Complete List of Standards ............................................................. Pages 93-94
analysis of water and soil.
INDEX
Acidity to Zinc .......................................................................................... Pages 95-98
Page 4
LaMotte Company manufactures its products at its 65,000 square foot facility in Chestertown, Maryland, near
Washington, DC on the east coast of the United States.
Capabilities
Over 10 years into our Lean Man-
ufacturing journey, LaMotte’s
chemists, engineers, and techni-
cians continue to optimize a wide
variety of processes to achieve
maximum quality and efficiency.
We offer a wide range of test
methods and tools for the ana-
lyst, from multi-factor test strips,
foil-packaged unit dose tablets,
unit dose powder vials, and liquid
reagents to sonic-welded color
comparators, multi-
parameter test
kits, and electron-
ic instruments.
LaMotte controls
the manufacturing
of all aspects to
ensure the high-
est quality.
4
We believe strongly in having a team of technical experts available by phone and email for customer support. The Research and Devel-
opment team works to constantly improve and create new test methods. Our in-house graphic design department provides extensive
services that are especially valuable for the many custom designed products that LaMotte welcomes.
All of these varied capabilities enable LaMotte to excel at helping people solve their analytical challenges.
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
Page 5
If your needs go beyond our standard
product line, then our Custom Test
Kit Services Department can design a
custom kit to meet your needs.
WE CAN design a kit that combines any
grouping of parameters you need.
WE CAN develop new test methods for new
proprietary compounds or for control of
specialized treatment programs
Custom | Int’l Sales
Custom Test Kit Services
WE CAN alter existing graphics and
packaging or design something new for
private labeling purposes
Available online at www.lamotte.com:
Entire Product Listing with Full Descriptions Printable Test Instructions Printable MSDSs Printable Reagents Certificates of Analysis
How The Custom Test Kit Service Works
1. Contact our Customer Service or International Sales departments by phone,
fax, or email. Tell us how you plan to use the product, the level of accuracy
and range you need, how many kits, and any limitations such as size, weight,
cost, or skill level of the end user (i.e. student, consumer, technician).
2. We will prepare a quote for you. Based on the information you provide, we will
suggest one of our non-catalog test kits or develop a kit to suit your needs.
3. Once you order, we immediately begin the development process, subject to
final approval before beginning production.
International Sales
Worldwide Distributor Network
For Pricing and To Order, contact a distributor near you.
To locate a LaMotte distributor, visit www.lamotte.com and
select “INTERNATIONAL”. For more information email us
at intl@lamotte.com.
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
5
Page 6
Colorimetric
See
Methods
Videos
Colorimetric
There are two basic types of colorimetric tests:
Test Methods
1. Tests which determine the concentration of a substance are based on Beer’s Law. Simply stated, this says that the higher the concentration of a
substance, the darker the color developed in the test, so more light is absorbed by the sample.
2. pH tests use an indicator which changes color with changes in the concentration of hydrogen ions, or the acidity of the solution.
Octa-Slide 2
Comparator
The Octa-Slide 2 replaces
the Octet and Octa-Slide
comparators. All 8 color
standards can be viewed
at once against a precision matched color bar
top-loaded next to the
sample tube. This com
parator system can be
used with existing re
agent system but is not
compatible with color
bars from the original
Octa-Slide.
-
-
IN OPERATION!
LRC Comparator
This innovative design replaces
the Axial Reader with a simpler
and significantly improved optical system. Simply place one
reacted sample in the front
and one un-reacted sample
behind it and let the light shine
down into both tubes. Precision
matched glass ampoules are in
the slide bar so even the most
sensitive low range colors can be
matched one-on-one with extraordinary ease and confidence.
6
Test Strips
Test strips are either dipped
or swirled in test solutions.
The resulting color reaction
is compared to a color chart
provided.
Color Chart Comparator
Color charts are laminated color
standards. The reacted sample
is held against the panel and
compared to the color standards.
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
Page 7
Electronic • Titrimetric
Electronic Methods
Electronic colorimeters measure the amount of light which travels through the reacted sample, and convert the measurement
to a reading as ppm, absorbance or %T. In addition to colorimeters, LaMotte offers instruments to test pH, TDS/conductivity,
dissolved oxygen, and turbidity.
Test Methods
Titrimetric
Titrimetric tests can be used to determine the concentration of a substance in a sample solution. After the sample is treated with an indicator, a standard titrant is added until a color change indicates a completed reaction. LaMotte offers four separate types of titration methods, allowing a choice of
precision and convenience.
Automatic Buret
Direct Reading Titrator
The Direct Reading Titrator is a 1.0 mL
microburet calibrated to allow direct
reading of the test result. Each Titrator
has a specific range, but may be refilled
to test higher concentrations.
Dropper Pipet
The drop count test uses a pipet to
provide fast, reliable measurements in
the field. The number of drops used to
obtain a color change is multiplied by a
given factor to produce the test result.
Dropper Bottle
The dropper bottle test uses bottle tips which deliver
a consistent standard drop size to add titrant to the
sample. As with the drop count test, the number of
drops used to complete the reaction is multiplied by a
given equivalence factor to determine the concentration. Many dropper bottle tests use different sample
sizes for different equivalences.
The self-zeroing automatic
buret is calibrated from 0 to
10 mL in 0.1 mL increments.
It is available with a squeeze
valve (pinchcock), glass stopcock, or Teflon® stopcock.
See page 85 for full line of automatic burets.
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
7
Page 8
SMART3 Colorimeter
Replaceable cup
protects optics
Instrumentation
6-button keypad
Over 80 Pre-Programmed Tests
New Bolder
Backlit Display
Simple
Code 1910
The user-friendly SMART3 Colorimeter is the ideal direct reading colorimeter for complete on-site water analyses.
All pre-programmed tests can be run on these compact instruments and
each test features automatic wavelength selection. The entire multi-LED
optical system is embedded in the light chamber and optimized for LaMotte
test reagent systems. The analyst can simply select the test and put in the
sample with reagent. The microprocessor, which selects the wavelength,
also allows the user to load up to 25 tests for analyzing custom reagent
systems. LaMotte stands behind every system we provide.
These portable colorimeters have the user in mind with these advanced
features:
IP67 Waterproof Simple, menu-driven operation Alphabetical test selection User-selected test sequences Self diagnostics with error/warning messages Instant readiness without “count down” delays; achieved by active
stabilization of lamp intensity
Auto-blank; Auto-off European CE mark
The user may select any of the wavelengths in each meter to
determine the absorbance or %T of a sample at the desired
wavelength.
Additional advancements include:
Superior narrow band-width interference filters New LCD display for improved readability USB interface Optional software for data storage and manipulation Lithium ion rechargeable battery, USB computer adapter is
included
As well as the incorporated features:
All wavelength filters - 428, 525, 568, 635 nm (SMART3 only) USB port and more...
* SMART 3 Turbidity is not the same as EPA 180.1 Turbidity
SMART Colorimeter® is a registered trademark of LaMotte Company.
8
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
Page 9
SMART3 Colorimeter & SMARTLink 3
See pages 17-18 for
complete reagent
system listing.
Instrumentation
Range:0-125%T
Resolution:1% FS
Accuracy:2% FS
CE Mark:Yes
Display:160x100 Backlight LCD, 20x4 line graphics display
Sample Cell:25 mm round cell, 10 mm square cuvette, 16 mm COD tubes
Datalogging:Up to 500 data points, USB transfer, time and date stamped
Keypad:6-button mechanical
Calibration:Factory set - user adjustable
Power:USB computer/power charger or Lithium Ion rechargeable battery,
3.7V, 2.5” x 0.75”, 1.7 oz.
Dimensions:19.05 x 8.84 x 6.35 cm; 7.5 x 3.5 x 2.5 inches
Weight:15 ounces
Bandwidth:10 mm typical
SMART3 • Code 1910
Comes with 6 sample tubes, power charger and manual
Chamber Cup
COD/UDV adapter Code 1724
6 sample tubes Code 0290-6
USB Cable Code 1720
USB Power Plug Code 1721
Car Charger Code 5-0132
Small Case Code 1910-GCS150
Large Case Code 1910-GCS440
SMARTLink 3 Program
Order Code 1901-CD
Interface the SMART3, 2020w and LTC-3000w meters with a Windows-based personal computer. The program
can be used to download data stored in the dataloggers of these meters. The program allows the user to identify, organize, view, manipulate and store data as a database on a PC. Data can also be copied and pasted or
exported to other applications as a CSV file.
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
9
Page 10
2020w Portable Turbidity Meters
1
1
Instrumentation
Industry-leading precision, sensitivity, and dependability in one of the most
innovative WATERPROOF, handheld meters available on the market!
EPA
80.
The multi-detector optical configuration assures long term stability and minimizes stray light and
color interferences. All readings are determined by the process of signal averaging over a 5 second
period. This minimizes fluctuations in readings attributed to large particles and results in rapid, highly
repeatable measurements. Ideally suited for both low-level drinking water applications as well as
monitoring high turbidity in the field.
Seven user selected languages – English, Spanish, French, Japanese, Chinese, Italian,
and Portuguese
Advanced calibration algorithms Best for low range turbidity analysis Easy menu driven operation and large LCD display
Waterproof to IP67
Lithium rechargeable batteries
500 point data log; stored results can be viewed directly on instrument or downloaded to a
computer via USB cable and SmartLink 3 software (available separately)
10
USB port
7 languages
Backlit display
EPA and ISO versions
2020we version meets US EPA design criteria as specified by EPA 180.1, Rev. 2.0 (1993) and
Standard Methods 2130 B-2001.
2020wi version meets design criteria for quantitative methods of turbidity using optical turbidimeters as specified by ISO 7027. Best for colored or extremely turbid samples.
Kits are supplied with 0, 1, and 10 NTU standard, sample bottle, four sample tubes, USB cable
and wall adapter.
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
Page 11
2020w Portable Turbidity Meter
Instrumentation
To Order:
2020we Kit • Portable turbidity meter complies with by EPA 180.1, Rev. 2.0 (1993) and
Standard Methods 2130 B-2001
Order Code 1970-EPA
2020wi Kit • Portable turbidity meter complies with ISO 7027 Standard
Order Code 1970-ISO
Accessories:
0 NTU/FNU Standard (EPA and ISO),
60 mL; Code 1480
1 NTU/FNU Standard (EPA and ISO),
60 mL; Code 1453
10 NTU/FNU Standard (EPA and ISO),
60 mL; Code 1454
100 NTU Standard (ISO), 60 mL;
Code 1455
1 NTU Standard (EPA), 60 mL;
Code 1450
10 NTU Standard (EPA), 60 mL;
Code 1451
100 NTU Standard (EPA), 60 mL;
Code 1452
Formazin Standard Solution,
4000 NTU, 60 mL; Code 6195-H
USB Cable, Code 1720 Wall Adapter, Code 1721 SMARTLink 3 Software; Code 1901-CD Six-pack of vials; Code 0290-6 Car Charger; Code 5-0132 Chamber Cup; Code 3-0038
Kits are supplied with 0, 1, and 10 NTU/FNU standards, sample bottle, six sample tubes, USB cable
and wall adapter—all in a sturdy carrying case.
Turbidity Specifications:
Unit of Measure
2020we
Units of Measure
2020wi
Range*0-4000 NTU/FNU, 0-10,500 ASBC, 0-150
Resolution*0.01 NTU/FNU 0.00-10.99
Accuracy*From 0-2.5 NTU the accuracy is ±0.05 NTU.
Detection
Limit
Range
Selection
Reproducibility*0.02 NTU/FNU or 1%
Light SourceTungsten (EPA), complies with EPA 180.1,
NTU, AU, ASBC, EBC
FNU, FAU, ASBC, EBC
EBC
0.1 NTU/FNU 11.0-109.9
1 NTU/FNU 110-4000
From 2.5-100 NTU the accuracy is ±2%.
Above 100 NTU the accuracy is ±3%.
0.05 NTU/FNU
Automatic
Rev. 2.0 (1993) and Standard Methods 2130
B-2001; 860nm LED (ISO), complies with ISO
7027
Meter Features:
Signal AveragingDisabled, 2, 5, 10
PowerUSB computer cable, wall adapter or Lithium ion
AC PowerOptional
Data Logging500 points
Auto Shut-OffDisabled, 5, 10, 30 seconds
Response Time<2 Seconds
Size7.5 x 3.5 x 2.5 inches; 19.05 x 8.84 x 6.35 cm
Weight13 ounces
Display6-line LCD with backlit display
*Over 600 NTU/FNU units expressed as AU/FAU
rechargeable battery, 3.7V, 2.5” x .75”, 1.7 oz
Portuguese, Chinese
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
11
Page 12
LTC-3000w Turbidity, Chlorine & Color Laboratory Meter
1
1
Instrumentation
EPA
80.
LTC-3000we (EPA version); Code 1972-EPA
LTC-3000wi (ISO version) Code 1972-ISO
Kits supplied with 0, 1 and 10 NTU standards, 6 sample tubes, DPD tablets, USB cable and AC adapter.
The LTC-3000we uses a tungsten lamp and meets the specifications of EPA 180.1.
Industry leading precision, sensitivity and dependability in one of the most innovative meters
available on the market for the measurement of Turbidity, Chlorine and Color.
The LTC3000w is a benchtop turbidity, chlorine and color meter with wide range and
high accuracy. ISO unit also available. The meter meets EPA 180.1, Rev. 2.0 (1993)
and Standard Methods 2130 B-2001 for turbidity and Standards Methods 4500-Cl G
for chlorine. The turbidity range is 0-4,000 NTU with a MDL of 0.05 NTU. The free and
total chlorine range is 0-10 ppm with a MDL of 0.03 ppm. The meter can store 500 data
points which can be downloaded to a computer, allows 7 different languages, and runs
on rechargeable batteries or a USB computer/wall adapter.
Ideally suited for both low-level drinking water applications as well as monitoring
Data logging up to 500 points with a date and time stamp – stored tests can be
viewed on the meter or downloaded to a PC
Compatibility with existing SmartLink 3 software Easy to read graphic LCD display Easy menu-driven operation
Meter Features
Signal AverageDisabled, 2, 5, 10
PowerUSB computer cable, wall
adapter or Lithium ion
rechargeable battery, 3.7V,
2.5” x 0.75”, 1.7 oz
Data Logging500 points
Auto Shut-OffDisabled, 5, 10, 30
LanguagesEnglish, French, Spanish,
Japanese, Italian, Portuguese,
Chinese
Response Time<2 Seconds
Dimensions8.75 W x 7.75 D x 3 H inches
22.2 W x 19.7 D x 7.6 H cm
12
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
Page 13
LTC-3000w, Turbidity, Chlorine & Color
Kits & Accessories
LTC-3000we US EPA Compliant, Order Code 1972-EPA, Turbidity (EPA 180.1, Rev. 2.0 (1993) and Standard Methods 2130 B-2001),
Chlorine (Standard Methods 4500-Cl G), Color (based on Standard Methods 2120 C)
LTC-3000wi ISO Compliant, Order Code 1972-ISO, Turbidity (ISO 7027), Chlorine (Standard Methods 4500-Cl G), Color (based on
Standard Methods 2120 C)
Instrumentation
0290-6Six pack of tubes
14800 NTU/FNU Standard (EPA and ISO), 60 mL
14501 NTU Standard (EPA), 60 mL
145110 NTU Standard (EPA), 60 mL
1452100 NTU Standard (EPA), 60 mL
14531 FNU Standard (ISO), 60 mL
145410 FNU Standard (ISO), 60 mL
1455100 FNU Standard (ISO), 60 mL
6903A-JChlorine DPD #1 Tablets, 100
Turbidity
Meets design criteria for quantitative methods of turbidity using
optical turbidimeters as specified by EPA 180.1, Rev. 2.0 (1993)
and Standard Methods 2130 B-2001
Two user selected factory calibration modes:
- Formazin
Polystyrene Japanese Turbidity Unit (Japanese Water Works
Regulation)
Supplied with formazin verified styrene divinylbenzene bead
suspensions (AMCO) for easy and accurate field calibration
User selected signal averaging (disabled, 2, 5 or 10
measurements)
Blanking with turbidity-free water allows a zero point calibration
for increased accuracy at very low turbidity levels
6197A-JChlorine DPD #3 Tablets, 100
1901-CDSMARTLink3 Software
6195-HFormazin standard solution, 4000 NTU, 60 mL
4140-02DPD Chlorine secondary standards kit
3176-02FAS-DPD Titration kit for chlorine titration
6973-HStandard chlorine solution, 250 ppm, 60 mL
6973-LStandard chlorine solution, 250 ppm, 475 mL
3858-HPermanganate solution, 1000 ppm, 60 mL
Unit of MeasureNTU, FNU, AU, FAU, ASBC, EBC
Range*0-4000, 0-10,500 ASBC, 0-150 EBC
Resolution*0.01 NTU/FNU 0.00-10.99; 0.1 NTU/FNU 11.0-109.9;
1 NTU/FNU 110-4000
Range SelectionAutomatic
Accuracy*From 0-2.5 NTU/FNU the accuracy is ±0.05 NTU/FNU.
From 2.5-100 NTU/FNU the accuracy is ±2%. Above
100 NTU/FNU the accuracy is ±3%.
Detection Limit0.05 NTU/FNU
Reproducibility*0.02 NTU/FNU, or 1%
Stray Light<0.02 NTU FNU
Light SourceTungsten (EPA), complies with EPA 180.1, Rev. 2.0
(1993) and Standard Methods 2130 B-2001, 860mm
LED (ISO), complies with ISO 7027
Signal AveragingDisabled, 2, 5, 10
*Over 600 NTU/FNU units expressed as AU/FAU
Chlorine
Exceeds design specifications for Standard Methods
4500-Cl G
Liquid and tablet DPD calibrations for Free and Total
Chlorine measurement
Wide-range accomplished with same cell and reagent
dosage
Low level detection. User selected units ppm or mg/L
Color
Uses Platinum-Cobalt method from Standard Methods 110.2 Wavelength 428 nm
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
Range0-10 ppm, Free and Total Chlorine
Resolution0.00-5.00 ppm Range: 0.01 ppm; 5.0-10.0 ppm Range:
Detection Limit0.03 ppm
Response Time<5 Seconds
Light Source525 nm LED, complies with Standard Methods 4500-Cl G
Range0-1000 cu
Detection Limit20 cu
Accuracy±15 cu
Light Source428 LED
13
Page 14
SMART® Spectro Spectrophotometer
A spectrophotometer that is easy to use
and more accurate than anything in its
Instrumentation
price range. With automatic wavelength
selection, pre-programmed tests, and
superior performance—this is the best
spectrophotometer for the money!
Menu Driven Display
Tests and functions are selected from scrolling menus for ultimate
simplicity. Results are displayed as %T, absorbance, and concentration.
Pre-Programmed Tests, User Tests &
Automatic Wavelength Selection
Over 80 pre-programmed tests. Up to 25 calibrations for additional
tests can be entered into the memory. The user can also customize
sequences for frequently run tests. The meter automatically moves
the grating to the required wavelength.
To Order:
Order Code 2000-01 (120V/60Hz and 220V/50Hz)
Includes 6 sample cells (25mm round), 2 sample cell holders (25mm
round and COD, 10mm cuvettes), power supply, battery charger, and
diagrammed manual.
Wavelength Range:350-1000 nm
Wavelength Accuracy:±2 nm
Wavelength Resolution:1 nm
Wavelength Bandwidth:5 nm (max)
Photometric Range:0-125%T, -0.1-2.5A
Photometric Accuracy:±0.005A
Photometric Noise:<0.001A at 0A; <0.002A at 2A
Photometric Drift:±0.002A/hr @500 nm
Photometric Stray Light:<0.5 %T
Dispersive Device:Grating - based system
Optical Mount:Modified Ebert
Grating:1200 grooves/mm ruled grating
Light Source:Quartz halogen
Bulb Life:1000 hours minimum
Sample Chambers:25 mm round cell, 10 mm
square cuvette UDV, COD
Detector:Silicon photodiode
Temperature Range:0-40°C
Modes:Conc., %T, ABS
Pre-Programmed Tests:Yes
Wavelength Selection:Automatic
User Tests:Yes, up to 25 can be entered and
edited
Datalogging:Yes, RS-232, datalogs 500 tests
Diagnostics:Yes
Power:110/220 volt or battery pack
(rechargeable)
Weight:4.65 kgs (10.3 lbs)
Size (WxDxH:)35 cm x 28 cm x 17 cm
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com14
Page 15
SMART® Spectro Spectrophotometer
Digestion Tubes for Total Nitrogen and Total Phosphorus
LaMotte offers low and high Total Phosphorus and a Total Nitrogen test that are reacted in a
heater block and are then tested using a colorimeter or spectrophotometer.
