Intended to alert the user to the presence of uninstalled "dangerous voltage" within the product's enclosure
that may be of sufficient magnitude to constitute a risk of electric shock to persons.
Intended to alert the user of the presence of important operating and maintenance (servicing) instructions in
the literature accompanying the product.
Caution: Risk of electrical shock - DO NOT OPEN!
Caution: To reduce the risk of electrical shock, do not remove cover. No user servicable parts inside. Refer servicing to
qualified service personnel.
WARNING: To prevernt electrical shock or fire hazard, do not expose this appliance to rain or moisture. Before using this
appliance, read the operating guide for further warnings.
This apparatus must be earthed.
EMC warning
It is inherent in the design of a loudspeaker and in the design of guitar pickups that they should emit or be affected by electro magnetic fields. Loudspeaker enclosures should not
be used less than two meters away from equipment, which is likely to be affected by electro magnetic interference.
Likewise, guitar fitted with electro magnetic pickups should not be used less than two meters away from any source of emissions such as loudspeakers. Emissions from
loudspeakers are dependent on the frequency characteristics of the drive unit. Levels were measured direct from the driver of 30 dBuV. These levels are reduced to a safe level at
a distance of 1,27 meters from the drivers.
IMPORTANT SAFETY INSTRUCTIONS
WARNING: When using electric products, basic cautions should always be followed, including the following.
1.Read all safety and operating instructions before using this product
2.All safety and operating instructions should be retained for future reference
3.Obey all cautions in the Operating instructions and on the back of the unit
4.All operating instructions should be followed
5.This product should not be used near water, i.e. a bathtub, sink, swimming pool, wet basement, etc.
6.This product should be located so that its position does not interfere with its proper ventilation. It should not be placed
flat against a wall or placed in a built up enclosure that will impede the flow of cooling air.
7.This product should not be placed near a source of heat such as stove, radiator, or another heat producing amplifier.
8.Connect only to a power supply of the type marker on the unit adjacent to the power supply cord.
9.Never break off the ground pin on a power supply cord.
10.Power supply cords should always be handled carefully. Never walk or place equipment on power supply cords.
Periodically check cords for cuts or signs of stress, especially at the plug and the point where the chord exits the unit.
11.The power supply cord should be unplugged when the unit is to be unused for long periods of time.
12.If this product is to be mounted in an equipment rack, rear support should be provided.
13.Metal parts can be cleaned with a damp cloth. The vinyl covering used on some units can be cleaned with a damp
cloth or ammonia based household cleaner if necessary. Disconnect the unit from the power supply before cleaning.
14.Care should be taken so that objects do not fall and liquids are not spilled into the unit through any ventilation holes or
openings.
15.A qualified service technician should check the unit if:
The power cord has been damaged
Anything has fallen or spilled into the unit
The unit does not appear to operate correctly
The unit has been dropped or the enclosure damaged.
16.The user should not attempt to service the equipment. All service work is done by a qualified service technician.
17.Exposure to extremely high noise levels may cause a permanent hearing gloss. Individuals very considerably in
susceptibility to noise induced hearing loss, but nearly everyone will lose some hearing if exposed to sufficiently intense
noise for a sufficient time. The U.S. Government's Occupational Safety and Health Administration (OSHA) has
specified the following permissible noise level exposure.
Duration Per Day In HoursSound Level dBA, slow response
According to OSHA, any exposure in excess of the above permissible limits could result in some hearing loss. Ear plugs or
protectors in the ear canals or over the ears must be worn when operating this amplification system in order to prevent a
permanent hearing loss if exposure exceeds the limits set forth above. To ensure against potentially dangerous exposure to
high sound pressure levels it is recommended that all persons exposed to equipment capable of producing high sound
pressure levels such as this amplification system be protected by hearing protectors while this unit is in operation.
SAVE THESE INSTRUCTIONS
Laney
1.
1
INTRODUCTION
Congratulations on your decision to purchase a Laney amplifier.
Laney products are designed with ease of operation as a primary objective, however to ensure you
derive the best from your new amplifier, it is important you take time to read this user manual and to
familiarise yourself with the control functions and facilities available
BEFORE
SWITCHING ON
After unpacking your amplifier check that it is factory fitted with a three pin 'grounded' (or earthed) plug.
Before plugging into the power supply ensure you are connecting to a grounded earth outlet.
If you should wish to change the factory fitted plug yourself, ensure that the wiring convention applicable to
the country where the amplifier is to be used is strictly conformed to. As an example in the United Kingdom
the cable colour code for connections are as follows.
