Complete List of Standards ............................................................. Pages 93-94
analysis of water and soil.
INDEX
Acidity to Zinc .......................................................................................... Pages 95-98
LaMotte Company manufactures its products at its 65,000 square foot facility in Chestertown, Maryland, near
Washington, DC on the east coast of the United States.
Capabilities
Over 10 years into our Lean Man-
ufacturing journey, LaMotte’s
chemists, engineers, and techni-
cians continue to optimize a wide
variety of processes to achieve
maximum quality and efficiency.
We offer a wide range of test
methods and tools for the ana-
lyst, from multi-factor test strips,
foil-packaged unit dose tablets,
unit dose powder vials, and liquid
reagents to sonic-welded color
comparators, multi-
parameter test
kits, and electron-
ic instruments.
LaMotte controls
the manufacturing
of all aspects to
ensure the high-
est quality.
4
We believe strongly in having a team of technical experts available by phone and email for customer support. The Research and Devel-
opment team works to constantly improve and create new test methods. Our in-house graphic design department provides extensive
services that are especially valuable for the many custom designed products that LaMotte welcomes.
All of these varied capabilities enable LaMotte to excel at helping people solve their analytical challenges.
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
If your needs go beyond our standard
product line, then our Custom Test
Kit Services Department can design a
custom kit to meet your needs.
WE CAN design a kit that combines any
grouping of parameters you need.
WE CAN develop new test methods for new
proprietary compounds or for control of
specialized treatment programs
Custom | Int’l Sales
Custom Test Kit Services
WE CAN alter existing graphics and
packaging or design something new for
private labeling purposes
Available online at www.lamotte.com:
Entire Product Listing with Full Descriptions Printable Test Instructions Printable MSDSs Printable Reagents Certificates of Analysis
How The Custom Test Kit Service Works
1. Contact our Customer Service or International Sales departments by phone,
fax, or email. Tell us how you plan to use the product, the level of accuracy
and range you need, how many kits, and any limitations such as size, weight,
cost, or skill level of the end user (i.e. student, consumer, technician).
2. We will prepare a quote for you. Based on the information you provide, we will
suggest one of our non-catalog test kits or develop a kit to suit your needs.
3. Once you order, we immediately begin the development process, subject to
final approval before beginning production.
International Sales
Worldwide Distributor Network
For Pricing and To Order, contact a distributor near you.
To locate a LaMotte distributor, visit www.lamotte.com and
select “INTERNATIONAL”. For more information email us
at intl@lamotte.com.
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
5
Colorimetric
See
Methods
Videos
Colorimetric
There are two basic types of colorimetric tests:
Test Methods
1. Tests which determine the concentration of a substance are based on Beer’s Law. Simply stated, this says that the higher the concentration of a
substance, the darker the color developed in the test, so more light is absorbed by the sample.
2. pH tests use an indicator which changes color with changes in the concentration of hydrogen ions, or the acidity of the solution.
Octa-Slide 2
Comparator
The Octa-Slide 2 replaces
the Octet and Octa-Slide
comparators. All 8 color
standards can be viewed
at once against a precision matched color bar
top-loaded next to the
sample tube. This com
parator system can be
used with existing re
agent system but is not
compatible with color
bars from the original
Octa-Slide.
-
-
IN OPERATION!
LRC Comparator
This innovative design replaces
the Axial Reader with a simpler
and significantly improved optical system. Simply place one
reacted sample in the front
and one un-reacted sample
behind it and let the light shine
down into both tubes. Precision
matched glass ampoules are in
the slide bar so even the most
sensitive low range colors can be
matched one-on-one with extraordinary ease and confidence.
6
Test Strips
Test strips are either dipped
or swirled in test solutions.
The resulting color reaction
is compared to a color chart
provided.
Color Chart Comparator
Color charts are laminated color
standards. The reacted sample
is held against the panel and
compared to the color standards.
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
Electronic • Titrimetric
Electronic Methods
Electronic colorimeters measure the amount of light which travels through the reacted sample, and convert the measurement
to a reading as ppm, absorbance or %T. In addition to colorimeters, LaMotte offers instruments to test pH, TDS/conductivity,
dissolved oxygen, and turbidity.
Test Methods
Titrimetric
Titrimetric tests can be used to determine the concentration of a substance in a sample solution. After the sample is treated with an indicator, a standard titrant is added until a color change indicates a completed reaction. LaMotte offers four separate types of titration methods, allowing a choice of
precision and convenience.
Automatic Buret
Direct Reading Titrator
The Direct Reading Titrator is a 1.0 mL
microburet calibrated to allow direct
reading of the test result. Each Titrator
has a specific range, but may be refilled
to test higher concentrations.
Dropper Pipet
The drop count test uses a pipet to
provide fast, reliable measurements in
the field. The number of drops used to
obtain a color change is multiplied by a
given factor to produce the test result.
Dropper Bottle
The dropper bottle test uses bottle tips which deliver
a consistent standard drop size to add titrant to the
sample. As with the drop count test, the number of
drops used to complete the reaction is multiplied by a
given equivalence factor to determine the concentration. Many dropper bottle tests use different sample
sizes for different equivalences.
The self-zeroing automatic
buret is calibrated from 0 to
10 mL in 0.1 mL increments.
It is available with a squeeze
valve (pinchcock), glass stopcock, or Teflon® stopcock.
See page 85 for full line of automatic burets.
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
7
SMART3 Colorimeter
Replaceable cup
protects optics
Instrumentation
6-button keypad
Over 80 Pre-Programmed Tests
New Bolder
Backlit Display
Simple
Code 1910
The user-friendly SMART3 Colorimeter is the ideal direct reading colorimeter for complete on-site water analyses.
All pre-programmed tests can be run on these compact instruments and
each test features automatic wavelength selection. The entire multi-LED
optical system is embedded in the light chamber and optimized for LaMotte
test reagent systems. The analyst can simply select the test and put in the
sample with reagent. The microprocessor, which selects the wavelength,
also allows the user to load up to 25 tests for analyzing custom reagent
systems. LaMotte stands behind every system we provide.