CodeDescriptionRange# of Tests
4024-01Low Total Phosphorus0-3.5 mg/L25
4025-01High Total Phosphorus0-100 mg/L25
4026-01Total Nitrogen0-25 mg/L25
Instrumentation
Multi-Range COD Reagent Systems
LaMotte-manufactured Chemical Oxygen Demand reagent systems used with our SMART3
Colorimeter or SMART Spectro Spectrophotometer are an easy and precise way to measure
critical COD levels. Measure low, medium or high levels of COD using your choice of mercury
(US EPA approved method) or non-mercury reagent systems. Each package contains 25
ready to use vials. All kits ship as R1.
This COD heater block features digital microprocessor control, programmable time and
temperature settings, and a dual LED display to monitor both temperature and timer. Perfect
for COD, Total Phosphorus, and Total Nitrogen testing PLUS other tests requiring digestion.
Temperature:30-200°C
Timer:0-999 minutes
Vial Capacity:12 (16 mm tubes)
Stability:±0.1°C@100°C
Weight:3.6 kg
Dimensions310 x 250 x 80mm (LxWxH)
CE Mark:Yes
Oven Temp Cutoff:212°C
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com15
Page 16
UV/VIS Spectrophotometer
Instrumentation
80+ Test Factors including:
ALUMINUM
AMMONIA
CADMIUM
CHROMIUM
COBALT
COD LR
COD HR
COPPER
CYANIDE
FLUORIDE
IRON
LEAD
MANGANESE LR
MANGANESE HR
NICKEL
NITRATE
NITRITE
PHENOL
PHOSPHATE
SULFATE
ZINC
The UV-Vis Spectrophotometer is an expandable, easy-to-use instrument that
provides maximum performance in a
compact, benchtop package. The instrument includes a high precision optical
bench, full programming capabilities,
customizable standard curves, and over
80 preprogrammed tests. Available options
include a variety of sample holders as well
as software-based wavelength scanning
and kinetics.
Order Code 7-2000-UV
Programmable wide range spectrophotometer can accept up
to 200 user curves in memory
Pre-programmed to analyze selected tests on a direct-reading
digital display
Advanced key pad with 22 buttons simplifies data entry Includes one 10 mm quartz glass cuvette, six round 25 mm
10 mL test vials, universal sample holder and square sample
holder
†As ppm except as otherwise indicated *Requires COD Adapter Code 5-0087 and Heater Block
**UV lamp 31041-1; UV lamp power source 31041-2; UV safety goggles 31041
Spectro /
UV-VIS Range†# TestsCodeShip
∞
NANH
Continue next page...
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
17
Page 18
Instrument Reagent Listing
Test FactorTest Method (# of reagents)SMART 3 Range†
† As ppm except as otherwise indicated * Requires COD Adapter Code 5-0087 and Heater Block
** UV lamp 31041-1; UV lamp power source 31041-2; UV safety goggles 31041
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
Page 19
Model 1200 • Single Test Colorimeter Labs
The 1200 Series of single test, direct reading colorimeters incorporates design advances that enhance reliability,
improve accuracy, and simplify the calibration process, all in a portable, hand-held package.
Simply insert the sample blank and press the
zero key.
HINGED LIGHT COVER
Flip-top lid over sample chamber prevents any
stray light, especially in the field, and avoids
misplacing separate light caps.
IMPROVED ACCURACY
The microprocessor enables the factory programmed calibrations to optimally match nonlinear curves.
EUROPEAN CE MARK
The 1200 has been independently tested and
has earned the European CE Mark of compliance for electromagnetic compatibility and
safety.
WATER RESISTANT DESIGN
Designed with excessive exposure to moisture
in mind, the 1200 colorimeters deliver troublefree performace in the field and lab.
EPA COMPLIANT
Employing the proper wavelength and the DPD
test method, the 1200 Chlorine Colorimeter Kit
meets or exceeds EPA design specifications
for NPDWR and NPDES chlorine monitoring
programs (EPA 330.5 and Standard Methods
4500-Cl G).
A GREAT VALUE!
Complete, economical package! The 1200
Chlorine Colorimeter Kit comes with enough
tablets for 100 tests or liquid reagents for
140 tests, six sample vials with screw caps,
instruction manual, and sturdy coloring case.
Instrument Type:Single wavelength,
direct-reading
colorimeter
Readout:3½ digit LCD
Photometric Accuracy: ±0.001 Absorbance Unit
* Instrument DPD featuring new ultra-clear fast dissolving tablets.
Code
Ship
Code
50
60 mL
(2 oz.)
100
Code
1000
Ship
Code
Ship
Code
# of
Tests
Ship
Codes
20
DPD Powder Pop® Dispenser
LaMotte now offers the Powder Pop Dispenser – a hand held, single-dose dispenser for 10 mL samples that delivers a
precise pre-measured dose of DPD reagent directly to your sample. Each Powder Pop kit includes enough reagent for
400 tests.
To Order:
Free Chlorine Powder Pop Dispenser (Order Code 3-0032)
Total Chlorine Powder Pop Dispenser (Order Code 3-0033)
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
Page 21
Model 1200 & 1200 UDV • Absorbance Colorimeters
Model 1200 & 1200 UDV • Absorbance Colorimeters
The versatile 1200 Series of single wavelength colorimeters now comes with the capability to display readings
directly in absorbance units. Six different wavelengths are available, with two sample vial options, to provide
maximum flexibility for your analytical procedures. Microprocessor control and advanced design assure accuracy,
easy operation, and durability.
Absorbance colorimeter kits are supplied with vials or cuvettes, water sample collecting bottle, 3 mL syringe
(1200-UDV only), all in a sturdy carrying case.
Instrumentation
Model 1200 Meter
For 25mm vials
Order Codes
Listed by wavelengths:
3627-420
3627-510
3627-530
3627-562
3627-570
3627-605
Model 1200-UDV
Meter
For 10mm cuvettes
Order Codes
Listed by wavelengths:
3627-420-UDV
3627-460-UDV
3627-510-UDV
3627-530-UDV
3627-562-UDV
3627-570-UDV
3627-605-UDV
Instrument Type:Single wavelength, absorbance
Measurement
Wavelengths:
Readable Resolution:0.01 Absorbance Unit
Photometric Precision: ±0.001 Absorbance Unit
Range:0-2.00 Absorbance Units
Display:3½ digit LCD
Response Time:2 seconds
Detector:Silicon Photodiode
Sample Chamber:Meters are available with one
Light Source:LED
Interface:RS-232 serial interface, 8 pin
Power:Battery Operation: Alkaline
colorimeter
420nm, 460nm, 510nm,
530nm, 562nm, 570nm, or
605nm
of two chambers to accept
25mm flat-bottomed glass
vials (1200) or 10 mm square
polystyrene cuvettes (1200UDV)
mDIN, 9600b, 8 data bits, 1
stop bit, no parity
9-volt DC battery; Line
Operation:
230V/50Hz with adapter
120V/60Hz,
Chlorine Standards for Model 1200 & SMART3
For use with the 1200 series and SMART3 chlorine colorimeters. Secondary standards provide a fast
way to check calibration without the burden of making primary standards. Based on Standard Methods
for the Examination of Water and Wastewater, the operator can calibrate a colorimeter using a permanganate primary standard or a chlorine primary standard. Once the meter is calibrated using the
primary standard, the operator can insert secondary standards periodically to evaluate the calibration
of the instrument.
Secondary standard kit contains a blank and 3 standards for low, mid-range, and high chlorine
calibrations.
Packaged in a small plastic case with Certificate of Analysis stating range of each standard.
To Order:
DPD Chlorine Secondary Standards, Order Code 4140-02
FAS-DPD Titration Kit for Chlorine Titration, Order Code 3176-02
Standard Chlorine Solution, 250 ppm, Order Code 6973-H (60 mL), Order Code 6973-L (475 mL)
Permanganate Solution, 1000 ppm, Order Code 3858-H (60 mL)
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
21
Page 22
TRACER PockeTesters
The world’s first pocket-sized ISE meter for measuring total chlorine.
Use it to test pH and ORP with interchangeable flat surface sensors.
Total Chlorine TRACER
Instrumentation
Order Code 1740
Read Total Chlorine from 0.00-10 ppm
Readings are not affected by sample color or turbidity Automatic self calibration; extra bold display includes an analog bar graph feature; memory can store
up to 15 readings
Chlorine and pH modes also display sample temperature Unit identifies which probe is in use and retains calibrations Automatic shut-off and Low Battery indicator; uses four 3V CR-2032 batteries
Includes 100 reagent tablets at almost half the price of
similar Chlorine ISE reagents
Follows EPA protocol for ISE methods
TRACER KIT with pH, Total Chlorine and ORP probes
Order Code 1740-KIT-01
Includes Tracer meter with pH, Total Chlorine and ORP probes,
100 Chlorine tablets, 50 pH 7.0 buffer tablets, tablet crusher and
convenient carrying case.
1740-KIT-01
pH TRACER
Order Code 1741
Provided with 4, 7, and 10 pH buffer tablets.
Rugged flat surface electrode will alert user when it’s time to “RENEW” A “CAL” indicator shows when to recalibrate and user can select a 1, 2, or 3 point calibration Includes Automatic Temperature Compensation and displays temperature while showing pH result
Range:0.00 to 14.00 pH
Temp:32° to 149°F (0° to 65°C)
Resolution:0.01 pH
Accuracy:±0.01 pH
TRACER with pH and Total Chlorine probes
Order Code 1741-KIT-01
Includes Tracer with pH and Total Chlorine probe, 100 Chlorine tablets, 50 pH tablets, tablet crusher in
a convenient carrying case.
ORP TRACER
Order Code 1742
High resolution to 1 mV Automatic self calibration
Range:-999 to 999 mV
Resolution:1 mV
Accuracy:±4 mV
TRACER KIT
with pH and ORP probes
Order Code 1742-KIT-01
Includes Tracer with pH and ORP
probe, 100 Chlorine tablets, 50 pH
tablets, tablet crusher in a convenient carrying case.
OPTIONS
Additional Probes
Order Code 1733 pH Sensor (0-14.00/±0.01 pH)
Order Code 1734 ORP Sensor (±999mV/±4mV)
Order Code 1732 Cl2 Sensor (0-10.00/±10% of reading)
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com22
Chlorine Test Tablets
Order Code 7044A-J
Specially formulated just for the TRACER, these
deliver a precise amount of iodide for a 20 mL
sample. Available in packages of 100.
Page 23
TRACER PockeTesters
Instrumentation
EC/TDS/SALT TRACER
Code 1749
Easy to use 2% accuracy for EC, TDS, and Salt modules Automatic temperature compensation Self calibration Memory can store up to 25 readings; auto-
power off after 10 minutes of no button
presses
Automatic shut-off and low battery indicator;
uses four 3V CR-2032 button batteries
Options:
EC/TDS/SAL Replacement Electrode*,
Order Code 1765
Sample Cup w/cap, Order Code 1745-1
Conductivity Standard, 84 µS,
Order Code 6312-G
Conductivity Standard, 1413 µS,
Order Code 6354-J
Conductivity Standard, 12,880 µS,
Order Code 6317-G
Conductivity: 0 to 199.9 µS, 200 to 1999 µS,
2.00 to 19.99 mS
TDS:0 to 9,999 ppm
Salinity:0 to 9,999 ppmTemperature32°F to 149°F (0 to 65°C)Accuracy:EC, TDS, Salt: ± 2% FS;
Temperature: ± 1°C (1.8°F)
*Not interchangeable with Cl/pH/ORP TRACER
Fluoride TRACER
Order Code 1756
The first Fluoride meter with built-in
Automatic Temperature Compensation
and fastest response (<1 min)
Small sample/TISAB volume required for testing Complies with EPA Method 340.2
(Potentiometric Ion Selective Electrode)
Automatic electronic 1 or 2 point calibration
with offset adjustment
Memory stores 25 labeled readings and
water resistant to IP54
Complete with electrode, 20 TISAB reagent tablets,
sensor cap, four 3V button batteries, and 48” (1.2m)
neckstrap
Fluoride TRACER KIT
Order Code 1756-KIT-01
Includes Tracer meter with 4 oz. bottle of 1 ppm
Fluoride Standard and convenient carrying case.
Options:
TISAB Reagent, 100 Tablets, Order Code 7024-J
Replacement Electrode, Order Code 1757
Fluoride Standard, 1 ppm, 1000 mL, Order Code 2798-M
Fluoride Standard, 1,000 ppm, 60 mL, Order Code 4154-H
Fluoride Standard, 1,000 ppm, 500 mL, Order Code 4154-L
Fluoride:0.1 to 10 ppm, max. resolution: 0.1 ppm, accuracy:
±3% rdg
Temperature32°F to 140°F (0 to 60°C), max. resolution: 0.1 °F,
Measures five parameters including Conductivity, TDS,
Salinity, pH, and Temperature using one electrode
Units of measure: pH, µS, mS, ppm, ppt, mg/L, g/L, °C, °F
Memory stores up to 25 labeled readings; auto power off and
low battery indicator
Adjustable Conductivity to TDS ratio
RangeResolutionAccuracy
Conductivity0 to 199.9 µS, 200 to 1999 µS, 2.00 to 19.99 mS0.1 µS±1%TDS/Salinity0 to 99.9 ppm (mg/L), 100 to 999 ppm (mg/L), 1.00 to 9.99 ppt 0.1 ppm (mg/L) ±2%pH0.00 to 14.00 pH0.01 pH±0.01 pHTemperature32° to 149°F (0 to 65°C)0.1°F/°C±1.8°F/°C
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
See pages 32
for pH Tablets
Options:
pH/EC/TDS/SAL Replacement Electrode*, Order Code 1755
Sample Cups w/cap, Order Code 1745-1
Conductivity Standard, 84 µS, Order Code 6312-G
Conductivity Standard, 1413 µS, Order Code 6354-G
Conductivity Standard, 12,880 µS, Order Code 6317-G
23
Page 24
Dissolved Oxygen Meters
Dissolved Oxygen Tracer
Order Code 1761
Instrumentation
Oxygen level displayed as % Saturation from 0 to 200.0% or Concentration from 0 to 20.00 ppm (mg/L) Adjustable Altitude Compensation (0-20,000 ft in 1,000 ft increments) Adjustable Salinity Compensation from 0 to 50 ppt Memory stores up to 25 data sets with DO and Temperature reading Self-calibration on power up; Data, Hold, Auto power off, Low battery indicator Waterproof to IP67 Optional 3 ft (1m) or 16 ft (5m) extension cable; complete with DO electrode, protective sensor cap, spare membrane
cap, electrolyte, four 1.5V CR-2032 batteries, and 48” (1.2m) neckstrap
RangeResolutionAccuracy
DO (sat. mode)0 to 200.0%0.1%±2% FS
DO (conc. mode) 0 to 20.00 ppm (mg/L)0.01 ppm (mg/L)0.4 ppm (mg/L)
Temp.32 to 122°F (0 to 50°C)0.1°F/°C±1.8°F (1°C)
Dimensions1.4x6.9x1.6” (36x176x41mm)
Weight3.8 oz (110g)
Dissolved Oxygen Meter
Order Code 5-0107-01
No meter warm-up required Low-maintenance probe Key in salinity and pressure values manually Independent 100% and zero adjustment calibrations Offset adjustment capabilities Displays electrode diagnostics Easily toggle from
mg/L (ppm) or
% saturation to
temperature
mode
Accessories
DO Membrane Kit, 6 screw-on
membranes and solution
(Order Code 1761M)
DO Sensor Module
(Order Code 1762)
3 ft. Cable (Order Code 1763) 16 ft. Cable (Order Code 1764)
RangeResolutionAccuracy
mg/L (ppm)0.00 to 20.00 mg/L
% Saturation0.0 to 200.0%0.1%±1.5% FS
Temp.-5.0 to 105.0°C 0.1°C±0.5°F
Salinity correction0.0 to 50.0 ppt0.1 pptMethod: Key
Barometric pressure
correction
Temperature
compensation
Operating temperature0 to 50°C
ProbeGalvanic, 3 ft. probe cable
PowerFour 1.5 V AAA batteries (included), >700 hrs
Dimensions5.5”L x 2.7”W x 1.3”H
Weight1.0 lb (0.45 kg)
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
Page 25
PockeTesters
PAGE
pH PockeTester 10
Order Code 5-0103
±0.1 pH accuracy
pH PockeTester 20
Order Code 5-0104
±0.01 pH accuracy
Both meters feature automatic temperature compensation, and buffer recognition for
three point calibration based on US (pH 4.01, 7.00, 10.01) or NIST (pH 4.01, 6.86, 9.18)
systems. The sensor is a double junction Ag/AgCl system with polymer gel. The IP67 rated
housing features a 1.0625” (26.99 mm) display, which also displays diagnostic messages.
Auto-off after 8.5 minutes to conserve battery life.
(Replacement Electrode, Code 5-0097)
(Replacement Electrode, Code 5-0097)
Instrumentation
Double Junction ORP PockeTester
Order Code 5-0079
–999 mV to +1000 mV Large surface area platinum band sensor 1 mV resolution, 2 mV accuracy HOLD function, Auto-off
for complete PockeTester specs
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com25
Page 26
PockeTesters
Instrumentation
Code 5-0080
Microprocessor-Based TDS
Dual Range PockeTester
Order Code 5-0080
0-2000 ppm (10 ppm resolution) ; 0-10.00
ppt (0.10 ppt resolution)
±1% full-scale accuracy Automatic temperature compensation (ATC) Replacement electrode Push-button calibration Auto shut-off Full reading displayed – no need to multiply
Replacement Probe (Order Code 5-0084)
Code 5-0078Code 5-0082
Salt PockeTester
Order Code 5-0078-01
0–10 ppt ( 0.10 ppt resolution) Carrying Case and calibration standard
included
Replacement Probe
(Order Code 5-0084)
Microprocessor-Based EC
Conductivity Dual Range
PockeTester
Order Code 5-0082
0-2000 µS (10 µS resolution); 0-20.00 mS
(0.10 mS resolution)
±1% full-scale accuracy Automatic temperature compensation (ATC) Replacement electrode Push-button calibration Auto shut-off Full reading displayed – no need to multiply
Replacement Probe (Order Code 5-0084)
26
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
Page 27
PockeTester Specifications
Specifications for pH PockeTestersSpecifications for Specialty PockeTesters
ModelpH PockeTester 10pH PockeTester 20Min-Max ThermometerORP PockeTesterSalt
Code5-01035-01045-00955-00795-0078-01
Range–1.0 to 15.0 pH; extended range–10 to 200°F,
Resolution0.1 pH0.01 pH0.1°F to 199.9°,
Accuracy±0.1 pH±0.01 pH±1.8°F / ±1.0°C±2 mV±10%
CalibrationSelect up to 3 points
Operating
Temperature
Temperature
Compensation
Special
Functions
Power &
Battery Life
(4.0, 7.0, 10.0 or 4.01, 6.86, 9.18)
32 to 122°F;
0 to 50°C
Automatic (ATC)
0 to 50°C
On/Off or Auto-Off after 8.5 min.; HOLD;
CALibrate; CONfirm
Four 1.5V alkaline button cell batteries
(supplied), 500 hour use
32 to 122°F;
0 to 50°C
14 to 392°C
1°C above 200°
Factory calibrated; fine
adjustment through
keypad
32 to 122°F;
0 to 50°C
——Automatic(ATC)
On/Off or Auto-Off after
8.5 min.; HOLD; °F or °C
scale selectable; factory
calibration maintained
when batteries are
replaced
LR-44 button cell. 2 yr lifeFour 1.5V alkaline
–999 mV to +1000 mV0-10.00 ppt salinity
1 mV0.10 ppt salinity
full-scale
Offset calibration to
ORP standard or work
standard
32 to 122°F;
0 to 50°C
On/Off or Auto-Off after
8.5 min.; CALibrate;
CONfirm; HOLD (HO) and
HOLD/ CANCEL (HC)
batteries (supplied) 500
hrs. use
One-point with
trimpot
32 to 122°F;
0 to 50°C
0 to 50°C
Four 1.5V alkaline
batteries (supplied)
150 hrs. use
Instrumentation
Dimensions &
Weight
ModelTDS Dual RangeEC Dual Range
Code5-00805-0082
Replacement Electrode5-00845-0084
Range0-2000 ppm/ 0-10 ppt0-2000 µS; 0 to 20 mS
Resolution10 ppm/0.10 ppt10 µS; 0.10 mS
Accuracy±1%FS
CalibrationOne-point, push-button calibration using buttons inside battery compartment
Operating Temp.32 to 122°F; 0 to 50°C
Temperature Comp.Automatic (ATC) 0 to 50°C
Special FunctionsFull reading displayed
Power & Battery LifeFour 1.5V alkaline batteries (supplied); 150 hours
Dimensions & Weight8.5” (216 mm) L x 2.4” (61 mm) W x 2.5” (64 mm) H (boxed);
8.5” (216 mm) L x 2.4” (61 mm) W x 2.5” (64 mm) H (boxed); 6.5” (165 mm) L x 1.5” (38 mm) Dia. (unit only);
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
27
Page 28
Temperature Measurement
Instrumentation
IR Meter with Color Alert System
Code 5-0133
Convenient non-contact temperature measurements, now with a laser
sighting, plus color and sound alerts!