EARTH OR GROUND - GREEN/YELLOW
NEUTRAL - BLUE
LIVE - BROWN
This manual has been written for easy access of information. The front and rear panels of each unit
are graphically illustrated, with each control and feature numbered. For a description of the function of
each control feature, simply check the number with the explanations adjacent to each panel.
Your Laney amplifier has undergone a thorough two stage, pre-delivery inspection, involving actual
play testing, as well as burn in.
When you first receive your Laney amp, follow these simple procedures:
(I) Ensure that the amplifier is set at the correct voltage for the country it is to be used in.
(ii) Connect your instrument with a high quality instrument cable. Use of cheap cables will compromise
the sound of your instrument and your amplifier.
If there is a problem with your Laney amplifier
DON'T
DO
PHONE YOUR DEALER!
Care of your Laney amplifier will prolong it's life.....and yours!.
Laney
HCP804 Front
1.
2
ToneTone
ReverbReverbReverbReverb
55
44
33
22
11
55
44
33
22
11
VolumeVolume
55
44
66
101000
66
101000
66
77
33
88
22
11
99
101000
77
88
11
99
MicMicMicMicMicMicMicMic
HCP804 Rear
Made In ChinaMade In China
Warning
Warning
This Equipment must be earthed.
This Equipment must be earthed.
Supply VoltageSupply Voltage
~115V
~230V
Power Consumption
Power Consumption
~50-60Hz
~50-60Hz
160Watts160Watts
ToneToneToneToneToneTone
55
44
77
33
88
22
11
99
55
44
33
22
11
VolumeVolume
55
44
66
101000
66
101000
66
77
99
77
99
77
33
88
88
88
22
11
22
22
99
101000
22
VolumeVolumeVolumeVolume
ReverbReverbReverbReverb
55
44
66
77
33
11
33
11
33
88
22
11
99
101000
55
44
66
77
88
99
101000
LineLineLineLineLineLineLineLine
Warning
Warning
To reduce the risk of fire or electric shock do not
To reduce the risk of fire or electric shock do not
expose this appliance to rain or moisture.
expose this appliance to rain or moisture.
Attention.
Debrancher le cordon d’alimentation avant toute intervention.
Debrancher le cordon d’alimentation avant toute intervention.
To reduce the risk of electric shock do not remove covers.
To reduce the risk of electric shock do not remove covers.
Attention.
Avis
Avis
Risque de choc electrique - ne pas ouvrir.
Risque de choc electrique - ne pas ouvrir.
Caution
Caution
No user serviceable parts inside.
No user serviceable parts inside.
Refer servicing to qualified personnel only.
Refer servicing to qualified personnel only.
Warning
Warning
This equipment must be earthed.
This equipment must be earthed.
55
44
66
77
88
99
101000
33
LoudSpeaker OutputsLoudSpeaker Outputs
4 ohms
4 ohms
Total Minimum Load
Total Minimum Load
55
44
33
22
11
55
44
33
22
11
55
44
66
101000
66
101000
66
77
99
77
99
77
33
88
88
88
22
11
99
101000
44
BassBass
55
44
33
22
11
55
44
33
22
11
VolumeVolume
Main
Main
Out
Out
In OutIn Out
LL
MidMid
44
66
77
33
88
22
11
99
101000
44
66
77
33
88
22
11
99
101000
ReverbReverb
Powered MixerPowered Mixer
Reverb
Reverb
Out
Out
TapeTape
LL
TrebleTreble
55
66
101000
55
66
101000
Aux
Aux
55
44
66
77
88
99
77
88
99
In
In
77
33
88
22
11
99
101000
55
44
66
77
33
88
22
11
99
101000
TapeTape
Foot
Foot
Switch
Switch
Designed in the United Kingdom
Designed in the United Kingdom
by BLT Industries Ltd.
by BLT Industries Ltd.
Model - HCP804Model - HCP804
PowerPower
11
00
HCP804HCP804
LaneyLaney
RRRR
HCP804 Channel features
ToneTone
ReverbReverb
55
44
33
1
2
22
11
55
44
33
22
11
VolumeVolume
3
LineLine
55
44
66
101000
66
101000
66
77
99
77
99
77
33
88
88
88
22
11
99
101000
11
MicMic
TONE: Sets the overall tonal quality of the channel
1
input. The greater the tone value the more treble
4
present in the signal, giving a brighter sound...
VOLUME: Sets the level of the individual channel in
2
relation to the rest of the channels - used in
conjunction with the master volume level.
