USER’ S MANUAL release 1.0
This manual must be considered an integral part of the projector.
1
BEFORE CONNECTING AND USING THE PROJECTOR, IT IS IMPORTANT TO READ CAREFULLY ALL THE
INSTRUCTIONS IN THIS MANUAL.
QUALIFIED PERSONNEL ONLY, IN COMPLIANCE WITH ALL THE SECURITY LAWS, CAN DO THE INSTALLATION, THE MAINTENANCE AND THE UTILISATION OF THIS PROJECTOR.
BEFORE CONNECTING THE PROJECTOR, MAKE SURE THAT THE FREQUENCY AND THE VOLTAGE VALUES ARE SUITABLE AS SPECIFIED ON THE PROJECTOR.
FOR ANY DOUBT, CONTACT YOUR SUPPLIER OR SEND AN E-MAIL TO:
tech@lamposrl.it
SOLID: Dust-tight
WATER: Protected against heavy seas
Suitable for direct mounting on normally flammable surfaces
Minimum distance from lighted objects (meters)
Rated maximum ambient temperature (indoor with ventilation)
Connection must be made to a power supply system fitted with efficient earthing (EN60598-1 – Class I fixture)
Replace any cracked protective shield, dichroic filter or lens
Index
Dimensions and weight ---------------------------------------------------------------------------------- page 2 Technical data --------------------------------------------------------------------------------------------- page 2 Admissible environmental conditions ----------------------------------------------------------------- page 2 Storage ------------------------------------------------------------------------------------------------------ page 2 Example of installation ---------------------------------------------------------------------------------- page 3 How many projector can I drive? --------------------------------------------------------------------- page 4 What is RGBW controller ------------------------------------------------------------------------------ page 4 Optycal system ------------------------------------------------------------------------------------------- page 5 Lamp replacement --------------------------------------------------------------------------------------- page 6 Spare parts ------------------------------------------------------------------------------------------------ page 7
2
Dimensions & weight
AS125 Slight TWO 4 lamps = 4,8 Kg AS126 Slight TWO 8 lamps = 4,9 Kg
Technical data
- Aluminium body with cooling fins, no fans
- Thermal-shock resistant glass
- Protection rate IP66
- Brackets for adjustable fixing
- Can be installed in any position
- Ideal for distances between 2 and 6m
- Halogen Lamp 50W 230V long life - GU10 socket – (example: Osram HALOPAR, Philips TWISTline)
- 4 lamps or 8 lamps version
- Colour changing system Red Green Blue White. (unlimited colours combination)
AS125 Slight TWO 4 lamps: it is without the electronics inside; it must be driven by a “RGBW Controller”
AS 126 Slight TWO 8 lamps: it is without the electronics inside; it must be driven by a “RGBW Controller”
Admissible environmental conditions
The projector was engineered and produced to function in outdoor areas with an air temperature ranging between 0° and 35°C and with a humidity level between 30 and 90%.
When choosing the installation, please make sure that the device is not exposed to extreme heat or in small area.
Storage
The projector, in its original packing, must be kept in covered, dry areas with a temperature between –10°C and +50°C. Attention, the projector will be damaged during the unpacking.
3
Example of installation
The power unit of RGBW CONTROLLER drives a series of Slight TWO, 6 wires cable.
In the example RGBW CONTROLLER drives a series of SLIGHT TWO on a STAND ALONE mode or on DMX (any stardard DMX consol can control one or more RGBW controller).
Slight TWO has 2 terminal connection blocks, one for the IN-PUT wires and one for the OUT-PUT wires (see the drawing)
COMMON = NEUTRAL common
= GROUND RED = RED Slight lamps GREEN = GREEN Slight lamps BLUE = BLUE Slight lamps WHITE = WHITE Slight lamp
4
How many projector can I drive?
Using a series of projectors with section 1.5mmq cables, RGBW CONTROLLER can drive up to a maximum of 8 Slight TWO 4 lamps.
Using a series of projectors with section 2.5mmq cables, RGBW CONTROLLER can drive up to a maximum of 16 Slight TWO 4 lamps.
Using a series of projectors with section 1.5mmq cables, RGBW CONTROLLER can drive up to a maximum of 4 Slight TWO 8 lamps.
Using a series of projectors with section 2.5mmq cables, RGBW CONTROLLER can drive up to a maximum of 8 Slight TWO 8 lamps.
The series of Slight TWO driven by RGBW controller execute the same colour simultaneously.
Do not use standard dimmers to drive Slight TWO.
Do not change the cable sequence.
What is the RGBW CONTROLLER?
RGBW CONTROLLER, it is a unit that can control a series of halogen projectors. To order this unit it is necessary specify if the projectors are with 3, 4 or 8 lamps, to have the correct software.
RGBW CONTROLLER is available with DIN45 fasting (for switch board), or inside an IP65 metal box (all indoor and outdoor application).
RGBW CONTROLLER can work on stand alone mode or on DMX (with dmx consol).
5
Optical system
Slight projectors have a very wide beam.
Slight 4 lamps has one lamp for each colour filter (Red-Green-Blue-White)
Slight 8 lamps has two lamps for Red, two lamps for Green, three lamps for Blue and one lamp for White.
The diffuser filter, increasing the beam angle and mixing the primary colours.
6
Lamp replacement
Disconnect the projector from the main power supply!
1) Unscrew the two screws, then open the projector.
2) Unscrew the two screws that hold the panel with the filters.
3) Remove the panel with the filters.
4) Wearing adequate protective gloves, rotate the bulb that should be replaced, of 90° CCW, then remove it.
5) Insert a new bulb in the socket and rotate it of 90° CW.
6) Insert the panel with the filters (see point 3).
7) Tight, strongly, the two screws that hold the panel with the filters (see
point 2).
8) Close the projector, and tight, strongly, the two screws (see point 1)
Use only 230V GU10 50W halogen lamps.
HALOGEN LAMPS CONTAIN SUBSTANCES THAT CAN POLLUTE THE AMBIENCE.
DISPOSE OF USING THE APPROPRIATE REFUGES (TOXIC).
7
Spare parts
When ordering spare parts for the projector remember to mention the model and serial number which can be found on the plate at the rear of the projector.
Call your area dealer or feel free to contact the manufacturer for any additional assistance.
SPARE PART LIST
CODE DESCRIPTION LP144 Halogen lamp, 230V 50W, GU10 socket
2618128 Slight bracket (specify the colour) 5108125 Temperate frontal glass, 187x187x5mm
The improper use of this projector, cancel the guarantee and our responsibility. All the information have been written and driven with
extreme care; however, we do not engage us any responsibility for contingent errors or omissions. We reserve the right to modify and/ or
improve our product as we retain necessary, without subsequent warning or notice. It is forbidden any complete or partial reproduction of
this handbook, if not expressly authorized.