Features
Fast and accurate measurements at 12” where the two lasers
converge with 12:1 field of view
Measures up to 950°F (510°C) Blue backlit dual LCD display changes to Red backlit outside set
points
Instantaneous response captures spikes in temperature Max mode captures and holds rapidly changing temperatures Lock function for continuous readings Adjustable emissivity increases measurement accuracy for
different surfaces
Double molded housing Complete with case and 9V battery Adjustable High/Low set points with color and audible alarms
signal out of range temperature
Blue backlight:
within temperature
range
Red backlight
plus audible
alert: exceeds
temperature
“Min-Max” Memory Thermometer
Order Code 5-0095
Range: 14 – 392°F or -10 – 200°C °F or °C selectable scale Recalls minimum and maximum temperature
Range:-4 to 950°F (-20 to 510°C)
Resolution:1°C/1°F
Accuracy:25 to 260°C (77 to 500°F): ±(1% of rdg
+2°F/1°C)
Repeatability:±0.5% or 1.8°F/1°C
Response Time:150mSec
Emissivity:0.10 to 1.00 adjustable
Distance-to-Spot Size:12:1Power:One 9V alkaline batteryDimensions:5.7 x 4 x 1.6 inches (146 x 104 x 43 mm)Weight:5.74 oz. (163g)
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com28
Page 29
LaMotte pH, CON, TDS Meters
Instrumentation
Economical Field Meters
Push button operation Up to five point calibration Temperature readout Automatic Temperature Compensation Auto-off after 17 minutes; Hold function Buffer recognition (pH 5 meter) Adjustable conductivity to TDS factor (TDS 6 meter)
Microprocessors have enabled meter manufacturers to combine many features into
smaller designs with better accuracy. The 5 and 6 Series meters are good examples
(see specifications below). All meters include electrodes and temperature probes,
and are available with or without a carrying case.
The pH 5 without case includes pH 4, 7 and 10 buffer tablets. The pH 5 with case includes pH 4, 7 and 10 buffer liquids. The TDS 6 and Con 6 with carrying cases include two calibration standards. All meters have two-year warranties.
Model
Order Codew/out case 5-0034-01
Replacement
Probe
Range:0.00 to 14.00 pH0.0 to 100.0°C0.0 to 20.00,
Resolution:0.01 pH0.1°C0.01, 0.1, 1 µS
Accuracy:±0.01 pH±0.5°C±1% full scale or ±1 digit±1% full scale±0.5°C
Calibration:Up to 5 Buffer Values Offset 0.1°C
Automatic Temperature Compensation (ATC)Automatic Temperature Compensation (ATC)
pH 5
(pH)
pH Probe
Order Code 1904
hours continuous use
32 to 122°F; 0 to 50°C32 to 122°F; 0 to 50°C
Temperature Probe
Order Code 5-0041
pH 5
(Temperature)
w/out case 5-0038-02
with case 5-0039-02
0 to 20.00, 200.0 mS
up to 5 points (1 per range) for multi-point calibration;
increments
CON 6 Meter
(Conductivity)
w/out case 5-0036-02
with case 5-0037-02
CON/TDS Probe
Order Code 5-0106
200, 2,000.0 µS
0.01, 0.1 mS
or 1 point for single point for entire range
0.0 to 10.00, 100.0, 1000 ppm,
1.0 to 10.00, 100.0, 200 ppt
0.01, 0.1, 1.0 ppm
fixed 2% per °C factor, adjustable 73%
Four AA alkaline batteries (supplied)
>100 hours continuous use
TDS 6 Meter
(TDS)
0.01, 0.1 ppt
CON 6 & TDS 6
Meters
(Temperature)
-10.0 to 110.0°C
0.1°C
Offset 0.1°C
increments
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
29
Page 30
pHPLUS Direct Digital pH/ISE Meter
Instrumentation
pHPLUS DIRECT Meter
Laboratory precision in a water-resistant design!
Read pH, mV/R.mV, temperature, and concentration
with accuracy – ISEs read concentration in ppm. Easyto-use in any test mode. Includes pH probe, temperature
probe, buffers and rubber boot with stand.
Specifications
pH
Range:0.00 to 14.00
Resolution:0.01
Accuracy:0.01
Calibration:Up to 5 points
Electrode:Epoxy, Ag/AgCl
Temperature
Range:0 to 100°C
Resolution:0.1°C
Accuracy:±0.1°C
Concentration
Range:0.00 to 100
Resolution:± LSD
Accuracy:±0.5% or ±1 LSD
mV/R.mV
Power:4 AAA batteries
Size (LxWxH):2.75W x 5.75H x 1.375D in.
Optional ISE Electrodes*
Although the pHPLUS Direct reads directly in ppm, an initial calibration is
required. The standard solution, replacement electrolyte, ionic strength adjustor and pipet are included in the Accessory Kit. The ammonia accesory kit
also contains replacement membranes.
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com30
Accessory Kits
CodeDescription
5-0098Ammonia
5-0099Fluoride
5-0100Nitrate
*Accessory Kit required to
calibrate the ISE.
Page 31
DPD TesTabs® Instrument Grade
LaMotte has developed a rapid dissolve instrument grade
DPD tablet system. Instrumental analyses require a clear,
particle-free testing solution. In the past, it was necessary
to use a crusher to dissolve the instrument grade tablets.
Now, free and total chlorine samples can be done with
instrument grade tablets that dissolve without crushing.
DPD Reagents
Quantity/Order Code
Tablet
Chlorine DPD #1
Instrument*
Chlorine DPD #3
Instrument*
Chlorine DPD #4
Instrument*
* Instrument DPD featuring ultra-clear fast dissolving tablets.
See page 71 for Visual Tablets
50
6903A-H6903A-J6903A-MNH
6197A-H6197A-J6197A-MNH
6906A-H6906A-J6906A-MNH
100
1000
Instrumentation
Ship
Code
DPD Liquid Reagents
The liquid alternative to DPD tablets can be used with existing LaMotte chlorine comparators or
colorimeters. DPD 1A and DPD 1B are added to a 5 or 10 mL sample to test Free Available Chlorine.
DPD 3 is added to the reacted sample to measure Total Chlorine. Liquid reagents are also available
to measure pH, Hardness, Alkalinity, and Copper.
30 mL (1 oz.)CodeShip Code
DPD 1AP-6740-GNH
DPD 1BP-6741-GR2
DPD 3P-6743-GNH
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com31
60 mL (2 oz.)CodeShip Code
DPD 1AP-6740-HNH
DPD 1BP-6741-HR2
DPD 3P-6743-HNH
Page 32
pH Buffers/Electrode Soaker
Instrumentation
Standardized
pH Buffer Solutions
For use in calibration of pH meters. Ordering information for all buffers is
listed below.
pH
Value Code
4.012866-J
2866-L
6.862808-L500 mL
Note: Other pH values available
Size
120 mL
500 mL
pH
Value Code
7.002881-J
2881-L
9.182809-L120 mL
10.002896-J
2896-L
Size
120 mL
500 mL
120 mL
500 mL
Buffer Tablets
Add one tablet to 20 mL of Deionized Water to produce buffers.
Available in 50 and 100 tablet packs. In foil strips of 10 tablets each.
pH Value Code
4.03983A-J-100
4.03983A-H-50
7.03984A-J-100
7.03984A-H-50
10.03985A-J-100
10.03985A-H-50
Color-Coded
pH Buffer Solutions
Minute amount of color permits immediate visual distinction of
different buffer values.
pH ValueCodeColorSize
4.013771-LRed500 mL
7.003772-LYellow500 mL
10.03773-LBlue500 mL
Electrode Soaker Bottle
Order Code 0668
Continuously soaks pH electrode in a storage solution
to prevent probe dry out.
Twist top “O” ring seal prevents leaks.
32
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
Page 33
Conductivity/TDS Solutions
The following potassium chloride solutions can be used to standardize
conductivity meters. TDS values are based on a 0.7 conversion from
conductivity.
Instrumentation
Conductivity Solutions
CodeDescription Size
6416-L74 µS/cm, 52 ppm500 mL
6312-L84 µS/cm, 59 ppm500 mL
6417-L718 µS/cm, 503 ppm500 mL
6354-L1,413 µS/cm,989 ppm500 mL
6418-L6,668 µS/cm, 4668 ppm500 mL
6317-L12,880 µS/cm, 9016 ppm500 mL
6419-L58,640 µS/cm, 41,048 ppm500 mL
Conductivity Neutralizing Solutions
Used to neutralize hydroxl ion in boiler water, thus enabling accurate determinaion of ionic conductivity.
CodeDescription
6483-H (60 mL)
6483-L (500 mL)
6483-N (3800 mL)
6479-JGallic Acid
3705-LAcid IndicatorContains acetic acid and phenolphthalein.
Conductivity
Neutralizing
Solution
Powder
Contains citric acid and phenolphthalein.
Add liquid until sample changes color.
Available in 60 mL, pint, and gallon sizes.
Organic acid powder; indicator must be
purchased and added separately. Add raw
powder to sample containing indicator
until color changes. Available in 100 g.
Add liquid until sample changes color.
Available in 500 mL (pint).
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
33
Page 34
Convenient and Economical
Strips
®
LaMotte offers a convenient, economical way to perform spot checks for several water quality factors. LaMotte
test strips are a great way to monitor water without having to use reagents or field kits. Strips are available
for the factors below…and we’re working on more!
*Strips shown have been evaluated for use in these applications. Use in other applications is subject to potential interferences.
Contact LaMotte Technical Services for more information.
Sanitizer Test Papers & Strips
Chemically treated paper strips change to indicate sanitizer level. Strips and color chart are
packaged in a waterproof plastic vial. 2951 is specifically formulated to read all types of QAC.
High Range QAC2951HR200, 400, 600, 1000, 1500 ppm (50 strips)
For PERACETIC ACID Test Strips, see page 34.
30310, 50, 100, 250, 500, 800 ppm (50 strips)
2934Low Range: 0, 10, 20, 40, 80
High Range: 0, 100, 200, 400, 800 (50 strips)
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
35
Page 36
Micro Testing Simplified!
Microbiological
BioPaddles®
Ready to use. Saves time! Longer shelf-life than traditional Petri dishes No refrigeration required
BioPaddles® are flexible dual-agar paddles each containing microbe-specific media enclosed in a
sterile vial. Identify and quantify microbes in air, soil, water, or any surface!
Liquid Sampling: Remove the paddle from the vial and fill the vial (approximately 40ml) with the
sample. Insert the paddle, swirl for 15 seconds. Pour out the liquid, replace the paddle in the vial,
and incubate.
Surface Sampling: Remove the paddle from the vial and gently touch each paddle media surface
to the sample surface. Replace paddle in the vial and incubate.
Air Sampling: Remove the paddle from the vial. Invert and mount the circular cap into the vial, exposing the agar covered paddle. Expose for 15 minutes. Replace the paddle in the vial and incubate.
36
All BioPaddles® products come with a free app! LaMotte BioPaddles Colony ID™ App lets users
compare colony examples on BioPaddle agar types from 5 microhabitats (air, water, soil, surface
and food). Also contains information regarding organisms, microbiological techniques, and more!
For fresh, brackish, and salt water use.
BioPaddles® Products—all packaged 10 paddles per box. Includes general instructions and provides
access to detailed Technical Documents for each paddle type.
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1, r1) Small Qty. Hazardous Material - No Fees • (Lq, LQ, R2, r2, R3, r3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
https://itunes.apple.com/
us/app/id567584998
Page 37
Bacteria & Coliform Testing Kit
Type Of Agar(s)DescriptionCode
Nutrient For routine culture of non-fastidious bacteria.5550
Sabouraud
Dextrose
Tryptic Soy (TSA)/
Rose Bengal (RB)
Nutrient TTC/
MacConkey
For selective cultivation of fungi (yeasts and molds)5551
For cultivation of a wide variety of microorganisms (TSA) and selective isolation of yeasts and molds (RB).5552
TTC. For field sampling cultivation and enumeration of coliform bacteria total coliform count (TCC). Gram (-) bacterial
colonies appear as red dots. Gram (+) bacteria are usually inhibited.
MAC. Medium gives improved differentiation between coliforms and non-lactose fermenting organisms. Gram (+)
cocci are usually inhibited.
5553
Microbiological
Coliform Screening Test
The 4-3616 is an easy-to-use, disposable 5-tube
method to indicate the presence of Total Coliform
Bacteria in a water supply. The water sample is placed
in test vials containing the special coliform indicating
tablets and stored at room temperature for a predetermined time period. After the required storage period,
the vials are examined to determine the presence of
coliform bacteria.
Code Test System
4-3616 Tableted nutrient
based on 5 tube MPN
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
Range/Sensitivity# of Tests
(# of Reagents)
Presence/Absence1 (1)NH (1)
Shipping Code
(Wgt./lbs)
37
Page 38
Biological Activity Reaction Test
15
A simple yet effective method for monitoring the population size and/or activity
of specific groups of bacteria.
Microbiological
BART Biodetector
With BART, you can monitor for Iron Related Bacteria (IRB), Sulfate Reducing Bacteria (SRB) and
Heterotrophic Aerobic Bacteria (HAB) – the three
most important agents involved in biofouling. Other
BART systems are described below. These bacteria
can cause corrosion, clogging, fouling of the water,
and increased hygiene risks, so it is important to
have an easy and accurate method of determining
their presence and level of activity.
The screw-cap should
be tightened on the
BART tube so that
casual leakage, such
as from tipping the
tube over, can be
prevented.
Aerobic growth of
bacteria will occur at
the surface of the
sample between the
BART-BALL and the wall
of the BART tube.
mL of water sample is
used to bring the BART-
BALL up to the correct
level. Nutrients will
gradually diffuse up the
water column to support
this bacteria growth.
Once the oxygen has
been used by the
aerobes, this zone
becomes free of oxygen
and anaerobic growth
will dominate.
Easy to Use
The BART Biodetector requires no microscope, no laboratory, and
no incubator! The test is done at room temperature in your office
or treatment room, on a desk, shelf, or in a cupboard, and is viewed
daily. Different microorganisms like to grow at different heights
in a column of water to which nutrients have been added. BART
biodetectors contain nutrients in the base of a column and a ball.
The ball restricts the amount of oxygen entering the water column,
so that aerobic organisms grow around the ball and anaerobic
organisms grow deep down in the water column. By changing
the nutrients in the base of the column, different organisms are
encouraged to grow. BART determines presence and activity levels.
Easy to Analyze
The time taken for a color change (reaction) to occur gives a measure of the population size and activity. A color change occurs in the BART tube as a result of the oxygen gradient diffusing from the bottom upward. The change of color indicates a
presence of bacteria within that sample. Interpretation is provided with the kit.
The Test
Full instructions for the use of BART biodetectors are included with your purchase. Each
individual test consists of:
Test vial with media and BART ball Outer tube for spill containment, odor control, disinfection, and disposal
To Order
Each kit number below includes nine (9) BARTs. Each BART test is color-coded for quick and
easy recognition.
BART ColorTestOrder
RedIron Related Bacteria - IRB-BART5-0024
BlackSulfate Reducing Bacteria - SRB-BART5-0025
Lime greenSlime Forming Bacteria - SLYM-BART*5-0026
ComboThree each of IRB-, SRB-, and SLYM-BART5-0032
BlueHeterotrophic Aerobic Bacteria - HAB-BART5-0027
38
Nutrient medium for
growth is provided as a
sterile dried pellet on the
floor of the tube.
*The SLYM-BART requires the use of a fluorescent lamp (Order Code 5-0033)
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
Page 39
In cleaning applications,
P alkalinity is sometimes
referred to as active
alkalinity. The difference
between the P reading
and the T reading is
“inactive” alkalinity.
Individual Test Kits
Acidity - Aluminum
Code 3569-01
Order Code
ACIDITY A standard base titrates acidity to the phenolphthalein endpoint. The 7182 uses different sample sizes and a 1:10 dilution to test
hydrochloric, sulfuric and phosphoric acids with either a 1 drop = 0.1% or 1 drop = 1.0 % equivalence.
7182-01HCl, H2SO4, H3PO4
ALKALINITY Kits use titrations with standard acid to the phenolphthalein (P) and/or total (T) alkalinity endpoint. The mixed indicator, BCG-MR,
is used for total alkalinity determinations. Where hydroxyl(OH) alkalinity is determined directly, as with kit #7515, the sample is pre-treated with
barium to precipitate carbonate alkalinity. All results are expressed as CaCO3. To convert results to Na2O, multiply the answer by 0.62.
4491-DR-01Total Alkalinity
4533-DR-01P & T Alkalinity
4533-01P & T Alkalinity
7240-02P & T Alkalinity
3467-01*†P & T Alkalinity
7515-01P, T, & OH Alkalinity
ALUMINUM A pink to red color will form when aluminum reacts with Eriochrome Cyanine R at pH 6.
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
39
Page 40
Ammonia Nitrogen - Bromine
Individual Test Kits
Code 3304-01
Order Code
Test System
(Detailed On Pages 6-7)
Range/Sensitivity
# of Tests
(# Reagents)
Reagent Refill
Order Code
Shipping Code
(Weight/Lbs)
AMMONIA NITROGEN Two colorimetric methods are available. Nessler’s reagent reacts with ammonia to form a yellow to brown color; salicylate
reacts to form a blue color, which in combination with the yellow reagent color produces colors from yellow to blue. The salicylate method is
preferred for salt water analysis and does not contain mercury salts as does the Nessler method.
ARSENIC The procedure requires about 15 minutes and employs a test strip. Inorganic As+3 and As+5 are converted to arsine gas. This
reacts with the test strip in a closed container and produces yellow to brown colors on the strip. The strip color is compared to a color chart to
determine concentration in ppb.
BACTERIA See Microbiological Testing section pages 36-38.
BLEACH (See Chlorine Bleach)
BROMINE Bromine may be tested using color development with DPD, or by a ferrous ammonium sulfate titration in the presence of DPD
indicator. The 6824 kit uses glycine to enable the user to separate bromine and chlorine. The 3624 titration kit uses one sample size to test
chlorine and one to test bromine. It includes a 1:10 dilution for determination of concentrations of 100 ppm or higher.
7172-02Dropper Bottle1 drop = 10, 25, or 50 ppm Cl
7247-01Dropper Bottle1 drop = 2, 5, or 10 ppm Cl
Test System
(Detailed On Pages 6-7)
Dropper Bottle
Dropper Bottle
Direct Reading Titrator
Range/Sensitivity
2
1 drop = 2 ppm EDTA
1 drop = 2 ppm NTA
1 drop = 5 ppm EDTA
1 drop = 5 ppm NTA
–
0–20,000 ppm/400 ppm
0-20 ppt/0.4 ppt Salinity50 at 20 ppt (2)R-7459-02R1 (1)
–
–
# of Tests
(# Reagents)
50 at 50 ppm (2)R-7297-DR-01R1 (1)
100 (3)R-7144-01R1 (1)
100 (3)R-7143-01HF (1)
50 (2)R-3468-01NH (1)
50 at 200 ppm (4)R-4503-DR-02R1 (1)
120 at 100 ppm (5)R-7172-02R1 (2)
120 at 10 ppm (5)R-7247-01R1 (1)
Reagent Refill
Order Code
Shipping Code
(Weight/Lbs)
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com41
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
Page 42
Chlorine - Chlorine
Individual Test Kits
Code 3670-01
Order Code
CHLORINE Free, Combined and Total Chlorine may be determined using DPD with either colorimetric or titrimetric methods. These
determinations are generally limited to concentrations of 0–10 ppm, although the FAS titration can test higher concentrations by dilution or with
the addition of more DPD indicator. Higher concentrations require the iodometric titration, whereby the sample is acidified and iodide is added,
which is oxidized by chlorine to iodine and is titrated with a standard thiosulfate solution. Iodometric determinations will only test total chlorine.
