Lamotte Water Quality Testing Products guide

Page 1
Water Quality Testing Products
SOLVING ANALYTICAL CHALLENGES SINCE 1919
Page 2
The Next Revolution in Water Analysis is Here!
See pages 36-37
See pages 34-35
See page 73
Page 3
TO ORDER - SEE BACK COVER
Capabilities ............................................................................................................ Page 4
CUSTOM KIT SERVICES & INTERNATIONAL SALES
Custom Kit Services & International Sales ............................................. Page 5
TEST METHODS
Colorimetric ......................................................................................................... Page 6
Electronic ...........................................................................................................................7
Titrimetric .........................................................................................................................7
INSTRUMENTATION
SMART 3 Colorimeter .................................................................................Pages 8-9
2020w Portable Turbidity Meters .................................................................. 10-11
LTC-3000w Turbidity & Chlorine Laboratory Meter ............................... 12-13
SMART Spectro Spectrophotometer ........................................................... 14-15
COD Reagents & Heater Blocks ............................................................................ 15
UV-VIS Spectrophotometer .................................................................................. 16
Instrument Reagent Listing ........................................................................... 17-18
1200 Single Test Colorimeter Labs ............................................................. 19-21
TRACERS: Total Chlorine, pH, ORP, Options, EC/TDS/Salt ................... 22-24
pH/Conductivity, DO
Dissolved Oxygen Meters ......................................................................................... 24
PockeTesters: pH, Double Junction ORP, Salt, Thermometer, ......... 25-27
Microprocessor-Based TDS and EC Dual Range
Temperature Measurement ....................................................................................28
LaMotte pH, TDS, Conductivity Meters .............................................................. 29
pHPLUS Direct Digital pH/ISE Meter and Electrodes .................................. 30
DPD Replacement Reagents .................................................................................. 31
pH Buffers/Electrode ................................................................................................. 32
Conductivity Solutions ...............................................................................................33
INSTA-TEST
Insta-Test
®
TEST STRIPS
®
Test Strips ........................................................................ Pages 34-35
Since 1919
Helping people solve analytical
challenges by providing
innovative solutions through
knowledgeable technical
guidance, prompt service, and
quality products designed for the
MICROBIOLOGICAL TESTING
Microbiological Testing ........................................................................Pages 36-38
INDIVIDUAL TEST KITS
Acidity to Zinc Test Kit Listing ..........................................................Pages 39-55
COMBINATION OUTFITS
Aquaculture & Aquarium Water .................................................................Page 56
Environmental Studies ..................................................................................... 57-60
Food/Laundry ........................................................................................................ 61-62
General Water Analysis ...................................................................................... 63-64
Industrial Waters ................................................................................................. 65-66
Pool & Spa Waters ............................................................................................. 67-71
Water & Wastewater .......................................................................................... 72-73
Water Conditioning ............................................................................................. 74-75
REAGENT REFILLS
Numerical Listing ................................................................................. Pages 76-83
APPARATUS
Beakers to Thermometers ...................................................................Page 84-90
CATALOGS & HANDBOOKS
Application Specific Catalogs & Handbooks .................................Page 91-92
STANDARDS
Complete List of Standards ............................................................. Pages 93-94
analysis of water and soil.
INDEX
Acidity to Zinc .......................................................................................... Pages 95-98
Page 4
LaMotte Company manufactures its products at its 65,000 square foot facility in Chestertown, Maryland, near
Washington, DC on the east coast of the United States.

Capabilities

Over 10 years into our Lean Man-
ufacturing journey, LaMotte’s
chemists, engineers, and techni-
cians continue to optimize a wide
variety of processes to achieve
maximum quality and efficiency.
We offer a wide range of test
methods and tools for the ana-
lyst, from multi-factor test strips,
foil-packaged unit dose tablets,
unit dose powder vials, and liquid
reagents to sonic-welded color
comparators, multi-
parameter test
kits, and electron-
ic instruments.
LaMotte controls
the manufacturing
of all aspects to
ensure the high-
est quality.
4
We believe strongly in having a team of technical experts available by phone and email for customer support. The Research and Devel-
opment team works to constantly improve and create new test methods. Our in-house graphic design department provides extensive
services that are especially valuable for the many custom designed products that LaMotte welcomes.
All of these varied capabilities enable LaMotte to excel at helping people solve their analytical challenges.
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
Page 5
If your needs go beyond our standard product line, then our Custom Test Kit Services Department can design a custom kit to meet your needs.
WE CAN design a kit that combines any
grouping of parameters you need.
WE CAN develop new test methods for new
proprietary compounds or for control of
specialized treatment programs
Custom | Int’l Sales
Custom Test Kit Services
WE CAN alter existing graphics and
packaging or design something new for
private labeling purposes
Available online at www.lamotte.com:
Entire Product Listing with Full Descriptions Printable Test Instructions Printable MSDSs Printable Reagents Certificates of Analysis
How The Custom Test Kit Service Works
1. Contact our Customer Service or International Sales departments by phone,
fax, or email. Tell us how you plan to use the product, the level of accuracy and range you need, how many kits, and any limitations such as size, weight, cost, or skill level of the end user (i.e. student, consumer, technician).
2. We will prepare a quote for you. Based on the information you provide, we will
suggest one of our non-catalog test kits or develop a kit to suit your needs.
3. Once you order, we immediately begin the development process, subject to
final approval before beginning production.
International Sales
Worldwide Distributor Network
For Pricing and To Order, contact a distributor near you.
To locate a LaMotte distributor, visit www.lamotte.com and select “INTERNATIONAL”. For more information email us at intl@lamotte.com.
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
5
Page 6
Colorimetric
See Methods Videos
Colorimetric
There are two basic types of colorimetric tests:

Test Methods

1. Tests which determine the concentration of a substance are based on Beer’s Law. Simply stated, this says that the higher the concentration of a
substance, the darker the color developed in the test, so more light is absorbed by the sample.
2. pH tests use an indicator which changes color with changes in the concentration of hydrogen ions, or the acidity of the solution.
Octa-Slide 2 Comparator
The Octa-Slide 2 replaces the Octet and Octa-Slide comparators. All 8 color standards can be viewed at once against a preci­sion matched color bar top-loaded next to the sample tube. This com parator system can be used with existing re agent system but is not compatible with color bars from the original Octa-Slide.
-
-
IN OPERATION!
LRC Comparator
This innovative design replaces the Axial Reader with a simpler and significantly improved op­tical system. Simply place one reacted sample in the front and one un-reacted sample behind it and let the light shine down into both tubes. Precision matched glass ampoules are in the slide bar so even the most sensitive low range colors can be matched one-on-one with ex­traordinary ease and confidence.
6
Test Strips
Test strips are either dipped or swirled in test solutions. The resulting color reaction is compared to a color chart provided.
Color Chart Comparator
Color charts are laminated color standards. The reacted sample is held against the panel and compared to the color standards.
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
Page 7
Electronic • Titrimetric
Electronic Methods
Electronic colorimeters measure the amount of light which travels through the reacted sample, and convert the measurement to a reading as ppm, absorbance or %T. In addition to colorimeters, LaMotte offers instruments to test pH, TDS/conductivity, dissolved oxygen, and turbidity.
Test Methods
Titrimetric
Titrimetric tests can be used to determine the concentration of a substance in a sample solution. After the sample is treated with an indicator, a stan­dard titrant is added until a color change indicates a completed reaction. LaMotte offers four separate types of titration methods, allowing a choice of precision and convenience.
Automatic Buret
Direct Reading Titrator
The Direct Reading Titrator is a 1.0 mL microburet calibrated to allow direct reading of the test result. Each Titrator has a specific range, but may be refilled to test higher concentrations.
Dropper Pipet
The drop count test uses a pipet to provide fast, reliable measurements in the field. The number of drops used to obtain a color change is multiplied by a given factor to produce the test result.
Dropper Bottle
The dropper bottle test uses bottle tips which deliver a consistent standard drop size to add titrant to the sample. As with the drop count test, the number of drops used to complete the reaction is multiplied by a given equivalence factor to determine the concentra­tion. Many dropper bottle tests use different sample sizes for different equivalences.
The self-zeroing automatic buret is calibrated from 0 to 10 mL in 0.1 mL increments. It is available with a squeeze valve (pinchcock), glass stop­cock, or Teflon® stopcock.
See page 85 for full line of au­tomatic burets.
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
7
Page 8
SMART3 Colorimeter
Replaceable cup
protects optics

Instrumentation

6-button keypad
Over 80 Pre-Programmed Tests
New Bolder
Backlit Display
Simple
Code 1910
The user-friendly SMART3 Colorimeter is the ideal direct reading colorimeter for complete on-site water analyses.
All pre-programmed tests can be run on these compact instruments and each test features automatic wavelength selection. The entire multi-LED optical system is embedded in the light chamber and optimized for LaMotte test reagent systems. The analyst can simply select the test and put in the sample with reagent. The microprocessor, which selects the wavelength, also allows the user to load up to 25 tests for analyzing custom reagent systems. LaMotte stands behind every system we provide.
These portable colorimeters have the user in mind with these advanced features:
 IP67 Waterproof  Simple, menu-driven operation  Alphabetical test selection  User-selected test sequences  Self diagnostics with error/warning messages  Instant readiness without “count down” delays; achieved by active
stabilization of lamp intensity
 Auto-blank; Auto-off  European CE mark
The user may select any of the wavelengths in each meter to determine the absorbance or %T of a sample at the desired wavelength.
Additional advancements include:
 Superior narrow band-width interference filters  New LCD display for improved readability  USB interface  Optional software for data storage and manipulation  Lithium ion rechargeable battery, USB computer adapter is
included
As well as the incorporated features:
 All wavelength filters - 428, 525, 568, 635 nm (SMART3 only)  USB port  and more...
* SMART 3 Turbidity is not the same as EPA 180.1 Turbidity
SMART Colorimeter® is a registered trademark of LaMotte Company.
8
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
Page 9
SMART3 Colorimeter & SMARTLink 3
See pages 17-18 for
complete reagent
system listing.
Instrumentation
Range: 0-125%T Resolution: 1% FS Accuracy: 2% FS CE Mark: Yes
Light Source: LED/Filter setup; 428nm, 525nm, 568nm, 638nm Detector: Photodiode
Display: 160x100 Backlight LCD, 20x4 line graphics display Sample Cell: 25 mm round cell, 10 mm square cuvette, 16 mm COD tubes Datalogging: Up to 500 data points, USB transfer, time and date stamped Keypad: 6-button mechanical Calibration: Factory set - user adjustable Power: USB computer/power charger or Lithium Ion rechargeable battery,
3.7V, 2.5” x 0.75”, 1.7 oz.
Dimensions: 19.05 x 8.84 x 6.35 cm; 7.5 x 3.5 x 2.5 inches Weight: 15 ounces Bandwidth: 10 mm typical
SMART3 • Code 1910
Comes with 6 sample tubes, power charger and manual
Accessories/Replacement Items:
Smartcheck Standards Code 4148 Replacement Sample Code 3-0038
Chamber Cup COD/UDV adapter Code 1724 6 sample tubes Code 0290-6 USB Cable Code 1720 USB Power Plug Code 1721 Car Charger Code 5-0132 Small Case Code 1910-GCS150 Large Case Code 1910-GCS440
SMARTLink 3 Program
Order Code 1901-CD
Interface the SMART3, 2020w and LTC-3000w meters with a Windows-based personal computer. The program can be used to download data stored in the dataloggers of these meters. The program allows the user to iden­tify, organize, view, manipulate and store data as a database on a PC. Data can also be copied and pasted or exported to other applications as a CSV file.
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
9
Page 10
2020w Portable Turbidity Meters
1
1
Instrumentation
Industry-leading precision, sensitivity, and dependability in one of the most
innovative WATERPROOF, handheld meters available on the market!
EPA
80.
The multi-detector optical configuration assures long term stability and minimizes stray light and color interferences. All readings are determined by the process of signal averaging over a 5 second period. This minimizes fluctuations in readings attributed to large particles and results in rapid, highly repeatable measurements. Ideally suited for both low-level drinking water applications as well as monitoring high turbidity in the field.
 Seven user selected languages – English, Spanish, French, Japanese, Chinese, Italian,
and Portuguese
 Advanced calibration algorithms  Best for low range turbidity analysis  Easy menu driven operation and large LCD display
Waterproof to IP67
Lithium rechargeable batteries
 500 point data log; stored results can be viewed directly on instrument or downloaded to a
computer via USB cable and SmartLink 3 software (available separately)
10
USB port
7 languages
Backlit display
EPA and ISO versions
2020we version meets US EPA design criteria as specified by EPA 180.1, Rev. 2.0 (1993) and Standard Methods 2130 B-2001.
2020wi version meets design criteria for quantitative methods of turbidity using optical turbidim­eters as specified by ISO 7027. Best for colored or extremely turbid samples.
Kits are supplied with 0, 1, and 10 NTU standard, sample bottle, four sample tubes, USB cable and wall adapter.
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
Page 11
2020w Portable Turbidity Meter
Instrumentation
To Order:
2020we Kit • Portable turbidity meter complies with by EPA 180.1, Rev. 2.0 (1993) and Standard Methods 2130 B-2001 Order Code 1970-EPA
2020wi Kit • Portable turbidity meter complies with ISO 7027 Standard Order Code 1970-ISO
Accessories:
 0 NTU/FNU Standard (EPA and ISO),
60 mL; Code 1480
 1 NTU/FNU Standard (EPA and ISO),
60 mL; Code 1453
 10 NTU/FNU Standard (EPA and ISO),
60 mL; Code 1454
 100 NTU Standard (ISO), 60 mL;
Code 1455
 1 NTU Standard (EPA), 60 mL;
Code 1450
 10 NTU Standard (EPA), 60 mL;
Code 1451
 100 NTU Standard (EPA), 60 mL;
Code 1452
 Formazin Standard Solution,
4000 NTU, 60 mL; Code 6195-H
 USB Cable, Code 1720  Wall Adapter, Code 1721  SMARTLink 3 Software; Code 1901-CD  Six-pack of vials; Code 0290-6  Car Charger; Code 5-0132  Chamber Cup; Code 3-0038
Kits are supplied with 0, 1, and 10 NTU/FNU standards, sample bottle, six sample tubes, USB cable and wall adapter—all in a sturdy carrying case.
Turbidity Specifications:
Unit of Measure
2020we
Units of Measure
2020wi
Range* 0-4000 NTU/FNU, 0-10,500 ASBC, 0-150
Resolution* 0.01 NTU/FNU 0.00-10.99
Accuracy* From 0-2.5 NTU the accuracy is ±0.05 NTU.
Detection Limit
Range Selection
Reproducibility* 0.02 NTU/FNU or 1% Light Source Tungsten (EPA), complies with EPA 180.1,
NTU, AU, ASBC, EBC
FNU, FAU, ASBC, EBC
EBC
0.1 NTU/FNU 11.0-109.9 1 NTU/FNU 110-4000
From 2.5-100 NTU the accuracy is ±2%. Above 100 NTU the accuracy is ±3%.
0.05 NTU/FNU
Automatic
Rev. 2.0 (1993) and Standard Methods 2130 B-2001; 860nm LED (ISO), complies with ISO
7027
Meter Features:
Signal Averaging Disabled, 2, 5, 10 Power USB computer cable, wall adapter or Lithium ion
AC Power Optional
Data Logging 500 points Auto Shut-Off Disabled, 5, 10, 30 seconds
Optional Software SmartLink 3 Languages English, French, Spanish, Japanese, Italian,
Response Time <2 Seconds Size 7.5 x 3.5 x 2.5 inches; 19.05 x 8.84 x 6.35 cm Weight 13 ounces
Display 6-line LCD with backlit display
*Over 600 NTU/FNU units expressed as AU/FAU
rechargeable battery, 3.7V, 2.5” x .75”, 1.7 oz
Portuguese, Chinese
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
11
Page 12
LTC-3000w Turbidity, Chlorine & Color Laboratory Meter
1
1
Instrumentation
EPA
80.
LTC-3000we (EPA version); Code 1972-EPA LTC-3000wi (ISO version) Code 1972-ISO
Kits supplied with 0, 1 and 10 NTU standards, 6 sample tubes, DPD tablets, USB cable and AC adapter.
The LTC-3000we uses a tungsten lamp and meets the specifications of EPA 180.1.
Industry leading precision, sensitivity and dependability in one of the most innovative meters available on the market for the measurement of Turbidity, Chlorine and Color.
The LTC3000w is a benchtop turbidity, chlorine and color meter with wide range and high accuracy. ISO unit also available. The meter meets EPA 180.1, Rev. 2.0 (1993) and Standard Methods 2130 B-2001 for turbidity and Standards Methods 4500-Cl G for chlorine. The turbidity range is 0-4,000 NTU with a MDL of 0.05 NTU. The free and total chlorine range is 0-10 ppm with a MDL of 0.03 ppm. The meter can store 500 data points which can be downloaded to a computer, allows 7 different languages, and runs on rechargeable batteries or a USB computer/wall adapter.
 Ideally suited for both low-level drinking water applications as well as monitoring
high turbidity
 Special focusing optics  Supports 7 languages: English, French, Spanish, Chinese, Japanese, Portuguese
and Italian
 Data logging up to 500 points with a date and time stamp – stored tests can be
viewed on the meter or downloaded to a PC
 Compatibility with existing SmartLink 3 software  Easy to read graphic LCD display  Easy menu-driven operation
Meter Features
Signal Average Disabled, 2, 5, 10
Power USB computer cable, wall
adapter or Lithium ion rechargeable battery, 3.7V,
2.5” x 0.75”, 1.7 oz
Data Logging 500 points
Auto Shut-Off Disabled, 5, 10, 30
Languages English, French, Spanish,
Japanese, Italian, Portuguese, Chinese
Response Time <2 Seconds
Dimensions 8.75 W x 7.75 D x 3 H inches
22.2 W x 19.7 D x 7.6 H cm
12
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
Page 13
LTC-3000w, Turbidity, Chlorine & Color
Kits & Accessories
LTC-3000we US EPA Compliant, Order Code 1972-EPA, Turbidity (EPA 180.1, Rev. 2.0 (1993) and Standard Methods 2130 B-2001), Chlorine (Standard Methods 4500-Cl G), Color (based on Standard Methods 2120 C)
LTC-3000wi ISO Compliant, Order Code 1972-ISO, Turbidity (ISO 7027), Chlorine (Standard Methods 4500-Cl G), Color (based on Standard Methods 2120 C)
Instrumentation
0290-6 Six pack of tubes 1480 0 NTU/FNU Standard (EPA and ISO), 60 mL 1450 1 NTU Standard (EPA), 60 mL 1451 10 NTU Standard (EPA), 60 mL 1452 100 NTU Standard (EPA), 60 mL 1453 1 FNU Standard (ISO), 60 mL 1454 10 FNU Standard (ISO), 60 mL 1455 100 FNU Standard (ISO), 60 mL 6903A-J Chlorine DPD #1 Tablets, 100
Turbidity
 Meets design criteria for quantitative methods of turbidity using
optical turbidimeters as specified by EPA 180.1, Rev. 2.0 (1993) and Standard Methods 2130 B-2001
 Two user selected factory calibration modes:
- Formazin Polystyrene Japanese Turbidity Unit (Japanese Water Works
­Regulation)
 Supplied with formazin verified styrene divinylbenzene bead
suspensions (AMCO) for easy and accurate field calibration
 User selected signal averaging (disabled, 2, 5 or 10
measurements)
 Blanking with turbidity-free water allows a zero point calibration
for increased accuracy at very low turbidity levels
6197A-J Chlorine DPD #3 Tablets, 100 1901-CD SMARTLink3 Software 6195-H Formazin standard solution, 4000 NTU, 60 mL 4140-02 DPD Chlorine secondary standards kit 3176-02 FAS-DPD Titration kit for chlorine titration 6973-H Standard chlorine solution, 250 ppm, 60 mL 6973-L Standard chlorine solution, 250 ppm, 475 mL 3858-H Permanganate solution, 1000 ppm, 60 mL
Unit of Measure NTU, FNU, AU, FAU, ASBC, EBC Range* 0-4000, 0-10,500 ASBC, 0-150 EBC Resolution* 0.01 NTU/FNU 0.00-10.99; 0.1 NTU/FNU 11.0-109.9;
1 NTU/FNU 110-4000
Range Selection Automatic Accuracy* From 0-2.5 NTU/FNU the accuracy is ±0.05 NTU/FNU.