LINE INPUT: Socket for connecting line level input
3
5
signals from units such as drum machines or
sequencers.
REVERB: Sets the level of reverb for the individual
4
channel input.
5
XLR SOCKET: Socket provided for connecting XLR
equipped microphones.
Laney
HCP804 Master Section
6
BASS: Controls the low frequency
EQ in the over all signal.
7
VOLUME: Controls the overall
listening volume of the amplifier.
MAIN: A line level output, for
8
connection to another amplifier or
desk, etc. This takes the signal from
after the ‘Master’ volume control,
unlike the ‘Rec Out’, which is
unaffected by the overall listening
level of the amp.
1.
3
9
BassBass
55
44
6
7
33
22
11
55
44
33
22
11
VolumeVolume
8
Main
Main
Out
Out
MidMid
44
66
77
33
88
22
11
99
101000
44
66
77
33
88
22
11
99
101000
ReverbReverb
Powered MixerPowered Mixer
Reverb
Reverb
Out
Out
TrebleTreble
55
66
101000
55
66
101000
55
44
66
33
22
11
33
22
44
11
TapeTape
77
88
99
101000
55
66
77
88
99
101000
77
88
99
77
88
99
11
00
PowerPower
10
11
HCP804HCP804
Aux
Aux
In
In
Foot
Foot
Switch
Switch
LaneyLaney
12
9
MIDDLE: Global Mid Range EQ. This adjusts the
13
15
14
mid range frequency response across the entire mix.
10
TREBLE: Global Treble EQ. This adjusts the high end frequency response across the entire mix.
11
TAPE: Sets the overall level of the signal connected to the tape input on the rear of the HCP804.
FOOTSWITCH: Jack socket for connecting an optional Laney FS1 footswitch, for switching reverb
12
on/off.
AUX IN: Jack socket line in, designed to work in conjunction with the ‘Reverb Out’ socket, as the
13
return of an effects loop or some such device.
14
REVERB: Controls the overall reverb output level across the entire mix.
REVERB OUT: Jack socket providing a line level signal for each individual channel. The level of
15
the signal present from each channel is determined by the channels individual REVERB setting
level. The REVERB OUT can be used to generate a line level output that can be used in
conjunction with the AUX IN socket as an effects loop.
HCP804 Rear Panel
Made In ChinaMade In China
This Equipment must be earthed.
This Equipment must be earthed.
Warning
Warning
Supply VoltageSupply Voltage
~115V
~230V
Power Consumption
Power Consumption
~50-60Hz
~50-60Hz
160Watts160Watts
Warning
Warning
To reduce the risk of fire or electric shock do not
To reduce the risk of fire or electric shock do not
expose this appliance to rain or moisture.
expose this appliance to rain or moisture.
Attention.
Debrancher le cordon d’alimentation avant toute intervention.
Debrancher le cordon d’alimentation avant toute intervention.
To reduce the risk of electric shock do not remove covers.
To reduce the risk of electric shock do not remove covers.
Attention.
Avis
Avis
Risque de choc electrique - ne pas ouvrir.
Risque de choc electrique - ne pas ouvrir.
Caution
Caution
No user serviceable parts inside.
No user serviceable parts inside.
Refer servicing to qualified personnel only.
Refer servicing to qualified personnel only.
Warning
Warning
This equipment must be earthed.
This equipment must be earthed.
LoudSpeaker OutputsLoudSpeaker Outputs
4 ohms
4 ohms
Total Minimum Load
Total Minimum Load
16
TapeTape
In OutIn Out
LL
RRRR
17
18
Designed in the United Kingdom
Designed in the United Kingdom
by BLT Industries Ltd.
LL
by BLT Industries Ltd.
Model - HCP804Model - HCP804
Laney
HCP804 Rear Panel
16
SPEAKER OUTPUTS: Twin jack sockets for connection of loudspeaker cabinets. The HCP804 will
deliver 80 watts of output power into a 4 ohm load. Under no circumstances should the total load
seen by the amp fall below 4 ohms. This would result in temporary thermal shutdown, which, after
continued use under these conditions, may impair the long term reliability of the amplifier.
TAPE INPUT: Dual phono, line level input sockets, ideal for connecting a CD player or tape
17
machine to the amplifier. The level of the signal from the unit connected to the tape input is
determined by the Tape input control on the front panel (11)
TAPE OUT: Dual phono, line level output sockets, ideal for connection to an external recording
18
device, i.e., DAT player, Mini Disc recorder, Tape machine, etc.