These portable colorimeters have the user in mind with these advanced
features:
IP67 Waterproof Simple, menu-driven operation Alphabetical test selection User-selected test sequences Self diagnostics with error/warning messages Instant readiness without “count down” delays; achieved by active
stabilization of lamp intensity
Auto-blank; Auto-off European CE mark
The user may select any of the wavelengths in each meter to
determine the absorbance or %T of a sample at the desired
wavelength.
Additional advancements include:
Superior narrow band-width interference filters New LCD display for improved readability USB interface Optional software for data storage and manipulation Lithium ion rechargeable battery, USB computer adapter is
included
As well as the incorporated features:
All wavelength filters - 428, 525, 568, 635 nm (SMART3 only) USB port and more...
* SMART 3 Turbidity is not the same as EPA 180.1 Turbidity
SMART Colorimeter® is a registered trademark of LaMotte Company.
8
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
SMART3 Colorimeter & SMARTLink 3
See pages 17-18 for
complete reagent
system listing.
Instrumentation
Range:0-125%T
Resolution:1% FS
Accuracy:2% FS
CE Mark:Yes
Display:160x100 Backlight LCD, 20x4 line graphics display
Sample Cell:25 mm round cell, 10 mm square cuvette, 16 mm COD tubes
Datalogging:Up to 500 data points, USB transfer, time and date stamped
Keypad:6-button mechanical
Calibration:Factory set - user adjustable
Power:USB computer/power charger or Lithium Ion rechargeable battery,
3.7V, 2.5” x 0.75”, 1.7 oz.
Dimensions:19.05 x 8.84 x 6.35 cm; 7.5 x 3.5 x 2.5 inches
Weight:15 ounces
Bandwidth:10 mm typical
SMART3 • Code 1910
Comes with 6 sample tubes, power charger and manual
Chamber Cup
COD/UDV adapter Code 1724
6 sample tubes Code 0290-6
USB Cable Code 1720
USB Power Plug Code 1721
Car Charger Code 5-0132
Small Case Code 1910-GCS150
Large Case Code 1910-GCS440
SMARTLink 3 Program
Order Code 1901-CD
Interface the SMART3, 2020w and LTC-3000w meters with a Windows-based personal computer. The program
can be used to download data stored in the dataloggers of these meters. The program allows the user to identify, organize, view, manipulate and store data as a database on a PC. Data can also be copied and pasted or
exported to other applications as a CSV file.
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
9
2020w Portable Turbidity Meters
1
1
Instrumentation
Industry-leading precision, sensitivity, and dependability in one of the most
innovative WATERPROOF, handheld meters available on the market!
EPA
80.
The multi-detector optical configuration assures long term stability and minimizes stray light and
color interferences. All readings are determined by the process of signal averaging over a 5 second
period. This minimizes fluctuations in readings attributed to large particles and results in rapid, highly
repeatable measurements. Ideally suited for both low-level drinking water applications as well as
monitoring high turbidity in the field.
Seven user selected languages – English, Spanish, French, Japanese, Chinese, Italian,
and Portuguese
Advanced calibration algorithms Best for low range turbidity analysis Easy menu driven operation and large LCD display
Waterproof to IP67
Lithium rechargeable batteries
500 point data log; stored results can be viewed directly on instrument or downloaded to a
computer via USB cable and SmartLink 3 software (available separately)
10
USB port
7 languages
Backlit display
EPA and ISO versions
2020we version meets US EPA design criteria as specified by EPA 180.1, Rev. 2.0 (1993) and
Standard Methods 2130 B-2001.
2020wi version meets design criteria for quantitative methods of turbidity using optical turbidimeters as specified by ISO 7027. Best for colored or extremely turbid samples.
Kits are supplied with 0, 1, and 10 NTU standard, sample bottle, four sample tubes, USB cable
and wall adapter.
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
2020w Portable Turbidity Meter
Instrumentation
To Order:
2020we Kit • Portable turbidity meter complies with by EPA 180.1, Rev. 2.0 (1993) and
Standard Methods 2130 B-2001
Order Code 1970-EPA
2020wi Kit • Portable turbidity meter complies with ISO 7027 Standard
Order Code 1970-ISO
Accessories:
0 NTU/FNU Standard (EPA and ISO),
60 mL; Code 1480
1 NTU/FNU Standard (EPA and ISO),
60 mL; Code 1453
10 NTU/FNU Standard (EPA and ISO),
60 mL; Code 1454
100 NTU Standard (ISO), 60 mL;
Code 1455
1 NTU Standard (EPA), 60 mL;
Code 1450
10 NTU Standard (EPA), 60 mL;
Code 1451
100 NTU Standard (EPA), 60 mL;
Code 1452
Formazin Standard Solution,
4000 NTU, 60 mL; Code 6195-H
USB Cable, Code 1720 Wall Adapter, Code 1721 SMARTLink 3 Software; Code 1901-CD Six-pack of vials; Code 0290-6 Car Charger; Code 5-0132 Chamber Cup; Code 3-0038
Kits are supplied with 0, 1, and 10 NTU/FNU standards, sample bottle, six sample tubes, USB cable
and wall adapter—all in a sturdy carrying case.
Turbidity Specifications:
Unit of Measure
2020we
Units of Measure
2020wi
Range*0-4000 NTU/FNU, 0-10,500 ASBC, 0-150
Resolution*0.01 NTU/FNU 0.00-10.99
Accuracy*From 0-2.5 NTU the accuracy is ±0.05 NTU.
Detection
Limit
Range
Selection
Reproducibility*0.02 NTU/FNU or 1%
Light SourceTungsten (EPA), complies with EPA 180.1,
NTU, AU, ASBC, EBC
FNU, FAU, ASBC, EBC
EBC
0.1 NTU/FNU 11.0-109.9
1 NTU/FNU 110-4000
From 2.5-100 NTU the accuracy is ±2%.