From 2.5-100 NTU/FNU the accuracy is ±2%. Above 100 NTU/FNU the accuracy is ±3%.
Detection Limit 0.05 NTU/FNU Reproducibility* 0.02 NTU/FNU, or 1% Stray Light <0.02 NTU FNU Light Source Tungsten (EPA), complies with EPA 180.1, Rev. 2.0
(1993) and Standard Methods 2130 B-2001, 860mm LED (ISO), complies with ISO 7027
Signal Averaging Disabled, 2, 5, 10
*Over 600 NTU/FNU units expressed as AU/FAU
Chlorine
 Exceeds design specifications for Standard Methods
4500-Cl G
 Liquid and tablet DPD calibrations for Free and Total
Chlorine measurement
 Wide-range accomplished with same cell and reagent
dosage
 Low level detection.  User selected units ppm or mg/L
Color
 Uses Platinum-Cobalt method from Standard Methods 110.2  Wavelength 428 nm
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
Range 0-10 ppm, Free and Total Chlorine Resolution 0.00-5.00 ppm Range: 0.01 ppm; 5.0-10.0 ppm Range:
0.1 ppm
Accuracy Tablet: 0-1.0 ppm Range: ±0.03 ppm
1.0-3.0 ppm Range: ±0.06 ppm
3.0-6.0 ppm Range: ±0.3 ppm
6.0-10.0 ppm Range: ±2.5 ppm Liquid: 0-0.5 ppm Range: ±0.03 ppm
0.6-3.0 ppm Range: ±0.06 ppm
3.0-6.0 ppm Range: ±0.4 ppm
6.0-10.0 ppm Range: ±1.5 ppm
Detection Limit 0.03 ppm Response Time <5 Seconds Light Source 525 nm LED, complies with Standard Methods 4500-Cl G
Range 0-1000 cu Detection Limit 20 cu Accuracy ±15 cu Light Source 428 LED
13
Page 14
SMART® Spectro Spectrophotometer
A spectrophotometer that is easy to use and more accurate than anything in its
Instrumentation
price range. With automatic wavelength selection, pre-programmed tests, and superior performance—this is the best spectrophotometer for the money!
Menu Driven Display
Tests and functions are selected from scrolling menus for ultimate simplicity. Results are displayed as %T, absorbance, and concentration.
Pre-Programmed Tests, User Tests & Automatic Wavelength Selection
Over 80 pre-programmed tests. Up to 25 calibrations for additional tests can be entered into the memory. The user can also customize sequences for frequently run tests. The meter automatically moves the grating to the required wavelength.
To Order:
Order Code 2000-01 (120V/60Hz and 220V/50Hz)
Includes 6 sample cells (25mm round), 2 sample cell holders (25mm round and COD, 10mm cuvettes), power supply, battery charger, and diagrammed manual.
Options:
 Carrying Case, Code 2000-CS  Battery Pack with holder (rechargeable), Code 2000-BP  SMARTLink 3 Software with cable, Code 1901-CD  Replacement sample cells (round), Code 0290-6  Cuvettes, Code 29653-10
See pages 17-18 for
complete reagent
system listing.
Wavelength Range: 350-1000 nm Wavelength Accuracy: ±2 nm Wavelength Resolution: 1 nm Wavelength Bandwidth: 5 nm (max) Photometric Range: 0-125%T, -0.1-2.5A Photometric Accuracy: ±0.005A Photometric Noise: <0.001A at 0A; <0.002A at 2A Photometric Drift: ±0.002A/hr @500 nm Photometric Stray Light: <0.5 %T Dispersive Device: Grating - based system Optical Mount: Modified Ebert Grating: 1200 grooves/mm ruled grating Light Source: Quartz halogen Bulb Life: 1000 hours minimum Sample Chambers: 25 mm round cell, 10 mm
square cuvette UDV, COD
Detector: Silicon photodiode Temperature Range: 0-40°C Modes: Conc., %T, ABS Pre-Programmed Tests: Yes Wavelength Selection: Automatic User Tests: Yes, up to 25 can be entered and
edited
Datalogging: Yes, RS-232, datalogs 500 tests Diagnostics: Yes Power: 110/220 volt or battery pack
(rechargeable)
Weight: 4.65 kgs (10.3 lbs) Size (WxDxH:) 35 cm x 28 cm x 17 cm
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com14
Page 15
SMART® Spectro Spectrophotometer
Digestion Tubes for Total Nitrogen and Total Phosphorus
LaMotte offers low and high Total Phosphorus and a Total Nitrogen test that are reacted in a heater block and are then tested using a colorimeter or spectrophotometer.
Code Description Range # of Tests
4024-01 Low Total Phosphorus 0-3.5 mg/L 25
4025-01 High Total Phosphorus 0-100 mg/L 25
4026-01 Total Nitrogen 0-25 mg/L 25
Instrumentation
Multi-Range COD Reagent Systems
LaMotte-manufactured Chemical Oxygen Demand reagent systems used with our SMART3 Colorimeter or SMART Spectro Spectrophotometer are an easy and precise way to measure critical COD levels. Measure low, medium or high levels of COD using your choice of mercury (US EPA approved method) or non-mercury reagent systems. Each package contains 25 ready to use vials. All kits ship as R1.
Mercury based systems
Code Range
0075-SC 0-150 ppm (EPA approved)
0076-SC 0-1500 ppm (EPA approved)
0077-SC 0-15,000 ppm
Mercury-free systems
Code Range
0072-SC 0-150 ppm
0073-SC 0-1500 ppm
0074-SC 0-15,000 ppm
COD Heater Block
Code 5-0102 (120V), 12-tube capacity Code 5-0102-EX2 (230V), 12-tube capacity
This COD heater block features digital microprocessor control, programmable time and temperature settings, and a dual LED display to monitor both temperature and timer. Perfect for COD, Total Phosphorus, and Total Nitrogen testing PLUS other tests requiring digestion.
Temperature: 30-200°C Timer: 0-999 minutes Vial Capacity: 12 (16 mm tubes) Stability: ±0.1°C@100°C Weight: 3.6 kg Dimensions 310 x 250 x 80mm (LxWxH) CE Mark: Yes Oven Temp Cutoff: 212°C
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com 15
Page 16
UV/VIS Spectrophotometer
Instrumentation
80+ Test Factors including: ALUMINUM AMMONIA CADMIUM CHROMIUM COBALT COD LR COD HR COPPER CYANIDE FLUORIDE IRON LEAD MANGANESE LR MANGANESE HR NICKEL NITRATE NITRITE PHENOL PHOSPHATE SULFATE ZINC
The UV-Vis Spectrophotometer is an ex­pandable, easy-to-use instrument that provides maximum performance in a compact, benchtop package. The instru­ment includes a high precision optical bench, full programming capabilities, customizable standard curves, and over 80 preprogrammed tests. Available options include a variety of sample holders as well as software-based wavelength scanning and kinetics.
Order Code 7-2000-UV
 Programmable wide range spectrophotometer can accept up
to 200 user curves in memory
 Pre-programmed to analyze selected tests on a direct-reading
digital display
 Advanced key pad with 22 buttons simplifies data entry  Includes one 10 mm quartz glass cuvette, six round 25 mm
10 mL test vials, universal sample holder and square sample holder
Wavelength Range 190-1100nm
Wavelength Accuracy ±2nm
Wavelength Repeatability ±1nm
Bandwidth 4nm
Optical System Single beam, grating 1200 lines/nm
Photometric Accuracy ±0.004 A at 0.5 A
Communication Ports USB, RS-232
Power Requirements 100-220V
Instrument Weight & Size 14kg (31 lbs.), 73x60x34cm (26x21x15”)
Shipping Weights & Size 17.5kg (39 lbs.), 104x82x60cm (26x21x15”)
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com16
Page 17
Instrument Reagent Listing
New tests are being developed for the SMART 3. Please contact our Technical Service Department for information regarding additions.
Instrumentation
Test Factor Test Method (# of reagents) SMART 3 Range†
Alkalinity UDV Unit Dose Vial (1) 10-250 15-200 100 4318-J NH
Aluminum Eriochrome Cyanine R (4) 0.01-0.30 0.01-0.30 50 3641-01-SC NH
Ammonia Nitrogen LR, Fresh Salicylate (3) 0.05-1.00 0.02-1.00 25 3659-01-SC R2
Ammonia Nitrogen LR, Salt Salicylate (3) 0.10-1.00 0.10-1.00 25 3659-01-SC R2
Ammonia Nitrogen HR Nesslerization (2) 0.05-4.00 0.05-4.00 50 3642-SC R1
Barium Barium Chloride (1) 5-200 50 3638-SC NH
Benzotriazole** UV Photolysis (3) 0.5-30.0 50 4047-01 R1
Biguanide Colorimetric (1) 2-70 5-70 50 4044 NH
Borate UDV Unit Dose Vial (1) 5-80 100 4322-J NH
Boron Azomethine-H (2) 0.05-0.80 0.05-0.80 50 4868-01 NH
Bromine LR DPD Tablets (2) 0.10-9.00 0.04-9.00 100 3643-SC NH
Bromine UDV Unit Dose Vial DPD (1) 0.1-22.0 0.3-22.0 100 4311-J NH
Cadmium PAN (4) 0.02-1.00 0.02-1.00 50 4017-01 R1
Carbohydrazide Iron Reduction (3) 0.04-0.900 0.005-0.900 100 4857 R1
Chloride TesTab Argentometric (1) 0.4-30.0 0.5-30.0 50 3693-SC NH
Chlorine (Free & Total) DPD Tablets (3) 0.03-4.00 0.02-4.00 100 3643-SC NH
Chlorine - Free UDV Unit Dose Vial (1) 0.10-10.00 0.10-10.00 100 4311-J NH
Chlorine - Liquid DPD DPD (3) 0.03-4.00 0.30-4.00 144 4859 R1
Chlorine - Total UDV Unit Dose Vial (1) 0.10-10.00 0.1-10.0 100 4312-J NH
Chlorine Dioxide DPD Tablet/Glycine (2) 0.06-8.00 0.04-7.00 50 3644-SC NH
Chromium Hexavalent Diphenylcarbohydrazide (1) 0.01-1.00 0.01-1.00 50 3645-SC HA
Chromium (Total, Hex & Trivalent) Diphenylcarbohydrazide (5) 0.01-1.00 0.03-1.00 50 3698-SC HF
Cobalt PAN (3) 0.04-2.00 0.02-2.00 50 4851-01 LQ
COD LR w/ Mercury* Digestion (1) 5-150 mg/L 5-150 mg/L 25 0075-SC R1
COD LR w/o Mercury* Digestion (1) 5-150 mg/L 5-150 mg/L 25 0072-SC R1
COD SR w/ Mercury* Digestion (1) 50-1,500 mg/L 50-1,500 mg/L 25 0076-SC R1
COD SR w/o Mercury* Digestion (1) 50-1,500 mg/L 500-1,500 mg/L 25 0073-SC R1
COD HR w/ Mercury* Digestion (1) 500-15,000 mg/L 500-15,000 mg/L 25 0077-SC R1
COD HR w/o Mercury* Digestion (1) 500-15,000 mg/L 50-15,000 mg/L 25 0074-SC R1
Color Platinum Cobalt (0) 20-1,000 15-1,000
Copper, BCA Bicinchoninic Acid (1) 0.04-3.50 0.05-3.50 50 3640-SC NH
Copper, Cuprizone Cuprizone (2) 0.03-2.00 0.01-2.00 50 4023 R1
Copper, DDC Diethyldithiocarbamate (1) 0.10-6.00 0.05-6.00 50 3646-SC NH
Copper UDV Unit Dose Vial, Bicinchoninic Acid (1) 0.1-4.0 0.20-4.00 100 4314-J NH
Cyanide Pyridine-Barbituric Acid (5) 0.03-0.35 0.05-0.50 50 3660-01-SC R1
Cyanuric Acid Melamine (1) 10-200 16-200 100 3661-01-SC R1
Cyanuric Acid UDV Unit Dose Vial, Melamine (1) 10-150 5-150 100 4313-J NH
DEHA Iron Reduction (3) 0.01-0.70 0.005-0.700 100 4857 NH
Dissolved Oxygen (DO) Winkler Colorimetric (3) 0.6-11.0 0.3-12.0 100 3688-SC R1
Erythorbic Acid Iron Reduction (3) 0.02-3.00 0.02-3.00 100 4857 R1
Fluoride SPADNS (2) 0.1-2.0 0.1-2.0 50 3647-02-SC R1
Hardness (Total) UDV UDV (1) 10-500 10-500 100 4309-J NH
Hydrazine P-dimethylaminobenzaldehyde (2) 0.01-1.00 0.010-0.750 50 3656-01-SC R2
Hydrogen Peroxide LR DPD (2) 0.02-1.50 0.02-1.50 100 3662-SC NH
Hydrogen Peroxide HR DPD (2) 1-60 1-60 50 4045-01 NH
†As ppm except as otherwise indicated *Requires COD Adapter Code 5-0087 and Heater Block **UV lamp 31041-1; UV lamp power source 31041-2; UV safety goggles 31041
Spectro / UV-VIS Range† # Tests Code Ship
NA NH
Continue next page...
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
17
Page 18
Instrument Reagent Listing
Test Factor Test Method (# of reagents) SMART 3 Range†
Hydrogen Peroxide Shock DPD (2) 10-225 4-225 100 4045-01 NH
Hydroquinone Iron Reduction (3) 0.01-2.00 0.01-1.80 100 4857 R1
Instrumentation
Iodine DPD Tablets (2) 0.2-14.0 0.08-14.00 100 3643-SC NH
Iron Bipyridyl (2) 0.10-6.00 0.06-6.00 50 3648-SC R1
Iron UDV Unit Dose Vial, Bipyridyl (1) 0.1-10.0 0.07-10.00 100 4315-J NH
Iron, Phenanthroline 1,10 Phenanthroline (2) 0.1-5.0 0.04-4.50 50 3668-SC R1
Lead PAR (5) 0.1-5.0 0.1-5.0 50 4031-01 R1
Manganese LR PAN (3) 0.01-0.70 0.02-0.70 50 3658-01-SC HF
Manganese HR Periodate (2) 0.3-15.0 0.3-15.0 50 3669-SC R1
Mercury TMK (3) 0.01-1.50 0.02-1.50 50 4861-01 LQ
Methylethylketoxime Iron Reduction (3) 0.01-3.00 0.02-3.00 100 4857 R1
Molybdenum HR Thioglycolate (3) 0.6-50.0 0.2-15.0 50 3699-03-SC R1
Nickel Dimethylglyoxime (6) 0.15-8.00 0.06-8.00 50 3663-01-SC LQ
Nitrate Nitrogen LR Cadmium Reduction (2) 0.10-3.00 0.05-3.00 20 3649-SC R1
Nitrate TesTabs Zinc Reduction (1) 5-60 3-60 50 3689-SC NH
Nitrate UDV Unit Dose Vial, Zinc Reduction 2-80 100 4321-J NH
Nitrite Nitrogen LR Diazotization (2) 0.02-0.80 0.020-0.800 20 3650-SC NH
Nitrogen, Total* Chromotropic Acid/Digestion (6) 3-25 mg/L 2-25 mg/L 25 4026-01 R1
Oxygen Scavengers Iron Reduction (3) various various 100 4857 R1
Ozone DPD (3) 0.03-3.00 100 4881 R1
Ozone LR Indigo Trisulfonate (3) 0.01-0.40 0.02-0.40 100 3651-SC NH
Ozone HR Indigo Trisulfonate (3) 0.05-2.50 0.05-1.50 20 3651-SC NH
pH, CPR Chlorophenol Red (3) 5.0-6.8 pH 5.0-7.0 pH 100 3700-01-SC NH
pH, PR Phenol Red (3) 6.6-8.4 pH 6.8-8.4 pH 100 3700-01-SC NH
pH, TB Thymol Blue (3) 8.0-9.5 pH 8.0-9.5 pH 100 3700-01-SC NH
Phenol Aminoantipyrine (3) 0.05-6.00 0.05-6.00 50 3652-01-SC NH
Phosphate LR Ascorbic Acid Reduction (2) 0.05-3.00 0.04-3.00 50 3653-SC R2
Phosphate HR Vanodomolybdophosphoric Acid (1) 0.5-70.0 1.0-70.0 50 3655-SC R1
Phosphate, ppb Ascorbic Acid/Digestion (2) 50-3000 ppb 50 3653-SC R2
Phosphorus, Total - LR* Ascorbic Acid/Digestion (5) 0.50-3.50 mg/L 0.07-3.50 mg/L 25 4024-01 R1
Phosphorus, Total - HR* Molybdovanadate/Digestion (5) 5-100 mg/L 5.0-100.0 mg/L 25 4025-01 R1
Potassium Tetraphenylboron (2) 0.8-10.0 0.5-10.0 100 3639-SC R1
Silica LR Heteropoly Blue (4) 0.05-4.00 0.03-2.50 100 3664-SC R1
Silica HR Silicomolybdate (3) 1-75 1-50 50 3687-SC R1
Sulfate HR Barium Chloride (1) 3-100 5-100 100 3665-SC R1
Sulfide LR Methylene Blue (3) 0.06-1.50 0.02-1.00 50 3654-02-SC R1
Surfactants Bromphenol Blue (3) 0.5-8.0 0.5-8.0 100 4876-01 LQ
Tannin Tungsto-Molybdophosphoric Acid (3) 0.1-10.0 0.2-10.0 50 3666-01-SC R1
Tolyltriazole** UV Oxidation/Dichromate (3) 0.5-30.0 50 4047-01 R1
Turbidity Absorptimetric (0) 3-400 FAU 2-400 FTU
Zinc LR Zincon (6) 0.05-3.00 0.03-3.00 50 3667-01-SC LQ
Spectro / UV-VIS Range† # Tests Code Ship
NA NH
18
† As ppm except as otherwise indicated * Requires COD Adapter Code 5-0087 and Heater Block ** UV lamp 31041-1; UV lamp power source 31041-2; UV safety goggles 31041
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
Page 19
Model 1200 • Single Test Colorimeter Labs
The 1200 Series of single test, direct reading colorimeters incorporates design advances that enhance reliability, improve accuracy, and simplify the calibration process, all in a portable, hand-held package.
Instrumentation
Options:
RS-232 Cable (Order Code 1772) AC Adapter 110/220V (Order Code 1754) Replacement Tubes (Order Code 0290-6)
AUTO-ZERO
Simply insert the sample blank and press the zero key.
HINGED LIGHT COVER
Flip-top lid over sample chamber prevents any stray light, especially in the field, and avoids misplacing separate light caps.
IMPROVED ACCURACY
The microprocessor enables the factory pro­grammed calibrations to optimally match non­linear curves.
EUROPEAN CE MARK
The 1200 has been independently tested and has earned the European CE Mark of compli­ance for electromagnetic compatibility and safety.