FREE & TOTAL
3308-01*DPD Tablet
3312-01*DPD Tablet
3313-01* DPD Tablet
3314-01*DPD Tablet
3328-01DPD Tablet
3670-01
DC1200-CL
3670-01-LI
DC1200-CL-LI
DPD FREE CHLORINE, MONOCHLORAMINE, DICHLORAMINE, & TOTAL CHLORINE
3316-01DPD Tablet
DPD FREE, MONO & DICHLORAMINES, TOTAL CHLORINE, pH
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
2979Chlorine Test Strips0, 0.5, 1, 3, 5 ppm Total Cl50 (1)R-2979
Test System
(Detailed On Pages 6-7)
Direct Reading Titrator
Dropper Bottle Titration
Range/Sensitivity
0–10 ppm/0.2 ppm Cl or Br
0–100 ppm/2 ppm Cl or Br
1 drop = 0.2 or 0.5 ppm Cl50 (3)R-7514-01NH (1)
# of Tests
(# Reagents)
50 at 10 ppm (3)R-3624-01NH (1)
Reagent Refill
Order Code
Shipping Code
(Weight/Lbs)
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
43
Page 44
Chlorine Dioxide - Copper
Reagent Tip:
Determine when your reagent
was made and bottled. The first
Individual Test Kits
two numbers of a lot number
signify the week, the third is the
year the reagent was made.
Thus 506XXX was made in the
50th week of 2016. For more
details see page 76.
Code 6616-01
Order Code
CHLORINE DIOXIDE The colorimetric kits use DPD to determine chlorine dioxide. Glycine is added in the method to remove free chlorine
interferences. Chlorite up to 1,000 ppm and chlorine up to 2 ppm will not interfere with the test strip determinations.
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com44
Page 45
Cyanide - Glutaraldehyde
TWO CHOICES
FOR REFILLS:
1. For a complete set,
add “R-” to the kit
number.
2. For individual
reagents, order by the
code on the reagent.
See pages 76-83 for
a list of kit reagents.
Individual Test Kits
Code 6701-01
Order Code
CYANIDE The cyanide is first reacted with a chlorine donor to form cyanogen chloride, which then reacts with pyridine-barbituric acid to form a
red-blue color. The test is also applicable as a screening test for concentrations up to 250 ppm.
GLUTARALDEHYDE High concentrations are determined by a titration with sulfuric acid after reaction with sulfite.
7064-01Direct Reading Titrator1 mL = 250 ppm Glutaraldehyde25 (5)R-7064-01R2 (3)
Test System
(Detailed On Pages 6-7)
Colorimeter0–2.0 ppm/0.03 ppm Fl
Range/Sensitivity
Free CN–
Formaldehyde
# of Tests
(# Reagents)
50 (5)R-7387-02R1 (3)
–
100 (2)R-3674-01LQ (7+5)
100 (3)R-6701-01LQ (2+5)
Reagent Refill
Order Code
Shipping Code
(Weight/Lbs)
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
45
Page 46
Hardness - Hydrazine
Individual Test Kits
Hardness originally referred
to the ability of water to
lather with soap. The more
calcium and magnesium
ions present, the “harder” it
was to produce a lather.
Code 4482-LI-02
Order Code
HARDNESS EDTA titration is used for all hardness determinations, with a red to blue endpoint. Both total and calcium hardness buffers include
inhibitors to eliminate metal interferences. All results are as CaCO3; some kits also express results as gpg. The 3609, which is recommended for
salt water analysis, includes a conversion factor for Ca++. The -LI suffix indicates an all liquid kit; -LT indicates a liquid buffer and tablet indicator.
3609-01Fresh & Salt Water
4482-DR-LI-01Total Hardness
4482-LI-02Total Hardness
4482-DR-LT-01Total Hardness
4824-LT-02Calcium, Magnesium, Total
4824-DR-LT-01Calcium, Magnesium, Total
3037-DR-01Low Range Total Hardness
7171-02Total Hardness
7246-02Total Hardness
Test System
(Detailed On Pages 6-7)
Calcium Hardness
Direct Reading Titrator
Direct Reading Titrator
Dropper Bottle
Direct Reading Titrator
Hardness
Dropper Bottle
Hardness
Direct Reading Titrator
Direct Reading Titrator
Dropper Bottle
Dropper Bottle
Range/Sensitivity
0–200 ppm/4 ppm CaCO
0-2,500 ppm by dilution
0–200 ppm/4ppm CaCO3
Liquid indicator
1 drop = 10 ppm or 1 gpg CaCO3
Liquid indicator
0–200 ppm/4 ppm CaCO3
Tablet indicator
1 drop = 10 ppm or 1 gpg CaCO3
Tablet indicator
0–200 ppm/4 ppm CaCO3
Tablet indicator
0–10 ppm/0.2 ppm CaCO
1 drop = 10, 25, or 50 ppm CaCO
1 drop = 2, 5, or 10 ppm CaCO
3
3
3
# of Tests
(# Reagents)
50 (3)R-3609-01R1 (1)
50 at 200 ppm (3)R-4482-DR-LI-01R1 (1)
50 at 200 ppm
or 20 gpg (3)
50 at 200 ppm (3)R-4482-DR-LT-01R1 (1)
50 at 200 ppm
or 20 gpg (5)
50 at 200 ppm (5)R-4824-DR-LT-01R1 (1)
50 at 10 ppm (3)R-3037-DR-01R1 (1)
3
100 (3)R-7171-02R1 (1)
100 (3)R-7246-02R1 (1)
Reagent Refill
Order Code
R-4482-LI-02R1 (1)
R-4824-LT-02R1 (1)
Shipping Code
(Weight/Lbs)
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com46
Page 47
Hydrogen Peroxide - Lead
Code 3347-01
Individual Test Kits
Order Code
Test System
(Detailed On Pages 6-7)
Range/Sensitivity
# of Tests
(# Reagents)
Reagent Refill
Order Code
Shipping Code
(Weight/Lbs)
HYDROGENPEROXIDE Although peroxide may be tested colorimetrically with DPD, the most common method is iodometric titration using a
standard thiosulfate solution. Both methods are offered.
LEAD The presence of lead in solder is detected by the reaction of a solder sample with acid and sodium rhodizonate.
3582-01Spot Plate
Yes/No100 (3)R-3582R1 (2)
Plumbing Inspector Kit
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com47
Page 48
Manganese - Molybdenum
Individual Test Kits
Molybdenum x 1.6 = Molybdate
Sodium Molybdate Dihydrate x 0.4 = Molybdenum
Code 6628-01
Molybdate x 0.63 = Molybdenum
Order Code
MANGANESE The 1-(2-pyridylazo)-2-naphthol(PAN) method forms an orange complex with manganese. Metal interferences with the PAN
method can be eliminated using the #7104 Cyanide Inhibitor Package, sold separately.
3588-02PAN
3682-01
DC1200-MN
MICROBIOLOGICAL TESTING See section pages 36-38.
MOLYBDATE/MOLYBDENUM There are three colorimetric methods and one titration method available. The 6628 uses Xanthogonate to form
a pink color with molybdate. Thioglycolate forms a yellow color for low to high determinations. The 3628 uses a new test strip technology that
reads 0, 0.5, 1, 2 and 5 ppm. Results are available in about 1 minute. The 3632 titration employs citric acid with a red to yellow color change. The
sample size may be changed to vary the equivalence.
1 drop = 2 or 20 ppm Molybdenum50 (3)R-3632-01LQ (2+5)
0-30 ppm/0.1 ppm Molybdenum50 (3)R-3676-01
# of Tests
(# Reagents)
100 (2)R-6628-01R1 (1)
50 (2)R-3346-01NH (1)
Reagent Refill
Oder Code
DC1200-MN
DC1200-MO
Shipping Code
(Weight/Lbs)
R3 (7+5)
R3 (7)
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com48
Page 49
Code 3354-01
Individual Test Kits
Nitrate Nitrogen - Nitrite, Sodium
The current EPA limit
for nitrate is 10 ppm
as nitrogen. Multiply
nitrogen readings by
4.4 to convert reading
to nitrate.
Order Code
Test System
(Detailed On Pages 6-7)
Range/Sensitivity
# of Tests
(# Reagents)
Reagent Refill
Oder Code
Shipping Code
(Weight/Lbs)
NITRATE NITROGEN The nitrate is reduced to nitrite by cadmium or zinc and this undergoes diazotization/coupling to form a pinkish color. All kits
below use cadmium except #3354, which uses zinc and which also contains a reagent that eliminates nitrite interference. Kit #3519 tests both
nitrate and nitrite. The kit #3119 uses one comparator that contains both nitrate and phosphate standards. The phosphate method in kit #3119
is an ascorbic acid reduction. See page 16 for Total Nitrogen Digestion Tube Test.
3119-01Cadmium Reduction
Nitrate/Phosphate
LRC Comparator
3615-01Cadmium Reduction,
Nitrate/Nitrite
0.2, 0.4, 0.6, 1.0 ppm NO
0.2, 0.4, 0.6, 1.0 ppm PO
–N;
3
3
–
4
0, 0.2, 0.4, 0.6, 0.8, 1.0 ppm NO
–
–N50 (2)R-3615-01R1 (2)
3
Nitrate: 40 (2)
Phosphate:
50 (2)
R-3119-01R1 (2)
–
LRC Comparator
3519-01Cadmium Reduction
Octa-Slide 2 Comparator
3354-01Zinc Reduction
Octa-Slide 2 Comparator
3677-01
DC1200-NA
Cadmium Reduction
Colorimeter
0.25, 0.5, 1.0, 2.0, 4.0, 6.0, 8.0, 10.0 ppm NO
0.0, 1.0, 2.0, 4.0, 6.0, 8.0, 10.0, 15.0 ppm NO
0–3.0 ppm/0.05 ppm NO
–
–N50 (2)R-3677-01R1 (7)
3
–
–N40 (3)R-3519-01R1 (1)
3
–
–N50 (2)R-3354-01NH (2)
3
NITRITE NITROGEN As with nitrate, above, the diazotization/coupling reaction is used to form a pink color with nitrite.
NITRITE, SODIUM Sodium nitrite is titrated using one of two methods. After acidifying the sample, permanganate will oxidize nitrite. When all of
the nitrite is oxidized, the permanganate turns the sample pink. Ceric Ammonium Nitrate (CAN) also oxidizes the nitrite in the presence of ferroin
indicator. The endpoint is orange to blue. The CAN method is preferred if glycol is present.
7101-DR-01Permanganate
Direct Reading Titrator
7101-01Permanganate
Dropper Pipet
3036-DR-02CAN
Direct Reading Titrator
7183-02CAN
Dropper Bottle
0–1000 ppm/20 ppm NaNO
1 drop = 50 or 100 ppm NaNO
0–1000 ppm/20 ppm NaNO
1 drop = 50 ppm NaNO
2
2
2
2
50 at 1000
ppm (2)
50 at 1000 or
2000 ppm (2)
50 at 1000
ppm (2)
50 at 1000
R-7101-DR-01R1 (1)
R-7101-01R1 (1)
R-3036-DR-02R1 (1)
R-7183-02R1 (1)
ppm (2)
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
49
Page 50
Oxygen, Dissolved - pH
It is important in all drop titrations to hold the
titrant vertically. This ensures proper drop size.
Individual Test Kits
Code 5860-01
Order Code
Test System
(Detailed On Pages 6-7)
Range/Sensitivity
# of Tests
(# Reagents)
Reagent Refill
Oder Code
Shipping Code
(Weight/Lbs)
OXYGEN, DISSOLVED The azide modification of the Winkler method is a modified iodometric titration whereby oxygen, in the presence of a strong
alkali, oxidizes manganese, which in turn reacts with iodide to form iodine. This is titrated with a standard thiosulfate solution in the presence of a
starch indicator to enhance the endpoint. Azide eliminates nitrite interference.
5860-01All liquid reagents
Direct Reading Titrator
0–10 ppm/0.2 ppm O
2
50 at
10 ppm (5)
R-5860-01R1 (2)
OZONE DPD reacts with ozone, but any other oxidizers will interfere. The Indigo Trisulfonate method includes a step to eliminate chlorine
interference, but bromine will interfere. It is preferred for the analysis of salt water samples.
3678-01
DC1200-OZ
Indigo Trisulfonate
Colorimeter
0–0.4 ppm/0.04 ppm O
3
100 (3)R-3678-01NH (7)
PERACETIC ACID/HYDROGEN PEROXIDE This test is a combination of two separate titrations. The first is a cerium titration of peroxide. The
second is an iodometric titration of peracetic acid.
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com50
Page 51
pH
pH must be controlled and monitored because it plays an
essential role in almost all chemical and biological processes.
pH indicators work in a specific range. Samples
with a pH above the range of an indicator
may match the highest standard on the
comparator; samples below the range may
match the lowest standard.
Individual Test Kits
Code 5858-01
LaMotte pH Test Kits
The “Precision Wide Range” pH kit includes the Octa-Slide comparator and reagents to provide
100 tests. Other pH test kits consist of an Octa-Slide Comparator, and a reagent for 50 tests.
LaMotte Company has been supplying laboratory quality pH indicator tests to professional analysts for more
than eighty years; these are the most reliable, economical pH test kits available. Simply fill the tube to the
mark with the sample water, add several drops of indicator, and compare the resulting color against the eight
permanent color standards in the comparator.
How To Select The Right pH Kit:
Single or Wide Range?
Single range kits cover a range of 1.4 pH units in 0.2 unit increments (0.1 unit sensitivity). Wide range kits
cover pH units in increments of 0.5.
See Instrument
Section, pages 22-30
for pH meters.
Which Range?
Choose a kit in which the midpoint of the range covered is as close to the average or optimum pH value of the
sample water. If this value is unknown, choose the Precision Wide Range Kit.
Indicators specific to a particular pH range allow colorimetric determination of pH. If the water to be tested is
cloudy, one may wish to use a pH meter.
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com51
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
Page 52
Phosphate - Phosphate
Individual Test Kits
Code 3114-02
Order Code
Test System
(Detailed On Pages 6-7)
Range/Sensitivity
# of Tests
(# Reagents)
Reagent Refill
Oder Code
Shipping Code
(Weight/Lbs)
PHOSPHATE There are 3 colorimetric test methods. In two, a phosphomolybdate complex is reduced by stannous chloride or ascorbic acid to
produce a blue color. In a third, phosphate forms a yellow complex with vanadomolybdate.
PHOSPHATE (TOTAL) Polyphosphates (acid-hydrolyzable or condensed) and phosphonates (organic phosphates) are reverted
100 (2)R-3679-01R2 (7)
50 (2)R-3121-02R1 (1)
50 (2)R-3114-02R1 (1)
50 (2)R-7416-02R1 (1)
50 (2)R-4408-01LQ (1)
50 (2)R-7068-01LQ (1)
50 (1)R-4401-02R1 (1)
HF (2)
using the reagents and apparatus in the 7884 Auxiliary Phosphate kit. The polyphosphates require boiling or microwaving with
acid and subsequent neutralization; the phosphonates require the same, but with the addition of an oxidizer in the boiling/
microwaving step. Once reverted to orthophosphate, any of the tests in the orthophosphate section above may be used for
analysis. See page 17 for Total Phosphorus Digestion Tube Tests.
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com52
Page 53
Phosphonate - Potassium
Code 7625-01
Individual Test Kits
Order Code
Test System
(Detailed On Pages 6-7)
Range/Sensitivity
# of Tests
(# Reagents)
Reagent Refill
Oder Code
Shipping Code
(Weight/Lbs)
PHOSPHONATE The Chromazurol S method may be used for Dequest (xo), Bayhibit (CAS), Belcor 575 (xo) and Belsperse 161 phosphonates
(CAS). An additional liquid acid is included for very high alkalinity samples. It also includes a fluoride inhibitor reagent.
The 7611 sulfate interference suppressor kit uses barium precipitation and filtration to eliminate sulfate from the phosphonate test.
7625-DR-01CAS
0–20 ppm/0.4 ppm HEDP/PBTC50 at 20 ppm (5)R-7625-DR-01R1 (1)
Direct Reading Titrator
7625-01CAS
Dropper Pipet
7530-DR-01XO
1 drop = 1.25 ppm HEDP
50 at 20 ppm (5)R-7625-01R1 (1)
1 drop = 1.4 ppm PBTC
0–20 ppm/0.4 ppm NaAMP50 at 20 ppm (5)R-7530-DR-01R1 (2)
Direct Reading Titrator
7530-WT-01XO
1 drop = 1 ppm NaAMP50 at 20 ppm (5)R-7530-WT-01R1 (2)
Dropper Bottle
POLYPHOSPHATES A colorimetric method is available for waters where metal interference is unlikely. An excess of iron is added to the solution
containing polyphosphate. The iron is complexed and the remaining iron is determined. The polyphosphate concentration is derived from the iron
concentration.
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com53
Page 54
QAC - Sulfate
Individual Test Kits
Many wood treating
companies use QAC
kits to monitor their
products because the
wood preservatives
react similarly to QAC.
Code 3043-DR-01
Order Code
QAC Two methods are available. A masked bromphenol blue indicator is added to the sample and turns green. Sodium tetraphenyl-boron is
added to complex the QAC and the color changes to red. This method is best suited to higher QAC concentrations. A poly-electrolytic titration, like
the one used for polyquat, is used for low to high concentrations.
0-1,000 ppm/20 ppm
0-5,000 ppm/100 ppm with dilution
1 drop = 2, 5, or 10 ppm
Alkyl dimethyl benzyl ammonium chloride
5, 10, 20, 30, 40, 60, 80, 100 ppm SiO
20, 40, 60, 80, 100, 120, 160, 200 ppm SO
2
–
4
2
2
–
4
# of Tests
(# Reagents)
50 at 500 ppm
(2)
50 at 1,000 ppm
(2)
100+ (5)R-7057-01R1 (2)
50 (4)R-4463-01R1 (1)
50 (1)R-7778-01R1 (1)
100 (1)R-3683-01R1 (6)
Reagent Refill
Oder Code
R-3043-
DR-01
R-3042-01NH (1)
Shipping Code
(Weight/Lbs)
NH (1)
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com54
Page 55
Sulfide - Zinc
Code 7391-02
Individual Test Kits
Order Code
Test System
(Detailed On Pages 6-7)
Range/Sensitivity
# of Tests
(# Reagents)
Reagent Refill
Oder Code
Shipping Code
(Weight/Lbs)
SULFIDE Both kits use the Pomeroy methylene blue method for analysis. The colorimetric method uses color standards to read total sulfide.
Total, dissolved and hydrogen sulfide can be separated in the titration test. The total sulfide is determined using a color dye which is added to
an unreacted sample until it matches a reacted sample. The same procedure is used for dissolved sulfide, after insoluble matter is removed by
aluminum floc. Hydrogen sulfide is determined by measuring pH and multiplying the dissolved sulfide concentration by a pH correction factor.
4456-01Total Sulfide
0.2, 0.5, 1.0, 2.0, 5.0, 10.0, 15.0, 20.0 ppm S
2–
50 (3)R-4456-01R1 (1)
Octa-Slide 2 Comparator
4630†*Total, Dissolved &
Hydrogen Sulfide
1 drop = 1.0 or 0.1 ppm S2– or H
S70 at 10 ppm (8)R-4630†*LQ (10)
2
Dropper Pipet
SULFITE An iodide-iodate titrant oxidizes sulfite to sulfate under acid conditions, until all of the sulfite is reacted. The titrant then reacts with
starch to form a blue color signifying the endpoint.
2
7175-DR-01 Direct Reading Titrator0–100 ppm/2 ppm SO
7175-01Dropper Pipet1 drop = 5 ppm SO
–
3
2
–
3
7132-01Dropper Bottle1 drop = 2, 5, or 10 ppm SO
2
–
3
50 at 100 ppm
(3)
50 at 100 ppm
R-7175-
DR-01
R-7175-01R1 (1)
(3)
100+ (3)R-7132-01R1 (1)
R1 (1)
TANNIN/LIGNIN Tungstophosphoric and molybdophosphoric acids are reduced by tannins and lignins to form a blue color.
