Laney Amplification CP10 User Manual

Laney
Series monitors
MODEL : CP10
CP12 CP15 CM10 CM12 CM15
USER MANUAL
revision 1.1
Concept
Intended to alert the user to the presence of uninstalled "dangerous voltage" within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
Intended to alert the user of the presence of important operating and maintenance (servicing) instructions in the literature accompanying the product.
Caution: Risk of electrical shock - DO NOT OPEN! Caution: To reduce the risk of electrical shock, do not remove cover. No user servicable parts inside. Refer servicing to
qualified service personnel. Warning: This apparatus must be earthed
WARNING: To prevernt electrical shock or fire hazard, do not expose this appliance to rain or moisture. Before using this appliance, read the operating guide for further warnings.
EMC warning
It is inherent in the design of a loudspeaker and in the design of guitar pickups that they should emit or be affected by electro magnetic fields. Loudspeaker enclosures should not be used less than two meters away from equipment, which is likely to be affected by electro magnetic interference. Likewise, guitar fitted with electro magnetic pickups should not be used less than two meters away from any source of emissions such as loudspeakers. Emissions from loudspeakers are dependent on the frequency characteristics of the drive unit. Levels were measured direct from the driver of 30 dBuV. These levels are reduced to a safe level at a distance of 1,27 meters from the drivers.
IMPORTANT SAFETY INSTRUCTIONS
WARNING: When using electric products, basic cautions should always be followed, including the following.
1. Read all safety and operating instructions before using this product
2. All safety and operating instructions should be retained for future reference
3. Obey all cautions in the Operating instructions and on the back of the unit
4. All operating instructions should be followed
5. This product should not be used near water, i.e. a bathtub, sink, swimming pool, wet basement, etc.
6. This product should be located so that its position does not interfere with its proper ventilation. It should not be placed flat against a wall or placed in a built up enclosure that will impede the flow of cooling air.
7. This product should not be placed near a source of heat such as stove, radiator, or another heat producing amplifier.
8. Connect only to a power supply of the type marker on the unit adjacent to the power supply cord.
9. Never break off the ground pin on a power supply cord.
10. Power supply cords should always be handled carefully. Never walk or place equipment on power supply cords. Periodically check cords for cuts or signs of stress, especially at the plug and the point where the chord exits the unit.
11. The power supply cord should be unplugged when the unit is not in use and during lightning storms.
12. If this product is to be mounted in an equipment rack, rear support should be provided.
13. Metal parts can be cleaned with a damp cloth. The vinyl covering used on some units can be cleaned with a damp cloth or ammonia based household cleaner if necessary. Disconnect the unit from the power supply before cleaning.
14. Care should be taken so that objects do not fall and liquids are not spilled into the unit through any ventilation holes or openings. CAUTION - on no account place drinks on the unit.
15. A qualified service technician should check the unit if:
The power cord has been damaged Anything has fallen or spilled into the unit The unit does not appear to operate correctly The unit has been dropped or the enclosure damaged.
16. The user should not attempt to service the equipment. All service work is done by a qualified service technician.
17. Exposure to extremely high noise levels may cause a permanent hearing gloss. Individuals very considerably in susceptibility to noise induced hearing loss, but nearly everyone will lose some hearing if exposed to sufficiently intense noise for a sufficient time. The U.S. Government's Occupational Safety and Health Administration (OSHA) has specified the following permissible noise level exposure.
Duration Per Day In Hours Sound Level dBA, slow response
8 90 6 92 4 95 3 97 2 100 1 ½ 102 1 105 ½ 110 ¼ or less 115
According to OSHA, any exposure in excess of the above permissible limits could result in some hearing loss. Ear plugs or protectors in the ear canals or over the ears must be worn when operating this amplification system in order to prevent a permanent hearing loss if exposure exceeds the limits set forth above. To ensure against potentially dangerous exposure to high sound pressure levels it is recommended that all persons exposed to equipment capable of producing high sound pressure levels such as this amplification system be protected by hearing protectors while this unit is in operation.
SAVE THESE INSTRUCTIONS
Concept
THANK YOU
We at Laney are extremely pleased that you have decided to select a Concept product for your sound requirements and we wish to reinforce your judgement by ensuring you get off to a flying start by including this comprehensive user manual to assist you in getting to know your equipment.