Above 100 NTU the accuracy is ±3%.
0.05 NTU/FNU
Automatic
Rev. 2.0 (1993) and Standard Methods 2130
B-2001; 860nm LED (ISO), complies with ISO
7027
Meter Features:
Signal AveragingDisabled, 2, 5, 10
PowerUSB computer cable, wall adapter or Lithium ion
AC PowerOptional
Data Logging500 points
Auto Shut-OffDisabled, 5, 10, 30 seconds
Response Time<2 Seconds
Size7.5 x 3.5 x 2.5 inches; 19.05 x 8.84 x 6.35 cm
Weight13 ounces
Display6-line LCD with backlit display
*Over 600 NTU/FNU units expressed as AU/FAU
rechargeable battery, 3.7V, 2.5” x .75”, 1.7 oz
Portuguese, Chinese
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
11
LTC-3000w Turbidity, Chlorine & Color Laboratory Meter
1
1
Instrumentation
EPA
80.
LTC-3000we (EPA version); Code 1972-EPA
LTC-3000wi (ISO version) Code 1972-ISO
Kits supplied with 0, 1 and 10 NTU standards, 6 sample tubes, DPD tablets, USB cable and AC adapter.
The LTC-3000we uses a tungsten lamp and meets the specifications of EPA 180.1.
Industry leading precision, sensitivity and dependability in one of the most innovative meters
available on the market for the measurement of Turbidity, Chlorine and Color.
The LTC3000w is a benchtop turbidity, chlorine and color meter with wide range and
high accuracy. ISO unit also available. The meter meets EPA 180.1, Rev. 2.0 (1993)
and Standard Methods 2130 B-2001 for turbidity and Standards Methods 4500-Cl G
for chlorine. The turbidity range is 0-4,000 NTU with a MDL of 0.05 NTU. The free and
total chlorine range is 0-10 ppm with a MDL of 0.03 ppm. The meter can store 500 data
points which can be downloaded to a computer, allows 7 different languages, and runs
on rechargeable batteries or a USB computer/wall adapter.
Ideally suited for both low-level drinking water applications as well as monitoring
Data logging up to 500 points with a date and time stamp – stored tests can be
viewed on the meter or downloaded to a PC
Compatibility with existing SmartLink 3 software Easy to read graphic LCD display Easy menu-driven operation
Meter Features
Signal AverageDisabled, 2, 5, 10
PowerUSB computer cable, wall
adapter or Lithium ion
rechargeable battery, 3.7V,
2.5” x 0.75”, 1.7 oz
Data Logging500 points
Auto Shut-OffDisabled, 5, 10, 30
LanguagesEnglish, French, Spanish,
Japanese, Italian, Portuguese,
Chinese
Response Time<2 Seconds
Dimensions8.75 W x 7.75 D x 3 H inches
22.2 W x 19.7 D x 7.6 H cm
12
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
LTC-3000w, Turbidity, Chlorine & Color
Kits & Accessories
LTC-3000we US EPA Compliant, Order Code 1972-EPA, Turbidity (EPA 180.1, Rev. 2.0 (1993) and Standard Methods 2130 B-2001),
Chlorine (Standard Methods 4500-Cl G), Color (based on Standard Methods 2120 C)
LTC-3000wi ISO Compliant, Order Code 1972-ISO, Turbidity (ISO 7027), Chlorine (Standard Methods 4500-Cl G), Color (based on
Standard Methods 2120 C)
Instrumentation
0290-6Six pack of tubes
14800 NTU/FNU Standard (EPA and ISO), 60 mL
14501 NTU Standard (EPA), 60 mL
145110 NTU Standard (EPA), 60 mL
1452100 NTU Standard (EPA), 60 mL
14531 FNU Standard (ISO), 60 mL
145410 FNU Standard (ISO), 60 mL
1455100 FNU Standard (ISO), 60 mL
6903A-JChlorine DPD #1 Tablets, 100
Turbidity
Meets design criteria for quantitative methods of turbidity using
optical turbidimeters as specified by EPA 180.1, Rev. 2.0 (1993)
and Standard Methods 2130 B-2001
Two user selected factory calibration modes:
- Formazin
Polystyrene Japanese Turbidity Unit (Japanese Water Works
Regulation)
Supplied with formazin verified styrene divinylbenzene bead
suspensions (AMCO) for easy and accurate field calibration
User selected signal averaging (disabled, 2, 5 or 10
measurements)
Blanking with turbidity-free water allows a zero point calibration
for increased accuracy at very low turbidity levels
6197A-JChlorine DPD #3 Tablets, 100
1901-CDSMARTLink3 Software
6195-HFormazin standard solution, 4000 NTU, 60 mL
4140-02DPD Chlorine secondary standards kit
3176-02FAS-DPD Titration kit for chlorine titration
6973-HStandard chlorine solution, 250 ppm, 60 mL
6973-LStandard chlorine solution, 250 ppm, 475 mL
3858-HPermanganate solution, 1000 ppm, 60 mL
Unit of MeasureNTU, FNU, AU, FAU, ASBC, EBC
Range*0-4000, 0-10,500 ASBC, 0-150 EBC
Resolution*0.01 NTU/FNU 0.00-10.99; 0.1 NTU/FNU 11.0-109.9;
1 NTU/FNU 110-4000
Range SelectionAutomatic
Accuracy*From 0-2.5 NTU/FNU the accuracy is ±0.05 NTU/FNU.