WATER RESISTANT DESIGN
Designed with excessive exposure to moisture in mind, the 1200 colorimeters deliver trouble­free performace in the field and lab.
EPA COMPLIANT
Employing the proper wavelength and the DPD test method, the 1200 Chlorine Colorimeter Kit meets or exceeds EPA design specifications for NPDWR and NPDES chlorine monitoring programs (EPA 330.5 and Standard Methods 4500-Cl G).
A GREAT VALUE!
Complete, economical package! The 1200 Chlorine Colorimeter Kit comes with enough tablets for 100 tests or liquid reagents for 140 tests, six sample vials with screw caps, instruction manual, and sturdy coloring case.
Instrument Type: Single wavelength,
direct-reading
colorimeter Readout: 3½ digit LCD Photometric Accuracy: ±0.001 Absorbance Unit
Detector: Silicon Photodiode Sample Chamber: Accepts 25mm diameter
flat-bottom, screwcap
tubes (6 included) Light Source: LED Interface: RS-232 serial interface Power: Alkaline 9-volt DC battery,
3.5 mm jack for optional
AC adapter Size (LxWxH): 15 x 8 x 5.5 cm,
6 x 3.25 x 2.5 inches,
152 x 83 x 64 mm
FIELD & LAB USE
An optional AC adapter is available to save bat tery life when in the laboratory.
0-4 PPM CHLORINE
No need to select a low or high range. The 1200 covers the entire critical chlorine range of 0-4 ppm with a 0.05 sensitivity.
RS-232 INTERFACE
An RS-232 port is provided to interface with a datalogger or computer. Optional cable avail­able.
LARGE DISPLAY
The large 3½ digit display presents measure­ments in absorbance, and indicates low bat­tery warnings.
-
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
19
Page 20
Model 1200 • Single Test Colorimeter Labs
Test Factor
Code
Model
Range (ppm)
Detection
Limit
Test Method (# of reagents)
Ammonia Nitrogen 3680-01 DC1200-NH 0–5.0 0.05 Nessler (2) 60 R1 Bromine 3672-01 DC1200-BR 0–7.0 0.05 DPD Tablets (1) 100 NH Chlorine (Free & Total) 3670-01 DC1200-CL 0–4.0 0.05 DPD Tablets (2) 100 NH
Instrumentation
Chlorine (Free & Total) 3670-01-LI DC1200-CL-LI 0–4.0 0.05 DPD Liquid (3) 140 R1 Chlorine Dioxide 3671-01 DC1200-CLO 0–7.0 0.05 DPD with Glycine Solution (2) 100 NH Copper 3673-01 DC1200-CO 0–6.0 0.03 Diethyldithiocarbamate (1) 100 NH Fluoride 3674-01 DC1200-FL 0–2.0 0.028 Alizarin-Zirconyl (2) 100 LQ Iron 3681-01 DC1200-FE 0–4.0 0.25 1,10 Phenanthroline (2) 100 R1 Manganese 3682-01 DC1200-MN 0–0.7 0.02 PAN (3) 100 R3 Molybdenum 3676-01 DC1200-MO 0–30 0.5 Thioglycolate (3) 50 R3 Nitrate Nitrogen 3677-01 DC1200-NA 0–3.0 0.05 Cadmium Reduction (2) 40 R1 Ozone 3678-01 DC1200-OZ 0–0.4 0.04 Indigo Blue (3) 100 NH
(Without other oxidizers) 3598 DC1200-OZ-DPD 0-3 0.03 DPD Liquid 140 R1
Ozone Phosphate 3679-01 DC1200-PLR 0–3.0 0.07 Ascorbic Acid (2) 100 R2 Sulfate 3683-01 DC1200-SU 0–100 1.0 Barium Chloride (1) 100 R1
Replacement Reagents for 1200 Chlorine
Liquid Reagents
30 mL (1 oz.)
DPD 1A P-6740-G NH DPD 1A P-6740-H NH DPD 1B P-6741-G R2 DPD 1B P-6741-H R2 DPD 3 P-6743-G NH DPD 3 P-6743-H NH
Tablet Reagents
Tablet
Chlorine DPD #1 Instrument* 6903A-H 6903A-J 6903A-M NH Chlorine DPD #3 Instrument* 6197A-H 6197A-J 6197A-M NH Chlorine DPD #4 Instrument* 6906A-H 6906A-J 6906A-M NH
* Instrument DPD featuring new ultra-clear fast dissolving tablets.
Code
Ship
Code
50
60 mL (2 oz.)
100
Code
1000
Ship
Code
Ship
Code
# of
Tests
Ship
Codes
20
DPD Powder Pop® Dispenser
LaMotte now offers the Powder Pop Dispenser – a hand held, single-dose dispenser for 10 mL samples that delivers a precise pre-measured dose of DPD reagent directly to your sample. Each Powder Pop kit includes enough reagent for 400 tests.
To Order:
Free Chlorine Powder Pop Dispenser (Order Code 3-0032) Total Chlorine Powder Pop Dispenser (Order Code 3-0033)
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
Page 21
Model 1200 & 1200 UDV • Absorbance Colorimeters
Model 1200 & 1200 UDV • Absorbance Colorimeters
The versatile 1200 Series of single wavelength colorimeters now comes with the capability to display readings directly in absorbance units. Six different wavelengths are available, with two sample vial options, to provide maximum flexibility for your analytical procedures. Microprocessor control and advanced design assure accuracy, easy operation, and durability.
Absorbance colorimeter kits are supplied with vials or cuvettes, water sample collecting bottle, 3 mL syringe (1200-UDV only), all in a sturdy carrying case.
Instrumentation
Model 1200 Meter
For 25mm vials
Order Codes
Listed by wavelengths:
3627-420
3627-510
3627-530
3627-562
3627-570
3627-605
Model 1200-UDV Meter
For 10mm cuvettes
Order Codes
Listed by wavelengths:
3627-420-UDV
3627-460-UDV
3627-510-UDV
3627-530-UDV
3627-562-UDV
3627-570-UDV
3627-605-UDV
Instrument Type: Single wavelength, absorbance
Measurement Wavelengths:
Readable Resolution: 0.01 Absorbance Unit Photometric Precision: ±0.001 Absorbance Unit
Range: 0-2.00 Absorbance Units Display: 3½ digit LCD Response Time: 2 seconds Detector: Silicon Photodiode Sample Chamber: Meters are available with one
Light Source: LED Interface: RS-232 serial interface, 8 pin
Power: Battery Operation: Alkaline
colorimeter 420nm, 460nm, 510nm,
530nm, 562nm, 570nm, or 605nm
of two chambers to accept 25mm flat-bottomed glass vials (1200) or 10 mm square polystyrene cuvettes (1200­UDV)
mDIN, 9600b, 8 data bits, 1 stop bit, no parity
9-volt DC battery; Line Operation: 230V/50Hz with adapter
120V/60Hz,
Chlorine Standards for Model 1200 & SMART3
For use with the 1200 series and SMART3 chlorine colorimeters. Secondary standards provide a fast way to check calibration without the burden of making primary standards. Based on Standard Methods for the Examination of Water and Wastewater, the operator can calibrate a colorimeter using a per­manganate primary standard or a chlorine primary standard. Once the meter is calibrated using the primary standard, the operator can insert secondary standards periodically to evaluate the calibration of the instrument.
 Secondary standard kit contains a blank and 3 standards for low, mid-range, and high chlorine
calibrations.
 Packaged in a small plastic case with Certificate of Analysis stating range of each standard.
To Order:
DPD Chlorine Secondary Standards, Order Code 4140-02 FAS-DPD Titration Kit for Chlorine Titration, Order Code 3176-02 Standard Chlorine Solution, 250 ppm, Order Code 6973-H (60 mL), Order Code 6973-L (475 mL) Permanganate Solution, 1000 ppm, Order Code 3858-H (60 mL)
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
21
Page 22
TRACER PockeTesters
The world’s first pocket-sized ISE meter for measuring total chlorine. Use it to test pH and ORP with interchangeable flat surface sensors.
Total Chlorine TRACER
Instrumentation
Order Code 1740
Read Total Chlorine from 0.00-10 ppm
 Readings are not affected by sample color or turbidity  Automatic self calibration; extra bold display includes an analog bar graph feature; memory can store
up to 15 readings
 Chlorine and pH modes also display sample temperature  Unit identifies which probe is in use and retains calibrations  Automatic shut-off and Low Battery indicator; uses four 3V CR-2032 batteries
 Includes 100 reagent tablets at almost half the price of
similar Chlorine ISE reagents
 Follows EPA protocol for ISE methods
TRACER KIT with pH, Total Chlorine and ORP probes
Order Code 1740-KIT-01
Includes Tracer meter with pH, Total Chlorine and ORP probes, 100 Chlorine tablets, 50 pH 7.0 buffer tablets, tablet crusher and convenient carrying case.
1740-KIT-01
pH TRACER
Order Code 1741
Provided with 4, 7, and 10 pH buffer tablets.
 Rugged flat surface electrode will alert user when it’s time to “RENEW”  A “CAL” indicator shows when to recalibrate and user can select a 1, 2, or 3 point calibration  Includes Automatic Temperature Compensation and displays temperature while showing pH result
Range: 0.00 to 14.00 pH Temp: 32° to 149°F (0° to 65°C) Resolution: 0.01 pH Accuracy: ±0.01 pH
TRACER with pH and Total Chlorine probes
Order Code 1741-KIT-01
Includes Tracer with pH and Total Chlorine probe, 100 Chlorine tablets, 50 pH tablets, tablet crusher in a convenient carrying case.
ORP TRACER
Order Code 1742
 High resolution to 1 mV  Automatic self calibration
Range: -999 to 999 mV Resolution: 1 mV Accuracy: ±4 mV
TRACER KIT
with pH and ORP probes
Order Code 1742-KIT-01
Includes Tracer with pH and ORP probe, 100 Chlorine tablets, 50 pH tablets, tablet crusher in a conve­nient carrying case.
OPTIONS
Additional Probes
Order Code 1733 pH Sensor (0-14.00/±0.01 pH) Order Code 1734 ORP Sensor (±999mV/±4mV) Order Code 1732 Cl2 Sensor (0-10.00/±10% of reading)
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com22
Chlorine Test Tablets
Order Code 7044A-J
Specially formulated just for the TRACER, these deliver a precise amount of iodide for a 20 mL sample. Available in packages of 100.
Page 23
TRACER PockeTesters
Instrumentation
EC/TDS/SALT TRACER
Code 1749
 Easy to use  2% accuracy for EC, TDS, and Salt modules  Automatic temperature compensation  Self calibration  Memory can store up to 25 readings; auto-
power off after 10 minutes of no button presses
 Automatic shut-off and low battery indicator;
uses four 3V CR-2032 button batteries
Options:
EC/TDS/SAL Replacement Electrode*, Order Code 1765
Sample Cup w/cap, Order Code 1745-1
Conductivity Standard, 84 µS, Order Code 6312-G
Conductivity Standard, 1413 µS, Order Code 6354-J
Conductivity Standard, 12,880 µS, Order Code 6317-G
Conductivity: 0 to 199.9 µS, 200 to 1999 µS,
2.00 to 19.99 mS
TDS: 0 to 9,999 ppm Salinity: 0 to 9,999 ppm Temperature 32°F to 149°F (0 to 65°C) Accuracy: EC, TDS, Salt: ± 2% FS;
Temperature: ± 1°C (1.8°F)
*Not interchangeable with Cl/pH/ORP TRACER
Fluoride TRACER
Order Code 1756
 The first Fluoride meter with built-in
Automatic Temperature Compensation and fastest response (<1 min)
 Small sample/TISAB volume required for testing  Complies with EPA Method 340.2
(Potentiometric Ion Selective Electrode)
 Automatic electronic 1 or 2 point calibration
with offset adjustment
 Memory stores 25 labeled readings and
water resistant to IP54
 Complete with electrode, 20 TISAB reagent tablets,
sensor cap, four 3V button batteries, and 48” (1.2m) neckstrap
Fluoride TRACER KIT
Order Code 1756-KIT-01
 Includes Tracer meter with 4 oz. bottle of 1 ppm
Fluoride Standard and convenient carrying case.
Options:
TISAB Reagent, 100 Tablets, Order Code 7024-J
Replacement Electrode, Order Code 1757
Fluoride Standard, 1 ppm, 1000 mL, Order Code 2798-M
Fluoride Standard, 1,000 ppm, 60 mL, Order Code 4154-H
Fluoride Standard, 1,000 ppm, 500 mL, Order Code 4154-L
Fluoride: 0.1 to 10 ppm, max. resolution: 0.1 ppm, accuracy:
±3% rdg
Temperature 32°F to 140°F (0 to 60°C), max. resolution: 0.1 °F,
accuracy: ±1.8°F/1°C
Accuracy: EC, TDS, Salt: ± 2% FS; Temperature: ± 1°C (1.8°F)
pH/TDS/SALT
Code 1766
Measures five parameters including Conductivity, TDS,
Salinity, pH, and Temperature using one electrode
Units of measure: pH, µS, mS, ppm, ppt, mg/L, g/L, °C, °F Memory stores up to 25 labeled readings; auto power off and
low battery indicator
Adjustable Conductivity to TDS ratio
Range Resolution Accuracy
Conductivity 0 to 199.9 µS, 200 to 1999 µS, 2.00 to 19.99 mS 0.1 µS ±1% TDS/Salinity 0 to 99.9 ppm (mg/L), 100 to 999 ppm (mg/L), 1.00 to 9.99 ppt 0.1 ppm (mg/L) ±2% pH 0.00 to 14.00 pH 0.01 pH ±0.01 pH Temperature 32° to 149°F (0 to 65°C) 0.1°F/°C ±1.8°F/°C
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
See pages 32
for pH Tablets
Options:
pH/EC/TDS/SAL Replacement Electrode*, Order Code 1755
Sample Cups w/cap, Order Code 1745-1
Conductivity Standard, 84 µS, Order Code 6312-G
Conductivity Standard, 1413 µS, Order Code 6354-G
Conductivity Standard, 12,880 µS, Order Code 6317-G
23
Page 24
Dissolved Oxygen Meters
Dissolved Oxygen Tracer
Order Code 1761
Instrumentation
 Oxygen level displayed as % Saturation from 0 to 200.0% or Concentration from 0 to 20.00 ppm (mg/L)  Adjustable Altitude Compensation (0-20,000 ft in 1,000 ft increments)  Adjustable Salinity Compensation from 0 to 50 ppt  Memory stores up to 25 data sets with DO and Temperature reading  Self-calibration on power up; Data, Hold, Auto power off, Low battery indicator  Waterproof to IP67  Optional 3 ft (1m) or 16 ft (5m) extension cable; complete with DO electrode, protective sensor cap, spare membrane
cap, electrolyte, four 1.5V CR-2032 batteries, and 48” (1.2m) neckstrap
Range Resolution Accuracy
DO (sat. mode) 0 to 200.0% 0.1% ±2% FS DO (conc. mode) 0 to 20.00 ppm (mg/L) 0.01 ppm (mg/L) 0.4 ppm (mg/L) Temp. 32 to 122°F (0 to 50°C) 0.1°F/°C ±1.8°F (1°C) Dimensions 1.4x6.9x1.6” (36x176x41mm) Weight 3.8 oz (110g)
Dissolved Oxygen Meter
Order Code 5-0107-01
 No meter warm-up required  Low-maintenance probe  Key in salinity and pressure values manually  Independent 100% and zero adjustment calibrations  Offset adjustment capabilities  Displays electrode diagnostics  Easily toggle from
mg/L (ppm) or % saturation to temperature mode
Accessories
 DO Membrane Kit, 6 screw-on
membranes and solution (Order Code 1761M)
 DO Sensor Module
(Order Code 1762)
 3 ft. Cable (Order Code 1763)  16 ft. Cable (Order Code 1764)
Range Resolution Accuracy
mg/L (ppm) 0.00 to 20.00 mg/L
% Saturation 0.0 to 200.0% 0.1% ±1.5% FS Temp. -5.0 to 105.0°C 0.1°C ±0.5°F Salinity correction 0.0 to 50.0 ppt 0.1 ppt Method: Key
Barometric pressure correction
Temperature compensation
Operating temperature 0 to 50°C Probe Galvanic, 3 ft. probe cable Power Four 1.5 V AAA batteries (included), >700 hrs
Dimensions 5.5”L x 2.7”W x 1.3”H Weight 1.0 lb (0.45 kg)
(ppm)
500 to 1499 mm Hg 1 mm Hg Method: Key
Automatic from 0 to 50°C
continuous use
0.01 mg/L (ppm)
±1.5% FS
in manually or automatic correction
in manually or automatic correction
24
Accessories
 Replacement Probe (Order Code 5-0129)  Replacement Membrane Package including electrolyte solution
(Order Code 5-0137)
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
Page 25
PockeTesters
PAGE
pH PockeTester 10
Order Code 5-0103
 ±0.1 pH accuracy
pH PockeTester 20
Order Code 5-0104
 ±0.01 pH accuracy
Both meters feature automatic temperature compensation, and buffer recognition for three point calibration based on US (pH 4.01, 7.00, 10.01) or NIST (pH 4.01, 6.86, 9.18) systems. The sensor is a double junction Ag/AgCl system with polymer gel. The IP67 rated housing features a 1.0625” (26.99 mm) display, which also displays diagnostic messages. Auto-off after 8.5 minutes to conserve battery life.