Before switching on please read this manual carefully since whilst you may well be an experienced user no two brands are the same, and on reading this manual you will become aware of the subtle advantageous differences that Concept offers over its competitors.
UNPACKING
On unpacking your Concept please check carefully for any signs of damage that may have occurred whilst in transit from the Laney factory to your dealer. In the unlikely event that there has been damage please repack your unit in its original carton and consult your dealer.
We would strongly advise you to store away your original transit carton since in the unlikely event that some time in the future your unit should develop a fault, you will be able to return it to your dealer for rectification securely packed.
2
IMPORTANT SAFETY INFORMATION
Your Concept powered monitors product should be fitted with a three pin 'grounded' (or 'earthed') plug. Please make sure that the mixer is powered from a 'grounded/earthed' outlet.
If changing or fitting a plug yourself, ensure that the applicable wiring code is adhered to, for example in the UK the cable colour code for connections are as follows:
EARTH OR GROUND NEUTRAL LIVE
The Concept product should never be exposed to moisture or wetness under any circumstances since this would represent a possible shock or fire hazard, and may cause expensive damage to your valuable possession.
In the unlikely event that a fuse should blow, it is imperative that you or your engineer, use a correctly rated replacement.
Details of the fuse required is printed on the powered monitor, please take special care to use a 'time delay' fuse wherever stated.
GREEN/YELLOW BLUE BROWN
CP Manual
Concept
CP10
3
CP10CP10
1
2
4
5
6
3
33
22
11
22
33
44
22
33
44
55
44 66
00
- 0+- 0+
111111
55
- 0+- 0+
55
1010
55
11
55
MicMic
LineLine
LinkLink
77
88
VolumeVolume
99
22
33
TrebleTreble
44
22
33
BassBass
44
EXPLANATION OF TERMS
MIC: Jack socket for connecting an
1
external Mic.
LINE: Jack input socket for all line level
2
signals e.g.: Keyboard, mic or drum machine.
LINK: Socket for connecting additional
3
power monitor or power amplifier.
VOLUME: Controls the overall listening
4
level of the monitor.
TREBLE: Adjusts the monitors HI
5
frequency response.
BASS: Adjusts the monitors LO frequency
6
response.
EXTERNAL SPEAKER: Output socket
7
for connect further un powered Laney monitor such as CM10, CM12 or CM15.
POWER: Power On/Off switch.
8
7
8
Ext.
Ext.
Speaker
Speaker
8 Ohms Min8 Ohms Min
Caution - To reduce the risk of fire hazard
Caution - To reduce the risk of fire hazard
replace fuse with same type and rating only.
replace fuse with same type and rating only.
Caution - To reduce the risk of electric shock
Caution - To reduce the risk of electric shock
do not remove covers. No user serviceable
do not remove covers. No user serviceable
parts inside.Refer servicing to qualified
parts inside.Refer servicing to qualified
personnel only.
personnel only.
Warning - To reduce the risk of fire or electric
Warning - To reduce the risk of fire or electric
shock do not expose this appliance to rain
shock do not expose this appliance to rain
or moisture.
or moisture.
CAUTIONCAUTION
CAUTIONCAUTION
RISK OF ELECTRIC SHOCK DO NOT OPENRISK OF ELECTRIC SHOCK DO NOT OPEN
RISK OF ELECTRIC SHOCK DO NOT OPENRISK OF ELECTRIC SHOCK DO NOT OPEN
Made in ChinaMade in China
Maximum Power Consumption
Maximum Power Consumption
Supply voltage
Supply voltage
Warning - This equipment must be earthed.Warning - This equipment must be earthed.
Serial No:Serial No:
130 Watts ~50/60 Hz
130 Watts ~50/60 Hz
11 00
11 00
~115V
& fuse rating
& fuse rating
Designed in the United Kingdom
Designed in the United Kingdom
by BLT Industries Ltd.
by BLT Industries Ltd.
~115V
~230V
~230V
T2A
T2A
T1A
T1A
!!
!!