From 2.5-100 NTU/FNU the accuracy is ±2%. Above
100 NTU/FNU the accuracy is ±3%.
Detection Limit0.05 NTU/FNU
Reproducibility*0.02 NTU/FNU, or 1%
Stray Light<0.02 NTU FNU
Light SourceTungsten (EPA), complies with EPA 180.1, Rev. 2.0
(1993) and Standard Methods 2130 B-2001, 860mm
LED (ISO), complies with ISO 7027
Signal AveragingDisabled, 2, 5, 10
*Over 600 NTU/FNU units expressed as AU/FAU
Chlorine
Exceeds design specifications for Standard Methods
4500-Cl G
Liquid and tablet DPD calibrations for Free and Total
Chlorine measurement
Wide-range accomplished with same cell and reagent
dosage
Low level detection. User selected units ppm or mg/L
Color
Uses Platinum-Cobalt method from Standard Methods 110.2 Wavelength 428 nm
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
Range0-10 ppm, Free and Total Chlorine
Resolution0.00-5.00 ppm Range: 0.01 ppm; 5.0-10.0 ppm Range:
Detection Limit0.03 ppm
Response Time<5 Seconds
Light Source525 nm LED, complies with Standard Methods 4500-Cl G
Range0-1000 cu
Detection Limit20 cu
Accuracy±15 cu
Light Source428 LED
13
SMART® Spectro Spectrophotometer
A spectrophotometer that is easy to use
and more accurate than anything in its
Instrumentation
price range. With automatic wavelength
selection, pre-programmed tests, and
superior performance—this is the best
spectrophotometer for the money!
Menu Driven Display
Tests and functions are selected from scrolling menus for ultimate
simplicity. Results are displayed as %T, absorbance, and concentration.
Pre-Programmed Tests, User Tests &
Automatic Wavelength Selection
Over 80 pre-programmed tests. Up to 25 calibrations for additional
tests can be entered into the memory. The user can also customize
sequences for frequently run tests. The meter automatically moves
the grating to the required wavelength.
To Order:
Order Code 2000-01 (120V/60Hz and 220V/50Hz)
Includes 6 sample cells (25mm round), 2 sample cell holders (25mm
round and COD, 10mm cuvettes), power supply, battery charger, and
diagrammed manual.
Wavelength Range:350-1000 nm
Wavelength Accuracy:±2 nm
Wavelength Resolution:1 nm
Wavelength Bandwidth:5 nm (max)
Photometric Range:0-125%T, -0.1-2.5A
Photometric Accuracy:±0.005A
Photometric Noise:<0.001A at 0A; <0.002A at 2A
Photometric Drift:±0.002A/hr @500 nm
Photometric Stray Light:<0.5 %T
Dispersive Device:Grating - based system
Optical Mount:Modified Ebert
Grating:1200 grooves/mm ruled grating
Light Source:Quartz halogen
Bulb Life:1000 hours minimum
Sample Chambers:25 mm round cell, 10 mm
square cuvette UDV, COD
Detector:Silicon photodiode
Temperature Range:0-40°C
Modes:Conc., %T, ABS
Pre-Programmed Tests:Yes
Wavelength Selection:Automatic
User Tests:Yes, up to 25 can be entered and
edited
Datalogging:Yes, RS-232, datalogs 500 tests
Diagnostics:Yes
Power:110/220 volt or battery pack
(rechargeable)
Weight:4.65 kgs (10.3 lbs)
Size (WxDxH:)35 cm x 28 cm x 17 cm
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com14
SMART® Spectro Spectrophotometer
Digestion Tubes for Total Nitrogen and Total Phosphorus
LaMotte offers low and high Total Phosphorus and a Total Nitrogen test that are reacted in a
heater block and are then tested using a colorimeter or spectrophotometer.
CodeDescriptionRange# of Tests
4024-01Low Total Phosphorus0-3.5 mg/L25
4025-01High Total Phosphorus0-100 mg/L25
4026-01Total Nitrogen0-25 mg/L25
Instrumentation
Multi-Range COD Reagent Systems
LaMotte-manufactured Chemical Oxygen Demand reagent systems used with our SMART3
Colorimeter or SMART Spectro Spectrophotometer are an easy and precise way to measure
critical COD levels. Measure low, medium or high levels of COD using your choice of mercury
(US EPA approved method) or non-mercury reagent systems. Each package contains 25
ready to use vials. All kits ship as R1.
This COD heater block features digital microprocessor control, programmable time and
temperature settings, and a dual LED display to monitor both temperature and timer. Perfect
for COD, Total Phosphorus, and Total Nitrogen testing PLUS other tests requiring digestion.
Temperature:30-200°C
Timer:0-999 minutes
Vial Capacity:12 (16 mm tubes)
Stability:±0.1°C@100°C
Weight:3.6 kg
Dimensions310 x 250 x 80mm (LxWxH)
CE Mark:Yes
Oven Temp Cutoff:212°C
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com15
UV/VIS Spectrophotometer
Instrumentation
80+ Test Factors including:
ALUMINUM
AMMONIA
CADMIUM
CHROMIUM
COBALT
COD LR
COD HR
COPPER
CYANIDE
FLUORIDE
IRON
LEAD
MANGANESE LR
MANGANESE HR
NICKEL
NITRATE
NITRITE
PHENOL
PHOSPHATE
SULFATE
ZINC
The UV-Vis Spectrophotometer is an expandable, easy-to-use instrument that
provides maximum performance in a
compact, benchtop package. The instrument includes a high precision optical
bench, full programming capabilities,
customizable standard curves, and over
80 preprogrammed tests. Available options
include a variety of sample holders as well
as software-based wavelength scanning
and kinetics.
Order Code 7-2000-UV
Programmable wide range spectrophotometer can accept up
to 200 user curves in memory
Pre-programmed to analyze selected tests on a direct-reading
digital display
Advanced key pad with 22 buttons simplifies data entry Includes one 10 mm quartz glass cuvette, six round 25 mm
10 mL test vials, universal sample holder and square sample
holder
†As ppm except as otherwise indicated *Requires COD Adapter Code 5-0087 and Heater Block
**UV lamp 31041-1; UV lamp power source 31041-2; UV safety goggles 31041
Spectro /
UV-VIS Range†# TestsCodeShip
∞
NANH
Continue next page...