(Replacement Electrode, Code 5-0097)
(Replacement Electrode, Code 5-0097)
Instrumentation
Double Junction ORP PockeTester
Order Code 5-0079
 –999 mV to +1000 mV  Large surface area platinum band sensor  1 mV resolution, 2 mV accuracy  HOLD function, Auto-off
for complete PockeTester specs
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com 25
Page 26
PockeTesters
Instrumentation
Code 5-0080
Microprocessor-Based TDS Dual Range PockeTester
Order Code 5-0080
0-2000 ppm (10 ppm resolution) ; 0-10.00
ppt (0.10 ppt resolution)
 ±1% full-scale accuracy  Automatic temperature compensation (ATC)  Replacement electrode  Push-button calibration  Auto shut-off  Full reading displayed – no need to multiply
Replacement Probe (Order Code 5-0084)
Code 5-0078 Code 5-0082
Salt PockeTester
Order Code 5-0078-01
 0–10 ppt ( 0.10 ppt resolution)  Carrying Case and calibration standard
included
Replacement Probe (Order Code 5-0084)
Microprocessor-Based EC Conductivity Dual Range PockeTester
Order Code 5-0082
 0-2000 µS (10 µS resolution); 0-20.00 mS
(0.10 mS resolution)
 ±1% full-scale accuracy  Automatic temperature compensation (ATC)  Replacement electrode  Push-button calibration  Auto shut-off  Full reading displayed – no need to multiply
Replacement Probe (Order Code 5-0084)
26
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
Page 27
PockeTester Specifications
Specifications for pH PockeTesters Specifications for Specialty PockeTesters Model pH PockeTester 10 pH PockeTester 20 Min-Max Thermometer ORP PockeTester Salt Code 5-0103 5-0104 5-0095 5-0079 5-0078-01 Range –1.0 to 15.0 pH; extended range –10 to 200°F,
Resolution 0.1 pH 0.01 pH 0.1°F to 199.9°,
Accuracy ±0.1 pH ±0.01 pH ±1.8°F / ±1.0°C ±2 mV ±10%
Calibration Select up to 3 points
Operating Temperature
Temperature Compensation
Special Functions
Power & Battery Life
(4.0, 7.0, 10.0 or 4.01, 6.86, 9.18)
32 to 122°F;
0 to 50°C
Automatic (ATC)
0 to 50°C
On/Off or Auto-Off after 8.5 min.; HOLD;
CALibrate; CONfirm
Four 1.5V alkaline button cell batteries
(supplied), 500 hour use
32 to 122°F;
0 to 50°C
14 to 392°C
1°C above 200°
Factory calibrated; fine
adjustment through
keypad
32 to 122°F;
0 to 50°C
Automatic(ATC)
On/Off or Auto-Off after
8.5 min.; HOLD; °F or °C
scale selectable; factory
calibration maintained
when batteries are
replaced
LR-44 button cell. 2 yr life Four 1.5V alkaline
–999 mV to +1000 mV 0-10.00 ppt salinity
1 mV 0.10 ppt salinity
full-scale
Offset calibration to
ORP standard or work
standard
32 to 122°F;
0 to 50°C
On/Off or Auto-Off after
8.5 min.; CALibrate;
CONfirm; HOLD (HO) and
HOLD/ CANCEL (HC)
batteries (supplied) 500
hrs. use
One-point with
trimpot
32 to 122°F;
0 to 50°C
0 to 50°C
Four 1.5V alkaline
batteries (supplied)
150 hrs. use
Instrumentation
Dimensions & Weight
Model TDS Dual Range EC Dual Range Code 5-0080 5-0082 Replacement Electrode 5-0084 5-0084 Range 0-2000 ppm/ 0-10 ppt 0-2000 µS; 0 to 20 mS Resolution 10 ppm/0.10 ppt 10 µS; 0.10 mS Accuracy ±1%FS Calibration One-point, push-button calibration using buttons inside battery compartment Operating Temp. 32 to 122°F; 0 to 50°C Temperature Comp. Automatic (ATC) 0 to 50°C Special Functions Full reading displayed Power & Battery Life Four 1.5V alkaline batteries (supplied); 150 hours Dimensions & Weight 8.5” (216 mm) L x 2.4” (61 mm) W x 2.5” (64 mm) H (boxed);
8.5” (216 mm) L x 2.4” (61 mm) W x 2.5” (64 mm) H (boxed); 6.5” (165 mm) L x 1.5” (38 mm) Dia. (unit only);
4.5 oz/125 gms (boxed); 3.25 oz./90 gms (unit only)
Memory Thermometer Probe: 4.3” (109 mm) x 0.14” (4 mm); top is 1.8” (46 mm); weight 3 oz
Specifications for TDS & EC Waterproof PockeTesters
6.5” (165 mm) L x 1.5 (38 mm)” Dia. (unit only);
4.5 oz./125 gms (boxed); 3.25 oz./90 gms (unit only)
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
27
Page 28
Temperature Measurement
Instrumentation
IR Meter with Color Alert System
Code 5-0133
Convenient non-contact temperature measurements, now with a laser sighting, plus color and sound alerts!
Features
 Fast and accurate measurements at 12” where the two lasers
converge with 12:1 field of view
 Measures up to 950°F (510°C) Blue backlit dual LCD display changes to Red backlit outside set
points
 Instantaneous response captures spikes in temperature  Max mode captures and holds rapidly changing temperatures  Lock function for continuous readings  Adjustable emissivity increases measurement accuracy for
different surfaces
 Double molded housing  Complete with case and 9V battery  Adjustable High/Low set points with color and audible alarms
signal out of range temperature
Blue backlight:
within temperature
range
Red backlight
plus audible
alert: exceeds
temperature
“Min-Max” Memory Thermometer
Order Code 5-0095
 Range: 14 – 392°F or -10 – 200°C  °F or °C selectable scale  Recalls minimum and maximum temperature
Range: -4 to 950°F (-20 to 510°C) Resolution: 1°C/1°F Accuracy: 25 to 260°C (77 to 500°F): ±(1% of rdg
+2°F/1°C)
Repeatability: ±0.5% or 1.8°F/1°C Response Time: 150mSec Emissivity: 0.10 to 1.00 adjustable Distance-to-Spot Size: 12:1 Power: One 9V alkaline battery Dimensions: 5.7 x 4 x 1.6 inches (146 x 104 x 43 mm) Weight: 5.74 oz. (163g)
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com28
Page 29
LaMotte pH, CON, TDS Meters
Instrumentation
Economical Field Meters
 Push button operation  Up to five point calibration  Temperature readout  Automatic Temperature Compensation  Auto-off after 17 minutes; Hold function  Buffer recognition (pH 5 meter)  Adjustable conductivity to TDS factor (TDS 6 meter)
Microprocessors have enabled meter manufacturers to combine many features into smaller designs with better accuracy. The 5 and 6 Series meters are good examples (see specifications below). All meters include electrodes and temperature probes, and are available with or without a carrying case.
 The pH 5 without case includes pH 4, 7 and 10 buffer tablets.  The pH 5 with case includes pH 4, 7 and 10 buffer liquids.  The TDS 6 and Con 6 with carrying cases include two calibration standards.  All meters have two-year warranties.
Model Order Code w/out case 5-0034-01
Replacement Probe
Range: 0.00 to 14.00 pH 0.0 to 100.0°C 0.0 to 20.00,
Resolution: 0.01 pH 0.1°C 0.01, 0.1, 1 µS
Accuracy: ±0.01 pH ±0.5°C ±1% full scale or ±1 digit ±1% full scale ±0.5°C Calibration: Up to 5 Buffer Values Offset 0.1°C
Temperature Compensation:
Power: Four AAA alkaline batteries (supplied); >70
Display: Single Custom LCD Single Custom LCD Auto shut-off: After 17 minutes After 17 minutes Operating
Temperature:
with case 5-0035-01
Automatic Temperature Compensation (ATC) Automatic Temperature Compensation (ATC)
pH 5 (pH)
pH Probe
Order Code 1904
hours continuous use
32 to 122°F; 0 to 50°C 32 to 122°F; 0 to 50°C
Temperature Probe
Order Code 5-0041
pH 5
(Temperature)
w/out case 5-0038-02
with case 5-0039-02
0 to 20.00, 200.0 mS
up to 5 points (1 per range) for multi-point calibration;
increments
CON 6 Meter
(Conductivity)
w/out case 5-0036-02
with case 5-0037-02
CON/TDS Probe
Order Code 5-0106
200, 2,000.0 µS
0.01, 0.1 mS
or 1 point for single point for entire range
0.0 to 10.00, 100.0, 1000 ppm,
1.0 to 10.00, 100.0, 200 ppt
0.01, 0.1, 1.0 ppm
fixed 2% per °C factor, adjustable 73%
Four AA alkaline batteries (supplied)
>100 hours continuous use
TDS 6 Meter
(TDS)
0.01, 0.1 ppt
CON 6 & TDS 6
Meters
(Temperature)
-10.0 to 110.0°C
0.1°C
Offset 0.1°C
increments
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
29
Page 30
pHPLUS Direct Digital pH/ISE Meter
Instrumentation
pHPLUS DIRECT Meter
Laboratory precision in a water-resistant design! Read pH, mV/R.mV, temperature, and concentration with accuracy – ISEs read concentration in ppm. Easy­to-use in any test mode. Includes pH probe, temperature probe, buffers and rubber boot with stand.
Specifications
pH
Range: 0.00 to 14.00 Resolution: 0.01 Accuracy: 0.01 Calibration: Up to 5 points Electrode: Epoxy, Ag/AgCl Temperature
Range: 0 to 100°C Resolution: 0.1°C Accuracy: ±0.1°C Concentration
Range: 0.00 to 100 Resolution: ± LSD Accuracy: ±0.5% or ±1 LSD mV/R.mV
Range: ±500mV Accuracy: ±1 mV Resolution: 1 mV Calibration: Up to 5 points Inputs: 1 BNC, Temp probe, power, ref. pin
Power: 4 AAA batteries Size (LxWxH): 2.75W x 5.75H x 1.375D in.
Optional ISE Electrodes*
Although the pHPLUS Direct reads directly in ppm, an initial calibration is required. The standard solution, replacement electrolyte, ionic strength ad­justor and pipet are included in the Accessory Kit. The ammonia accesory kit also contains replacement membranes.
pHPLUS DIRECT Meter
Code Description
5-1936-01 pHPLUS DIRECT Meter, liquid buffers
(4, 7, 10) w/case 1904 pH Electrode, gel-filled 1909 Temperature Probe
Ion Selective Electrodes
Code Description
5-0043 Ammonia 5-0048 Fluoride 5-0052 Nitrate
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com30
Accessory Kits
Code Description
5-0098 Ammonia 5-0099 Fluoride 5-0100 Nitrate
*Accessory Kit required to calibrate the ISE.
Page 31
DPD TesTabs® Instrument Grade
LaMotte has developed a rapid dissolve instrument grade DPD tablet system. Instrumental analyses require a clear, particle-free testing solution. In the past, it was necessary to use a crusher to dissolve the instrument grade tablets. Now, free and total chlorine samples can be done with instrument grade tablets that dissolve without crushing.
DPD Reagents
Quantity/Order Code
Tablet
Chlorine DPD #1 Instrument*
Chlorine DPD #3 Instrument*
Chlorine DPD #4 Instrument*
* Instrument DPD featuring ultra-clear fast dissolving tablets.
See page 71 for Visual Tablets
50
6903A-H 6903A-J 6903A-M NH
6197A-H 6197A-J 6197A-M NH
6906A-H 6906A-J 6906A-M NH
100
1000
Instrumentation
Ship
Code
DPD Liquid Reagents
The liquid alternative to DPD tablets can be used with existing LaMotte chlorine comparators or colorimeters. DPD 1A and DPD 1B are added to a 5 or 10 mL sample to test Free Available Chlorine. DPD 3 is added to the reacted sample to measure Total Chlorine. Liquid reagents are also available to measure pH, Hardness, Alkalinity, and Copper.
30 mL (1 oz.) Code Ship Code
DPD 1A P-6740-G NH DPD 1B P-6741-G R2 DPD 3 P-6743-G NH
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com 31
60 mL (2 oz.) Code Ship Code
DPD 1A P-6740-H NH DPD 1B P-6741-H R2 DPD 3 P-6743-H NH
Page 32
pH Buffers/Electrode Soaker
Instrumentation
Standardized pH Buffer Solutions
For use in calibration of pH meters. Ordering information for all buffers is listed below.
pH Value Code
4.01 2866-J
2866-L
6.86 2808-L 500 mL
Note: Other pH values available
Size
120 mL 500 mL
pH Value Code
7.00 2881-J 2881-L
9.18 2809-L 120 mL
10.00 2896-J 2896-L
Size
120 mL 500 mL
120 mL 500 mL
Buffer Tablets
Add one tablet to 20 mL of Deionized Water to produce buffers. Available in 50 and 100 tablet packs. In foil strips of 10 tablets each.
pH Value Code
4.0 3983A-J-100
4.0 3983A-H-50
7.0 3984A-J-100
7.0 3984A-H-50
10.0 3985A-J-100
10.0 3985A-H-50
Color-Coded pH Buffer Solutions
Minute amount of color permits immediate visual distinction of different buffer values.
pH Value Code Color Size
4.01 3771-L Red 500 mL
7.00 3772-L Yellow 500 mL
10.0 3773-L Blue 500 mL
Electrode Soaker Bottle
Order Code 0668
Continuously soaks pH elec­trode in a storage solution to prevent probe dry out. Twist top “O” ring seal pre­vents leaks.
32
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
Page 33
Conductivity/TDS Solutions
The following potassium chloride solutions can be used to standardize conductivity meters. TDS values are based on a 0.7 conversion from conductivity.
Instrumentation
Conductivity Solutions
Code Description Size
6416-L 74 µS/cm, 52 ppm 500 mL 6312-L 84 µS/cm, 59 ppm 500 mL 6417-L 718 µS/cm, 503 ppm 500 mL 6354-L 1,413 µS/cm,989 ppm 500 mL 6418-L 6,668 µS/cm, 4668 ppm 500 mL 6317-L 12,880 µS/cm, 9016 ppm 500 mL 6419-L 58,640 µS/cm, 41,048 ppm 500 mL
Conductivity Neutralizing Solutions
Used to neutralize hydroxl ion in boiler water, thus enabling accurate determinaion of ionic conductivity.
Code Description
6483-H (60 mL) 6483-L (500 mL) 6483-N (3800 mL)
6479-J Gallic Acid
3705-L Acid Indicator Contains acetic acid and phenolphthalein.
Conductivity Neutralizing Solution
Powder
Contains citric acid and phenolphthalein. Add liquid until sample changes color. Available in 60 mL, pint, and gallon sizes.
Organic acid powder; indicator must be purchased and added separately. Add raw powder to sample containing indicator until color changes. Available in 100 g.
Add liquid until sample changes color. Available in 500 mL (pint).
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
33
Page 34
Convenient and Economical
Strips
®
LaMotte offers a convenient, economical way to perform spot checks for several water quality factors. LaMotte test strips are a great way to monitor water without having to use reagents or field kits. Strips are available for the factors below…and we’re working on more!
Single Factor Test Strips
Insta-Test
Test Factor
Alkalinity 2997 0-180 Drinking, Food/Beverage 50 0, 40, 80, 120, 180
Borate 3017-G 0-80 Pool 25 0, 15, 30, 50, 80
Chlorine Dioxide 2999LR 0-10 Drinking, Food/Beverage 50 0, 0.25, 0.5, 1, 3, 10
Chlorine Dioxide 3002 0-500 Medical, Food/Beverage 50 0, 10, 25, 50, 100, 250, 500
Chlorine, Free, Low Range 2964-G 0-10 Drinking, Food/Beverage, Medical 25 0, 0.5, 1, 3, 5, 10
Chlorine, Total, Low Range 2963LR-G 0-10 Drinking, Food/Beverage, Medical 25 0, 0.25, 0.5, 1, 3, 10
Chlorine, Total, Low Range 2963LR-J 0-10 Drinking, Food/Beverage, Medical 100 0, 0.25, 0.5, 1, 3, 10
Chlorine, Total, Low Range 2979 0-5 Drinking, Food/Beverage 50 0, 0.5, 1, 3, 5
Chlorine, Free & Total 3027-G 0-10 Drinking, Food/Beverage, Medical 25 0, 0.5, 1, 3, 5, 10
Chlorine, High Range 3031 0-800 Food/Beverage, Medical 50 0, 50, 100, 250, 500, 800
Copper 2991-G 0-3.0 Drinking, Pool 25 0, 0.3, 0.6, 1, 3
Hardness, Low Range 2981 0-180 Drinking, Food/Beverage 50 0, 30, 60, 120, 180
Iron 2935-G 0-5 Drinking, Pool 25 0, 0.3, 0.5, 1, 3, 5
Molybdenum Kit* 3628-01 0-5 Industrial 50 0, 0.5, 1, 2, 5
Nitrate 3012-G 0-200 Pool 25 0, 10, 30, 60, 120, 200
pH, Wide Range 2974 4-10 (pH) Drinking, Food/Beverage 50 4, 5, 6, 7, 8, 9, 10
Peracetic Acid 3000 0-160 Food/Beverage 50 0, 10, 20, 50, 85, 160
Peracetic Acid, Low Range 3000LR 0-50 Food/Beverage 50 0, 5, 10, 20, 30, 50
Peracetic Acid, High Range 3000HR 0-1000 Food/Beverage 50 0, 50, 100, 250, 500, 1000
Hydrogen Peroxide HR 2984 0-90 Pool 25 0, 15, 30, 50, 90
Hydrogen Peroxide 2984LR 0-50 Drinking, Food/Beverage 25 0, 1, 3, 10, 30, 30, 50
Phosphate, Low Range 3021 0-2500 ppb Pool 25/50 0, 100, 200, 300, 500, 1000, 2500 ppb
Phosphate, High Range 3040-G 3000-12000
QAC Dual Range 2934 0-80
Sodium Chloride 2998 1500-5000 Pool 10, 50 1500, 2000, 2500, 3000, 3500,
Code
Range (ppm)
ppb
0-800
Water Testing Application*
Pool 25 3000, 6000, 12000 ppb
Food/Beverage 50 Low: 0, 10, 20, 40, 80 ppm
# of Tests Per
Factor/Per Vial Values (ppm)
High: 0, 100, 200, 400, 800 ppm
4000, 5000
34
* Kit includes a pre-treatment reagent.
ACCURATE & RELIABLE Easiest test strips to read.
CONNECTED CAP Can’t fall into the water or be lost.
HINGE GUARANTEE Rated for 1000+ openings.
LEAKPROOF Airtight seal meets USDA and FDA requirements.
DESICCANT WALL Can’t fall onto wet hands.
6 GRAMS (NOT 3) Desiccant liner is double the industry standard
for moisture protection.
DOUBLE DUTY High-density outer shell, combined with desiccant liner, ensure less moisture and light.
HDPP PROTECTION High density polypropylene plastic protects better than common HDPE bottles.
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
Page 35
Accurate and Reliable
Insta-Test
Multi-Factor Test Strips
Test Factor Code Range
Copper, pH, & Alkalinity (sold only in case of 12)
Iron & Copper 2994 0-5 Iron
Iron, pH, Hardness, Total Chlorine
Wide Range (pH & Total Chlorine)
6-Way Drinking Water 2933-G 0-10 FCl
5-Way Natural Water Fresh & Salt Water
Nitrate & Nitrite 2996 0-50 (Nitrate)
3001-G 0-3 Copper
6.2-8.4 pH) 0-240 Alkalinity
0-3 Copper
2992 0-5 Iron
4-10 pH 0-400 Hard 0-10 TCl
2987-G 4-10 pH
0-50 TCl
0-10 TCl 0-400 Total Hardness (0-23 gpg Total Hardness) 4-10 pH 0-10 Nitrite 0-10 Nitrate
3038-G 0-200 Nitrate
0-10 Nitrite
6.0-9.0 pH 0-240 Alkalinity 0-180 Total Hardness
0-10 (Nitrite)
Water Testing
Application*
Pool 25
Drinking, Pool 25
Drinking,
Industrial Water
Features
Drinking, Pool,
Food/Beverage
Drinking 25 0, 0.5, 1, 3, 5, 10
Environmental,
Aquarium
Drinking 50
# of Tests
Per Factor/
Per Vial Values (ppm)
25 25
25
25 25 25 25
25 25
25 0, 20, 40, 80, 160, 200
50
0, 0.3, 0.6, 1, 3
6.2, 6.8, 7.2, 7.6, 8.0, 8.4 0, 40, 80, 120, 180, 240
0, 0.3, 0.5, 1, 3, 5 0, 0.3, 0.6, 1, 3
0, 0.3, 0.5, 1, 3, 5 4, 5, 6, 7, 8, 9, 10 0, 50, 100, 200, 400
4, 5, 6, 7, 8, 9, 10 0, 1, 5, 10, 20, 50
0, 0.5, 1, 3, 5, 10 0, 50, 100, 200, 400 (gpg: 0, 3, 5.8, 11.7, 23) 4, 5, 6, 7, 8, 9, 10 0, 0.5, 1, 5, 10 0, 5, 10, 25, 50
0, 0.5, 1, 3, 5, 10
6.0, 6.5, 7.0, 7.5, 8.0, 8.5, 9.0 0, 40, 80, 120, 180, 240 0, 30, 60, 120, 180
0, 5, 10, 25, 50 (NO3-N) 0, 0.5, 1, 5, 10 (NO2-N)
®
Strips
*Strips shown have been evaluated for use in these applications. Use in other applications is subject to potential interferences. Contact LaMotte Technical Services for more information.
Sanitizer Test Papers & Strips
Chemically treated paper strips change to indicate sanitizer level. Strips and color chart are packaged in a waterproof plastic vial. 2951 is specifically formulated to read all types of QAC.