CP Manual
Concept
CP12
4
CP12CP12
1
2
3
4
5
6
7
8
22
33
33
33
PowerPower
33
11
22
44
22
44
22
44
55
44 66
00
- 0+- 0+
11
55
- 0+- 0+
11
55
- 0+- 0+
11
55
1010
11
55
11
55
11
55
MicMic
LineLine
LinkLink
77
88
VolumeVolume
99
22
33
TrebleTreble
44
22
33
MidMid
44
22
33
BassBass
44
Ext.
Ext.
Speaker
Speaker
8 Ohms Min8 Ohms Min
EXPLANATION OF TERMS
MIC: XLR iInput for LO impedance
1
microphones (200-600Ohm).
LINE: Jack input socket for all line level
2
signals e.g.: Keyboard, mic or drum machine.
LINK: Socket for connecting additional
3
power monitor or power amplifier.
VOLUME: Controls the overall listening
4
level of the monitor.
TREBLE: Adjusts the monitors HI
5
frequency response.
MIDDLE: Adjusts the monitors MID
6
frequency response.
BASS: Adjusts the monitors LO frequency
7
response.
EXTERNAL SPEAKER: Output socket
8
for connect further un powered Laney monitor such as CM10, CM12 or CM15.
9
POWER: Power On/Off switch.
9
CAUTIONCAUTION
CAUTIONCAUTION
RISK OF ELECTRIC SHOCK DO NOT OPENRISK OF ELECTRIC SHOCK DO NOT OPEN
RISK OF ELECTRIC SHOCK DO NOT OPENRISK OF ELECTRIC SHOCK DO NOT OPEN
Caution - To reduce the risk of fire hazard
Caution - To reduce the risk of fire hazard
replace fuse with same type and rating only.
replace fuse with same type and rating only.
Caution - To reduce the risk of electric shock
Caution - To reduce the risk of electric shock
do not remove covers. No user serviceable
do not remove covers. No user serviceable
parts inside.Refer servicing to qualified
parts inside.Refer servicing to qualified
personnel only.
personnel only. Warning - To reduce the risk of fire or electric
Warning - To reduce the risk of fire or electric
shock do not expose this appliance to rain
shock do not expose this appliance to rain
or moisture.
or moisture.
Attention - Debrancher le cordon d’alimentation
Attention - Debrancher le cordon d’alimentation
avant d’ouvrir l’appareil.
avant d’ouvrir l’appareil.
Attention - Remplacer le fusible par le
Attention - Remplacer le fusible par le
meme et le calibre.
meme et le calibre. Warning - This equipment must be earthed.Warning - This equipment must be earthed. Made In ChinaMade In China
Serial No:Serial No:
Maximum Power Consumption
Maximum Power Consumption
240 Watts ~50/60 Hz
240 Watts ~50/60 Hz
11 00
11 00
Supply voltage
Supply voltage
& fuse rating
& fuse rating
Designed in the United Kingdom
Designed in the United Kingdom
~115V
~115V
~230V
~230V
by BLT Industries Ltd.
by BLT Industries Ltd.
T2A
T2A
T1A
T1A
!!
!!
CP Manual
Concept
CP15
5
CP15CP15
1
2
3
4
5
6
7
8
PowerPower
33
22
11
22
33
44
22
33
44
22
33
44
55
44 66
00
- 0+- 0+
11
55
- 0+- 0+
11
55
- 0+- 0+
11
55
1010
11
55
11
55
11
55
MicMic
LineLine
LinkLink
77
88
VolumeVolume
99
22
33
TrebleTreble
44
22
33
MidMid
44
22
33
BassBass
44
Ext.
Ext.
Speaker
Speaker
8 Ohms Min8 Ohms Min
EXPLANATION OF TERMS
MIC: XLR iInput for LO impedance
1
microphones (200-600Ohm).
LINE: Jack input socket for all line level
2
signals e.g.: Keyboard, mic or drum machine.
LINK: Socket for connecting additional
3
power monitor or power amplifier.
VOLUME: Controls the overall listening
4
level of the monitor.
TREBLE: Adjusts the monitors HI
5
frequency response.
MIDDLE: Adjusts the monitors MID
6
frequency response.
BASS: Adjusts the monitors LO frequency
7
response.
EXTERNAL SPEAKER: Output socket
8
for connect further un powered Laney monitor such as CM10, CM12 or CM15.
9
POWER: Power On/Off switch.
