Lamptron CW611 User Manual

Lamptron CW611 instruction manual
Thank you for choosing the LAMPTRON CW611 controller, this controller is designed & optimized for both air-cooled and water-cooled applications. For computer use only.
Large screen, narrow border design, clear and pleasing white on black, high-brightness backlight. Use of a knob and a secondary button will allow you to be able to use all of the functions easily. Each channel can be used in three optional modes of fan, pump and flow meter. Every channel is identified with an intuitive icon for each mode. Each channel can be individually set to manual mode (M) or automatic mode (A). Set the target temperature of the channel in automatic mode and you can specify the lowest output value and the highest output value per channel. If the actual temperature does not reach the target temperature, the output remains in the minimum set value, when the actual temperature exceeds the target temperature, the output begins to increase. Automatic control supports fans equipped with or without tachometers. Each of the 6 channels has a maximum output of 36 watts, which you can easily cycle using the knob. When a channel is placed in fan or water pump mode, you can set the channel to show voltage or speed units. Backlight brightness options of 20%, 50%, 80%, 100%, and OFF, so you can choose what suits you best. Each individual channel can turn on or off the alarm based on Celsius or Fahrenheit. Commonly used features and advanced functions are separated, press the knob for a short period to enter the frequently used functions of the current channel settings, or press it for a longer period to enter the advanced features of the current channel. Press the auxiliary key to navigate through the options while in that mode, one finished, press the knob for a shot period to return to the main interface.
INSTALLATION:
Instructions:
1. P: Standard Molex. Connect to your power supply. Tip: Be sure to use at least 18AWG wiring specifications.
2. P1 ~ P6: Channels 1 to 6 output interface (compatible fan, water pump, electronic flow meter), the six interfaces are standard with KF2510 3pin interfaces. Tip: You can also use a KF2510 4pin connector.
3. TEMP1 ~ TEMP6: are respectively connected to the P1~P6 secondary connectors corresponding to the sensors. Tip: Automatic control of each output channel is carried out according to the temperature reported by the temp sensors.
OPERATION:
CW611
1
2
Connect the power supply “P”, the controller goes into normal operation, and the screen will display “ ” logo; press Key or Key , Or rotate ; enter the main interface explained below:
1
Press and hold the knob to enter the settings of the current channel.
1
To enter the commonly used settings, press the knob for a short period. To enter the more advanced settings, press for a longer period. Rotate the knob to change the parameters accordingly. Press the knob for a short period to exit to the main screen.
2
Auxiliary keys used to confirm setting changes after selecting them within the menu (access explained in the previous point). In addition, in the main interface, press the auxiliary button can switch the backlight
2
brightness, backlight will be 100% > 80% > 50% > 20% > turn off the backlight > 20% > 50% > 80% > 100% of the sequence cycle.
11 12 13 14 15
10
9
CW611
6
1
2
1
SPECIFICATIONS:
Dimension LCD Dimension Power Output Control Channel Color Available DC Input DC Output Connectors
148.5mm * 42.5mm * 63mm 118mm * 31mm(wide screen) Up to 36 watts per channel 6 Channels Black Anodized/Silver + 12V(Standard “D” Connector 0V - 12V DC 6pcs 3pin connectors
Installation location:
The CW611 is designed to fit in a 5.25” bay, please use the included screws to install it within your pc case. (Phillips screwdriver required and not included)
CONNECTIONS:
2
34 85 7
4 5 6 7
3
Show channel 1~6 icon, position for the selected channel,You can use the knob clockwise or counter-clockwise rotation to rotate through the channels. Icons . Each channel can
8
1
3
34567
choose one in three operational modes. The default is fan mode when you first start your CW611:
Fan Water Pump Electronic Flow Meter
9
Shows current operational mode.
10
11
and represent the output of that channel, value, units,
10
11
You can choose speed (RPM), voltage (Vol), or flow units (LPH GPM), the default is speed (RPM). Tip: Only in the channel used by the electronic flowmeter can you choose the flow unit, fan and pump modes can only use speed (RPM) or voltage (Vol) units.
12
Alarm icon, The default is off (which will show , when turned on, it´ll show . Each channel can be individually turned on or off (in terms of the Alarm).
13
The temperature values of the currently selected channel. Temperature unit, the default is Celsius but can be changed to
14
Fahrenheit . Each channel can be individually defined.
15
Current backlight level. Instructions on how to change this are written
F
earlier in this manual.