Factor Order Code Range
Chlorine 4250-BJ 10, 50, 100, 200 ppm (200 papers)
Chlorine, Free, High Range
Iodine 2948-BJ 12, 25, 50, 100 ppm (200 papers)
QAC 2951 50, 100, 200, 400 ppm (100 strips)
QAC 3072-J 0, 100, 200, 300, 400, 500 ppm (100 strips)
QAC Dual Range Test Strips
High Range QAC 2951HR 200, 400, 600, 1000, 1500 ppm (50 strips)
For PERACETIC ACID Test Strips, see page 34.
3031 0, 50, 100, 250, 500, 800 ppm (50 strips)
2934 Low Range: 0, 10, 20, 40, 80
High Range: 0, 100, 200, 400, 800 (50 strips)
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
35
Page 36
Micro Testing Simplified!

Microbiological

BioPaddles®
 Ready to use. Saves time!  Longer shelf-life than traditional Petri dishes  No refrigeration required
BioPaddles® are flexible dual-agar paddles each containing microbe-specific media enclosed in a sterile vial. Identify and quantify microbes in air, soil, water, or any surface!
Liquid Sampling: Remove the paddle from the vial and fill the vial (approximately 40ml) with the sample. Insert the paddle, swirl for 15 seconds. Pour out the liquid, replace the paddle in the vial, and incubate.
Surface Sampling: Remove the paddle from the vial and gently touch each paddle media surface to the sample surface. Replace paddle in the vial and incubate.
Air Sampling: Remove the paddle from the vial. Invert and mount the circular cap into the vial, ex­posing the agar covered paddle. Expose for 15 minutes. Replace the paddle in the vial and incubate.
36
All BioPaddles® products come with a free app! LaMotte BioPaddles Colony ID™ App lets users compare colony examples on BioPaddle agar types from 5 microhabitats (air, water, soil, surface and food). Also contains information regarding organisms, microbiological techniques, and more!
For fresh, brackish, and salt water use.
BioPaddles® Products—all packaged 10 paddles per box. Includes general instructions and provides access to detailed Technical Documents for each paddle type.
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1, r1) Small Qty. Hazardous Material - No Fees • (Lq, LQ, R2, r2, R3, r3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
https://itunes.apple.com/ us/app/id567584998
Page 37
Bacteria & Coliform Testing Kit
Type Of Agar(s) Description Code
Nutrient For routine culture of non-fastidious bacteria. 5550
Sabouraud Dextrose
Tryptic Soy (TSA)/ Rose Bengal (RB)
Nutrient TTC/ MacConkey
For selective cultivation of fungi (yeasts and molds) 5551
For cultivation of a wide variety of microorganisms (TSA) and selective isolation of yeasts and molds (RB). 5552
TTC. For field sampling cultivation and enumeration of coliform bacteria total coliform count (TCC). Gram (-) bacterial colonies appear as red dots. Gram (+) bacteria are usually inhibited.
MAC. Medium gives improved differentiation between coliforms and non-lactose fermenting organisms. Gram (+) cocci are usually inhibited.
5553
Microbiological
Coliform Screening Test
The 4-3616 is an easy-to-use, disposable 5-tube method to indicate the presence of Total Coliform Bacteria in a water supply. The water sample is placed in test vials containing the special coliform indicating tablets and stored at room temperature for a prede­termined time period. After the required storage period, the vials are examined to determine the presence of coliform bacteria.
Code Test System
4-3616 Tableted nutrient
based on 5 tube MPN
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
Range/Sensitivity # of Tests
(# of Reagents)
Presence/Absence 1 (1) NH (1)
Shipping Code
(Wgt./lbs)
37
Page 38
Biological Activity Reaction Test
15
A simple yet effective method for monitoring the population size and/or activity of specific groups of bacteria.
Microbiological
BART Biodetector
With BART, you can monitor for Iron Related Bac­teria (IRB), Sulfate Reducing Bacteria (SRB) and Heterotrophic Aerobic Bacteria (HAB) – the three most important agents involved in biofouling. Other BART systems are described below. These bacteria can cause corrosion, clogging, fouling of the water, and increased hygiene risks, so it is important to have an easy and accurate method of determining their presence and level of activity.
The screw-cap should
be tightened on the
BART tube so that
casual leakage, such
as from tipping the
tube over, can be
prevented.
Aerobic growth of
bacteria will occur at
the surface of the
sample between the
BART-BALL and the wall
of the BART tube.
mL of water sample is
used to bring the BART-
BALL up to the correct
level. Nutrients will
gradually diffuse up the
water column to support
this bacteria growth.
Once the oxygen has
been used by the
aerobes, this zone
becomes free of oxygen
and anaerobic growth
will dominate.
Easy to Use
The BART Biodetector requires no microscope, no laboratory, and no incubator! The test is done at room temperature in your office or treatment room, on a desk, shelf, or in a cupboard, and is viewed daily. Different microorganisms like to grow at different heights in a column of water to which nutrients have been added. BART biodetectors contain nutrients in the base of a column and a ball. The ball restricts the amount of oxygen entering the water column, so that aerobic organisms grow around the ball and anaerobic organisms grow deep down in the water column. By changing the nutrients in the base of the column, different organisms are encouraged to grow. BART determines presence and activity levels.
Easy to Analyze
The time taken for a color change (reaction) to occur gives a measure of the popula­tion size and activity. A color change occurs in the BART tube as a result of the oxy­gen gradient diffusing from the bottom upward. The change of color indicates a presence of bacteria within that sample. Interpretation is provided with the kit.
The Test
Full instructions for the use of BART biodetectors are included with your purchase. Each individual test consists of:
 Test vial with media and BART ball  Outer tube for spill containment, odor control, disinfection, and disposal
To Order
Each kit number below includes nine (9) BARTs. Each BART test is color-coded for quick and easy recognition.
BART Color Test Order
Red Iron Related Bacteria - IRB-BART 5-0024 Black Sulfate Reducing Bacteria - SRB-BART 5-0025
Lime green Slime Forming Bacteria - SLYM-BART* 5-0026 Combo Three each of IRB-, SRB-, and SLYM-BART 5-0032 Blue Heterotrophic Aerobic Bacteria - HAB-BART 5-0027
38
Nutrient medium for
growth is provided as a
sterile dried pellet on the
floor of the tube.
*The SLYM-BART requires the use of a fluorescent lamp (Order Code 5-0033)
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
Page 39
In cleaning applications,
P alkalinity is sometimes
referred to as active
alkalinity. The difference
between the P reading
and the T reading is
“inactive” alkalinity.

Individual Test Kits

Acidity - Aluminum
Code 3569-01
Order Code
ACIDITY A standard base titrates acidity to the phenolphthalein endpoint. The 7182 uses different sample sizes and a 1:10 dilution to test
hydrochloric, sulfuric and phosphoric acids with either a 1 drop = 0.1% or 1 drop = 1.0 % equivalence.
7182-01 HCl, H2SO4, H3PO4
ALKALINITY Kits use titrations with standard acid to the phenolphthalein (P) and/or total (T) alkalinity endpoint. The mixed indicator, BCG-MR,
is used for total alkalinity determinations. Where hydroxyl(OH) alkalinity is determined directly, as with kit #7515, the sample is pre-treated with barium to precipitate carbonate alkalinity. All results are expressed as CaCO3. To convert results to Na2O, multiply the answer by 0.62.
4491-DR-01 Total Alkalinity
4533-DR-01 P & T Alkalinity
4533-01 P & T Alkalinity
7240-02 P & T Alkalinity
3467-01*† P & T Alkalinity
7515-01 P, T, & OH Alkalinity
ALUMINUM A pink to red color will form when aluminum reacts with Eriochrome Cyanine R at pH 6.
3569-01 Octa-Slide 2 Comparator 0, 0.1, 0.15, 0.2, 0.25, 0.3, 0.4, 0.5 ppm Al
Test System (Detailed On Pages 6-7)
Dropper Bottle
Direct Reading Titrator
Direct Reading Titrator
Dropper Pipet
Dropper Bottle
Direct Reading Titrator
Dropper Pipet
Range/Sensitivity
1 drop = 0.1 or 1.0% (as the particular acid)
0–200 ppm/4ppm as CaCO3CaCO
0–200 ppm/4 ppm as CaCO
1 drop = 10 ppm as CaCO
1 drop = 10, 25, or 50 ppm as CaCO
0–200 ppm/4 ppm as CaCO
1 drop = 10 ppm as CaCO
3
3
3
3
# of Tests
(# Reagents)
50 at 10% (2) R-7182-01 R1 (1)
3
3
50 at 200 ppm (2) R-4491-
50 at 200 ppm (3) R-4533-
50 at 200 ppm (3) R-4533 NH (1)
100 at 500 ppm (3) R-7240-02 R1 (2)
50 at 200 ppm (3) R-3467-01 R1 (1)
50 at 200 ppm (4) R-7515-01 R1 (1)
3+
50 (2) R-3569-01 NH (1)
Reagent Refill
Order Code
DR-01
DR-01
Shipping Code
(Weight/Lbs)
NH (1)
NH (1)
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
39
Page 40
Ammonia Nitrogen - Bromine
Individual Test Kits
Code 3304-01
Order Code
Test System
(Detailed On Pages 6-7)
Range/Sensitivity
# of Tests
(# Reagents)
Reagent Refill
Order Code
Shipping Code
(Weight/Lbs)
AMMONIA NITROGEN Two colorimetric methods are available. Nessler’s reagent reacts with ammonia to form a yellow to brown color; salicylate
reacts to form a blue color, which in combination with the yellow reagent color produces colors from yellow to blue. The salicylate method is preferred for salt water analysis and does not contain mercury salts as does the Nessler method.
3304-01 Salicylate,
0.0, 0.05, 0.1, 0.25, 0.5, 1.0, 2.0 ppm NH
N 50 (3) R-3304-01 R2 (1)
3
Octa-Slide 2 Comparator
5864-01 Salicylate
0.1, 0.25, 0.50, 1.0, 2.0, 4.0 ppm NH3N 50 (2) R-5864-01 R1 (1)
ColoRuler
4795-01 Nessler,
1.0, 2.0, 3.0, 4.0, 5.0, 6.0, 7.0, 8.0 ppm NH3N 50 (2) R-3315 R1 (1)
Octa-Slide 2 Comparator
3680-01 Nessler Colorimeter 0–5 ppm/0.05 ppm NH3N 100 (2) R-3680-01 R1 (1)
ARSENIC The procedure requires about 15 minutes and employs a test strip. Inorganic As+3 and As+5 are converted to arsine gas. This
reacts with the test strip in a closed container and produces yellow to brown colors on the strip. The strip color is compared to a color chart to determine concentration in ppb.
4053-02 Test Strip <4, 4, 8, 10, 12, 14, 16, 20, 25, 30, 50, 85,
50 R-4053-02 R1 (8)
100, 150, 175, 200, 300, 400 ppb
BACTERIA See Microbiological Testing section pages 36-38.
BLEACH (See Chlorine Bleach)
BROMINE Bromine may be tested using color development with DPD, or by a ferrous ammonium sulfate titration in the presence of DPD
indicator. The 6824 kit uses glycine to enable the user to separate bromine and chlorine. The 3624 titration kit uses one sample size to test chlorine and one to test bromine. It includes a 1:10 dilution for determination of concentrations of 100 ppm or higher.
6955-01 DPD Tablet,
0.2, 0.4, 0.6, 0.8, 1.0, 1.5, 2.0, 3.0 ppm Br 50 (1) R-6955-01 NH (1)
Octa-Slide 2 Comparator
6824-01 DPD Tablet, Bromine in Chlorine,
0.2, 0.4, 0.6, 0.8, 1.0, 1.5, 2.0, 3.0 ppm Br 50 (3) R-6824-01 NH (1)
Octa-Slide 2 Comparator
3672-01 DPD Tablet, Colorimeter 0–7.0 ppm/0.05 ppm Br 100 (1) R-3672-01 NH (5)
3624-01 FAS Chlorine or Bromine, Direct
Reading Titrator
0–10 ppm/0.2 ppm Cl or Br 0-100 ppm/2 ppm Cl or Br
50 at 10 ppm (3)
R-3624-01 NH (1)
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com40
Page 41
Code 7297-DR-01
Individual Test Kits
Cadmium - Chloride
To measure sodium
chloride levels in pools see
test strips on page 34.
Order Code
CADMIUM A dithizone extraction of cadmium produces a pink to red color.
7839-01 Octa-Slide 2 Comparator 0.1, 0.2, 0.3, 0.4, 0.5, 0.6, 0.8, 1.0 ppm Cd 20 (4) R-7839-02 HF (1)
CALCIUM (See Hardness)
CARBON DIOXIDE A standard alkali is used to titrate samples to the phenolphthalein endpoint.
7297-DR-01 Direct Reading Titrator 0–50 ppm/1.0 ppm CO
CAUSTIC A sample is reacted with barium to precipitate any carbonates, then is titrated with a standard acid to the phenolphthalein endpoint.
The 7181 includes a 1:10 dilution, resulting in a 1 drop = 0.1% or 1 drop = 1% equivalence.
7516-DR-02 Direct Reading Titrator 0–10%/0.2% NaOH 50 at 10% (4) R-7516-DR-02 R1 (1)
7181-01 Dropper Bottle 1 drop = 0.1 or 1% NaOH 50 at 10% (3) R-7181-01 R1 (1)
CHELANT Free chelant is determined by using the back titration of a hardness test, with magnesium as the titrant. Since bismuth will displace
other metals from chelants, it is used for total chelant determinations. Both tests use different sample sizes to determine NTA or EDTA.
7144-01 Free Chelant
7143-01 Total Chelant
CHLORIDE The argentometric method is used with all kits. This employs a chromate indicator and silver nitrate titrant. Hydrogen peroxide is
included with kits 7172 and 7247 to eliminate sulfite interference.
3468-01*† Direct Reading Titrator 0–50 ppm/1 ppm Cl
4503-DR-02 Direct Reading Titrator 0–200 ppm/4 ppm Cl
7459-02 Salinity
7172-02 Dropper Bottle 1 drop = 10, 25, or 50 ppm Cl
7247-01 Dropper Bottle 1 drop = 2, 5, or 10 ppm Cl
Test System
(Detailed On Pages 6-7)
Dropper Bottle
Dropper Bottle
Direct Reading Titrator
Range/Sensitivity
2
1 drop = 2 ppm EDTA 1 drop = 2 ppm NTA
1 drop = 5 ppm EDTA 1 drop = 5 ppm NTA
0–20,000 ppm/400 ppm
0-20 ppt/0.4 ppt Salinity 50 at 20 ppt (2) R-7459-02 R1 (1)
# of Tests
(# Reagents)
50 at 50 ppm (2) R-7297-DR-01 R1 (1)
100 (3) R-7144-01 R1 (1)
100 (3) R-7143-01 HF (1)
50 (2) R-3468-01 NH (1)
50 at 200 ppm (4) R-4503-DR-02 R1 (1)
120 at 100 ppm (5) R-7172-02 R1 (2)
120 at 10 ppm (5) R-7247-01 R1 (1)
Reagent Refill
Order Code
Shipping Code
(Weight/Lbs)
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com 41
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
Page 42
Chlorine - Chlorine
Individual Test Kits
Code 3670-01
Order Code
CHLORINE Free, Combined and Total Chlorine may be determined using DPD with either colorimetric or titrimetric methods. These
determinations are generally limited to concentrations of 0–10 ppm, although the FAS titration can test higher concentrations by dilution or with the addition of more DPD indicator. Higher concentrations require the iodometric titration, whereby the sample is acidified and iodide is added, which is oxidized by chlorine to iodine and is titrated with a standard thiosulfate solution. Iodometric determinations will only test total chlorine.
FREE & TOTAL
3308-01* DPD Tablet
3312-01* DPD Tablet
3313-01* DPD Tablet
3314-01* DPD Tablet
3328-01 DPD Tablet
3670-01 DC1200-CL
3670-01-LI DC1200-CL-LI
DPD FREE CHLORINE, MONOCHLORAMINE, DICHLORAMINE, & TOTAL CHLORINE
3316-01 DPD Tablet
DPD FREE, MONO & DICHLORAMINES, TOTAL CHLORINE, pH
6980-01 DPD Tablet/
Test System
(Detailed On Pages 6-7)
Octa-Slide 2 Comparator
Octa-Slide 2 Comparator
Octa-Slide 2 Comparator
Octa-Slide 2 Comparator
Octa-Slide 2 Comparator
DPD Tablet Colorimeter
DPD Liquid Colorimeter
Octa-Slide 2 Comparator
Phenol Red Tablet Octa-Slide 2 Comparator
Range/Sensitivity
0.2, 0.4, 0.6, 0.8, 1.0, 1.5, 2.0, 3.0 ppm Cl 50 (2) R-3308-01 NH (1)
0.1, 0.2, 0.3, 0.4, 0.5, 0.6, 0.8, 1.0 ppm Cl 50 (2) R-3312-01 NH (1)
1.0, 1.5, 2.0, 2.5, 3.0, 4.0, 5.0, 6.0 ppm Cl 50 (2) R-3313-01 NH (1)
Low: 0.1–1.0 ppm Cl High: 1.0–6.0 ppm Cl
1.0, 2.0, 3.0, 4.0, 5.0, 6.0, 8.0, 10.0 ppm Cl 50 (2) R-3328-01 NH (1)
0–4.0 ppm/0.05 ppm Cl 100 (2) R-3670-01 NH (4)
0–4.0 ppm/0.05 ppm Cl 144 (3) R-3670-01-LI R1 (5)
0.2, 0.4, 0.6, 0.8, 1.0, 1.5, 2.0, 3.0 ppm Cl 50 (4) R-3316-01 NH (1)
Low: 0.1–1.0 ppm Cl High: 1.0–6.0 ppm Cl pH: 6.8–8.2
# of Tests
(# Reagents)
100 (2) R-3314-01 NH (1)
200 (5) R-6980 NH (7)
Reagent Refill
Order Code
Shipping Code
(Weight/Lbs)
42
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
Page 43
Code 4497-01
Individual Test Kits
Chlorine - Chlorine Test Papers
Clean sample cells
used in DPD test
reactions as soon
as possible. DPD
can stain!
Order Code
CHLORINE ...Continued
DPD-FAS TITRATION FOR FREE AND TOTAL CHLORINE
3176-02*† Direct Reading Titrator 0–10 ppm/0.2 ppm Cl 50 at 10 ppm (4) R-3176-02 R1 (2)
3624-01 Chlorine or Bromine
7514-01 FAS
IODOMETRIC TITRATION (For higher total chlorine levels)
4497-DR-01 Direct Reading Titrator 0–200 ppm/4 ppm Cl 50 at 200 ppm (3) R-4497-DR-01 R2 (1)
4497-01 Dropper Pipet 1 drop = 10 ppm Cl 50 at 200 ppm (3) R-4497-01 R2 (1)
4501-01 Dropper Pipet 1 drop = 1 ppm Cl 50 (3) R-4501-01 R2 (1)
CHLORINE BLEACH, IODOMETRIC TITRATION
7105-03 Direct Reading Titrator 0–10%/0.2% Cl 50 at 10% (3) R-7105-03 R1 (2)
7894-01 Dropper Pipet 1 drop = 0.005%, 0.05%, or 0.5% Cl 50 at 0.1, 1.0, or 10% (3) R-7894-01 R1 (1)
CHLORINE TEST PAPERS/STRIPS See other Chlorine test strips on page 34.