7831-01Octa-Slide 2 Comparator1, 2, 3, 4, 5, 6, 8, 10 ppm Tannin or lignin like
50 (2)R-7831-01R1 (1)
substances
TOLCIDE PS BIOCIDE This kit was developed in cooperation with Solvay, for the determination of tetrakishydroxy-methyl phosphonium sulfate
(THPS). The iodometric titration may be used for fresh or salt water in oilfields, towers, pulp and paper, etc.
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com55
Page 56
Aquaculture & Aquarium Waters
Fish Farms, Hatcheries, Research, Hobbyists, Retailers,
Ornamental Fish Culturists...
Model AQ-2, Order Code 3633-04 (Ship Code R3; 16 lbs.)
Reagent Refill, Order Code R-3633-03 (Ship Code R3)
A complete outfit for pond fish culture, ideal for fresh water analysis. Nine critical test
factors can be determined on-site, efficiently and accurately. Designed with field analysis
as a priority; all reagents, components, and accessories are arranged in pre-drilled foam.
Short form instructions are provided in a handy adhesive lid label for easy access. Long
form instructionbooklet provides detailed instructions and test kit diagram. Unit is supplied complete with labware, accessories, sampling bottle, and reagents.
Model AQ-4, Order Code 3635-04 (Ship Code R2; 16 lbs.)
Reagent Refill, Order Code R-3635-03 (Ship Code R2)
Provides equipment to monitor nine parameters most critical for the salt water aquaculturalist.
Reagents, labware, and accessories are mounted in foam for convenient test selection and portability. Short form lid label instructions are always available for quick reference, and a long form
booklet provides detailed instructions with kit diagram. Unit is supplied complete with labware,
accessories, sampling bottles, and reagents.
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
Page 57
Elementary, Secondary, Vocational, Outdoor, & College Science
Water Quality Educator
Monitoring Outfit
Order Code 5870-01 (Ship Code R1; 14 lbs.)
Always the first kit recommended for beginning a
water quality monitoring study. The Water Quality
Educator and Monitoring Outfit provides kits for
seven basic water quality test factors and exceptional support material, all housed in a rugged field
carrying case.
The Monitor’s Handbook, a 71-page reference guide,
includes all the information needed to set up a water
quality monitoring program. The handbook covers
test procedures and means to interpret results.
The Water Quality Educator CD-ROM, now for PC
and Macintosh computers, incorporates Quick
TimeTM animations, still photos, written and audio
information to provide step-by-step instructions
for the tests included. Students receive both visual
and verbal instructions and can repeat material as
often as necessary. This effective “pre-lab” activity
helps prepare students for water quality testing in
the field or in the classroom.
The CD also provides benchmark data for each
test factor for comparison of results obtained using LaMotte test kits in the field. Students enter
their results and receive information on what type
of water quality is indicated by their data as well as
typical causes and effects of higher and lower levels.
Students performing the Leaf Pack Experiments learn to
design, implement, and analyze a scientific investigation by
discovering how aquatic macroinvertebrates indicate the
overall health of a stream ecosystem. The Leaf Pack Experiments Kit is totally reusable and flexible. Adaptable to varying
time constraints, number of students, and grade levels, it
is geographically friendly and complete. All the apparatus
and guides necessary for collecting, sorting and identifying
are included. The kit includes a comprehensive Instructor’s
Manual - featuring background material on stream ecology,
a glossary, diagramed instructions, experiment ideas, and
full color macroinvertebrate flash cards. Developed by the
Stroud Water Research Center in cooperation with LaMotte
Company.
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
57
Page 58
Environmental Studies
Elementary, Secondary, Vocational, Outdoor & College Science
Plankton Net
15” (38.1 cm) tall,
5” (12.7 cm) dia. mouth
Combination Kits
Order Code 1063; (2 lbs.)
Cone-shaped net of 10 mesh,
153 micron nylon cloth. Minute
plankton are collected and can
be observed in the removable,
clear conical graduated tube.
Two tubes provided. Net mouth
is braced by a sturdy stainless
steel ring and harness.
Kick-Net
Kick-Net, complete with poles
Order Code 0021-P (8 lbs.)
Kick-Net only Order Code 0021 (4 lbs.)
This 1x1 meter square, 500 micron, tan mesh net is
designed to meet the requirements of groups performing US EPA Rapid Bioassessment Protocols for
benthic invertebrates.
Secchi Disk
Disk with black & white quadrants & calibrated line
Order Code 0171-CL (3 lbs.)
Weighted 20 cm diameter disk has a braided stretch-resistant
line marked every half meter and at every meter up to 20 meters.
A popular outfit for the testing and
study of freshwater systems such
as ponds, lakes, wetlands, rivers,
streams, etc. This field-friendly
outfit contains individual test modules, water sampling bottles, three
supplemental handbooks, and data
sheets.
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
Elementary, Secondary, Vocational, Outdoor, & College Science
The Tour Series
Each Tour is a complete, hands-on, science curriculum with safe, simple TesTabs® tablet tests. Each Tour includes lecture materials, illustrated handouts, teacher tips, test procedures, TesTab reagents, data sheets, and games to reinforce key concepts. The Tour Series is designed for grades 4 through
8 environmental science education. The Goal of the Tour series is for students to discover, examine, measure, and compare physical and chemical
properties. Students learn basic analytical methods while performing a scientific investigation.
Shore Tour
Shore Tour, Order Code 5939 (Ship Code NH; 5 lbs.)
Reagent Refill, Order Code R-5939 (Ship Code NH; 1 lb.)
Five units teach students through classroom lectures and activities how their everyday actions affect the
ocean. Topics include an introduction to coastal ecosystems, oil spills, shoreline development and marine
debris. Includes teacher tested activities from EPA, NOAA, and The Marine Mammal Center, links to activities
and information from ocean experts, CD with printable handouts, data sheets, and more. Materials for 40
students working in groups.
Watershed Tour
Combination Kits
Watershed Tour, Order Code 5419 (Ship Code NH; 4 lbs.)
Reagent Refill, Order Code R-5419 (Ship Code NH; 1 lb.)
A classroom-based tour of a virtual watershed, designed for teachers who are unable to visit a stream with
their students. Students will “test” four stations along a river continuum to study how the river changes and
how human activities can influence water quality. Developed by the Stroud Water Research Center in cooperation with LaMotte Company. Materials for 30 students working in groups.
Topsoil Tour
Topsoil Tour, Order Code5425-01 (Ship Code NH; 4 lbs.)
Reagent Refill, Order Code R-5425-01 (Ship Code NH; 1 lb.)
Investigate the physical and chemical properties of soil. Each student on the Topsoil Tour completes seven
units while conducting his/her own soil tests for soil texture, pH, nitrogen, phosphorus, and potassium. Tablets
and sample test bags for 50 students.
Pondwater Tour
Pondwater Tour, Order Code 5418 (Ship Code R1; 4 lbs.)
Reagent Refill, Order Code R-5418 (Ship Code R1; 1 lb.)
A great introduction to the study and measurement of changes in the water quality of a lake, stream, pond,
aquarium, or even a fish bowl. Tests are included for pH, dissolved oxygen, nitrate, and ammonia. Students
test variables and investigate natural processes that create changes in water quality. Tablets and sample
test bags for 50 students.
Tapwater Tour
Tapwater Tour, Order Code 3608 (Ship Code NH; 4 lbs.)
Regent Refill, Order Code R-3608 (Ship Code NH; 1 lb.)
An exciting investigation of water quality examining the chemical properties of water directly from the tap.
Students learn the relationships between good and poor water quality while examining the pH, chlorine, hardness, copper, and iron of tapwater from their homes. Tablets and sample test bags for 50 students. Ideal for
educational outreach for public health/utilities.
Call For Our Science Education Products Catalog
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
59
Page 60
Environmental Studies
Elementary, Secondary, Vocational, Outdoor & College Science
AP® Water Quality Assessment Package
Order Code 5845-PKG (Ship Code NH (1)
The AP® Environmental Science WATER QUALITY ASSESSMENT PACKAGE is an extensive curriculum that
Combination Kits
uses the exploration of the Water Quality Index to teach students STEM-based skills that they
will apply through classroom and field activities to satisfy Section VI (Water
Pollution) of the AP® Environmental Topics Outline.
In a culminating field activity, students utilize appropriate techniques
and instrumentation to identify their watershed and perform chemi-
cal and biological analyses to determine the water quality index of
a local waterway.
The following environmental concepts are covered: watersheds, Water Quality Index, physical, chemical and biologi-
cal water quality parameters, nutrient loading, hydrological variables, watershed ecology, remediation measures,
and point, non-point pollution sources.
In four classroom activities, students
use actual data from the Kansas River
watershed to:
Water Quality Assessment Curriculum Module, Code 5845
(sold separately)
Nutrient – TTC/MacConkey BioPaddles (Code 5553) for coliform
testing
Salt/TDS/Temp Tracer (Code 1749-01) for temperature and TDS
determination
Teacher Resource CD-ROM
The Teacher Resource CD-ROM (included with the Water Quality Index Module) contains:
Teacher/Student guide Water Quality Test Procedures STEM Extension Activities Chemical Reactions Data Spreadsheets Glossary Graphics Files PowerPoint Presentations and Quick Time iPad/iPod Videos
Also includes a Free LaMotte BioPaddle Colony Identification App which lets users capture the BioPaddle image to compare the “unknown” microbe growth on the BioPaddle to a library of photos of
“known” microbe colonies.
Earth Force Low-Cost Water Monitoring Kit
Water Quality Educator, Code 5870-01 (See page 57)
A popular, economical tool for learning the basics of water quality.
Students will have fun analyzing sample water for pH, Dissolved Oxygen, Biochemical Oxygen Demand, Temperature, Turbidity, Nitrate,
Phosphate, and Coliform Bacteria. Includes a manual with step-by-step
diagramed instructions and easy-to-use laminated color chart. All the
necessary apparatus and non-hazardous TesTabs to test ten water
samples (three samples for Coliform). Ideal for educational outreach.
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
Model TK-10, Order Code 8225-01 (Ship Code R2; 2 lbs.)
Reagent Refill, Order Code 8228-H (Ship Code R2; 2 lbs.)
This simple, single-reagent dropper pipet kit measures caustic soda for
cleaning dairy bottles, cans, storage tanks, etc. Reagents for 50 tests. Kit uses
neutralization test method. Dilution step permits measurement of two ranges:
0.25%/drop caustic soda by weight 0.01%/drop sodium oxide
Chemically treated paper strips change to indicate sanitizer level. Strips and color chart are packaged in a
waterproof plastic vial. 2951 is specifically formulated to read all types of QAC.
Test Papers
FactorCode (Qty.)Range
Chlorine4250-BJ (200) 10, 50, 100, 200 ppm
Iodine2948-BJ (200) 12, 25, 50, 100 ppm
QAC2951 (100)50, 100, 200, 400 ppm
High Range QAC 2951-HR (50)200, 400, 600, 1000, 1500 ppm
High Range
QAC3072-J (100) 0, 100, 200, 300, 400, 500 ppm
High Range Chlorine3031 (50)0, 50, 100, 250, 500, 800 ppm
Dual Range QAC2934 (50)LR: 0, 10, 20, 40, 80 ppm
3000LR (50)0, 5, 10, 20, 30, 50
3000HR (50)0, 50, 100, 250, 500, 1000
HR: 0, 100, 200, 400, 800 ppm
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
For control of water supplies, cleaning
operations, and rinses
Model LDR, Order Code 3095-02
(Shipping Code LQ)
Seven important factors for monitoring incoming
water supplies, break, suds and bleach operations;
also rinse and sour operations. The pH (alkaline)
test uses a LaMotte Octet Comparator. The alkalinity tests, chlorine bleach and hardness test
utilize dropper pipet test methods. Reagents are
supplied for 50 tests of each factor.
3541-01 Spot test for presence/absence of Chlorine
7894-01 High Range–1 dr = 0.5% Cl
Total Hardness 1 drop = 1 gpg
Chlorine Strips 10, 50, 100, 200 ppm
Oxygenated Bleach 1 drop = 10 ppm
and Iron. Wide Range pH
Mid Range–1 dr = 0.05% Cl2
Low Range–1 dr = 0.005% Cl
2
2
R2
R2
R1
R1
FactorRangeApplication
Chlorine Bleach0.5%/dropAvailable chlorine in bleach
Hardness10 ppm or
1 gpg/drop
TurbidityYes/No (Soil)Presence of soil in solution
solutions
Water Supply
62
7250-01
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
Page 63
General Water Analysis
Laboratories, Government Agencies
SMART Water Analysis Laboratory
MODEL SCL-05, Order Code 1951-02 (Shipping Code LQ; 37 lbs.)
Reagent Refill, Order Code R-1951 (Shipping Code LQ; 10 lbs.)
This portable lab measures 24 water quality parameters for pollution detection, environmental studies, and industrial water and wastes. The SMART3 digital
colorimeter analyzes test sample color reactions and provides direct readouts for 15 factors. Titration tests performed with LaMotte’s Direct Reading
Titrators provide results directly in ppm for 6 additional factors. Digital meters measure pH and conductivity.
See specifications on next page.
Combination Kits
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
pH5-0034-01pH5pH 0–14
Conductivity5-0038-02CON50.0–19.99 mS
Also Available...
Description
Model SMART 3 Colorimeter,
without pH & Conductivity Lab
Meters
Reagent RefillR-1991LQ (10 lbs.)
Code
1991-01 SCL-04LQ (34 lbs.)
Model
Ship Code
(Wgt.)
64
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
Page 65
Industrial Waters
Water Treatment Companies, Engineers, Consultants
Combination Buret Outfits
In addition to our other standard products, LaMotte also packages combination buret style outfits. These outfits are packaged in cases made of
rugged ABS plastic in sizes to fit three to five burets and accessories. The automatic burets and accessories are mounted in plastic clips over a white
plastic workshelf in one half of the cabinet. The other half of the case is equipped with foam-lined shelves to hold additional tests or accessories.
Colorimetric and titrimetric tests may be added to the buret titrations.
To order, simply choose the desired test reagents from the list on page 66 and select any additional tests from the A - Z section (pages 39-55) or the
instrumentation section (pages 8-33). Squeeze valve (pinchcock) style burets are standard equipment with these kits, but glass or Teflon® stopcock
burets may be ordered for an additional charge.
Combination Kits
Model AB-152
Order Code 7643-01 (Ship Code LQ)
FactorMethodEquivalence (# Tests)
pHAlkaline Wide
PhosphateStannous
FactorMethodEquivalence (# Tests)
AlkalinityNeutralization1 mL = 1.0 mg (50+)
ChlorideArgentometric1 mL = 0.5 mg (50+)
Hardness Complexometric1 mL =6 0.25 mg (50+)
SulfiteIodometric1 mL = 1.0 mg (50+)
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
Range
Chloride
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
Page 67
Pool & Spa Waters
Professionals, Public Operators, Private Owners
Combination Kits
So simple, anyone can use it! Just fill disk with sample and Spin All test results in 60 seconds Precise wet chemistry Pre-measured reagents and sample amounts
For more information scan
the code shown here or go to
www.lamotte.com/spin for
videos and more information.
Free Chlorine
(ppm)
Range0 to 150 to 150 to 33.0 6.3 to 8.60 to 12000 to 2505 to 1500 to 3.00 to 3.00 to 60
Biguanide
(ppm)
Range0 to 700 to 2506.3 to 8.60 to 12000 to 2500 to 3.00 to 3.00 to 60
Total Chlorine
(ppm)
Biguanide Shock
(ppm)
Bromine
(ppm)
WaterLink® Spin Lab
Code 3576
A revolutionary new in-store lab is here! Now let the innovative WaterLink® Spin photometer do all
your pool and spa water testing for you. Just fill one unique Spin reagent disk with water and vital
tests are done automatically.
In just 60 seconds all the test results are transferred into the DataMate 10 software on your computer and analyzed to display results and recommend precise treatment instructions. Remove the
disk and you’re ready for the next customer.
This ground-breaking analysis system is so simple anyone can use it. Each sealed reagent disk
contains the precise amount of reagent needed to run a complete series of tests. No measuring
water, no mixing, no prep time or cleanup.
Chlorine Disk, Order Code 4330-H (50/pk)
pH
(pH)
Biguanide Disk, Order Code 4331-H (50/pk)
pH
(pH)
Calcium Hardness
(ppm)
Calcium Hardness
(ppm)
Total Alkalinity
(ppm)
Total Alkalinity
(ppm)
Copper
(ppm)
Cyanuric Acid
(ppm)
Iron
(ppm)
Copper
(ppm)
Borate
(ppm)
(ppm)
Iron
Borate
(ppm)
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
67
Page 68
Pool & Spa Waters
Professionals, Public Operators, Private Owners
Insta-TEST® Plus Strips
Combination Kits
The Insta-TEST® 3, PRO400, and 5-way pool and spa test strips are the
only strips of their kind that do not require any specific waiting period.
Just dip the strip in the pool or spa for accurate and reliable results.
The 3-way test strip measures for Free Chlorine or Bromine, Alkalinity
and pH all on one strip. The 5-way test strip measures Free Chlorine
or Bromine, Total Chlorine, Alkalinity, pH and Total Hardness. Both are
sold in vials containing 50 strips. The PRO400 provides 100 strips
and measures the Free Chlorine or Bromine, Total Chlorine, pH and
Alkalinity. The PopTop bottle features a patented desiccant liner covering its base and sides, which provides substantially better moisture
protection and eliminates the need for a loose desiccant bag. Another
feature is the hinged cap, which eliminates the problem of loose caps
getting wet. Each bottle has a 30 month shelf life. Individual units are
available through local retailers, which can be found on our website
www.lamotte.com/insta.
The Sodium Chloride Insta-TEST® strip is an easy one step procedure
for measuring Sodium Chloride in salt-water pools. Just dip and read
to get results in only 20 seconds. The strip measures salt water pool
samples over the range of 1,500 to 5,000 ppm. Each bottle contains
50 strips in a convenient, black PopTop bottle. A desiccant liner inside
the bottle protects the strips from moisture intrusion and UV light.
The Wide Range pH and Total Chlorine Insta-TEST® strip identifies
how far out of range a pool or spa sample may be, before a variety
of treatment chemicals and test reagents are consumed. The Wide
Range strip provides quick and reliable results in just 15 seconds. The
strips are designed to measure Total Chlorine from 0 to 50 ppm and
pH from 4 to 10.
See pages 34-35 for additional test strips.
PopTop bottles make
®
Insta-TEST
strips
even easier!
68
Code
2976Insta-TEST 3 Plus0 to 100 to 20—0 to 2406.2 to 9.0——12, 24 or 100NH
2977Insta-TEST 5 Plus0 to 100 to 200 to 100 to 2406.2 to 9.0 50 to 800—12 or 100NH
2978Insta-TEST PRO 400 Plus0 to 10 0 to 200 to 100 to 2406.2 to 9.0——12 or 100NH
2998Insta-TEST Salt——————1500 to
2987-G Insta-TEST Wide Range
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
Model
pH/Total Chlorine
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
Free
Chlorine Bromine
——0 to 50—4 to 10——12NH
Total
Chlorine Alkalinity
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
pH
Total
Hardness Salt
5000
Case
Pack Size
12 or 100NH
Ship
Code
Page 69
Professionals, Public Operators, Private Owners
DipCell Series
The LaMotte DipCell color comparator is available in a competitive lineup of
kits for the pool operator and service pro.The DipCell comparator is simple to
use. Just dip the comparator into the water to get a sample, add reagents, cap,
mix, and read chlorine and pH immediately. Six color standards are provided
for wide-range chlorine from 0.5-10.0 ppm. The six standards included for pH
range from 6.8 - 8.2.