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
17
Instrument Reagent Listing
Test FactorTest Method (# of reagents)SMART 3 Range†
† As ppm except as otherwise indicated * Requires COD Adapter Code 5-0087 and Heater Block
** UV lamp 31041-1; UV lamp power source 31041-2; UV safety goggles 31041
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
Model 1200 • Single Test Colorimeter Labs
The 1200 Series of single test, direct reading colorimeters incorporates design advances that enhance reliability,
improve accuracy, and simplify the calibration process, all in a portable, hand-held package.
Simply insert the sample blank and press the
zero key.
HINGED LIGHT COVER
Flip-top lid over sample chamber prevents any
stray light, especially in the field, and avoids
misplacing separate light caps.
IMPROVED ACCURACY
The microprocessor enables the factory programmed calibrations to optimally match nonlinear curves.
EUROPEAN CE MARK
The 1200 has been independently tested and
has earned the European CE Mark of compliance for electromagnetic compatibility and
safety.
WATER RESISTANT DESIGN
Designed with excessive exposure to moisture
in mind, the 1200 colorimeters deliver troublefree performace in the field and lab.
EPA COMPLIANT
Employing the proper wavelength and the DPD
test method, the 1200 Chlorine Colorimeter Kit
meets or exceeds EPA design specifications
for NPDWR and NPDES chlorine monitoring
programs (EPA 330.5 and Standard Methods
4500-Cl G).
A GREAT VALUE!
Complete, economical package! The 1200
Chlorine Colorimeter Kit comes with enough
tablets for 100 tests or liquid reagents for
140 tests, six sample vials with screw caps,
instruction manual, and sturdy coloring case.
Instrument Type:Single wavelength,
direct-reading
colorimeter
Readout:3½ digit LCD
Photometric Accuracy: ±0.001 Absorbance Unit
* Instrument DPD featuring new ultra-clear fast dissolving tablets.
Code
Ship
Code
50
60 mL
(2 oz.)
100
Code
1000
Ship
Code
Ship
Code
# of
Tests
Ship
Codes
20
DPD Powder Pop® Dispenser
LaMotte now offers the Powder Pop Dispenser – a hand held, single-dose dispenser for 10 mL samples that delivers a
precise pre-measured dose of DPD reagent directly to your sample. Each Powder Pop kit includes enough reagent for
400 tests.
To Order:
Free Chlorine Powder Pop Dispenser (Order Code 3-0032)
Total Chlorine Powder Pop Dispenser (Order Code 3-0033)
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
Model 1200 & 1200 UDV • Absorbance Colorimeters
Model 1200 & 1200 UDV • Absorbance Colorimeters
The versatile 1200 Series of single wavelength colorimeters now comes with the capability to display readings
directly in absorbance units. Six different wavelengths are available, with two sample vial options, to provide
maximum flexibility for your analytical procedures. Microprocessor control and advanced design assure accuracy,
easy operation, and durability.
Absorbance colorimeter kits are supplied with vials or cuvettes, water sample collecting bottle, 3 mL syringe
(1200-UDV only), all in a sturdy carrying case.
Instrumentation
Model 1200 Meter
For 25mm vials
Order Codes
Listed by wavelengths:
3627-420
3627-510
3627-530
3627-562
3627-570
3627-605
Model 1200-UDV
Meter
For 10mm cuvettes
Order Codes
Listed by wavelengths:
3627-420-UDV
3627-460-UDV
3627-510-UDV
3627-530-UDV
3627-562-UDV
3627-570-UDV
3627-605-UDV
Instrument Type:Single wavelength, absorbance
Measurement
Wavelengths:
Readable Resolution:0.01 Absorbance Unit
Photometric Precision: ±0.001 Absorbance Unit
Range:0-2.00 Absorbance Units
Display:3½ digit LCD
Response Time:2 seconds
Detector:Silicon Photodiode
Sample Chamber:Meters are available with one
Light Source:LED
Interface:RS-232 serial interface, 8 pin
Power:Battery Operation: Alkaline
colorimeter
420nm, 460nm, 510nm,
530nm, 562nm, 570nm, or
605nm
of two chambers to accept
25mm flat-bottomed glass
vials (1200) or 10 mm square
polystyrene cuvettes (1200UDV)
mDIN, 9600b, 8 data bits, 1
stop bit, no parity
9-volt DC battery; Line
Operation:
230V/50Hz with adapter
120V/60Hz,
Chlorine Standards for Model 1200 & SMART3
For use with the 1200 series and SMART3 chlorine colorimeters. Secondary standards provide a fast
way to check calibration without the burden of making primary standards. Based on Standard Methods
for the Examination of Water and Wastewater, the operator can calibrate a colorimeter using a permanganate primary standard or a chlorine primary standard. Once the meter is calibrated using the
primary standard, the operator can insert secondary standards periodically to evaluate the calibration
of the instrument.
Secondary standard kit contains a blank and 3 standards for low, mid-range, and high chlorine
calibrations.
Packaged in a small plastic case with Certificate of Analysis stating range of each standard.
To Order:
DPD Chlorine Secondary Standards, Order Code 4140-02
FAS-DPD Titration Kit for Chlorine Titration, Order Code 3176-02
Standard Chlorine Solution, 250 ppm, Order Code 6973-H (60 mL), Order Code 6973-L (475 mL)
Permanganate Solution, 1000 ppm, Order Code 3858-H (60 mL)
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
21
TRACER PockeTesters
The world’s first pocket-sized ISE meter for measuring total chlorine.
Use it to test pH and ORP with interchangeable flat surface sensors.
Total Chlorine TRACER
Instrumentation
Order Code 1740
Read Total Chlorine from 0.00-10 ppm
Readings are not affected by sample color or turbidity Automatic self calibration; extra bold display includes an analog bar graph feature; memory can store
up to 15 readings
Chlorine and pH modes also display sample temperature Unit identifies which probe is in use and retains calibrations Automatic shut-off and Low Battery indicator; uses four 3V CR-2032 batteries
Includes 100 reagent tablets at almost half the price of
similar Chlorine ISE reagents
Follows EPA protocol for ISE methods
TRACER KIT with pH, Total Chlorine and ORP probes
Order Code 1740-KIT-01
Includes Tracer meter with pH, Total Chlorine and ORP probes,
100 Chlorine tablets, 50 pH 7.0 buffer tablets, tablet crusher and
convenient carrying case.