4250-BJ Chlorine Test Papers 10, 50, 100, 200 ppm, Cl 200 (1) R-4250-BJ NH (1)
2964-G Chlorine Test Strips 0, 0.5, 1, 3, 5, 10 ppm, Free Cl 25 (1) R-2964-G
2963LR-G Chlorine Test Strips 0, 0.1, 0.25, 0.5, 1, 3, 10 ppm, Total Cl 25 (1) R-2963LR-G
3031 Chlorine Test Strips 0, 50, 100, 250, 500, 800 ppm Cl 50 (1) R-3031
2979 Chlorine Test Strips 0, 0.5, 1, 3, 5 ppm Total Cl 50 (1) R-2979
Test System
(Detailed On Pages 6-7)
Direct Reading Titrator
Dropper Bottle Titration
Range/Sensitivity
0–10 ppm/0.2 ppm Cl or Br 0–100 ppm/2 ppm Cl or Br
1 drop = 0.2 or 0.5 ppm Cl 50 (3) R-7514-01 NH (1)
# of Tests
(# Reagents)
50 at 10 ppm (3) R-3624-01 NH (1)
Reagent Refill
Order Code
Shipping Code
(Weight/Lbs)
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
43
Page 44
Chlorine Dioxide - Copper
Reagent Tip:
Determine when your reagent
was made and bottled. The first
Individual Test Kits
two numbers of a lot number
signify the week, the third is the
year the reagent was made.
Thus 506XXX was made in the
50th week of 2016. For more
details see page 76.
Code 6616-01
Order Code
CHLORINE DIOXIDE The colorimetric kits use DPD to determine chlorine dioxide. Glycine is added in the method to remove free chlorine
interferences. Chlorite up to 1,000 ppm and chlorine up to 2 ppm will not interfere with the test strip determinations.
3622-01 Octa-Slide 2 Comparator 0.0, 0.2, 0.6, 0.8, 1.0, 2.0, 3.0, 5.0 ppm ClO2 (0–10
3671-01 DC1200-CLO
2999LR Test Strip 0, 0.25, 0.50, 1.0, 3.0, 10 ppm 50 R-2999LR NH (1)
3002 Test Strip 0, 10, 25, 50, 100, 250, 500 ppm 50 R-3002 NH (1)
CHROMATE Diphenylcarbazide reacts with chromate (hexavalent chromium) to form a red to violet color in an acid solution.
4430-01 Diphenylcarbazide
COLIFORM See also Microbiological Testing section pages 36-38.
COLOR The color of water is measured by comparing the water to platinum cobalt color standards representing APHA Standard Color Units.
3528-01 LRC Comparator 0, 20, 50, 80, 110, 140, 170, 200 APHA color units Unlimited (0) R-3528-01 NH (2)
COPPER A yellow color is formed when copper reacts with diethyldithiocarbamate (DDC). A blue color is formed when copper reacts with
Cuprizone.
6616-01 LRC Comparator 0, 0.05, 0.10, 0.15, 0.20, 0.30, 0.40, 0.50 ppm Cu 50 (1) R-6616-01 NH (1)
3619 Cuprizone
3673-01 DC1200-CO
Test System
(Detailed On Pages 6-7)
Colorimeter 0–7 ppm/0.05 ppm ClO
Octa-Slide 2 Comparator
Color Chart
DDC Colorimeter
Range/Sensitivity
by dilution)
5, 10, 15, 20, 25, 30, 35, 40 ppm Na2CrO4
(lower or higher ranges by dilution)
0.05, 0.10, 0.15, 0.20, 0.30, 0.50, 0.70, 1.0 ppm Cu 50 (2) R-3619 R1 (1)
0–8 ppm/0.03 ppm Cu 100 (1) R-3673-01 NH (7)
# of Tests
(# Reagents)
50 (2) R-3622-01 NH (1)
2
100 (2) R-3671-01 NH (3)
50 (1) R-4430-01 R1 (1)
Reagent Refill
Order Code
Shipping Code
(Weight/Lbs)
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com44
Page 45
Cyanide - Glutaraldehyde
TWO CHOICES
FOR REFILLS:
1. For a complete set, add “R-” to the kit
number.
2. For individual
reagents, order by the
code on the reagent. See pages 76-83 for
a list of kit reagents.
Individual Test Kits
Code 6701-01
Order Code
CYANIDE The cyanide is first reacted with a chlorine donor to form cyanogen chloride, which then reacts with pyridine-barbituric acid to form a
red-blue color. The test is also applicable as a screening test for concentrations up to 250 ppm.
7387-02 Octa-Slide 2 Comparator 0.0, 0.10, 0.15, 0.20, 0.25, 0.30, 0.35, 0.40 ppm
DEHA Diethylhydroxylamine reacts with ferric iron to form ferrous iron, which is then measured by a standard iron test.
4790-01 Octa-Slide 2 Comparator 0.05, 0.1, 0.2, 0.4, 0.6, 0.8, 1.0, 1.5 ppm DEHA 100 (3) R-4790-01 R1 (1)
DETERGENTS Anionic surfactants are extracted with toluene and break up an ion pair, releasing bromphenol blue into a water layer.
A standard color reagent is then used to determine the concentration.
4507-02 Dropper Pipet 1 drop = 1.0 ppm Detergent 60 at 5.0 ppm (3) R-4507-02 R1 (2)
4515-01 Dropper Pipet 1 drop = 0.1 ppm Detergent 30 (4) R-4515-01 LQ (2)
FLUORIDE A red zirconium lake reacts with fluoride to form a colorless solution, which decreases the red color of the solution in proportion to
concentration.
3674-01 DC1200-FL
FORMALDEHYDE The colorimetric analysis uses a modified Schiff reaction in which an acidified pararosaniline and dichlorosulfitomercurate II
complex form a violet color.
6701-01 Octa-Slide 2 Comparator 0.0, 0.5, 1.0, 2.0, 4.0, 6.0, 8.0, 10.0 ppm
GLUTARALDEHYDE High concentrations are determined by a titration with sulfuric acid after reaction with sulfite.
7064-01 Direct Reading Titrator 1 mL = 250 ppm Glutaraldehyde 25 (5) R-7064-01 R2 (3)
Test System
(Detailed On Pages 6-7)
Colorimeter 0–2.0 ppm/0.03 ppm Fl
Range/Sensitivity
Free CN–
Formaldehyde
# of Tests
(# Reagents)
50 (5) R-7387-02 R1 (3)
100 (2) R-3674-01 LQ (7+5)
100 (3) R-6701-01 LQ (2+5)
Reagent Refill
Order Code
Shipping Code
(Weight/Lbs)
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
45
Page 46
Hardness - Hydrazine
Individual Test Kits
Hardness originally referred
to the ability of water to
lather with soap. The more
calcium and magnesium
ions present, the “harder” it
was to produce a lather.
Code 4482-LI-02
Order Code
HARDNESS EDTA titration is used for all hardness determinations, with a red to blue endpoint. Both total and calcium hardness buffers include
inhibitors to eliminate metal interferences. All results are as CaCO3; some kits also express results as gpg. The 3609, which is recommended for salt water analysis, includes a conversion factor for Ca++. The -LI suffix indicates an all liquid kit; -LT indicates a liquid buffer and tablet indicator.
3609-01 Fresh & Salt Water
4482-DR-LI-01 Total Hardness
4482-LI-02 Total Hardness
4482-DR-LT-01 Total Hardness
4824-LT-02 Calcium, Magnesium, Total
4824-DR-LT-01 Calcium, Magnesium, Total
3037-DR-01 Low Range Total Hardness
7171-02 Total Hardness
7246-02 Total Hardness
Test System
(Detailed On Pages 6-7)
Calcium Hardness Direct Reading Titrator
Direct Reading Titrator
Dropper Bottle
Direct Reading Titrator
Hardness Dropper Bottle
Hardness Direct Reading Titrator
Direct Reading Titrator
Dropper Bottle
Dropper Bottle
Range/Sensitivity
0–200 ppm/4 ppm CaCO 0-2,500 ppm by dilution
0–200 ppm/4ppm CaCO3 Liquid indicator
1 drop = 10 ppm or 1 gpg CaCO3 Liquid indicator
0–200 ppm/4 ppm CaCO3 Tablet indicator
1 drop = 10 ppm or 1 gpg CaCO3 Tablet indicator
0–200 ppm/4 ppm CaCO3 Tablet indicator
0–10 ppm/0.2 ppm CaCO
1 drop = 10, 25, or 50 ppm CaCO
1 drop = 2, 5, or 10 ppm CaCO
3
3
3
# of Tests
(# Reagents)
50 (3) R-3609-01 R1 (1)
50 at 200 ppm (3) R-4482-DR-LI-01 R1 (1)
50 at 200 ppm
or 20 gpg (3)
50 at 200 ppm (3) R-4482-DR-LT-01 R1 (1)
50 at 200 ppm
or 20 gpg (5)
50 at 200 ppm (5) R-4824-DR-LT-01 R1 (1)
50 at 10 ppm (3) R-3037-DR-01 R1 (1)
3
100 (3) R-7171-02 R1 (1)
100 (3) R-7246-02 R1 (1)
Reagent Refill
Order Code
R-4482-LI-02 R1 (1)
R-4824-LT-02 R1 (1)
Shipping Code
(Weight/Lbs)
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com46
Page 47
Hydrogen Peroxide - Lead
Code 3347-01
Individual Test Kits
Order Code
Test System
(Detailed On Pages 6-7)
Range/Sensitivity
# of Tests
(# Reagents)
Reagent Refill
Order Code
Shipping Code
(Weight/Lbs)
HYDROGEN PEROXIDE Although peroxide may be tested colorimetrically with DPD, the most common method is iodometric titration using a
standard thiosulfate solution. Both methods are offered.
7138-DB-01 Iodometric
Dropper Bottle
7150-01 Iodometric
Dropper Bottle
1 drop = 5 ppm H2O
1 drop = 0.5% H2O
2
2
50 (4) R-7138-DB-01 LQ (2)
50 (4) R-7150-01 LQ (2)
2984LR Test Strips 0, 1, 3, 10, 30, 50 25 (1) R-2984LR-H NH (1)
IODINE As with many other oxidizers, iodine may be titrated with a standard thiosulfate solution, hence the name iodometric titration.
7253-DR-01 Direct Reading Titrator 0–50 ppm/1 ppm I
2
50 at 50 ppm
R-7253-DR-01 R1 (1)
(3)
7253-01 Dropper Pipet 1 drop = 2.5 ppm I
2
100 at 25 ppm
R-7253-DR-01 R1 (1)
(3)
2948-BJ Test Papers 12, 25, 50, 100 ppm I
2
200 R-2948-BJ NH (1)
IRON Bipyridyl is a ferrous iron indicator that tests total iron after any ferric iron is reduced to ferrous in the sample. Ferrous and ferric may be
tested separately by eliminating the reduction step. A similar ferrous indicator, 1,10 phenanthroline, is used in the DC1200 kit.
7787-01 Total Iron
0.05, 0.10, 0.20, 0.30, 0.40, 0.60, 0.80, 1.0 ppm Fe 30 (2) R-7787-01 R1 (1)
LRC Comparator
4447-01 Total Iron
0.5, 1.0, 2.0, 3.0, 4.0, 6.0, 8.0, 10.0 ppm Fe 90 (2) R-3318 R1 (1)
Octa-Slide
3347-01 Ferrous/Ferric Iron
0.5, 1.0, 2.0, 3.0, 4.0, 6.0, 8.0, 10.0 ppm Fe 100 (3) R-3347-01 R1 (1)
Octa-Slide 2 Comparator
3681-01 DC1200-FE
Total Iron 1, 10 Phenanthroline
0–4.0 ppm/0.25 ppm Fe 100 (2) R-3681-01 R1 (1)
Colorimeter
LEAD The presence of lead in solder is detected by the reaction of a solder sample with acid and sodium rhodizonate.
3582-01 Spot Plate
Yes/No 100 (3) R-3582 R1 (2)
Plumbing Inspector Kit
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com 47
Page 48
Manganese - Molybdenum
Individual Test Kits
Molybdenum x 1.6 = Molybdate
Sodium Molybdate Dihydrate x 0.4 = Molybdenum
Code 6628-01
Molybdate x 0.63 = Molybdenum
Order Code
MANGANESE The 1-(2-pyridylazo)-2-naphthol(PAN) method forms an orange complex with manganese. Metal interferences with the PAN
method can be eliminated using the #7104 Cyanide Inhibitor Package, sold separately.
3588-02 PAN
3682-01 DC1200-MN
MICROBIOLOGICAL TESTING See section pages 36-38.
MOLYBDATE/MOLYBDENUM There are three colorimetric methods and one titration method available. The 6628 uses Xanthogonate to form
a pink color with molybdate. Thioglycolate forms a yellow color for low to high determinations. The 3628 uses a new test strip technology that reads 0, 0.5, 1, 2 and 5 ppm. Results are available in about 1 minute. The 3632 titration employs citric acid with a red to yellow color change. The sample size may be changed to vary the equivalence.
3628-01 Test Strip 0, 0.5, 1.0, 2.0, 5.0 ppm 50 (1) R-3628-01 R1 (1)
6628-01 Xanthate, Sodium Molybdate
3346-01 Thioglycolate, Molybdate
3160-01 Thioglycolate, Molybdenum
3632-01 Molybdenum
3676-01 DC1200-MO
Test System
(Detailed On Pages 6-7)
Octa-Slide 2 Comparator
PAN Colorimeter
Octa-Slide 2 Comparator
Octa-Slide 2 Comparator
Octa-Slide 2 Comparator
Dropper Pipet
Thioglycolate Colorimeter
Range/Sensitivity
0.05, 0.1, 0.2, 0.4, 0.6, 0.8, 1.0 ppm Mn 50 (4) R-3588-02 LQ (2)
0–0.7 ppm/0.01 ppm Mn 100 (3) R-3682-01
1, 2, 3, 4, 5, 6, 8, 10 ppm Sodium Molybdate
30, 60, 90, 120, 150, 180, 240, 300 ppm Molybdate
2, 5, 8, 10, 12, 15, 18, 20 ppm Molybdenum 50 (3) R-3160-01 R3 (2)
1 drop = 2 or 20 ppm Molybdenum 50 (3) R-3632-01 LQ (2+5)
0-30 ppm/0.1 ppm Molybdenum 50 (3) R-3676-01
# of Tests
(# Reagents)
100 (2) R-6628-01 R1 (1)
50 (2) R-3346-01 NH (1)
Reagent Refill
Oder Code
DC1200-MN
DC1200-MO
Shipping Code
(Weight/Lbs)
R3 (7+5)
R3 (7)
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com48
Page 49
Code 3354-01
Individual Test Kits
Nitrate Nitrogen - Nitrite, Sodium
The current EPA limit
for nitrate is 10 ppm
as nitrogen. Multiply
nitrogen readings by
4.4 to convert reading to nitrate.
Order Code
Test System
(Detailed On Pages 6-7)
Range/Sensitivity
# of Tests
(# Reagents)
Reagent Refill
Oder Code
Shipping Code
(Weight/Lbs)
NITRATE NITROGEN The nitrate is reduced to nitrite by cadmium or zinc and this undergoes diazotization/coupling to form a pinkish color. All kits
below use cadmium except #3354, which uses zinc and which also contains a reagent that eliminates nitrite interference. Kit #3519 tests both nitrate and nitrite. The kit #3119 uses one comparator that contains both nitrate and phosphate standards. The phosphate method in kit #3119 is an ascorbic acid reduction. See page 16 for Total Nitrogen Digestion Tube Test.
3119-01 Cadmium Reduction
Nitrate/Phosphate LRC Comparator
3615-01 Cadmium Reduction,
Nitrate/Nitrite
0.2, 0.4, 0.6, 1.0 ppm NO
0.2, 0.4, 0.6, 1.0 ppm PO
–N;
3
3
4
0, 0.2, 0.4, 0.6, 0.8, 1.0 ppm NO
–N 50 (2) R-3615-01 R1 (2)
3
Nitrate: 40 (2)
Phosphate:
50 (2)
R-3119-01 R1 (2)
LRC Comparator
3519-01 Cadmium Reduction
Octa-Slide 2 Comparator
3354-01 Zinc Reduction
Octa-Slide 2 Comparator
3677-01 DC1200-NA
Cadmium Reduction Colorimeter
0.25, 0.5, 1.0, 2.0, 4.0, 6.0, 8.0, 10.0 ppm NO
0.0, 1.0, 2.0, 4.0, 6.0, 8.0, 10.0, 15.0 ppm NO
0–3.0 ppm/0.05 ppm NO
–N 50 (2) R-3677-01 R1 (7)
3
–N 40 (3) R-3519-01 R1 (1)
3
–N 50 (2) R-3354-01 NH (2)
3
NITRITE NITROGEN As with nitrate, above, the diazotization/coupling reaction is used to form a pink color with nitrite.
3352-01 Octa-Slide 2 Comparator 0.05, 0.10, 0.20, 0.30, 0.40, 0.50, 0.60, 0.80 ppm
NO
–N
2
50 (3) R-3352-01 NH (2)
NITRITE, SODIUM Sodium nitrite is titrated using one of two methods. After acidifying the sample, permanganate will oxidize nitrite. When all of
the nitrite is oxidized, the permanganate turns the sample pink. Ceric Ammonium Nitrate (CAN) also oxidizes the nitrite in the presence of ferroin indicator. The endpoint is orange to blue. The CAN method is preferred if glycol is present.
7101-DR-01 Permanganate
Direct Reading Titrator
7101-01 Permanganate
Dropper Pipet
3036-DR-02 CAN
Direct Reading Titrator
7183-02 CAN
Dropper Bottle
0–1000 ppm/20 ppm NaNO
1 drop = 50 or 100 ppm NaNO
0–1000 ppm/20 ppm NaNO
1 drop = 50 ppm NaNO
2
2
2
2
50 at 1000
ppm (2)
50 at 1000 or
2000 ppm (2)
50 at 1000
ppm (2)
50 at 1000
R-7101-DR-01 R1 (1)
R-7101-01 R1 (1)
R-3036-DR-02 R1 (1)
R-7183-02 R1 (1)
ppm (2)
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
49
Page 50
Oxygen, Dissolved - pH
It is important in all drop titrations to hold the
titrant vertically. This ensures proper drop size.
Individual Test Kits
Code 5860-01
Order Code
Test System
(Detailed On Pages 6-7)
Range/Sensitivity
# of Tests
(# Reagents)
Reagent Refill
Oder Code
Shipping Code
(Weight/Lbs)
OXYGEN, DISSOLVED The azide modification of the Winkler method is a modified iodometric titration whereby oxygen, in the presence of a strong
alkali, oxidizes manganese, which in turn reacts with iodide to form iodine. This is titrated with a standard thiosulfate solution in the presence of a starch indicator to enhance the endpoint. Azide eliminates nitrite interference.
5860-01 All liquid reagents
Direct Reading Titrator
0–10 ppm/0.2 ppm O
2
50 at
10 ppm (5)
R-5860-01 R1 (2)
OZONE DPD reacts with ozone, but any other oxidizers will interfere. The Indigo Trisulfonate method includes a step to eliminate chlorine
interference, but bromine will interfere. It is preferred for the analysis of salt water samples.
3678-01 DC1200-OZ
Indigo Trisulfonate Colorimeter
0–0.4 ppm/0.04 ppm O
3
100 (3) R-3678-01 NH (7)
PERACETIC ACID/HYDROGEN PEROXIDE This test is a combination of two separate titrations. The first is a cerium titration of peroxide. The
second is an iodometric titration of peracetic acid.