A wide range chlorine DipCell measures Chlorine from 0.5 - 10 ppm Removable wall dividers inside the carrying case permit an easy upgrade
to larger 60 mL reagent sizes
“Handle-Top” carrying case is compact and rugged (7½” x 4½”) Liquid DPD and Phenol Red offered in large volumes to do 144 or 288 tests Color-coded instructions and reagents simplify analysis Separate titration tube for Alkalinity and Hardness avoids cleaning pH cell before each test Handbook included
Combination Kits
Pool & Spa Waters
Code/Model
7011-01/
DT-3
# of Tests
7013/DL-510.5-10.00.5-10.06.8-8.21 drop = 10 ppm1 drop = 20 ppmDrop countDrop count0-100R1
# of Tests
7014/DL-600.5-10.00.5-10.06.8-8.21 drop = 10 ppm1 drop = 20 ppmDrop countDrop count—R2
# of Tests
Free
Chlorine
0.5-10.00.5-10.06.8-8.2(This kit includes 50 DPD tablets for each Chlorine test)—NH
5050144—————
14414414470±70±70±70±50
288288288140±140±140±140±—
Total
Chlorine
pH
Calcium Alkalinity
Calcium
Hardness
Acid DemandBase
Demand
Cya
Ship
Code
Pool MGR. Series
All Tablet • Octa-Slide
Our rugged all tablet kit for the public pool operator. The precise Octa-Slide Com
parator system is used to comply with regulatory standards. The Pool MGR. Series
includes diagramed instructions, saturation index calculator, water quality handbook, and the eight-standard Octa-Slide Comparator system for chlorine and pH,
all in a tough, blow molded carrying case. The Pool MGR. tablet series is supplied
with sufficient tablet reagents for 50 tests for Free Chlorine, Total Chlorine, and pH.
Tablet reagents for 20 tests are provided for Alkalinity, Hardness, and Cyanuric Acid.
3368-NJ-01/PM-51-NJ0.5-10.00.5-10.06.8-8.260-40060-400Calc.0-100NH
3368-ABC-01/PM-51-NJ0.5-10.00.5-10.06.8-8.260-40060-400Acid/Base drop titration0-100NH
# of Tests
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
Free
Chlorine
5050502020Calc. From Alk test result20NH
Total
Chlorine
pH
Total
Alkalinity
Calcium
Hardness
Acid Demand
Calc.
Cyanuric
Acid
0-100NH
Ship
Code
69
Page 70
Pool & Spa Waters
Professionals, Public Operators, Private Owners
PRO250
Combination Kits
Our professional water analysis kits are supplied in durable, cases for years
of dependable service. Each unit features liquid reagent systems for chlorine and pH (capable of 280+ tests each). The liquid DPD reagent system is
provided to monitor chlorine, while pH is tested with a single liquid indicator.
Total Alkalinity, Calcium Hardness, Acid and Base Demand are analyzed with
drop count titrations. Cyanuric Acid is measured by turbidity. The PRO250
PLUS outfit includes all of the above plus Copper and Iron tests.
Every PRO250 SERIES kit includes color-coded caps to prevent mixups and
diagramed instructions to make testing a breeze. The Pool MGR. Water Quality
handbook and saturation index calculator are also included.
See the chart below for specifications.
Code/Model
7001-NJ-01/
PRO250-NJ
7002-NJ-01/
PRO250 PLUS-NJ
# of Tests
Free
Chlorine
0.2-3.0 &
0.5 -10.0
0.2-3.0 &
0.5 -10.0
288288288140+140+70 each1005050
Total
ChlorinepH
0.2-3.0 &
0.5 -10.0
0.2-3.0 &
0.5 -10.0
6.8-8.21 drop =
6.8-8.21 drop =1
Total
Alkalinity
10 ppm
0 ppm
Calcium
Hardness
1 drop =
20 ppm
1 drop =
20 ppm
Acid & Base
DemandCyaCopperIron
Drop count0-100––R2
Drop count0-1000.1-1.00.1-1.0R2
Ship
Code
ColorQ PRO 9 TESTAB® KIT
Model PRO 9, Order Code 2069 (Ship Code R1; 4 lbs.)
The unique, multi-test ColorQ hand-held photometer reads NINE pool and spa test factors directly on a digital display. Featuring an innovative dualoptic design, the ColorQ provides more accuracy and more test factors. The ColorQ eliminates the need to visually determine slight color variations or
use look-up tables, thus taking the guesswork out of poolside water analysis.
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
Page 71
Pool & Spa Waters
Professionals, Public Operators, Private Owners
Combination Kits
DPD TesTabs
As the only North American manufacturer of DPD tablets, LaMotte has replaced traditional foil-on-foil strip packaging with blister-style foil packaging. The
user can dispense each tablet into a small vial by pressing the tablet through the foil. This eliminates the need to manually tear open a foil packet and
carefully dispense the tablet. The package carries the customary 10 tablets per strip in a compact 3.35” x 1.35” size. In addition to the convenient package, the DPD #1R rapid dissolving formula for measuring Free Chlorine has been enhanced for faster dissolution. Listed below are visual grade tablets.
The liquid alternative to DPD tablets can be used with existing LaMotte chlorine comparators
or colorimeters. DPD 1A and DPD 1B are added to a 5 or 10 mL sample to test Free Available
Chlorine. DPD 3 is added to the reacted sample to measure Total Chlorine. Liquid reagents
are also available to measure pH, Hardness, Alkalinity, and Copper.
30 mL(1 oz.)CodeShip Code
DPD 1AP-6740-GNH
DPD 1BP-6741-GR2
DPD 3P-6743-GNH
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
60 mL (2 oz.) CodeShip Code
DPD 1AP-6740-HNH
DPD 1BP-6741-HR2
DPD 3P-6743-HNH
71
Page 72
Water & Wastewater
Municipal & Industrial Water & Wastewater Systems
HydraFrac Water Screening Kit
Order Code 7627 (Ship Code HF, R1; 25 lbs.)
The HydraFrac Water Analysis Test Kit is suitable for the measurement of possible residuals associated with oil and natural gas development processes,
Combination Kits
industrial activities, or agricultural operations in surface or groundwater. The test kit provides a simple, portable method for obtaining instant water
quality data for 15 parameters that could be associated with groundwater and surface water contamination. Expandable to over 80+ tests using the
SMART3 colorimeter (see page 8-9, 17-18 for more details about the SMART3).
72
FactorMethodRange (# Tests)
AcidityDropper Bottle1 drop = 0.1 or 1%
AlkalinityTest Strip0 to 240 ppm (25)
AmmoniaTest Strip0 to 6 ppm (25)
BariumBarium Chloride0 to 200 ppm (50)
ChlorideArgentometric0 to 30 ppm (50)
ChromiumDiphenylcarbohydrazide 0 to 1 ppm (50)
HardnessTest Strip0 to 180 ppm (25)
IronTest Strip0 to 5 ppm (25)
NitrateTest Strip0 to 200 ppm (25)
NitriteTest Strip0 to 10 ppm (25)
pHTest Strip0 to 14 pH (25)
SulfateBarium Chloride0 to 100 ppm (100)
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
FactorMethodRange (# Tests)
Instrumentation
Dissolved OxygenTracer Instrument0 to 20 ppm
pH/EC/TDSTracer Instrument
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
0 to 14 pH; 0 to 19.99 mS;
0 to 999 ppm
Page 73
Municipal & Industrial Water & Wastewater Systems
STORMWatch MS4 Water Screening Kit
Order Code 7449 MS4 Water Screening Kit
(Also available as individual reagent kits)
Order Code 7450 IDDE Accessory Kit
Instrumentation and reagent systems are currently available to provide a preliminary
screening of storm water outflow, and determine whether it is contributing to the
overall pollutant load as it relates to inorganic constituents. In many cases these
measurements can be made near the source, using handheld instrumentation,
test kits, and/or reagents.
Features
Fast - Most tests can be completed in under 2 minutes Easy - All kits and meters come with easy-to-follow instructions Unique Design - All-in-one kit that puts your testing needs together in one
easy to transport carrying case!
Scan here to see our
Stormwater MS4
Guidance video
Combination Kits
Water & Wastewater
Test FactorRange (# Tests)
Ammonia1.0 to 8.0 ppm (50)
Boron*0 to 0.80 ppm (50)
Chlorine*0 to 4 ppm (144)
Copper*0 to 7 ppm (50)
Fluoride*0 to 2 ppm (50)
Hardness1 drop=10, 25 or 50 ppm (100)
Phenols*0 to 6 ppm (50)
Potassium6 to 50 ppm (100)
Surfactants*0 to 8 ppm (100)
*Only available in Order Code 7450
MetersRange
Color0 to 200 cu
Conductivity0 to 199.9 µS/cm
pH0.00 to 14.00 pH
Turbidity0 to 500 FAU
TDS0 to 999 ppm
Corrosion Control Kit
Model CCK, Order Code 7436-01 (Ship Code R1; 7 lbs.)
Reagent Refill, Order Code R-7436-01 (Ship Code R1)
By determining corrosive conditions in water supplies, this test kit supports a water supplier’s lead in
drinking water abatement program. Each unit includes tests for P and T alkalinity, calcium hardness,
temperature, pH, phosphates, and total dissolved solids. Calculate saturation index by the Langelier
method to indicate the corrosive conditions in water supplies. The Model CCK Corrosion Control kit
is packaged in a portable carrying case for on-site use.
FactorMethodRange (# Tests)
Calcium HardnessComplexometric 0–200 ppm(50)
P & T AlkalinityNeutralization0–200 ppm (50)
OrthophosphateAscorbic Acid0.5–10 ppm (50)
Temperature——— –5° to +45°C (Unlimited)
Corrosion Index———By calculation via chart (50)
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
73
Page 74
Water Conditioning
Residential & Commercial Water Treatment Specialists
Customize Your Water Quality Sales Demonstrations.
Choose the Softener that Meets Your Needs!
LaMotte Model AT-Q Digital and AT Visual series outfits are the most popular and effective sales tools for on-site demonstrations. The tests clearly
demonstrate the benefits between untreated and treated water.
Combination Kits
AT-Q Digital Series
Featuring the ColorQ DW digital colorimeter
New digital versions
New rugged case
with locks
Fast & simple tests More custom options Competitive pricing
*Higher Concentrations by dilution; instructions included.
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
)
Soap
Consumption
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
Optional Add-On Kits and TDS Meter:
Chlorine (0.2-3.0 ppm
Nitrate (0-15 ppm), 50 Tests; Code 4-3004
TDS Meter, Code 5-0080 (see page 26
),
50 Tests; Code 4-3006
)
Page 75
Residential & Commercial Water Treatment Specialists
Demonstration Softener Units
Combination Kits
Water Conditioning
TM
Model S
Order Code 1002
Single chamber Filled with resin
Duo-Soft
Order Code 1022
Dual chamber Shipped empty
Order Code 1022-FLD
Dual chamber Filled with carbon
and resin
Water Quality Outfit
Model AR-42, Order Code 3590-03 (Ship Code R1, 7 lbs.)
The simplest, most economical way to measure several water
quality factors with a single, portable outfit. Ideal for service applications. Easily customized for your particular analytical needs.
Tests for pH, hardness, iron, and sulfide. Includes reagents for 50
tests each for pH, hardness, and sulfide; 100 tests for iron.
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
75
Page 76
How to use this section:
Code#Suffix (Indicating Size)Size
The reagent code number is followed by a letter which indicates the container size supplied for that reagent. The following table shows how those
letters correspond to container sizes - milliliters for liquids and grams
Reagent Refills
fo powder. When ordering a reagent, please include the appropriate letter suffix with the reagent code number to indicate the container size.
EXAMPLE: To order a 60 mL bottle of Phenol Red Solution (Reagent Code
Number 2211), use the letter “-H”, and order by code number “2211-H”.
NOTE: A reagent is available only in the sizes indicated under the kit’s
listing in this section.
How to Determine Reagent Manufacture and
Expiration Dates
On the lower, left corner of the label of each LaMotte reagent is a six
(sometimes seven), digit number. This is not a code number, but the lot
number of that reagent. A lot number records the date of manufacture
and identifies the reagent as part of a specific batch of reagent produced
on that date. The first two digits of the lot number identify the week, and
the third digit identifies the year of manufacture.
If the shelf-life of your reagent is unknown, one year from the date of
manufacture is still a good rule of thumb.
6483-H
FIRST AID EYE OR SKIN
Immediately flush with water
for 15 minutes.
INTERNAL- Drink plenty
of water. Call a doctor.
WARNING: This product
contains Phenolphthalein,
a chemical known to the
State of California to cause
cancer.
LOT 521109
802 Washington Ave., Chestertown, MD 21620 USA • 410-778-3100 • MSDS: lamotte.com/msds
Lot# (Including Week, Year, & Batch Information)
-A
11mL1 gram
-B
22 mL2 grams
-C
55 mL5 grams
-D
1010 mL10 grams
-E
1515 mL15 grams
-F
2020 mL20 grams
-G
3030mL30 grams
-H
6060mL60 grams
-J
120120mL120 grams
-K
250250-285mL1200-500 grams
-L
500470-525mL450-500 grams
-M
1000950-1000mL—-
-N
—-3800mL—-
Conductivity
Neutralizing
Solution
WARNING! FLAMMABLE
Read side panel before use.
60 mL
Read MSDS
39% Isopropanol, CAS
67-63-5; 5% Citric acid,
CAS 77-92-9; <0.1%
Phenolphthalein, CAS
77-.09-8. Harmful if
swallowed or inhaled.
Do NOT use near heat
or flame. Avoid contact
with eyes. Keep
container tightly closed
and out of reach of
children.
Kit CodeReagent #Description
20362220-HRange Finding Indicator
2081-022218-GWide Range
2212-GCresol Red
2109-012210-GBromthymol Blue
2110-012211-GPhenol Red
2111-012212-GCresol Red
2112-012213-GThymol Blue
2214-GOleo Red B
2124-012303-GAlkaline Wide Range
30366410-EFerroin
6411PS-HNitrite DRT
3037-DR-014483-EHardness 5
4257-HHardness Titration
6522-ECM Indicator
3043-DR-016413-EQAC Indicator
6412-HTitration Reagent
3095-026434-HHypochlorite Indicator
7941PS-HHypochlorite Reagent C
2301-GNitro Green Indicator
4483-EHardness Reagent 5
4485-EHardness Reagent 6
4487PS-HHardness Reagent 7
2246-EPhenolphthalein
2230-EMethyl Orange Indicator
6130PS-HHydrochloric Acid 1N
6323-HHydrochloric Acid 0.1N
6432-HSour Indicator
3110-01V-6278-HMixed Acid
V-6279-CNitrate Reducing
3114-02V-6282-GPhosphate Acid
V-6283-CPhosphate Reducing
3119-01V-6278-JMixed Acid
V-6279-CNitrate Reducing
V-6282-HPhosphate Acid
V-6283-CPhosphate Reducing
3121-02V-6282-GPhosphate Acid
V-6283-CPhosphate Reducing
3138-016364-CTetraphenylboron
7745-ESodium Hydroxide
3152-016155-ESodium Thiosulfate
6165-DXylenol Orange
6025-EHydrochloric Acid
6158PS-HThorium Nitrate
3160-016484-HMolybdenum Buffer
6485-HMolybdenum Oxidizing
6486-SMolybdenum Indicator
3176-026807-CDPD 1
6905-HDPD 3R
6815-GFerrous Ammon. Sulfate
6495-EControl Reagent
76
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
Page 77
Reagent Refills
Kit CodeReagent #Description
3304-013978LWT-HSalicylate Ammonia #1
3979WT-GSalicylate Ammonia #2
3982WT-GSalicylate Ammonia #3
3308-016999-HDPD 1R
6905-HDPD 3R
3312-016999-HDPD 1R
6905-HDPD 3R
3313-016999-HDPD 1R
6905-HDPD 3R
3314-016999-JDPD 1R
6905-JDPD 3R
3316-016905-6999DPD 1, DPD 3
6904-6906DPD 2, DPD 4
3328-016999-HDPD 1R
6905-HDPD 3R
3346-013962-HMolybdate 1 HR
3963-HMolybdate 2 HR
3347-014450-GIron Reagent 1
4451-SIron Reagent 2 Powder
4453-SFerrous Iron Reagent
3352-01V-6278-JMixed Acid Reagent
V-6281-CColor Developing Reagent
3354-012799-HNitrate 1
NN-3703-HNitrate 2
3363-016915-HPhenol Red
6905-6999DPD 1, DPD 3
3363-NJ-016915-HPhenol Red
6905-6999DPD 1, DPD 3
3366-016905-6999DPD 1, DPD 3
6915-3boxpH, Alk, Hard
3366-BR-016999-JDPD 1R
6915-3boxpH, Alk, Hard
3368-016905-6999DPD 1, DPD 3
3920-4boxpH, Alk, Hard, CYA
3456-01
3467-013870-EAlkalinity Indicator 1
3869-EAlkalinity Indicator 2
4493DR-HAlkalinity B
3468-014069-EChloride A
4070-HChloride B
3509-034483-EHardness Reagent 5
4484-JHardness Reagent 6 Tablets
4487WT-HHardness Reagent 7
4450-EIron Reagent 1
4451-SIron Reagent 2 Powder
2218Wide Range Indicator
3519-01V-6278-JMixed Acid
V-6279-CNitrate Reducing
V-6281-CColor Developing
Kit CodeReagent #Description
3541-016381-GHydrochloric Acid
4100-GO-Tolidine
5116WT-GFerric Iron Test
9078WT-GSour Indicator
3569-013943-HAluminum 1
3944-HAluminum 2
3582-013951-ELead A
3945-ELead C
3946-JLead Indicator
3588-024255-HHardness Buffer
3956-GManganese
6203-JChloroform
2785-EMetal Inhibitor
3609-014259-ESodium Hydroxide
T-5250-HCalcium Hardness
4487DR-HHardness 7
3615-01V-6278-KMixed Acid
V-6279-DNitrate Reducing
3619P-6367-ECopper A
P-6368-ECopper B
3622-016903-HDPD #1 Tablets
6811-EGlycine Solution
3624-016807-CDPD 1
6905-HDPD 3R
3992DR-HChlorine/Bromine
3628-017646-GMolybdenum Buffer
3632-013997-JMO Buffer
3998-HDenatured Alcohol
3999-HMO Titrant
4001-SCarbazone
3633-044797WT-GAmmonia Nitro. 1
4798WT-GAmmonia Nitro. 2
2218-GWide Range, pH 3
V-6278-HMixed Acid
V-6281-DColor Developing
2311-Eg-EBCG-MR Indicator
4493DR-HAlkalinity B
2246-EPhenolphthalein
4504-EChloride 1
4505DR-HChloride 2
6090-ESulfuric Acid
4483-EHardness 5
4485-EHardness 6
4487DR-HHardness 7
4169-HSodium Thiosulfate
4167-GMang. Sulfate
7166-GAlk. Pot. Iodide-Azide
6141WT-GSulfuric Acid
4170PS-GStarch Indicator
4253DR-HCarbon Dioxide B
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
77
Page 78
Kit CodeReagent #Description
3634-044797WT-GAmmonia Nitrogen 1
V-6278-HMixed Acid
Reagent Refills
3635-042218-GWide Range pH 3
3639-SC4004WT-GSodium Hydroxide
3640-SCT-3808-HCopper Tablets
3641-01-SC7865-CAluminum Inhibitor
3642-SCV-4797-GAmmonia Nitro. 1
3643-SC6903-JDPD 1
3644-SC6903-JDPD 1
3645-SCV-6276-DChromium Rgt.
3646-SC6446-ECopper 1
3647-02-SC3875-GAcid Zirconyl Spadns
V-6281-DColor Developing
2311-Eg-EBCG-MR Indicator
4493DR-HAlkalinity B
2246-EPhenolphthalein
4504-EChloride 1
4505DR-HChloride 2
6090-ESulfuric Acid
4483-EHardness 5
4485-EHardness 6
4487DR-HHardness 7
4253DR-HCarbon Dioxide B
4798WT-GAmmonia Nitro. 2
3978LWT-HSalicylate Ammon. 1
3979WT-GSalicylate Ammon. 2
3982WT-GSalicylate Ammon. 3
V-6278-JMixed Acid
V-6281-CColor Developing
V-6279-CNitrate Reducing
2311-Eg-EBCG-MR Indicator
4493DR-HAlkalinity Titration B
2246-EPhenolphthalein
4253DR-HCarbon Dioxide B
7460-ESalinity Indicator A
7461-HSalinity Titration B
4169-HSodium Thiosulfate
4167-GMang. Sulfate
7166-GAlkaline Pot. Iodide-Azide
6141WT-GSulfuric Acid
4170PS-GStarch Indicator
6364-CTetraphenylboron
7866-JAluminum Buffer
7867-JAluminum Indicator
7868-EAluminum Complex.