1740-KIT-01
pH TRACER
Order Code 1741
Provided with 4, 7, and 10 pH buffer tablets.
Rugged flat surface electrode will alert user when it’s time to “RENEW” A “CAL” indicator shows when to recalibrate and user can select a 1, 2, or 3 point calibration Includes Automatic Temperature Compensation and displays temperature while showing pH result
Range:0.00 to 14.00 pH
Temp:32° to 149°F (0° to 65°C)
Resolution:0.01 pH
Accuracy:±0.01 pH
TRACER with pH and Total Chlorine probes
Order Code 1741-KIT-01
Includes Tracer with pH and Total Chlorine probe, 100 Chlorine tablets, 50 pH tablets, tablet crusher in
a convenient carrying case.
ORP TRACER
Order Code 1742
High resolution to 1 mV Automatic self calibration
Range:-999 to 999 mV
Resolution:1 mV
Accuracy:±4 mV
TRACER KIT
with pH and ORP probes
Order Code 1742-KIT-01
Includes Tracer with pH and ORP
probe, 100 Chlorine tablets, 50 pH
tablets, tablet crusher in a convenient carrying case.
OPTIONS
Additional Probes
Order Code 1733 pH Sensor (0-14.00/±0.01 pH)
Order Code 1734 ORP Sensor (±999mV/±4mV)
Order Code 1732 Cl2 Sensor (0-10.00/±10% of reading)
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com22
Chlorine Test Tablets
Order Code 7044A-J
Specially formulated just for the TRACER, these
deliver a precise amount of iodide for a 20 mL
sample. Available in packages of 100.
TRACER PockeTesters
Instrumentation
EC/TDS/SALT TRACER
Code 1749
Easy to use 2% accuracy for EC, TDS, and Salt modules Automatic temperature compensation Self calibration Memory can store up to 25 readings; auto-
power off after 10 minutes of no button
presses
Automatic shut-off and low battery indicator;
uses four 3V CR-2032 button batteries
Options:
EC/TDS/SAL Replacement Electrode*,
Order Code 1765
Sample Cup w/cap, Order Code 1745-1
Conductivity Standard, 84 µS,
Order Code 6312-G
Conductivity Standard, 1413 µS,
Order Code 6354-J
Conductivity Standard, 12,880 µS,
Order Code 6317-G
Conductivity: 0 to 199.9 µS, 200 to 1999 µS,
2.00 to 19.99 mS
TDS:0 to 9,999 ppm
Salinity:0 to 9,999 ppmTemperature32°F to 149°F (0 to 65°C)Accuracy:EC, TDS, Salt: ± 2% FS;
Temperature: ± 1°C (1.8°F)
*Not interchangeable with Cl/pH/ORP TRACER
Fluoride TRACER
Order Code 1756
The first Fluoride meter with built-in
Automatic Temperature Compensation
and fastest response (<1 min)
Small sample/TISAB volume required for testing Complies with EPA Method 340.2
(Potentiometric Ion Selective Electrode)
Automatic electronic 1 or 2 point calibration
with offset adjustment
Memory stores 25 labeled readings and
water resistant to IP54
Complete with electrode, 20 TISAB reagent tablets,
sensor cap, four 3V button batteries, and 48” (1.2m)
neckstrap
Fluoride TRACER KIT
Order Code 1756-KIT-01
Includes Tracer meter with 4 oz. bottle of 1 ppm
Fluoride Standard and convenient carrying case.
Options:
TISAB Reagent, 100 Tablets, Order Code 7024-J
Replacement Electrode, Order Code 1757
Fluoride Standard, 1 ppm, 1000 mL, Order Code 2798-M
Fluoride Standard, 1,000 ppm, 60 mL, Order Code 4154-H
Fluoride Standard, 1,000 ppm, 500 mL, Order Code 4154-L
Fluoride:0.1 to 10 ppm, max. resolution: 0.1 ppm, accuracy:
±3% rdg
Temperature32°F to 140°F (0 to 60°C), max. resolution: 0.1 °F,
Measures five parameters including Conductivity, TDS,
Salinity, pH, and Temperature using one electrode
Units of measure: pH, µS, mS, ppm, ppt, mg/L, g/L, °C, °F
Memory stores up to 25 labeled readings; auto power off and
low battery indicator
Adjustable Conductivity to TDS ratio
RangeResolutionAccuracy
Conductivity0 to 199.9 µS, 200 to 1999 µS, 2.00 to 19.99 mS0.1 µS±1%TDS/Salinity0 to 99.9 ppm (mg/L), 100 to 999 ppm (mg/L), 1.00 to 9.99 ppt 0.1 ppm (mg/L) ±2%pH0.00 to 14.00 pH0.01 pH±0.01 pHTemperature32° to 149°F (0 to 65°C)0.1°F/°C±1.8°F/°C
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
See pages 32
for pH Tablets
Options:
pH/EC/TDS/SAL Replacement Electrode*, Order Code 1755
Sample Cups w/cap, Order Code 1745-1
Conductivity Standard, 84 µS, Order Code 6312-G
Conductivity Standard, 1413 µS, Order Code 6354-G
Conductivity Standard, 12,880 µS, Order Code 6317-G
23
Dissolved Oxygen Meters
Dissolved Oxygen Tracer
Order Code 1761
Instrumentation
Oxygen level displayed as % Saturation from 0 to 200.0% or Concentration from 0 to 20.00 ppm (mg/L) Adjustable Altitude Compensation (0-20,000 ft in 1,000 ft increments) Adjustable Salinity Compensation from 0 to 50 ppt Memory stores up to 25 data sets with DO and Temperature reading Self-calibration on power up; Data, Hold, Auto power off, Low battery indicator Waterproof to IP67 Optional 3 ft (1m) or 16 ft (5m) extension cable; complete with DO electrode, protective sensor cap, spare membrane
cap, electrolyte, four 1.5V CR-2032 batteries, and 48” (1.2m) neckstrap
RangeResolutionAccuracy
DO (sat. mode)0 to 200.0%0.1%±2% FS
DO (conc. mode) 0 to 20.00 ppm (mg/L)0.01 ppm (mg/L)0.4 ppm (mg/L)
Temp.32 to 122°F (0 to 50°C)0.1°F/°C±1.8°F (1°C)
Dimensions1.4x6.9x1.6” (36x176x41mm)
Weight3.8 oz (110g)
Dissolved Oxygen Meter
Order Code 5-0107-01