7191-02 Dropper Bottle 1 drop = 50 ppm Peroxide
50 (5) R-7191-02 R1 (2)
1 drop = 6, 15 or 300 ppm Peracetic Acid
PERACETIC ACID TEST STRIP
3000 Test Strips 0, 10, 20, 50, 85, 160 ppm 50 NH (1)
3000LR Test Strips 0, 5, 10, 20, 30, 50 ppm 50 NH (1)
3000HR Test Strips 0, 50, 100, 250, 500, 1000 50 NH (1)
pH TEST PAPERS
2907 Test Papers 6.8-8.4 pH/0.4 pH 1 Roll NH (1)
2912 Test Papers 3.0-10.0 pH/1 pH 200 Strips NH (1)
2953 Test Papers 4.5-7.5 pH/0.5 pH 1 Roll NH (1)
2954 Test Papers 0-13 pH/1 pH 1 Roll NH (1)
2956 Test Papers 1-11 pH/1 pH 1 Roll NH (1)
2959 Test Papers 8-12 pH/0.5 pH 2 Rolls NH (1)
3-2950 pH Indicator Sticks 0–14/1 pH 100 Strips NH (1)
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com50
Page 51
pH
pH must be controlled and monitored because it plays an essential role in almost all chemical and biological processes.
pH indicators work in a specific range. Samples
with a pH above the range of an indicator
may match the highest standard on the
comparator; samples below the range may
match the lowest standard.
Individual Test Kits
Code 5858-01
LaMotte pH Test Kits
The “Precision Wide Range” pH kit includes the Octa-Slide comparator and reagents to provide 100 tests. Other pH test kits consist of an Octa-Slide Comparator, and a reagent for 50 tests. LaMotte Company has been supplying laboratory quality pH indicator tests to professional analysts for more than eighty years; these are the most reliable, economical pH test kits available. Simply fill the tube to the mark with the sample water, add several drops of indicator, and compare the resulting color against the eight permanent color standards in the comparator.
How To Select The Right pH Kit:
Single or Wide Range?
Single range kits cover a range of 1.4 pH units in 0.2 unit increments (0.1 unit sensitivity). Wide range kits cover pH units in increments of 0.5.
See Instrument
Section, pages 22-30
for pH meters.
Which Range?
Choose a kit in which the midpoint of the range covered is as close to the average or optimum pH value of the sample water. If this value is unknown, choose the Precision Wide Range Kit.
Indicators specific to a particular pH range allow colorimetric determination of pH. If the water to be tested is cloudy, one may wish to use a pH meter.
Order Code
pH
2109-01 Bromthymol Blue 6.0 6.2 6.4 6.6 6.8 7.0 7. 2 7. 4 R-2109-01 NH (1) 2110-01 Phenol Red 6.8 7. 0 7.2 7. 4 7. 6 7. 8 8.0 8.2 R-2110-01 NH (1) 2111-01 Cresol Red 7. 2 7. 4 7.6 7. 8 8.0 8.2 8.4 8.6 R-2111-01 NH (1) 2112-01 Thymol Blue 8.0 8.2 8.4 8.6 8.8 9.0 9.2 9.4 R-2112-01 NH (1)
5858-01 Precision Wide Range
2124-01 Alkaline Wide Range 8.5 9.0 9.5 10.0 10.5 11.0 11.5 12.0 R-2124-01 R1 (1) 3353-01 Precision Wide Range 5.0 6.0 6.5 7. 0 7.5 8.0 9.0 10.0 R-3353-01 R1
pH Indicator
3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5
7.0 7.5 8.0 8.5 9.0 9.5 10.0 10.5
Octa-Slide Comparator Color
Standard Values In pH Units
Reagent Refill
Oder Code
R-5858-01 R1 (1)
Hazard (Shipping
Weight/Lbs)
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com 51
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
Page 52
Phosphate - Phosphate
Individual Test Kits
Code 3114-02
Order Code
Test System
(Detailed On Pages 6-7)
Range/Sensitivity
# of Tests
(# Reagents)
Reagent Refill
Oder Code
Shipping Code
(Weight/Lbs)
PHOSPHATE There are 3 colorimetric test methods. In two, a phosphomolybdate complex is reduced by stannous chloride or ascorbic acid to
produce a blue color. In a third, phosphate forms a yellow complex with vanadomolybdate.
3
3679-01 DC1200-PLR
Ascorbic Acid Colorimeter
3121-02 Ascorbic Acid
LRC Comparator
3114-02 Ascorbic Acid
Octa-Slide 2 Comparator
7416-02 Stannous Chloride
LRC Comparator
4408-01 Stannous Chloride
Octa-Slide 2 Comparator
7068-01 Stannous Chloride
Octa-Slide 2 Comparator
4401-02 Vanadate Molybdate
Octa-Slide 2 Comparator
0–3.0 ppm/0.07 ppm PO
0, 0.2, 0.4, 0.6, 0.8, 1.0, 1.5, 2.0 ppm PO
0.5, 1.0, 2.0, 3.0, 4.0, 6.0, 8.0, 10.0 ppm and 5.0, 10.0,
20.0, 30.0, 40.0, 60.0, 80.0, 100.0 ppm PO
0.05, 0.1, 0.2, 0.3, 0.4, 0.6, 0.8, 1.0 ppm PO
Low: 1.0, 2.0, 3.0, 4.0, 5.0, 6.0, 8.0, 10.0 ppm PO High: 10, 20, 30, 40, 50, 60, 80, 100 ppm PO
Low: 1.0, 2.0, 3.0, 4.0, 5.0, 6.0, 8.0, 10.0 ppm PO High: 10, 20, 30, 40, 50, 60, 80, 100 ppm PO
10, 20, 30, 40, 50, 60, 70, 80 ppm PO
4
3
4
3
4
3
4
3
4
3
4
3
4
3
4
3
4
PHOSPHATE (TOTAL) Polyphosphates (acid-hydrolyzable or condensed) and phosphonates (organic phosphates) are reverted
100 (2) R-3679-01 R2 (7)
50 (2) R-3121-02 R1 (1)
50 (2) R-3114-02 R1 (1)
50 (2) R-7416-02 R1 (1)
50 (2) R-4408-01 LQ (1)
50 (2) R-7068-01 LQ (1)
50 (1) R-4401-02 R1 (1)
HF (2)
using the reagents and apparatus in the 7884 Auxiliary Phosphate kit. The polyphosphates require boiling or microwaving with acid and subsequent neutralization; the phosphonates require the same, but with the addition of an oxidizer in the boiling/ microwaving step. Once reverted to orthophosphate, any of the tests in the orthophosphate section above may be used for analysis. See page 17 for Total Phosphorus Digestion Tube Tests.
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com52
Page 53
Phosphonate - Potassium
Code 7625-01
Individual Test Kits
Order Code
Test System
(Detailed On Pages 6-7)
Range/Sensitivity
# of Tests
(# Reagents)
Reagent Refill
Oder Code
Shipping Code
(Weight/Lbs)
PHOSPHONATE The Chromazurol S method may be used for Dequest (xo), Bayhibit (CAS), Belcor 575 (xo) and Belsperse 161 phosphonates
(CAS). An additional liquid acid is included for very high alkalinity samples. It also includes a fluoride inhibitor reagent.
The 7611 sulfate interference suppressor kit uses barium precipitation and filtration to eliminate sulfate from the phosphonate test.
7625-DR-01 CAS
0–20 ppm/0.4 ppm HEDP/PBTC 50 at 20 ppm (5) R-7625-DR-01 R1 (1)
Direct Reading Titrator
7625-01 CAS
Dropper Pipet
7530-DR-01 XO
1 drop = 1.25 ppm HEDP
50 at 20 ppm (5) R-7625-01 R1 (1)
1 drop = 1.4 ppm PBTC
0–20 ppm/0.4 ppm NaAMP 50 at 20 ppm (5) R-7530-DR-01 R1 (2)
Direct Reading Titrator
7530-WT-01 XO
1 drop = 1 ppm NaAMP 50 at 20 ppm (5) R-7530-WT-01 R1 (2)
Dropper Bottle
POLYPHOSPHATES A colorimetric method is available for waters where metal interference is unlikely. An excess of iron is added to the solution
containing polyphosphate. The iron is complexed and the remaining iron is determined. The polyphosphate concentration is derived from the iron concentration.
7340-R-01 LRC Comparator 0, 3, 6, 9, 12, 15 ppm Polyphosphate 50 (3) R-7340-R-01 R2 (1)
POLYQUAT The test is based on the reaction of the cationic polyquat with an anionic polyelectrolyte using Toluidine Blue O as the indicator. The
color change is blue to purple.
7056-01 Dropper Bottle 1 drop = 1 ppm Polyquat 100+ (5) R-7056-01 R1 (1)
POTASSIUM Sodium tetraphenylboron reacts with potassium to form a white precipitate. The turbidity of the solution is proportional to
potassium concentration which is measured in a calibrated tube.
3138-01 Turbidity Reading Tube 6, 8, 10, 20, 30, 40, 50 ppm K
+
100 (2) R-3138-01 R1 (1)
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com 53
Page 54
QAC - Sulfate
Individual Test Kits
Many wood treating companies use QAC kits to monitor their
products because the
wood preservatives
react similarly to QAC.
Code 3043-DR-01
Order Code
QAC Two methods are available. A masked bromphenol blue indicator is added to the sample and turns green. Sodium tetraphenyl-boron is
added to complex the QAC and the color changes to red. This method is best suited to higher QAC concentrations. A poly-electrolytic titration, like the one used for polyquat, is used for low to high concentrations.
3043-DR-01 BPB
3042-01 BPB
7057-01 Polyelectrolytic
2951 Test Papers 50, 100, 200, 400 ppm 100 NH (1)
2951HR Test Strips 200, 400, 600, 1000, 1500 ppm 50 NH (1)
SALINITY Salinity is based on the concentration of chloride. An argentometric titration with silver nitrate is used to determine the chloride
concentration.
7459-02 Direct Reading Titrator 0–40 ppt/0.4 ppt Salinity 50 at 20 ppt (2) R-7459-02 R1 (1)
SILICA The heteropoly blue method tests for “molybdate-reactive” silica. The 4463 uses a 1:10 dilution to expand the range of the kit to 100
ppm.
4463-01 Octa-Slide 2 Comparator 0.5, 1.0, 2.0, 3.0, 4.0, 6.0, 8.0, 10.0 ppm or
SODIUM NITRITE (See Nitrite, Sodium)
SULFATE Barium forms a precipitate with sulfate. The turbidity formed is measured using comparator standards or a meter.
7778-01 Tablet
3683-01 Colorimeter 0–100 ppm/1.0 ppm SO
The 7611 sulfate interference suppressor kit uses barium precipitation and filtration to eliminate sulfate from the phosphonate test.
Test System
(Detailed On Pages 6-7)
Direct Reading Titrator
Direct Reading Titrator
Dropper Bottle
Octa-Slide 2 Comparator
Range/Sensitivity
0–500 ppm/10 ppm Alkyl dimethyl benzyl ammonium chloride
0-1,000 ppm/20 ppm 0-5,000 ppm/100 ppm with dilution
1 drop = 2, 5, or 10 ppm Alkyl dimethyl benzyl ammonium chloride
5, 10, 20, 30, 40, 60, 80, 100 ppm SiO
20, 40, 60, 80, 100, 120, 160, 200 ppm SO
2
4
2
2
4
# of Tests
(# Reagents)
50 at 500 ppm
(2)
50 at 1,000 ppm
(2)
100+ (5) R-7057-01 R1 (2)
50 (4) R-4463-01 R1 (1)
50 (1) R-7778-01 R1 (1)
100 (1) R-3683-01 R1 (6)
Reagent Refill
Oder Code
R-3043-
DR-01
R-3042-01 NH (1)
Shipping Code
(Weight/Lbs)
NH (1)
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com54
Page 55
Sulfide - Zinc
Code 7391-02
Individual Test Kits
Order Code
Test System
(Detailed On Pages 6-7)
Range/Sensitivity
# of Tests
(# Reagents)
Reagent Refill
Oder Code
Shipping Code
(Weight/Lbs)
SULFIDE Both kits use the Pomeroy methylene blue method for analysis. The colorimetric method uses color standards to read total sulfide.
Total, dissolved and hydrogen sulfide can be separated in the titration test. The total sulfide is determined using a color dye which is added to an unreacted sample until it matches a reacted sample. The same procedure is used for dissolved sulfide, after insoluble matter is removed by aluminum floc. Hydrogen sulfide is determined by measuring pH and multiplying the dissolved sulfide concentration by a pH correction factor.
4456-01 Total Sulfide
0.2, 0.5, 1.0, 2.0, 5.0, 10.0, 15.0, 20.0 ppm S
2
50 (3) R-4456-01 R1 (1)
Octa-Slide 2 Comparator
4630†* Total, Dissolved &
Hydrogen Sulfide
1 drop = 1.0 or 0.1 ppm S2 or H
S 70 at 10 ppm (8) R-4630†* LQ (10)
2
Dropper Pipet
SULFITE An iodide-iodate titrant oxidizes sulfite to sulfate under acid conditions, until all of the sulfite is reacted. The titrant then reacts with
starch to form a blue color signifying the endpoint.
2
7175-DR-01 Direct Reading Titrator 0–100 ppm/2 ppm SO
7175-01 Dropper Pipet 1 drop = 5 ppm SO
3
2
3
7132-01 Dropper Bottle 1 drop = 2, 5, or 10 ppm SO
2
3
50 at 100 ppm
(3)
50 at 100 ppm
R-7175-
DR-01
R-7175-01 R1 (1)
(3)
100+ (3) R-7132-01 R1 (1)
R1 (1)
TANNIN/LIGNIN Tungstophosphoric and molybdophosphoric acids are reduced by tannins and lignins to form a blue color.
7831-01 Octa-Slide 2 Comparator 1, 2, 3, 4, 5, 6, 8, 10 ppm Tannin or lignin like
50 (2) R-7831-01 R1 (1)
substances
TOLCIDE PS BIOCIDE This kit was developed in cooperation with Solvay, for the determination of tetrakishydroxy-methyl phosphonium sulfate
(THPS). The iodometric titration may be used for fresh or salt water in oilfields, towers, pulp and paper, etc.
4-8776-01 Direct Reading Titrator 0-100/2 ppm THPS 60 (5) R-4-8776-01 NH (1)
ZINC In a solution buffered to pH 9, zincon reacts with zinc to form a blue color.
7391-02 Octa-Slide 2 Comparator 0, 1, 2, 3, 4, 6, 8, 10 ppm Zn 50 (2) R-7391-02 NH (1)
7417-02 Octa-Slide 2 Comparator 0, 0.2, 0.4, 0.6, 0.8, 1.0, 1.2, 1.4 ppm Zn 50 (2) R-7417-02 NH (1)
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com 55
Page 56
Aquaculture & Aquarium Waters
Fish Farms, Hatcheries, Research, Hobbyists, Retailers, Ornamental Fish Culturists...
Fresh Water Outfit

Combination Kits

Factor Method Range (# of Tests)
Ammonia Nitrogen Nessler 0.2–3.0 (50) Nitrite Nitrogen Diazotization/Coupling 0.05–0.8 (50)
pH Wide Range 5.0–10.0 (50)
Model AQ-2, Order Code 3633-04 (Ship Code R3; 16 lbs.) Reagent Refill, Order Code R-3633-03 (Ship Code R3)
A complete outfit for pond fish culture, ideal for fresh water analysis. Nine critical test factors can be determined on-site, efficiently and accurately. Designed with field analysis as a priority; all reagents, components, and accessories are arranged in pre-drilled foam. Short form instructions are provided in a handy adhesive lid label for easy access. Long form instruction booklet provides detailed instructions and test kit diagram. Unit is sup­plied complete with labware, accessories, sampling bottle, and reagents.
Factor Method Range (# Tests)
Alkalinity, Total Neutralization 0–200 ppm (50) Carbon Dioxide Neutralization 0–50 ppm (50) Chloride Argentometric 0–200 ppm (50) Dissolved Oxygen Azide Modification
of Winkler Method
Hardness (Total) Complexometric 0–200 ppm (50)
Temperature
Armored Thermometer –5° to 45°C
0–10 ppm (50)
Salt Water Outfit
Model AQ-4, Order Code 3635-04 (Ship Code R2; 16 lbs.) Reagent Refill, Order Code R-3635-03 (Ship Code R2)
Provides equipment to monitor nine parameters most critical for the salt water aquaculturalist. Reagents, labware, and accessories are mounted in foam for convenient test selection and por­tability. Short form lid label instructions are always available for quick reference, and a long form booklet provides detailed instructions with kit diagram. Unit is supplied complete with labware, accessories, sampling bottles, and reagents.
Factor Method Range (# of Tests)
Alkalinity* Neutralization 0–200 ppm (50) Carbon Dioxide Neutralization 0–50 ppm (50)
Dissolved Oxygen Azide Modification
of Winkler Method
Salinity Argentometric 0–20 ppt (50)
*Often referred to as carbonate hardness in aquarium industry.
Factor Method Range (# of Tests)
Ammonia Nitrogen Salicylate 0.05–2.0 ppm (50) Nitrate Nitrogen Cadmium Reduction 0.25–10.0 pm (40) Nitrite Nitrogen Diazotization/Coupling 0.05–0.8 ppm (50) pH Wide Range 5.0–10.0 (50)
Factor Range Sensitivity
Armored Thermometer –5° to 45°C 0.5°C
0–10 ppm (50)
56
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
Page 57
Elementary, Secondary, Vocational, Outdoor, & College Science
Water Quality Educator Monitoring Outfit
Order Code 5870-01 (Ship Code R1; 14 lbs.)
Always the first kit recommended for beginning a water quality monitoring study. The Water Quality Educator and Monitoring Outfit provides kits for seven basic water quality test factors and excep­tional support material, all housed in a rugged field carrying case.
The Monitor’s Handbook, a 71-page reference guide, includes all the information needed to set up a water quality monitoring program. The handbook covers test procedures and means to interpret results.
The Water Quality Educator CD-ROM, now for PC and Macintosh computers, incorporates Quick TimeTM animations, still photos, written and audio information to provide step-by-step instructions for the tests included. Students receive both visual and verbal instructions and can repeat material as often as necessary. This effective “pre-lab” activity helps prepare students for water quality testing in the field or in the classroom.
The CD also provides benchmark data for each test factor for comparison of results obtained us­ing LaMotte test kits in the field. Students enter their results and receive information on what type of water quality is indicated by their data as well as typical causes and effects of higher and lower levels.
Combination Kits
Environmental Studies
Factor Range (# Tests)
pH pH 3.0–10.5 (100) Nitrate-Nitrogen 0–15 ppm (50) Phosphate 0–2.0 ppm (50) Dissolved Oxygen 0–10.0 ppm (50) Alkalinity, Total 0-200 ppm (50) Turbidity 0-200 JTU (50) Temperature –5° to 45°C
Leaf Pack Experiments Stream Ecology Kit
Order Code 5882 (Ship Code NH; 10 lbs.)
Students performing the Leaf Pack Experiments learn to design, implement, and analyze a scientific investigation by discovering how aquatic macroinvertebrates indicate the overall health of a stream ecosystem. The Leaf Pack Experi­ments Kit is totally reusable and flexible. Adaptable to varying time constraints, number of students, and grade levels, it is geographically friendly and complete. All the apparatus and guides necessary for collecting, sorting and identifying are included. The kit includes a comprehensive Instructor’s Manual - featuring background material on stream ecology, a glossary, diagramed instructions, experiment ideas, and full color macroinvertebrate flash cards. Developed by the
Stroud Water Research Center in cooperation with LaMotte Company.
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
57
Page 58
Environmental Studies
Elementary, Secondary, Vocational, Outdoor & College Science
Plankton Net
15” (38.1 cm) tall, 5” (12.7 cm) dia. mouth
Combination Kits
Order Code 1063; (2 lbs.)