9
CAUTIONCAUTION
CAUTIONCAUTION
RISK OF ELECTRIC SHOCK DO NOT OPENRISK OF ELECTRIC SHOCK DO NOT OPEN
RISK OF ELECTRIC SHOCK DO NOT OPENRISK OF ELECTRIC SHOCK DO NOT OPEN
Caution - To reduce the risk of fire hazard
Caution - To reduce the risk of fire hazard
replace fuse with same type and rating only.
replace fuse with same type and rating only. Caution - To reduce the risk of electric shock
Caution - To reduce the risk of electric shock
do not remove covers. No user serviceable
do not remove covers. No user serviceable
parts inside.Refer servicing to qualified
parts inside.Refer servicing to qualified
personnel only.
personnel only.
Warning - To reduce the risk of fire or electric
Warning - To reduce the risk of fire or electric
shock do not expose this appliance to rain
shock do not expose this appliance to rain
or moisture.
or moisture.
Attention - Debrancher le cordon d’alimentation
Attention - Debrancher le cordon d’alimentation
avant d’ouvrir l’appareil.
avant d’ouvrir l’appareil. Attention - Remplacer le fusible par le
Attention - Remplacer le fusible par le
meme et le calibre.
meme et le calibre.
Warning - This equipment must be earthed.Warning - This equipment must be earthed. Made In ChinaMade In China
Serial No:Serial No:
Maximum Power Consumption
Maximum Power Consumption
300 Watts ~50/60 Hz
300 Watts ~50/60 Hz
11 00
11 00
Supply voltage
Supply voltage
& fuse rating
& fuse rating
Designed in the United Kingdom
Designed in the United Kingdom
~115V
~115V
~230V
~230V
by BLT Industries Ltd.
by BLT Industries Ltd.
T5A
T5A
T2A
T2A
!!
!!
CP Manual
Concept
6
Unpowered Monitors
The Laney range of unpowered monitors, the CM10,CM12 & CM15 are designed to compliment the CP range of products. Each CP monitor is capable of powering an unpowered monitor for maximum power output and sound covereage.
Each CM monitor is supplied with an input jack and a link out jack. The input jack should be used to recieve the signal from the External Speaker Socket on a CP10, CP12 or CP15, whilst the link out jack should be used only when the monitors are being powered by a dedictaed monitor power amplifier, for example when the mixing desk is sending a monitor signal to an additional power amplifier.
Depending upon the specification of the power amplifier it may be possible to link together a number of unpowered monitors to achieve the desired monitor spread. The impedance of each unpowered monitor is 8 Ohms.
CP Specifications
Line In input impedance Link Out Mic input impedance Nominal Line input level Nominal Mic input level Extension Loudspeaker Speaker Nom Impedance Speaker Size Speaker rating Output Power Weight Size (H*W*D)
CM Specifications
Speaker Nom Impedance Speaker Size Speaker rating Output Power Weight Size (H*W*D)
CP10
10Kohms Directly coupled to Line In 2Kohms Balanced
-10dBu
-20dBu 8 ohms minimum 8 ohms 10" + Piezo tweeter 65W 65W / 4 ohms 13Kg 350*460*250
CM10
8 ohms 10" + Piezo tweeter 65W 65W / 4 ohms 12Kg 350*460*250
CP12
10Kohms Directly coupled to Line In 2Kohms Balanced
-10dBu
-20dBu 8 ohms minimum 8 ohms 12" + Piezo tweeter 120W 120W / 4 ohms 19Kg 437*585*300
CM12
8 ohms 12" + Piezo tweeter 120W 120W / 4 ohms 18Kg 437*585*300
CP15
10Kohms Directly coupled to Line In 2Kohms Balanced
-10dBu
-20dBu 8 ohms minimum 8 ohms 15" + Piezo tweeter 150W 150W / 4 ohms 23Kg 467*655*325
CP15
8 ohms 15" + Piezo tweeter 150W 150W / 4 ohms 21Kg 467*655*325
BLT Industries Ltd., Newlyn Road, Cradley Heath, West Midlands. B64 6BE.
Tel: (0044) (0)1384 633821 Fax: (0044) (0)1384 639186
Web site: http://www.laney.co.uk
In the interest of continued product development BLT Industries Ltd. Reserves the
right to amend product specification without prior notification.
Loading...