V-4798-GAmmonia Nitro. 2
6197-JDPD 3
6811-EGlycine
6811-EGlycine
4128-GSodium Arsenite
Kit CodeReagent #Description
3648-SCV-4450-GIron 1
V-4451-CIron 2
3649-SCV-6278-HMixed Acid
V-6279-CNitrate Reducing
3650-SCV-6278-HMixed Acid
V-6281-CColor Developing
3651-SC3989-GIndigo Blue Solution
3990-EChlorine Inhibitor
3991-KOzone Buffer
3653-SCV-6282-HPhosphate Acid
V-6283-CPhosphate Reducing
3654-02-SCV-4458-GSulfide A
V-4459-ESulfide B
4460-HSulfide C
3655-SC4410-HPhosphate Rgt.
3656-01-SC4842-DReagent B
4841-HHydrazine A
3658-01-SC3956-GManganese Indicator
4255-GHardness Buffer
6565-ESodium Cyanide
3659-01-SC3978-HSalicylate Ammon. 1
7457-DSalicylate 2
7458-CSalicylate 3
3660-01-SC6130-EHydrochloric Acid
4004-ESodium Hydroxide
2850PS-HCyanide Buffer
2794DS-CCyanide CL
2793DS-CCyanide Indicator
3661-01-SC4856-KCyanuric Acid Rgt.
3662-SC6452-GHydrogen Peroxide 1
6454Hydrogen Peroxide Tabs
3663-01-SC6251PS-HHydrochloric Acid
6253-KSodium Citrate
6254-HDimethylglyoxime
6537-HAmmonium Hydroxide
6566-GAmmonium Pers
6346WT-GSilver Nitrate
3664-SCV-4466-GSilica 1
V-4467-GSilica 2
V-4468-GSilica 3
V-6284-DSilica 4
3665-SCV-6277-DSulfate Rgt.
3666-01-SC7833-GTannin 1
7834-HTannin 2
3667-01-SC6314-GZinc Indicator
6315-GZinc Buffer
6565-ESodium Cyanide
6316-DSodium Ascorbate
5128-GFormaldehyde
6319-JMethyl Alcohol
78
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
Page 79
Reagent Refills
Kit CodeReagent #Description
3668-SC2776-EAcid Phenanthroline
2777-CIron Reducing
3669-SC6310-DManganese Buffer
6311-EManganese Periodate
3670-016903-JDPD 1
6197-JDPD 3
3670-LI-01P-6740-GDPD 1A
P-6741-GDPD 1B
P-6743-GDPD 3
3671-016903-JDPD 1
6811-EGlycine
3672-016903-JDPD 1
3673-016446-GCopper 1
3674-013875-JAcid Zirconyl SPADNS
4128-HSodium Arsenite
3676-016485-GMolybden. Oxidizing
3997-HMO Buffer
6486-SMolybdenum Indicator
3677-01V-6278-JMixed Acid
V-6279-DNitrate Reducing
3678-013989-GIndigo Blue Solution
3990-EChlorine Inhibitor
3991-KOzone Buffer
3679-01V-6282-HPhosphate Acid
V-6283-DPhosphate Reducing
3680-01V-4797-GAmmonia Nitrogen 1
V-4798-GAmmonia Nitrogen 2
3681-012776-EAcid Phenanthroline
2777-CIron Reducing
3682-014255-JHardness Buffer
3956-GManganese Indicator
6565-ESodium Cyanide
3683-01V-6277-DSulfate Rgt.
3687-SCV-4466-GSilica 1
V-4467-GSilica 2
4468-ESilica 3
3688-SC4167-GManganous Sulfate
7166-GAlkaline Pot. Iodide-Azide
6141WT-GSulfuric Acid
3698-SC7681-HSulfuric Acid
V-6276-DChromium Rgt.
7683-ESodium Azide
7682-GPotassium Permanganate
5115PT-HDeionized Water
3699-03-SC3997-GMO Buffer
6485-GMolybdenum Oxidizing
6486-SMolybdenum Indicator
3700-01-SCV-2209-HTRL Chlorphenol Red
V-2304-HTRL Phenol Red
V-2213-HTRL Thymol Blue
Kit CodeReagent #Description
4-3003-014450-GIron 1
4451-SIron 2
2218-GWide Range Indicator
4767-HSoap 4
4542-HPrecip A
4543-HPrecip B
4483WT-HHardness 5
4484-JHardness 6
4487WT-HHardness 7
4-8776-014133DSP Reagent 10%
4135Borate Buffer
4134PSSA Reagent 5%
4170Starch Indicator
6377Iodine Solution 0.025N
3843Zinc Acetate 2.0N
4031-014032Ammonia Chloride Buffer
6565Sodium Cyanide 10%
4033PAR Indicator
4022Stabilizing Reagent
4401-024410-GVM Phosphate
4408-016405-GReducing Rgt.
4410-HVM Phosphate
4430-014431-GChromate Indicator
4447-014450-GIron 1
4451-SIron 2
4456-014458-GSulfide A
4459-ESulfide B
4460-HSulfide C
4463-014571-GSilica 1
4467-ESilica 2
4468-ESilica 3
6405-CReducing Rgt.
4482-DR-LI-014483-EHardness 5
4485-EHardness 6
4487DR-HHardness 7
4482-DR-LT-014483-EHardness 5
4484-JHardness 6
4487DR-HHardness 7
4482-LI-024483-EHardness 5
4485-EHardness 6
4487WT-HHardness 7
4482-LT-024483-EHardness 5
4484-JHardness 6
4487WT-HHardness 7
4491-DR-01T-2311-HBCG-MR Indicator
4493DR-HAlkalinity Titration B
4497-014498WT-HChlorine 1
4499WT-HChlorine 2
4500PA-HChlorine 3
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
79
Page 80
Kit CodeReagent #Description
4497-DR-014498WT-HChlorine 1
4499WT-HChlorine 2
Reagent Refills
4501-014498-EChlorine 1
4503-DR-024504-EChloride 1
4507-024508-GDS Indicator
4515-017444-HDetergent Reagent 1
4533-01T-2246-JPhenolphthalein
4533-DR-01T-2246-JPhenolphthalein
46304633-HSulfide Test 1
4766
4783-034483-EHardness 5
4790-014791-EDEHA 1
4801-DR-014802DR-HTDS A
4824-DR-LT-014259-ESod. Hydroxide
4500DR-HChlorine 3
4499-EChlorine 2
3819-HSodium Thiosulfate
2246-EPhenolphthalein
6090-ESulfuric Acid
4505DR-GChloride 2
4509-HpH Adjustment
4513-EDS Reference
6037-JDetergent Reagent 2
7445-JDetergent Reagent 3
T-2311-JBCG-MR Indicator
4493PS-HAlkalinity Titration B
T-2311-JBCG-MR Indicator
4493DR-HAlkalinity Titration B
4634-HSulfide Test 2
4635-HSulfide Test 3
4636-HSulfide Test 4
4636-JSulfide Test 4
4637-SSulfide Test 5
4638-SSulfide Test 6
4639-HSulfide Test 7
4640-HSulfide Test 8
4484-JHardness 6
4487WT-HHardness 7
4450-GIron 1
4451-SIron 2
2218-GWide Range
4792-EDEHA 2
4793-EDEHA 3
4803DR-HTDS B
2299-EMethyl Orange
T-5250-HCalcium Hardness
4483-EHardness 5
4484-JHardness 6
4487DR-HHardness 7
Kit CodeReagent #Description
4824-LT-024483-EHardness 5
4484-JHardness 6
4487WT-HHardness 7
4259-ESod. Hydroxide
T-5250-HCalcium Hardness
5858-012218-GWide Range Indicator
5860-01
5864-013968A-HAmmonia #1 Tab
3969A-HAmmonia #2 Tab
5921-03
6616-016446-ECopper 1
6628-016630-DMolybdenum Rgt.
6381-GHydrochloric Acid
6701-016697-JFormaldehyde 1
6698-CFormaldehyde 2
6699-JFormaldehyde 3
6824-016811-EGlycine
6905-HDPD 3R
6977-JBromine Tablets
6896-016999-JDPD 1R
6915-HPhenol Red
6955-016977-HBromine Tablets
6980-016999DPD 1R
6904DPD 2R
6905DPD 3R
6899DPD 4R
6915Phenol Red
7001-NJ-01P-6740-HDPD 1A
P-6741-HDPD 1B
P-6743-HDPD 3
P-7026-HPhenol Red
6994-JCyanuric Acid
P-7028-GAlk 1 Indicator
P-6111-HAlk Titrant
P-4259-HHard 1
P-7030-GHard 2
P-7031-HCaHard Titrant
P-6068-EAcid Demand
P-6460-EBase Demand
76116117-GBarium Chloride 10%
80
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
Page 81
Reagent Refills
Kit CodeReagent #Description
7002-NJ-01P-6740-HDPD 1A
P-6741-HDPD 1B
P-6743-HDPD 3
P-7026-HPhenol Red
6994-JCyanuric Acid
P-7028-GAlk 1 Indicator
P-6111-HAlk Titrant
P-4259-HHard 1
P-7030-GHard 2
P-7031-HCaHard Titrant
P-6068-EAcid Demand
P-6460-EBase Demand
P-4450-EIron 1
T-4451-HIron 2
P-6446-ECopper 1
7011-016905-6999DPD 1, DPD 3
P-7026-GPhenol Red
7013P-6740-GDPD 1A
P-6741-GDPD 1B
P-6743-GDPD 3
P-7026-GPhenol Red
6994-HRBCyanuric Acid
P-6068-EAcid Demand
P-6460-EBase Demand
P-7028-GAlk 1 Indicator
P-6111-GAlk Titrant
P-4259-GHard 1
P-7030-GHard 2
P-7031-GCaHard Titrant
7014P-6740-HDPD 1A
P-6741-HDPD 1B
P-6743-HDPD 3
P-7026-HPhenol Red
P-6068-GAcid Demand
P-6460-GBase Demand
P-7028-GAlk 1 Indicator
P-6111-HAlk Titrant
P-4259-HHard 1
P-7030-GHard 2
P-7031-HCaHard Titrant
7056-017125-HPolyquat Titrating
2258-EPhenolphthalein
6090-ESulfuric Acid
3995-GToluidine Blue O
7117-HEDTA
7057-013996-HQuat Titrating
3995-GToluidine Blue O
7117-HEDTA
2258-EPhenolphthalein
6090-ESulfuric Acid
Kit CodeReagent #Description
7064-016289-HSulfuric Acid
6289WT-HSulfuric Acid
5168-JSodium Hydroxide
2246-EPhenolphthalein
7114-HGlut. Test Powder
5175PT-KDistilled Water
7068-014606-HPhosphate A
4607-JPhosphate B/C
7101-017102-GNitrite 1
7103PS-HNitrite 2
7101-DR-017102-GNitrite 1
7103DR-HNitrite 2
7105-037939PS-GHypochlorite A
2790-HHypochlorite D
6809-DPotassium Iodide
7132-012258-EPhenolphthalein
6385-DStarch Acid
2779WT-HIodide Iodate
7138-DB-016809-DPotassium Iodide
4170WT-GStarch Indicator
7139-HPeroxide Titrant
7140-HAcidified Catalyst
7143-012780-DT.C. Indicator
6025-HHydrochloric Acid
2781WT-HT.C. Titrant
7144-014483-GHardness 5
4485-EHardness 6
2782WT-HFree Chelant Titrant
7150-016809-DPotassium Iodide
4170WT-GStarch Indicator
7456WT-HPeroxide Titrant
7140-HAcidified Catalyst
7171-024483WT-GHardness 5
4485-GHardness 6
2783WT-HHardness 10
7172-026091WT-GHydrogen Peroxide
4069WT-GChloride A
6090WT-GSulfuric Acid
2258-EPhenolphthalein
3824WT-GSilver Nitrate
7175-017327-ESulfite A
7328-ESulfite B
7329PS-HSulfite C
7175-DR-017327-ESulfite A
7328-ESulfite B
7329DR-HSulfite C
7181-015649WT-GHydrochloric Acid
2258-EPhenolphthalein
6117-GBarium Chloride
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
81
Page 82
Kit CodeReagent #Description
7182-015648-GSodium Hydroxide
2258-EPhenolphthalein
7183-026410-EFerroin
Reagent Refills
7191-026141WT-GSulfuric Acid
7196-016434WT-GHypochlorite
7240-022258-EPhenolphthalein
7246-022788WT-GHardness 2
7247-016091WT-GHydrogen Peroxide
7250-022246-GPhenolphthalein
7253-017254-EIodine 1
7253-DR-017254-EIodine 1
7297-DR-012246-EPhenolphthalein
7340-R-017342-HPPK A
7387-026130-EHydrochloric Acid
7391-027393-GZinc Rgt.
2789WT-GCan Solution
6410-EFerroin
5650LWT-GHydrogen Peroxide
6521-GPotassium Iodide
S-6155-HPeracetic Acid Titrant
4500WT-HChlorine 3
6452-GHydrogen Peroxide 1
2786-ETotal Alkalinity
7748WT-GSulfuric Acid
4483WT-GHardness 5
4485-GHardness 6
4069WT-GChloride A
6090WT-GSulfuric Acid
2258-EPhenolphthalein
6421WT-HSilver Nitrate
4250-BJChlorine Test Papers
4483-GHardness 5
4485-GHardness 6
2783WT-HHardness 10
6323WT-HHydrochloric Acid
6130WT-HHydrochloric Acid
7255-EIodine 2
6406PS-HIodine 3
7255-EIodine 2
6406DR-HIodine 3
4253DR-HCarbon Dioxide B
7343-HPPK B
7344-HPPK C
4004-ESodium Hydroxide
2850PS-HCyanide Buffer
2794DS-CCyanide CL
2793DS-CCyanide Indicator
2955pH Test Paper
7361-EZinc Conditioning
Kit CodeReagent #Description
7416-024410-GVM Phosphate
6405-GReducing Rgt.
7417-027393-GZinc Rgt.
7361-EZinc Conditioning
7436-013870-EAlkalinity 1
3869-EAlkalinity 2
4493DR-HAlkalinity Titration B
4259-ESod. Hydroxide
T-5250-HCalcium Hardness
4487DR-HHardness 7
V-6282-HPhosphate Acid
V-6283-CPhosphate Reducing
2881-HpH 7.00 Buffer
74466446-GCopper 1
6899-JDPD 4R
7825-DAminoantipyrine
7826-HAmmonium Hydroxide
7827-JPot. Ferricyanide
7444-HDetergent 1
6037-JDetergent 2
7445-JDetergent 3
7459-027460-ESalinity A
7461DR-GSalinity B
7514-016807-CDPD 1
6905-HDPD 3R
3992WT-HChlorine/Bromine
7515-01T-2246-JPhenolphthalein
T-2311-JBCG-MR Indicator
6117-GBarium Chloride
6102PS-HAlkalinity Titrant
7516-DR-025115PT-HDeionized Water
6073-GBarium Chloride
2246-EPhenolphthalein
6251DR-GHydrochloric Acid
7519-017520-HStandard Turbidity
7530-DR-016130-EHydrochloric Acid
6155-ESodium Thiosulfate
6165-DXylenol Orange
6158PS-HThorium Nitrate
3929-EFluoride Inhibitor
7530-WT-016130-EHydrochloric Acid
6155-ESodium Thiosulfate
6165-DXylenol Orange
6158WT-HThorium Nitrate
3929-EFluoride Inhibitor
7625-016155-ESodium Thiosulfate
6323-EHydrochloric Acid
3964-EChrome Azurol S
3965-HThorium Nitrate
6130-EHydrochloric Acid
82
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
Page 83
Reagent Refills
Kit CodeReagent #Description
7625-DR-016155-ESodium Thiosulfate
6323-EHydrochloric Acid
3965-HThorium Nitrate
6130-EHydrochloric Acid
3964-EChrome Azurol S
7634-DC-016130-EHydrochloric Acid
6155-ESodium Thiosulfate
6158PS-HThorium Nitrate
2202-GMeta Cresol Purple
6165-DXylenol Orange
7634-DR-012202-GMeta Cresol Purple
6130-EHydrochloric Acid
6155-ESodium Thiosulfate
6165-DXylenol Orange
6158PS-HThorium Nitrate
7778-016456-HSulfate Turb
7787-014450-GIron 1
4451-SIron 2
7791-DR-022786-ETotal Alkalinity
6111DR-HSulfuric Acid
6248DR-HSodium Hydroxide
4483-EHardness 5
4484-JHardness 6
4487DR-HHardness 7
78026251PS-HHydrochloric Acid
6537-HAmmonium Hydroxide
6253-JSodium Citrate
6254-HDimethylglyoxime
6566-GAmmon. Persulfate
6346-GSilver Nitrate
5115PT-JDeionized Water
78247826-GAmmon. Hydroxide
7827-HPot. Ferricyanide
7825-CAminoantipyrine
7831-017833-ETannin 1
7834-HTannin 2
78847885-HSulfuric Acid
7886-JSodium Hydroxide
2246-EPhenolphthalein
6566-GAmmon. Persulfate
5115PT-JDeionized Water
7888-DBoiling Stones
7894-017939PS-GHypochlorite A
7940-GHypochlorite B
7941PS-HHypochlorite C
82058215-HAcid Titration
2786-ETotal Alkalinity
8225-018228-HTK-10 Rgt.
Kit CodeReagent #Description
8226-018230PA-HChl. Cleaner 1
8233PA-HChl. Cleaner 2
8234PA-HChl. Cleaner 3
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
83
Page 84
Beakers - BOD
Apparatus
Beakers
Glass beakers have thick, slightly flared top, with spout designed for excellent pouring. Designed from ASTM specifications E960, type I requirements. All sizes have marking area and white graduated volume scale.
Thomas® Polypropylene Beakers are polypropylene with superior chemical resistance. Ribbed for easy stacking. Meets ISO/DIS 7056 Standards
for Lab Plastic Accuracy. Autoclavable.
Glass Order CodePlastic Order CodeDescription
04100944Beaker, 50 mL
04150896Beaker, 100 mL
04142-2011Beaker, 150 mL
0596—Beaker, 200 mL
04110609Beaker, 250 mL
2-20242-2013Beaker, 400 mL
04122-2014Beaker, 600 mL
2-2027—Beaker, 1,000 mL
BOD Polyseed
Polybac Corporation Polyseed
For producing acclimated seed for fast, economical BOD5 analyses
with consistent results. Each capsule contains 100 mg for specialized,
lyophilized bacterial cultures. Contents of capsule are added to 500 mL
of APHA standard nutrient water at 20°C and stirred for 60 minutes.
Resultant mixtureprovides enough acclimated seed for up to 250 BOD
tests. EPA accepted.
Order CodeDescription
3-0002Polyseed®, Pk 50
®
84
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
Page 85
Bod - Cleaners
Apparatus
Flask/BOD Bottle Brush
Allows access to entire inside surface of flasks or BOD bottles. Black hog
bristle brush 4.25 inches. long mounted on a flat steel shank attached
to a pivoting shaft.
Order CodeDescription
1929-R35Brush, 16 inch, Pk 3
Imhoff Cone Brush
Conical shape with tufted bristle and sturdy twisted wire handle. Black
bristles combine with stiff fibers, shaped to fit into cone tip. Bristle part
9 in. long, 4 in. top diameter, 1.5 inch bottom diameter, tip 3 inch long,
length including handle 30 inch.
Burets
Twelve inch high, self-leveling, glass burets
are graduated from 0–10 mL in 0.1 mL
increments. Available with rubber squeeze
valve, glass stopcock, or Teflon® stopcock.
Buret-24 assembly includes empty 250
mL bottle of natural, low density polyethylene which attaches to 24 mm screwcap
on buret stem. Buret-28 assembly has
250 mL bottle of amber polyethylene and
28 mm cap. Bottle serves as titrant reservoir; a gentle squeeze forces titrant into
buret, where it automatically levels on 0
mL mark at top of scale.
Order Code
Buret Type
Rubber Squeeze0847-240847-280427
Glass Stopcock0827-240827-280826
Teflon Stopcock0996-240996-280997
With Poly
Bottle
Order Code
With Amber
Bottle
Order Code
Buret & Caps
Only
Order CodeDescription
1930-D10Brush, Imhoff cone
Cleaners
Alconox® Biodegradable
Cleaning Compound
Mild, odorless, non-toxic powdered wetting agent and detergent for cleaning
glassware, porcelain, metal, plastic, or
rubber. Suitable for use in ultrasonic
cleaners. Usual dilution 1 tablespoon to
1 gallon water.
Order CodeDescription
2902-G05Alconox, 4 lb Box
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
Single-ply premium lab wiper for extra low-lint performance. Won’t scratch delicate surfaces. LINTGUARD® polyshield reduces lint and electrostatic
discharge when dispensing. Gently absorbent for
light liquid pickup.