No meter warm-up required Low-maintenance probe Key in salinity and pressure values manually Independent 100% and zero adjustment calibrations Offset adjustment capabilities Displays electrode diagnostics Easily toggle from
mg/L (ppm) or
% saturation to
temperature
mode
Accessories
DO Membrane Kit, 6 screw-on
membranes and solution
(Order Code 1761M)
DO Sensor Module
(Order Code 1762)
3 ft. Cable (Order Code 1763) 16 ft. Cable (Order Code 1764)
RangeResolutionAccuracy
mg/L (ppm)0.00 to 20.00 mg/L
% Saturation0.0 to 200.0%0.1%±1.5% FS
Temp.-5.0 to 105.0°C 0.1°C±0.5°F
Salinity correction0.0 to 50.0 ppt0.1 pptMethod: Key
Barometric pressure
correction
Temperature
compensation
Operating temperature0 to 50°C
ProbeGalvanic, 3 ft. probe cable
PowerFour 1.5 V AAA batteries (included), >700 hrs
Dimensions5.5”L x 2.7”W x 1.3”H
Weight1.0 lb (0.45 kg)
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
PockeTesters
PAGE
pH PockeTester 10
Order Code 5-0103
±0.1 pH accuracy
pH PockeTester 20
Order Code 5-0104
±0.01 pH accuracy
Both meters feature automatic temperature compensation, and buffer recognition for
three point calibration based on US (pH 4.01, 7.00, 10.01) or NIST (pH 4.01, 6.86, 9.18)
systems. The sensor is a double junction Ag/AgCl system with polymer gel. The IP67 rated
housing features a 1.0625” (26.99 mm) display, which also displays diagnostic messages.
Auto-off after 8.5 minutes to conserve battery life.
(Replacement Electrode, Code 5-0097)
(Replacement Electrode, Code 5-0097)
Instrumentation
Double Junction ORP PockeTester
Order Code 5-0079
–999 mV to +1000 mV Large surface area platinum band sensor 1 mV resolution, 2 mV accuracy HOLD function, Auto-off
for complete PockeTester specs
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com25
PockeTesters
Instrumentation
Code 5-0080
Microprocessor-Based TDS
Dual Range PockeTester
Order Code 5-0080
0-2000 ppm (10 ppm resolution) ; 0-10.00
ppt (0.10 ppt resolution)
±1% full-scale accuracy Automatic temperature compensation (ATC) Replacement electrode Push-button calibration Auto shut-off Full reading displayed – no need to multiply
Replacement Probe (Order Code 5-0084)
Code 5-0078Code 5-0082
Salt PockeTester
Order Code 5-0078-01
0–10 ppt ( 0.10 ppt resolution) Carrying Case and calibration standard
included
Replacement Probe
(Order Code 5-0084)
Microprocessor-Based EC
Conductivity Dual Range
PockeTester
Order Code 5-0082
0-2000 µS (10 µS resolution); 0-20.00 mS
(0.10 mS resolution)
±1% full-scale accuracy Automatic temperature compensation (ATC) Replacement electrode Push-button calibration Auto shut-off Full reading displayed – no need to multiply
Replacement Probe (Order Code 5-0084)
26
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
PockeTester Specifications
Specifications for pH PockeTestersSpecifications for Specialty PockeTesters
ModelpH PockeTester 10pH PockeTester 20Min-Max ThermometerORP PockeTesterSalt
Code5-01035-01045-00955-00795-0078-01
Range–1.0 to 15.0 pH; extended range–10 to 200°F,
Resolution0.1 pH0.01 pH0.1°F to 199.9°,
Accuracy±0.1 pH±0.01 pH±1.8°F / ±1.0°C±2 mV±10%
CalibrationSelect up to 3 points
Operating
Temperature
Temperature
Compensation
Special
Functions
Power &
Battery Life
(4.0, 7.0, 10.0 or 4.01, 6.86, 9.18)
32 to 122°F;
0 to 50°C
Automatic (ATC)
0 to 50°C
On/Off or Auto-Off after 8.5 min.; HOLD;
CALibrate; CONfirm
Four 1.5V alkaline button cell batteries
(supplied), 500 hour use
32 to 122°F;
0 to 50°C
14 to 392°C
1°C above 200°
Factory calibrated; fine
adjustment through
keypad
32 to 122°F;
0 to 50°C
——Automatic(ATC)
On/Off or Auto-Off after
8.5 min.; HOLD; °F or °C
scale selectable; factory
calibration maintained
when batteries are
replaced
LR-44 button cell. 2 yr lifeFour 1.5V alkaline
–999 mV to +1000 mV0-10.00 ppt salinity
1 mV0.10 ppt salinity
full-scale
Offset calibration to
ORP standard or work
standard
32 to 122°F;
0 to 50°C
On/Off or Auto-Off after
8.5 min.; CALibrate;
CONfirm; HOLD (HO) and
HOLD/ CANCEL (HC)
batteries (supplied) 500
hrs. use
One-point with
trimpot
32 to 122°F;
0 to 50°C
0 to 50°C
Four 1.5V alkaline
batteries (supplied)
150 hrs. use
Instrumentation
Dimensions &
Weight
ModelTDS Dual RangeEC Dual Range
Code5-00805-0082
Replacement Electrode5-00845-0084
Range0-2000 ppm/ 0-10 ppt0-2000 µS; 0 to 20 mS
Resolution10 ppm/0.10 ppt10 µS; 0.10 mS
Accuracy±1%FS
CalibrationOne-point, push-button calibration using buttons inside battery compartment
Operating Temp.32 to 122°F; 0 to 50°C
Temperature Comp.Automatic (ATC) 0 to 50°C
Special FunctionsFull reading displayed
Power & Battery LifeFour 1.5V alkaline batteries (supplied); 150 hours
Dimensions & Weight8.5” (216 mm) L x 2.4” (61 mm) W x 2.5” (64 mm) H (boxed);
8.5” (216 mm) L x 2.4” (61 mm) W x 2.5” (64 mm) H (boxed); 6.5” (165 mm) L x 1.5” (38 mm) Dia. (unit only);
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
27
Temperature Measurement
Instrumentation
IR Meter with Color Alert System
Code 5-0133
Convenient non-contact temperature measurements, now with a laser
sighting, plus color and sound alerts!
