLDR 5/16X1/2 1/4-20 1 11 O9-C28-163 LIFT HANDLE 1 12 O9-C28-205-CL SMOTHER 1 13 O9-C28-136-CL HEAD PIVOT SUPPORT-CRUISE 1 14 O9-C28-540-CL STANCHION TRIM LOCK 2 15 O9-C28-137-CL HEAD PIVOT-CRUISE LINE 1 16 2C-71801-03 COTTER PIN 3/32X1-1/2 S/S 2 17 2I-71100-03 RBBR-LOCK AL 100-1/16 B-7 3 18 O9-C28-508-2-CL WIRE COVER 1 19 O9-C28-506-CL BODY BACK 1 20 2E-30500-11 TRM BLOCK 2 PLE LG 175AMP 2 21 PS-60101-W13 FRYER SWITCH & CNTACT BLK 1 23 2E-30700-03 CONTC 3POLE 40A208-240VAC 2 24 2E-30900-01 FUSE 15AMP (ABC-15) 2 25 2E-30901-02 FUS HLDR FOR 15AMP FUSE 2 26 2E-31400-04 XFRMR 480/240VAC 100VA 1 27 2E-31800-07 CB 2/10 AMP 2 POLE 1 28 2T-30401-19 STAT FXD TMP NEGBIAS 425o 2 29 2J-31601-01 PILOT LT 250V 6LEAD BLK 3 30 2T-30402-12 STAT ADJ 400o 24 C/T 1 31 O9-70701-06 KNOB ASSY C28 TEMP CNTRL 1 32 O9-C28-560-CL HRNSS CLF-15FRYR 220/440V 1 33 O9-C28-542-CL WIREWAY TOP TRIM LOCK 4 34 O9-C28-537-CL WIREWAY SIDE TRIM LOCK 4 35 O9-C28-527-CL COMPONENT MOUNT ASSY 1 36 O9-C28-164-CL ELEMENT CLIP, 7 37 O9-C28-165-CL ELEMENT CLIP, 4 38 O9-C28-166-CL #N/A 4 39 O9-C28-167-CL LARGE BULB CLIP-CRUISE 4 40 O9-C28-168-CL SMALL BULB CLIP-CRUISE 2 41 O9-C28-168-1-CL LIMIT STAT BULB SPACER 2 42 O9-C28-160-CL ELEMENT WASHER-CRUISE 6 43 O9-C28-131-2 OVERTEMP STAT INSULATOR 1 44 O9-C28-131-1-CL OVERTEMP STAT 2 45 O9-C28-161 ELEMENT CLAMP REAR 1 46 2N-11110-47 ELMNT FRYER 440V 4KW C28 3 47 2C-20303-14 NUT HX SS 5/8-18 JAM 6 48 O9-C28-531-CL BASKET HANGER ASSY 1 49 O9-C28-130-2-CL HEAD WRAP ASSY NON-OSB - 1 50 2B-50600-09 FRYR BSKET TWN C28,30,40 2 51 2A-72901-14 FOOT 3ADJ W/BOLT DOWN MAR 4 51 2A-72500-12 LEG W/ROUND ADJ TOE 4 CL130FFF-440V 52 2E-30500-01 TRM STRP 2 POLE 30A 300V 2 CL130FFB-440V
14
Page 15
53 2J-30802-01 BUZZER-MECHANICAL 240VAC 1
N/S 2B-51100-41 BASKET HANGER 1 N/S 2J-30801- 02 TIMER MECH.15 MINUTE SING 1 N/S 2K-70801-05 SNAP BUSH STRAIN RELIEF 3
15
Page 16
16
Page 17
28
52
53
17
Page 18
18
Page 19
1
.PMET REVO
1L 2L
3L
F
H
H
4X
2H
GNIRIW DAEH
E
084
042
REWOP
G
3
5
4
6
2
12
1X
1H
CN
ON
CN
ON
A
AB
B
A
B
MOC
MOC
MOC
BLUB
BLUB
TAEH
BLUB
EP
: YB .KHC
01
11
21
01
11
21
DACA MORF
: YB .VER
:VER
ESAHP 3 ,CAV044 S-51L-FLC & S-51-FLC
30-13116
F
: ETAD .VER
gnirutcafunaM
A
C
D
D
C
A
FO
B
1
E
B
2
34
5
6
7
8
9
1
2
3
4
5
6
7
8
9
: YB .NWD
: ELIF DAC
: ETAD .KHC
G
1
1
: ETAD .NWD
:NOITPIRCSED
02
02
22
72
62
42
52
42 52
12
32
32
64
64
64
03
82
92
92
92
13
23
02
GLD
:ON .GWD
20-11-21
B
TEEHS
ynapmoC
Page 20
Lang Manufacturing Limited Warranty to Cruise Line Purchasers
Lang Manufacturing Equipment (“Lang Equipment”) has been skillfully manufactured, carefully inspected and packaged to meet rigid standards of excellence. Lang warrants its Equipment to be free from defects in material and material-related workmanship for (13) thirteen consecutive months from the date of initial shipboard installation or (18) eighteen consecutive months from date of initial factory shipment, which ever comes first. The aforementioned warranty statement is subject to the following conditions and limitations.
III. Replacement components will be shipped F.O.B. factory with freight prepaid. Replacement component damage related to shipment is not covered under this warranty.
IV. This warranty does not cover consumable parts such as quartz elements, and does not cover defects caused by improper installation, abuse, careless operation, or improper maintenance of Product.
Warranty
I. This warranty is limited to the provision of
replacement components for Product sold by Lang to a joiner company for installation aboard a cruise ship, or a cruise ship company for installation aboard its own ship. The provision of replacement components to affect Product repairs will be on a no-charge basis during the term of the warranty. Replacement components will be sent to the address required within 48 hours of Lang receiving written notification of the description of the defect and the model and serial number of the Product affected by the repair.
Quartz elements are warranted for ninety (90) days from the date of installation.
II. Damage during shipment is to be reported to the carrier, is not covered under this warranty, and is the sole responsibility of purchaser/user.
V. All warranties are conditioned upon Lang’s receipt of written notice of any defect prior to the end of the applicable warranty period.
VI.
THIS WARRANTY IS EXCLUSIVE AND IS IN
LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, EACH OF WHICH IS HEREBY EXPRESSLY DISCLAIMED. THE REMEDIES DESCRIBED ABOVE ARE EXCLUSIVE AND IN NO EVENT SHALL LANG BE LIABLE FOR SPECIAL, CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR THE BREACH OR DELAY IN PERFORMANCE OF THIS WARRANTY.
VII. Lang Equipment is for cruise line use only. If sold as a component of another (OEM) manufacturer’s equipment, or if used as a consumer product, such Equipment is sold AS IS and without any warranty.
20
Loading...