Order CodeDescription
2-20694.5 x 8.5 single-ply in dispensing box, Box 280
Coliform
Thomas® Coliform Water Sample Bag
Twist tie top seals with a 5
mm wide metal strip. Large
textured label area. Meets
EPA requirements for microbiological samples for
potable water according to
Standard Methods (Method 9060 A) or for NPDES
compliance monitoring.
Sterilized, with thiosul
fate dechlorination tablet
included. 100 mL fill line
marked for easy reference.
Order CodeDescription
1303-R90Sample Bag, 100/bag
-
COD Heater
120V and 230V, 12-tube capacity. This COD heater block features digital
microprocessor control, programmable time and temperature settings,
and a dual LED display to monitor both temperature and timer. Perfect
for COD, Total Phosphorus, and Total Nitrogen testing PLUS other tests
requiring digestion. See page 14 for additional specifications.
Order CodeDescription
5-0102COD Heater Block, 120 V
5-0102-EX2COD Heater Block, 230 V
Thomas® Coliform Water Sampling Vial
Improved sample container for microbiological testing. Ideal when filtration or the Colilert® method is used. Improved latching mechanism, won’t
open or leak in transit. Pre-sterilized, with thiosulfate tablet included.
120 mL fill line.
Order CodeDescription
9853-Q41Vial with tablet, Bg 100
86
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
Page 87
Cylinders - Flasks
Apparatus
Cylinders
Glass cylinders have pouring spout and
permanent fused white graduations.
Plastic cylinders meet ASTM Class B,
E1272 standards and have excellent
heat and chemical resistance.
PlasticVolume (Ml)
2-2076100.20416
2-2077250.50417
2-2078501.00418
2-20791001.00419
2-20802502.0—
2-20815005.0—
2-20821,00010.0—
Graduation
Intervals (Ml)
Glass
Order Code
Filter Paper
All papers listed are sold 100 to a package.
Order CodeDescription
Alhstrom
0463No. 642-27, Qual.11Slow
0465No. 642, Qual.9Medium
Diameter
(Cm)Speed
Filter/Syringe Assembly
For on-site collection of filtrates or filtered material from natural or
industrial waters. Consists of 60 mL plastic syringe, dual check-valve,
Delrin® filter holder with Luer slip outlet and clear flexible PVC tubing, 3
ft. long x 0.625 inch i.d. Tubing attaches to check-valve outlet. Syringe
is calibrated to 0 to 60 mL and 0 to 2 oz.
Order Code Description
1050Complete filter/syringe
assembly
0943Syringe, 60 mL
1175Tubing, 36 in.
1174Check-valve
0598Filter Holder
Code 0598 holder acccepts the
following filters (furnished in
packages of 100, unless otherwise
specified):
0947Paper, 2.5 cm
1157Glass Fiber, 24 mm
Membrane, 25 mm
11030.45 micron, pkg. 100
Whatman
0947No. 2, Qual.2.5Medium
0471No. 2, Qual.9Medium
2-2098No. 42, Ashless, Quan.9Slow
2-2100No. 42, Ashless, Quan.12.5Slow
1157Glass Fiber2.4—
Whatman® Quantitative
Ashless Filter Papers
Suitable for precipitates that are ordinarily
difficult to filter (2.5 mm particle retension).
Acid Wash, Ash Content 0.007%. Highly retentive for very fine analytical precipitates.
Recommended for use with vacuum.
Order CodeDescription
2-2098Filter Paper, 9 cm, Pk 100
4716-Q25Filter Paper, 11 cm, Pk 100
2-2100Filter Paper, 12.5 cm, Pk 100
Flasks
Nalge® Erlenmeyer
Flasks
Glass flasks have thick-walled
body with tapered contour to
minimize chipping. Approximate volumes are indicated.
Plastic flasks are polycarbonate with polypropylene screw
closures; use for preparation
and storage of culture media
and culturing techniques.
Plastic Order CodeDescriptionGlass Order Code
2-2116Flask, 125 mL0431
2-2117Flask, 250 mL0433
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
87
Page 88
Flasks - Hydrometers
Apparatus
Flasks, Corning
Volumetric
Pyrex® Brand Class A. Heavy beaded,
heavy tubing neck with snap cap.
White block letters for easy readability.
Order CodeDescription
2-2127Flask, Volumetric, 50 mL
2-2128Flask, Volumetric, 100 mL
2-2129Flask, Volumetric, 500 mL
Hydrometers
Specific Gravity 1 to 1.6
For liquids heavier than water. Approximate total length 305 mm, approximate length of graduate scale 135 mm, viewing range has scale
approximately 150 mm long, and is made without conventional enlarged
bulb at bottom. Tolerance ±1 scale division. Requires a cylinder 340x38
mm and approximately 250 mL of liquid.
Order CodeDescription
2-2150Hydrometer, 1.000-1.220: 0.002 interval
2-2151Hydrometer, 1.200-1.420: 0.002 interval
2-2155Hydrometer, 1.000-1.600: 0.005 interval
Corning Pyrex® Brand
Hydrometer Cylinder
Heavy wall construction. Large, hexagonal
base, sealed to the cylinder body, increases
stability.
Order CodeDescription
2-2149Hydrometer Cylinder,
38 x 340 mm
Funnels, Plastic
Reinforced rim. Ridges outside and inside permit air passage and improve filtering efficiency. Withstand continuous use at temperatures
up to 130°C.
Order CodeDescription
2-2134Funnel, 9 mL
2-2135Funnel, 20 mL
0459Funnel, 37 mL
2-2137Funnel, 95 mL
88
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
Page 89
Pipets - Stirrers & Accessories
Apparatus
Magnifier
MacroLens
MacroLens with 5X magnification covers the entire
petri dish. 4 inch diameter.
Order CodeDescription
5508MacroLens
5508-10MacroLens 10 Pack
Pipets: Corning
Transfer Pipets
Pyrex® Class A. Tapered at both
ends. Calibrated to deliver rated
volume at 20°C.
Order CodeDescription
2-2170Transfer Pipet, 1 mL
2-2174Transfer Pipet, 5 mL
2-2175Transfer Pipet, 10 mL
Pipets: Bel-Art® Safety Bulb
Tapered silicone seal provides airtight fit in all pipet sizes. 2-2164 comes
complete with an elastic cord for dedicating pipettor to a specific reagent bottle.
Order CodeDescription
2-2164Safety Bulb
0395Safety Bulb
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
Stirring Bars
Octagon-shaped with rounded ends and molded pivot ring.
Magnetic Stirring Bar Retriever
For insertion or removal of magnetic stirring bars. Overall length 11.5
inches.
Order CodeDescription
2-2185Stirring Bar, .3125 x 1 inch
2-2186Stirring Bar, .3125 x 1.625 inch
2-2187Magnetic Pick Up Rod
89
Page 90
Stirrers & Accessories - Thermometers
Apparatus
Stopcock Grease
Lubriseal® Stopcock Grease
For lubricating ground glass joints, glass, and metal stopcocks and
valves, and for sealing desiccators, anaerobic culture jars, and similar
utensils. Prevents the freezing of stopcocks, ground joints, etc. Low vapor
pressure, and resists attack by acidic and alkaline solutions. Smooth
textured, stable, free from vegetable or animal oil or silicone, and practically insoluble in water.
Order CodeDescription
2-2158-HLubriseal, 75g tube
Thermometer, Armored
A precision, NON-MERCURY thermometer encased
in a protective, plastic jacket. Window opening
views engraved graduation on white tubing which
increases readability. Full range of -5° to 45° in
0.5° increments.
Order CodeFull Range
1066-5° to 45°C in 0.5 ° increments
Thermometer, Thomas®
Switchable, °C/°F
8 in. thermometer with a wide range and
digital display. Fits into cuvettes, test
tubes, flasks, and beakers. Stainless steel
probe is resistant to acids, bases, solvents,
and most laboratory chemicals. Dual range
of -58° to 302°F or -50° to 150°C. Digital resolution of 0.1° from -20° to 200°.
Accuracy is ±1°C between -20° to 100°C.
Readings updated every second. Operates
continuously for over a year on a single replaceable silver-oxide battery (included).
Supplied with protective case that can be
used as a holder.
90
Order CodeDescription
9329-H01Switchable Thermometer with Digital Display
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
Page 91
Aquaculture Testing Products
Code 1612
Test kits and instrumentation for critical water quality control of
aquarium systems. Designed for the hobbyist, retailer, and ornamen-
tal fish culturist. Test kits, instrumentation, and combination outfits
designed for fish farms, hatcheries, and research institutions. Equip-
ment designed for monitoring water quality conditions on-site and
at benchtop locations.
Science Education Products
Code 1590
Practical, “hands-on” test equipment for air, soil and water chemistry
students in elementary, secondary, vocational, outdoor and college
science programs.
Pool & Spa Water Test Equipment
Catalogs
Code 1634
A complete line of test kits, combination outfits and labs for pool pro-
fessionals, public pool or spa operators, and private pool or spa owners.
Product Price List
Code 1645
This “component price list” gives price and ordering information on
all standard LaMotte reagents, labware, apparatus and accessories.
Reagents are listed in kit-size and bulk containers.
Soil Testing Products
Code 1652
Field and laboratory test equipment for measurement of soil nutrients
and soil pH. For agricultural soils, greenhouses, gardens, dairy sanita-
tion, aquaculture and hydroculture.
Water Conditioning Testing Products
Code 1650
Softener sales demonstration outfits and other specialized test equip-
ment for the point-of-use water treatment industry.
Food & Beverage Safety Testing Products
Code 1658
A comprehensive collection of test kits, test strips, and instruments
for use in Industrial and Food/Beverage applications.
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
91
Page 92
A Study of Water Quality
Dr. Charles E. Renn;
Handbooks
46 pages
Examines the “life cycle” of water
from its occurrence in nature to its
treatment for domestic and industrial use, with emphasis on such
water quality problems as scaling,
corrosiveness, taste, and turbidity.
Order Code 1532
A Laboratory Manual for
Marine Science Studies
Staff, LaMotte Company;
32 pages
Test procedures and background
information on sampling and analysis in salt water environments oceans, bays, marine estuaries, and
salt marshes.
Order Code 1587
Chemistry & Control of
Modern Chlorination
Dr. A.T. Palin; 64 pages
The process of chlorination and
principal methods of chlorine testing. Written by a leading international authority on chlorine measurement.
Order Code 1597
Investigating Water
Problems
Dr. Charles E. Renn;
72 pages
Discusses 25 chemical factors of
water quality analytical procedures
for their measurement and interpretation of test results.
Order Code 1589
Limnology: An
Introduction to the Fresh
Water Environment
William A. Amos;
40 pages
Discusses biological, chemical,
and physical processes in ponds,
lakes, swamps, streams, and rivers
- stream dynamics, plant zonation,
the succession of ponds, the energy
cycle of ponds, etc.
Order Code 1593
Marine Aquarium
Handbook
Staff, LaMotte Co.; 20 pages
Test procedures and background
information on chemical testing
for successful management of
aquarium water.
Order Code 1585
Monitor’s Handbook
Staff, LaMotte Co.; 71 pages
A complete guide covering the importance of water quality of all types
of natural waters. Gives guidance for
watershed surveys, site location,
sample collection, and choosing appropriate methods and equipment.
Describes physical, chemical, and
biological factors of water quality,
and the analytical procedures for
their measurement. Provides the
basic program planning, data analysis, and reporting with conversion
factors, glossary, and resource list.
For individuals or groups starting a
water quality monitoring program.
Order Code 1507
Our Environment
Battles Water Pollution
Dr. Charles E. Renn;
32 pages
Traces a theoretical river from its
origin as a mountain brook to its
discharge into a marine estuary, examining the chemical and biological
changes that occur as the stream
reacts to impurities from natural
and industrial sources.
Order Code 1592
Pool Mgr. Handbook
Staff, LaMotte Company;
60 pages
A 60 page text for entry level lifeguards or aquatic supervisors. Discussions on water balance, sanitation, analysis, and problem solving.
Water treatment charts are provided.
Order Code 1505
A Study of Soil Science
Dr. Henry D. Foth;
44 pages
An introduction to soil formation,
soil pH, mineral elements and plant
nutrition, the life cycle of growing
plants, and soil fertility management.
Order Code 1530
The LaMotte Soil
Handbook
Staff, LaMotte Company;
60 pages
This “growers manual” discusses
major and minor nutrients, trace
elements, soil pH, organic matter,
soil texture, etc. Includes lime and
fertilizer recommendations for a
variety of crops and plants.
Order Code 1504
Plant Nutrition Studies
Dr. Robert Stegner;
76 pages
Discusses the study and practice
of hydroponics - plant culture in
soilless solutions - and includes a
series of laboratory investigations.
Order Code 1596
92
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
Page 93
LaMotte has available a large variety of standards to be used in many applications.
Standards
Primary
StandardsConcentration
Ammonia
Nitrogen
Chlorine250 ppm6973-H606 mo.
Chlorine250 ppm6973-L4756 mo.
Chlorine
Equivalent
COD
Equivalent
Color500 cu6058-H603 yrs.
Color500 cu6058-L5003 yrs.
Conductivity/
TDS
Conductivity/
TDS
Conductivity/
TDS
Conductivity/
TDS
Conductivity/
TDS
Conductivity/
TDS
Conductivity/
TDS
Conductivity/
TDS
Conductivity/
TDS
Conductivity/
TDS
Conductivity/
TDS
Conductivity/
TDS
Conductivity/
TDS
Copper100 ppm6181-L4752 yrs.
Fluoride1000 ppm4154-H601 yr.
Fluoride1000 ppm4154-L5001 yr.
Fluoride1 ppm2798-M10002 yrs.
Hard Water120 ppm5617-L5003 yrs.
Ferric Iron200 ppm3860-H601.5 yrs.
Magnesium1000 ppm6190-H601 yr.
Nickel1000 ppm6196-H602 yrs.
Nitrate
Nitrogen
pH2.02856-L5001.5 yrs.
100 ppm3871-H602 yrs.
1000 ppm3858-H606 mo.
500 ppm7589-L4752 yrs.
84 µS/59 ppm6312-L5001.5 yrs.
718 µS/
503 ppm
718 µS/
503 ppm
718 µS/
503 ppm
1413 µS/
989 ppm
1413 µS/
989 ppm
1413 µS/
989 ppm
6668 µS/
4668 ppm
6668 µS/
4668 ppm
12880 µS/
9016 ppm
12880 µS/
9016 ppm
12880 µS/
9016 ppm
58640 µS/
41048 ppm
1000 ppm5392-H602 yrs.
Order
Code
6417-J1201.5 yrs.
6417-L5001.5 yrs.
6417-N38001.5 yrs.
6354-J1201.5 yrs.
6354-L5001.5 yrs.
6354-N38001.5 yrs.
6418-J1001.5 yrs.
6418-L5001.5 yrs.
6317-G301.5 yrs.
6317-J1201.5 yrs.
6317-L5001.5 yrs.
6419-L5001.5 yrs.
Quantity
(mL)Shelf Life
Primary
StandardsConcentration
pH Buffer
Tablets
pH Buffer
Tablets
pH4.012866-J1201.5 yrs.
pH4.012866-L5001.5 yrs.
pH4.012866-N38001.5 yrs.
pH Color
Coded Red
pH6.02876-L5001.5 yrs.
pH6.862808-L5001.5 yrs.
pH Buffer
Tablets
pH Buffer
Tablets
pH7.002881-H601.5 yrs.
pH7.002881-J1201.5 yrs.
pH7.002881-L5001.5 yrs.
pH7.002881-N38001.5 yrs.
pH Color
Coded Yellow
pH8.02886-L5001.5 yrs.
pH9.02891-L5001.5 yrs.
pH9.182809-L5001.5 yrs.
pH Buffer
Tablets
pH Buffer
Tablets
pH10.02896-J1201.5 yrs.
pH10.02896-L5001.5 yrs.
pH Color
Coded Blue
pH11.02897-L5001.5 yrs.
pH12.02898-L5001.5 yrs.
Phosphate
PO
4
Phosphate
PO
4
Phosphate
PO
4
Phosphorus
(Total)
Phosphorus
(Total)
Potassium1000 ppm6187-L4752 yrs.
Sulfate2000 ppm7120-H602 yrs.
4.03983A-H50 Tabs3 yrs.
4.03983A-J100 Tabs 3 yrs.
4.013771-L5001.5 yrs.
7.03984A-H 50 Tabs3 yrs.
7.03984A-J100 Tabs 3 yrs.
7.003772-L5001.5 yrs.
10.03985A-H50 Tabs3 yrs.
10.03985A-J100 Tabs3 yrs.
10.03773-L5001.5 yrs.
1000 ppm6184-L4751 yr.
3080 ppm5393-H602 yrs.
3080 ppm5393-L4752 yrs.
1000 ppm 5393-H602 yrs.
1000 ppm5393-L4752 yrs.
Order
Code
Quantity
(mL)Shelf Life
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
continued next page...
93
Page 94
Standards
Primary
StandardsConcentration
Turbidity
2020we
Turbidity
2020we
Turbidity
2020we
Turbidity
2020we
Turbidity
2020wi
Turbidity
2020wi
Turbidity
2020wi
Turbidity
2020wi
Turbidity
2020e
Turbidity
2020e
Turbidity
2020e
Turbidity
2020e
Turbidity
2020i
Turbidity
2020i
Turbidity
2020i
Turbidity
2020i
Turbidity
2020
Turbidity
2020
Turbidity
2020
Turbidity
Formazin
Zinc100 ppm5394-L4752 yrs.
0 NTU1480601 yr.
1 NTU1450601 yr.
10 NTU1451601 yr.
100 NTU1452601 yr.
0 NTU1480601 yr.
1 NTU1453601 yr.
10 NTU1454601 yr.
100 NTU1455601 yr.
0 NTU1480601 yr.
1 NTU1484601 yr.
10 NTU1485601 yr.
100 NTU1486601 yr.
0 NTU1480601 yr.
1 NTU1481601 yr.
10 NTU1482601 yr.
100 NTU1483601 yr.
1 NTU1476601 yr.
10 NTU1477601 yr.
100 NTU1478601 yr.
4000 NTU6195-H601 yr.
Order
Code
Quantity
(mL)Shelf Life
Secondary
Standards
Chlorine DPD0, 0.2, 1.0,
Smartcheck Various
ConcentrationOrder
2.5 ppm
Absorbance
Units
Code
4140-02
4141-01
94
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
Page 99
How To Order
Order Form
By Mail: LaMotte Company
PO Box 329
Chestertown, Maryland 21620 USA
Bill To
Name
Title
Company
Department
City
State/Zip
Phone
Account #
Special Instructions:
By Phone: 800 344 3100
410 778 3100
By Fax: 410 778 6394
Website: www.lamotte.com
Ship To
Name
Title
Company
Department
City
State/Zip
Phone
Ship Via.
Payment Method
Payment Terms are net 30 days to accounts with established credit. New accounts should provide credit references or enclose payment with order. MasterCard, VISA, and American Express are also accepted.
Check Purchase Order MasterCard VISA American Express
Credit Card Account #
Expiration Date
Purchase Order #
Name as it appears on card
Order
Please include the product code number for each item ordered to insure that your order is speedily and correctly processed.
Prices are f.o.b., Chestertown, Maryland. Prices are subject to change without prior notice. A $7.50 handling fee and a $7.50
shipping fee are applied to all orders totaling less than $35.00. On orders to which a handling fee is not applicable, freight
charges will be added at cost to invoice total.
QuantityCodeModel/DescriptionUnit PriceExtension
Net Total
$15.00 Shipping and Handling Fee (If Net Total is Less Than $35.00)
Sales Tax, If Applicable (Maryland Only)
Invoice Total
Page 100
PHONE1-800-344-3100
(001) 1-410-778-3100
FAX(001) 1-410-778-6394
INTERNETwww.lamotte.com
lamotte.com/contact_us.html
MAILPO Box 329
802 Washington Avenue
Chestertown, Maryland 21620 USA
EASY PAYMENT Order with a purchase order or use VISA,
American Express, MasterCard or enclose
payment with purchase order if you don’t have
an account. To open a new account, please
provide credit references.
COURTEOUS SERVICE and an interest in every customer’s
satisfaction have given LaMotte Company a reputation of
distinction in the chemical testing field. Please give us the
opportunity to meet your chemical testing requirements today.
Loading...