Features
Fast and accurate measurements at 12” where the two lasers
converge with 12:1 field of view
Measures up to 950°F (510°C) Blue backlit dual LCD display changes to Red backlit outside set
points
Instantaneous response captures spikes in temperature Max mode captures and holds rapidly changing temperatures Lock function for continuous readings Adjustable emissivity increases measurement accuracy for
different surfaces
Double molded housing Complete with case and 9V battery Adjustable High/Low set points with color and audible alarms
signal out of range temperature
Blue backlight:
within temperature
range
Red backlight
plus audible
alert: exceeds
temperature
“Min-Max” Memory Thermometer
Order Code 5-0095
Range: 14 – 392°F or -10 – 200°C °F or °C selectable scale Recalls minimum and maximum temperature
Range:-4 to 950°F (-20 to 510°C)
Resolution:1°C/1°F
Accuracy:25 to 260°C (77 to 500°F): ±(1% of rdg
+2°F/1°C)
Repeatability:±0.5% or 1.8°F/1°C
Response Time:150mSec
Emissivity:0.10 to 1.00 adjustable
Distance-to-Spot Size:12:1Power:One 9V alkaline batteryDimensions:5.7 x 4 x 1.6 inches (146 x 104 x 43 mm)Weight:5.74 oz. (163g)
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com28
LaMotte pH, CON, TDS Meters
Instrumentation
Economical Field Meters
Push button operation Up to five point calibration Temperature readout Automatic Temperature Compensation Auto-off after 17 minutes; Hold function Buffer recognition (pH 5 meter) Adjustable conductivity to TDS factor (TDS 6 meter)
Microprocessors have enabled meter manufacturers to combine many features into
smaller designs with better accuracy. The 5 and 6 Series meters are good examples
(see specifications below). All meters include electrodes and temperature probes,
and are available with or without a carrying case.
The pH 5 without case includes pH 4, 7 and 10 buffer tablets. The pH 5 with case includes pH 4, 7 and 10 buffer liquids. The TDS 6 and Con 6 with carrying cases include two calibration standards. All meters have two-year warranties.
Model
Order Codew/out case 5-0034-01
Replacement
Probe
Range:0.00 to 14.00 pH0.0 to 100.0°C0.0 to 20.00,
Resolution:0.01 pH0.1°C0.01, 0.1, 1 µS
Accuracy:±0.01 pH±0.5°C±1% full scale or ±1 digit±1% full scale±0.5°C
Calibration:Up to 5 Buffer Values Offset 0.1°C
Automatic Temperature Compensation (ATC)Automatic Temperature Compensation (ATC)
pH 5
(pH)
pH Probe
Order Code 1904
hours continuous use
32 to 122°F; 0 to 50°C32 to 122°F; 0 to 50°C
Temperature Probe
Order Code 5-0041
pH 5
(Temperature)
w/out case 5-0038-02
with case 5-0039-02
0 to 20.00, 200.0 mS
up to 5 points (1 per range) for multi-point calibration;
increments
CON 6 Meter
(Conductivity)
w/out case 5-0036-02
with case 5-0037-02
CON/TDS Probe
Order Code 5-0106
200, 2,000.0 µS
0.01, 0.1 mS
or 1 point for single point for entire range
0.0 to 10.00, 100.0, 1000 ppm,
1.0 to 10.00, 100.0, 200 ppt
0.01, 0.1, 1.0 ppm
fixed 2% per °C factor, adjustable 73%
Four AA alkaline batteries (supplied)
>100 hours continuous use
TDS 6 Meter
(TDS)
0.01, 0.1 ppt
CON 6 & TDS 6
Meters
(Temperature)
-10.0 to 110.0°C
0.1°C
Offset 0.1°C
increments
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
29
pHPLUS Direct Digital pH/ISE Meter
Instrumentation
pHPLUS DIRECT Meter
Laboratory precision in a water-resistant design!
Read pH, mV/R.mV, temperature, and concentration
with accuracy – ISEs read concentration in ppm. Easyto-use in any test mode. Includes pH probe, temperature
probe, buffers and rubber boot with stand.
Specifications
pH
Range:0.00 to 14.00
Resolution:0.01
Accuracy:0.01
Calibration:Up to 5 points
Electrode:Epoxy, Ag/AgCl
Temperature
Range:0 to 100°C
Resolution:0.1°C
Accuracy:±0.1°C
Concentration
Range:0.00 to 100
Resolution:± LSD
Accuracy:±0.5% or ±1 LSD
mV/R.mV
Power:4 AAA batteries
Size (LxWxH):2.75W x 5.75H x 1.375D in.
Optional ISE Electrodes*
Although the pHPLUS Direct reads directly in ppm, an initial calibration is
required. The standard solution, replacement electrolyte, ionic strength adjustor and pipet are included in the Accessory Kit. The ammonia accesory kit