MOUNTING AND CONNECTING THE DEVICE
TECHNICAL DATA
LANCOM WLC-4025+
LANCOM WLC-4100
Quick Reference Guide
a
Power
LCD display (rotating in two lines)
A Device name
A Firmware version
A Device temperature
A Date and time
A CPU load
A Memory usage
A Number of VPN tunnels
A Data transfer in reception direction
A Data transfer in transmission direction
A Number of authenticated access points
A Number of access points expected
(actively congured)
A Number of new discovered and not yet authenticated access points
A Number of expected access points not present
A SNTP status (when WLAN LED constantly red)
A SCEP status (when WLAN LED constantly red)
Please observe the following when setting up the device
A The mains plug of the device must be freely accessible.
A For devices to be operated on the desktop, please attach the adhesive rubber
A Do not rest any objects on top of the device
A Ensure that the ventilation slots at the back remain unobstructed
footpads
COM
Fan
WLAN
New APs
Config
CA
VPN
ETH1 ETH2 ETH3 ETH4
USB
a dcb
Conguration interface
b
Use the included serial conguration cable to connect the serial
interface (COM) to the serial interface of the device you want to
use for conguring / monitoring.
Ethernet interface
c
Use the cable with the kiwi-colored connectors to connect one
of the interfaces ETH1 to ETH4 to your PC or a LAN switch.
USB interface
d
You can use the USB interface to connect a compatible USB
cellular modem, a USB printer or a USB ash drive for device
conguration.
Power switch and power connector (device back side)
e
Supply power to the device via the supplied power cable.
f
Use the power switch to turn the device on or off.
A Mount the device into a 19” unit in a server cabinet using the provided screws and mounting brackets.
Unplug the power plug from the power socket to
ensure that the device is completely separated from
the power supply!
LANCOM WLC-4025+
E
F
Power
COM
WLAN
New APs
Fan
Lost APsCAVPN
a bc de f gh i
a Power
Off Device switched off
Green, permanently Device operational
Green / orange, blinking Conguration password not set. Without a
Red, blinking Charge or time limit reached
password the device’s conguration data
is unprotected.
b Fan
Green, permanently CPU temperature OK
Orange, permanently CPU temperature > 55°
Red, blinking Hardware failure of the fan or CPU
temperature > 60°; additional acoustic
signal
c COM
Off No session logged on for the serial
Green, permanently Serial conguration session logged on
Orange, ickering Data transmission during the conguration
conguration interface
session
d WLAN
Red, permanently The LANCOM WLAN controller is not yet
Green, permanently At least one active access point connected
Red, blinking The device is operational but not
operational; one of the following elements
is missing:
A Root certicate
A Device certicate
A Current time
A Entropy for the DTLS encryption
and authenticated.
connected to an active access point.
Config
ETH1 ETH2
e New APs
Orange, blinking At least one new access point for authenti-
cation has been found.
f Lost APs
Red, blinking At least one expected access point has not
been found.
g CA
Off Internal CA switched off
Green, permanently Internal CA switched on and ready
Red, permanently Internal CA switched on; an error has
Orange, permanently CA switched on and ready; request
occurred
pending
h VPN
Off No VPN connection active
Green, permanently VPN connection active
Green, blinking Establishing VPN connections
i ETH (one green and one yellow LED each)
Green off No networking device attached
Green, permanently Connection to network device operational,
Green, ickering Data transmission
Yellow off 1000 Mbps
Yellow, permanently 10 / 100 Mbps
no data trafc
Hardware
Power supply Internal power supply unit (110-230 V, 50-60 Hz)
Power consumption 30 W
Environment Temperature range 5 – 40 °C; humidity 0-95 %; non-condensing
Housing Robust metal housing, 19" 1U with mounting brackets, network connectors on the front
Number of fans 1
Interfaces
ETH 4 individual ports for 10 / 100 / 1000-Mbps Ethernet, Ethernet ports can be electrically
disabled in the LCOS conguration.
Each Ethernet port can be freely congured (LAN, WAN, monitor port, off). LAN ports operate
in bridge mode or isolated. Additionally, external DSL modems or termination routers can be
operated at the WAN port together with policy-based routing.
USB USB 2.0 Hi-Speed host port for connecting USB printers (USB print server), serial devices
(COM-port servers), USB data media (FAT le system), or supported mobile radio USB modems;
bi-directional data transfer available.
Serial Interface Serial conguration interface / COM port (8-pin Mini-DIN): 9,600 - 115,000 baud, suitable for
optional connection of analog / GPRS modems. Supports the internal COM-port server.
WAN protocols
Ethernet PPPoE, Multi-PPPoE, ML-PPP, PPTP (PAC or PNS) and plain Ethernet (with or without DHCP),
RIP-1, RIP-2, VLAN, IP
Declaration of conformity
Hereby, LANCOM Systems declares that this device is in compliance with Directives 2014/30/EU and 2014/35/EU.
The full text of the EU declaration of conformity is available at the following internet address:
www.lancom-systems.com/ce/
Package content
Documentation Quick Reference Guide (DE/EN), Installation Guide (DE/EN), FCC Documentation
Cables 1 Ethernet cable 3 m (kiwi-colored connectors), 1 serial conguration cable 1.5 m,
1 IEC power cord
Mounting brackets Two 19” brackets for rack mounting
LANCOM, LANCOM Systems and LCOS are registered trademarks. All other names or descriptions used may be trademarks or registered