Cone-shaped net of 10 mesh, 153 micron nylon cloth. Minute plankton are collected and can be observed in the removable, clear conical graduated tube. Two tubes provided. Net mouth is braced by a sturdy stainless steel ring and harness.
Kick-Net
Kick-Net, complete with poles
Order Code 0021-P (8 lbs.) Kick-Net only Order Code 0021 (4 lbs.)
This 1x1 meter square, 500 micron, tan mesh net is designed to meet the requirements of groups per­forming US EPA Rapid Bioassessment Protocols for benthic invertebrates.
Secchi Disk
Disk with black & white quadrants & calibrated line
Order Code 0171-CL (3 lbs.)
Weighted 20 cm diameter disk has a braided stretch-resistant line marked every half meter and at every meter up to 20 meters.
58
Marine Science OutfitLimnology Outfit
Code 5902-02 (Ship Code R1; 13 lbs.)
Reagent Refill Code R-5902-01 (Ship Code LQ; 4 lbs.)
A popular outfit for the testing and study of freshwater systems such as ponds, lakes, wetlands, rivers, streams, etc. This field-friendly outfit contains individual test mod­ules, water sampling bottles, three supplemental handbooks, and data sheets.
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
Comparator Tests
Factor Range (# Tests)
Nitrate­Nitrogen
Phosphate 0.2–1.0 ppm (50) pH 3.0–10.0 pH (50) Silica 0.5–10 ppm (50)
0.2–1.0 ppm (40)
Direct Reading Titrator Tests
Factor Range (# Tests)
Carbon Dioxide
Dissolved Oxygen
Hardness 0–200 ppm (50)
0–50 ppm (50)
0–10 ppm (50)
Code 5903-03 (Ship Code R1; 13 lbs.)
Reagent Refill Code R-5903-02 (Ship Code R1; 4 lbs)
For testing and study of saline systems – oceans, bays, salt marshes, etc. Includes the Lab
Manual for Marine Science, Investigating Water Problems
and data sheets.
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
Colorimetric Tests
Factor Range (# Tests)
pH 3–10 (50) pH 7.7–8.4 (50)
Titration Tests
Factor Range (# Tests)
Dissolved Oxygen
Hardness 0–200 ppm (50) Carbon
Dioxide Alkalinity 0–200 ppm (50) Salinity 0–20 ppm (50)
0–10.0 ppm (50)
0–50 ppm (50)
Page 59
Environmental Studies
Elementary, Secondary, Vocational, Outdoor, & College Science
The Tour Series
Each Tour is a complete, hands-on, science curriculum with safe, simple TesTabs® tablet tests. Each Tour includes lecture materials, illustrated hand­outs, teacher tips, test procedures, TesTab reagents, data sheets, and games to reinforce key concepts. The Tour Series is designed for grades 4 through 8 environmental science education. The Goal of the Tour series is for students to discover, examine, measure, and compare physical and chemical properties. Students learn basic analytical methods while performing a scientific investigation.
Shore Tour
Shore Tour, Order Code 5939 (Ship Code NH; 5 lbs.) Reagent Refill, Order Code R-5939 (Ship Code NH; 1 lb.)
Five units teach students through classroom lectures and activities how their everyday actions affect the ocean. Topics include an introduction to coastal ecosystems, oil spills, shoreline development and marine debris. Includes teacher tested activities from EPA, NOAA, and The Marine Mammal Center, links to activities and information from ocean experts, CD with printable handouts, data sheets, and more. Materials for 40 students working in groups.
Watershed Tour
Combination Kits
Watershed Tour, Order Code 5419 (Ship Code NH; 4 lbs.) Reagent Refill, Order Code R-5419 (Ship Code NH; 1 lb.)
A classroom-based tour of a virtual watershed, designed for teachers who are unable to visit a stream with their students. Students will “test” four stations along a river continuum to study how the river changes and how human activities can influence water quality. Developed by the Stroud Water Research Center in coop­eration with LaMotte Company. Materials for 30 students working in groups.
Topsoil Tour
Topsoil Tour, Order Code5425-01 (Ship Code NH; 4 lbs.) Reagent Refill, Order Code R-5425-01 (Ship Code NH; 1 lb.)
Investigate the physical and chemical properties of soil. Each student on the Topsoil Tour completes seven units while conducting his/her own soil tests for soil texture, pH, nitrogen, phosphorus, and potassium. Tablets and sample test bags for 50 students.
Pondwater Tour
Pondwater Tour, Order Code 5418 (Ship Code R1; 4 lbs.) Reagent Refill, Order Code R-5418 (Ship Code R1; 1 lb.)
A great introduction to the study and measurement of changes in the water quality of a lake, stream, pond, aquarium, or even a fish bowl. Tests are included for pH, dissolved oxygen, nitrate, and ammonia. Students test variables and investigate natural processes that create changes in water quality. Tablets and sample test bags for 50 students.
Tapwater Tour
Tapwater Tour, Order Code 3608 (Ship Code NH; 4 lbs.) Regent Refill, Order Code R-3608 (Ship Code NH; 1 lb.)
An exciting investigation of water quality examining the chemical properties of water directly from the tap. Students learn the relationships between good and poor water quality while examining the pH, chlorine, hard­ness, copper, and iron of tapwater from their homes. Tablets and sample test bags for 50 students. Ideal for educational outreach for public health/utilities.
Call For Our Science Education Products Catalog
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
59
Page 60
Environmental Studies
Elementary, Secondary, Vocational, Outdoor & College Science
AP® Water Quality Assessment Package
Order Code 5845-PKG (Ship Code NH (1)
The AP® Environmental Science WATER QUALITY ASSESSMENT PACKAGE is an extensive curriculum that
Combination Kits
uses the exploration of the Water Quality Index to teach students STEM-based skills that they
will apply through classroom and field activities to satisfy Section VI (Water
Pollution) of the AP® Environmental Topics Outline.
In a culminating field activity, students utilize appropriate techniques and instrumentation to identify their watershed and perform chemi-
cal and biological analyses to determine the water quality index of
a local waterway.
The following environmental concepts are covered: water­sheds, Water Quality Index, physical, chemical and biologi-
cal water quality parameters, nutrient loading, hydrologi­cal variables, watershed ecology, remediation measures, and point, non-point pollution sources.
In four classroom activities, students use actual data from the Kansas River watershed to:
 Perform independent research  Analyze data  Create spreadsheets  Calculate the water quality index  Generate graphs  Collect data  Perform statistical analysis  Access real-time hydrological data  Locate local watersheds  Observe environmental systems  Communicate accurately
Water Quality Assessment Curriculum Module, Code 5845 (sold separately)
 Nutrient – TTC/MacConkey BioPaddles (Code 5553) for coliform
testing
 Salt/TDS/Temp Tracer (Code 1749-01) for temperature and TDS
determination
 Teacher Resource CD-ROM
The Teacher Resource CD-ROM (included with the Water Quality Index Module) contains:
 Teacher/Student guide  Water Quality Test Procedures  STEM Extension Activities  Chemical Reactions  Data Spreadsheets  Glossary  Graphics Files  PowerPoint Presentations and Quick Time iPad/iPod Videos
Also includes a Free LaMotte BioPaddle Colony Identification App which lets users capture the Bio­Paddle image to compare the “unknown” microbe growth on the BioPaddle to a library of photos of “known” microbe colonies.
Earth Force Low-Cost Water Monitoring Kit
Water Quality Educator, Code 5870-01 (See page 57)
 Thermometer, Armored, Code 1066  Dissolved Oxygen Kit, Code 5860-01  pH Kit, Code 5858-01  Nitrate-Nitrogen Kit, Code 3354-01  Phosphate Kit, Code 3121-02  Turbidity Kit, Code 7519-01  Alkalinity Kit Code 4491-DR-01
60
Order Code 3-5886 (Ship Code NH; 1 lb.)
A popular, economical tool for learning the basics of water quality. Students will have fun analyzing sample water for pH, Dissolved Oxy­gen, Biochemical Oxygen Demand, Temperature, Turbidity, Nitrate, Phosphate, and Coliform Bacteria. Includes a manual with step-by-step diagramed instructions and easy-to-use laminated color chart. All the necessary apparatus and non-hazardous TesTabs to test ten water samples (three samples for Coliform). Ideal for educational outreach.
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
Page 61
Dairy Producers, Food Processors, Commercial Launderers
Food Sanitizer Kits
For Caustic Soda
Model TK-10, Order Code 8225-01 (Ship Code R2; 2 lbs.) Reagent Refill, Order Code 8228-H (Ship Code R2; 2 lbs.)
This simple, single-reagent dropper pipet kit measures caustic soda for cleaning dairy bottles, cans, storage tanks, etc. Reagents for 50 tests. Kit uses neutralization test method. Dilution step permits measurement of two ranges:
 0.25%/drop caustic soda by weight  0.01%/drop sodium oxide
Also Available...
Factor
Sulfuric Acid
Chlorine 4497-01 Iodometric 10 ppm/drop (50) R2 Chlorinated
Cleaner
Order Code Method
8205 Neutralization 0.05 oz. per gal/drop
8226-01 Neutralization 0.01% NaOH/drop
Range (# Test)
(50)
(50)
Ship
Codes
R2
R2
Combination Kits
Food/Laundry
Standard pH Test Papers
Order Code pH Range Order Code pH Range
2907 6.8–8.4 2954 0–13 2912 3.0–10.0 2956 1–11 3-2950 0-14 2959 8–12 2953 4.5–7.5
Sanitizer Test Papers and Strips
Chemically treated paper strips change to indicate sanitizer level. Strips and color chart are packaged in a waterproof plastic vial. 2951 is specifically formulated to read all types of QAC.
Test Papers
Factor Code (Qty.) Range
Chlorine 4250-BJ (200) 10, 50, 100, 200 ppm
Iodine 2948-BJ (200) 12, 25, 50, 100 ppm
QAC 2951 (100) 50, 100, 200, 400 ppm
High Range QAC 2951-HR (50) 200, 400, 600, 1000, 1500 ppm
Look for additional chlorine, iodine, & QAC kits
in the Individual Test Kit section
Test Strips (50 test per vial)
Factor Code (Qty.) Range
Peracetic Acid 3000 (50) 0, 10, 20, 40, 60, 85, 160 Peracetic Acid,
Low Range Peracetic Acid,
High Range QAC 3072-J (100) 0, 100, 200, 300, 400, 500 ppm High Range Chlorine 3031 (50) 0, 50, 100, 250, 500, 800 ppm Dual Range QAC 2934 (50) LR: 0, 10, 20, 40, 80 ppm
3000LR (50) 0, 5, 10, 20, 30, 50
3000HR (50) 0, 50, 100, 250, 500, 1000
HR: 0, 100, 200, 400, 800 ppm
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
61
Page 62
Food/Laundry
Dairy Producers, Food Processors, Commercial Launderers
Combination Kits
Laundry Outfit
For control of water supplies, cleaning operations, and rinses
Model LDR, Order Code 3095-02 (Shipping Code LQ)
Seven important factors for monitoring incoming water supplies, break, suds and bleach operations; also rinse and sour operations. The pH (alkaline) test uses a LaMotte Octet Comparator. The al­kalinity tests, chlorine bleach and hardness test utilize dropper pipet test methods. Reagents are supplied for 50 tests of each factor.
Factor Range Application
pH (Alkaline) pH 10.0–11.4 Break-suds-bleach solutions pH (Sour) pH 1.5–8.5 Sour rinse solutions Alkalinity
(Suds) Alkalinity
(Rinse)
100 ppm/drop Free/total alkalinity in
break-suds-bleach solutions
10 ppm/drop Total alkalinity in rinses
Also Available...
Code Description Ship Codes
7250-02 P Alkalinity 1 drop = 10 ppm or 100 ppm
7196-01 Chlorine 1 drop = 10 ppm
3541-01 Spot test for presence/absence of Chlorine
7894-01 High Range–1 dr = 0.5% Cl
Total Hardness 1 drop = 1 gpg Chlorine Strips 10, 50, 100, 200 ppm
Oxygenated Bleach 1 drop = 10 ppm
and Iron. Wide Range pH
Mid Range–1 dr = 0.05% Cl2 Low Range–1 dr = 0.005% Cl
2
2
R2
R2
R1
R1
Factor Range Application
Chlorine Bleach 0.5%/drop Available chlorine in bleach
Hardness 10 ppm or
1 gpg/drop
Turbidity Yes/No (Soil) Presence of soil in solution
solutions Water Supply
62
7250-01
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
Page 63
General Water Analysis
Laboratories, Government Agencies
SMART Water Analysis Laboratory
MODEL SCL-05, Order Code 1951-02 (Shipping Code LQ; 37 lbs.) Reagent Refill, Order Code R-1951 (Shipping Code LQ; 10 lbs.)
This portable lab measures 24 water quality parameters for pollution detection, environmental studies, and industrial water and wastes. The SMART3 digital colorimeter analyzes test sample color reactions and provides direct readouts for 15 factors. Titration tests performed with LaMotte’s Direct Reading Titrators provide results directly in ppm for 6 additional factors. Digital meters measure pH and conductivity.
See specifications on next page.
Combination Kits
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
63
Page 64
General Water Analysis
Laboratories, Government Agencies
Colorimeter Tests
Factor Method Range (# Test)
Ammonia Nesslerization 0–4.0 ppm (50)
Combination Kits
Chlorine DPD 0–4.0 ppm (100) Bromine DPD 0–9 ppm (100) Iodine DPD 0–16 ppm (100) Chromium
(Hexavalent) Copper Diethyldithiocarbamate 0–6.0 ppm (100) Fluoride SPADNS 0–2.0 ppm (50) Iron Bipyridyl 0–6.0 ppm (50) Nitrate Cadmium Reduction 0–3.0 ppm (20) Nitrite Diazotization/Coupling 0–0.8 ppm (20) Phosphate Ascorbic Acid Reduction 0–3.0 ppm (50) Silica Heteropoly Blue 0–4.0 ppm (50) Sulfate Barium Chloride 0–100 ppm (50) Sulfide Methylene Blue 0–1.5 ppm (50) Turbidity Absorption (No Reagents)
Diphenylcarbazide 0–1.0 ppm (100)
0–400 NTU (¥)
Titration Tests
Factor Method Range (# Test)
Alkalinity Neutralization 0–200 ppm
Carbon Dioxide Neutralization 0–50 ppm
Chloride/Salinity Argentometric 0–200 ppm
Dissolved Oxygen Azide Modification
Hardness (Calcium, Magnesium, & Total)
of Winkler Method Complexometric 0–200 ppm
(50 at 200 ppm)
(50 at 50 ppm)
50 at 200 ppm) 0–10 ppm
(50 at 10 ppm)
(50 at 200 ppm)
pH/Conductivity Instruments
Factor Code Model Range # Test)
pH 5-0034-01 pH5 pH 0–14 Conductivity 5-0038-02 CON5 0.0–19.99 mS
Also Available...
Description
Model SMART 3 Colorimeter, without pH & Conductivity Lab Meters
Reagent Refill R-1991 LQ (10 lbs.)
Code
1991-01 SCL-04 LQ (34 lbs.)
Model
Ship Code (Wgt.)
64
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
Page 65
Industrial Waters
Water Treatment Companies, Engineers, Consultants
Combination Buret Outfits
In addition to our other standard products, LaMotte also packages combination buret style outfits. These outfits are packaged in cases made of rugged ABS plastic in sizes to fit three to five burets and accessories. The automatic burets and accessories are mounted in plastic clips over a white plastic workshelf in one half of the cabinet. The other half of the case is equipped with foam-lined shelves to hold additional tests or accessories. Colorimetric and titrimetric tests may be added to the buret titrations.
To order, simply choose the desired test reagents from the list on page 66 and select any additional tests from the A - Z section (pages 39-55) or the instrumentation section (pages 8-33). Squeeze valve (pinchcock) style burets are standard equipment with these kits, but glass or Teflon® stopcock burets may be ordered for an additional charge.
Combination Kits
Model AB-152
Order Code 7643-01 (Ship Code LQ)
Factor Method Equivalence (# Tests)
pH Alkaline Wide
Phosphate Stannous
Factor Method Equivalence (# Tests)
Alkalinity Neutralization 1 mL = 1.0 mg (50+) Chloride Argentometric 1 mL = 0.5 mg (50+) Hardness Complexometric 1 mL =6 0.25 mg (50+) Sulfite Iodometric 1 mL = 1.0 mg (50+)
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
Range
Chloride
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
pH 8.5–12 (50+)
0–10 / 0–100 ppm (50+)
Model AB-153
Order Code 7644-02 (Ship Code LQ)
Factor Method Equivalence (# Tests)
Molybdenum Xanthate 1–10 ppm Sodium Molybdate (50+) pH Phenol Red pH 6.8 – 8.2 (50+) pH Alkaline Wide Range pH 8.5 – 12 (50+) Phosphate Stannous Chloride 0–10 / 0–100 ppm (50+)
Factor Method Equivalence (# Tests)
Alkalinity Neutralization 1 mL = 1.0 mg (50+) Chloride Argentometric 1 mL = 0.5 mg (50+) Phosphonate Complexometric 1 mL = 0.2 mg (50+) Sulfite Iodometric 1 mL = 1.0 mg (50+)
65
Page 66
Industrial Waters
Water Treatment Companies, Engineers, Consultants
Industrial Titration Reagents
Combination Kits
Factor Order Code Reagent
Alkalinity 2246 Phenolphthalein
2786 Total Alkalinity Indicator 6068 Sulfuric Acid, 0.02N 6111 Sulfuric Acid, 0.1N
Chloride 4069 Chromate Indicator, 5%
8848 Silver Nitrate, 0.0282N 6346 Silver Nitrate, 0.0141N 6168 Silver Nitrate, 0.0171N
Hardness 4259 Ca Buffer (w/ metal inhibitors)
T-5250 Ca Indicator Tablets 4483 Total Buffer (w/ inhibitor) 4484 Total Indicator Tablets 6261 EDTA, 0.01M
Sulfite 6385 Starch Acid Indicator Powder
7329 Iodide Iodate, N/40 6106 Iodide Iodate, N/80 4556 Iodide Iodate, N/63 8667 Iodide Iodate, N/126
Call Customer Service for assistance.
Dependable LaMotte reagents are
available in a wide variety of sizes.
66
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
Page 67
Pool & Spa Waters
Professionals, Public Operators, Private Owners
Combination Kits
 So simple, anyone can use it!  Just fill disk with sample and Spin  All test results in 60 seconds  Precise wet chemistry  Pre-measured reagents and sample amounts
For more information scan the code shown here or go to www.lamotte.com/spin for videos and more information.
Free Chlorine
(ppm)
Range 0 to 15 0 to 15 0 to 33.0 6.3 to 8.6 0 to 1200 0 to 250 5 to 150 0 to 3.0 0 to 3.0 0 to 60
Biguanide
(ppm)
Range 0 to 70 0 to 250 6.3 to 8.6 0 to 1200 0 to 250 0 to 3.0 0 to 3.0 0 to 60
Total Chlorine
(ppm)
Biguanide Shock
(ppm)
Bromine
(ppm)
WaterLink® Spin Lab
Code 3576
A revolutionary new in-store lab is here! Now let the innovative WaterLink® Spin photometer do all your pool and spa water testing for you. Just fill one unique Spin reagent disk with water and vital tests are done automatically.
In just 60 seconds all the test results are transferred into the DataMate 10 software on your com­puter and analyzed to display results and recommend precise treatment instructions. Remove the disk and you’re ready for the next customer.
This ground-breaking analysis system is so simple anyone can use it. Each sealed reagent disk contains the precise amount of reagent needed to run a complete series of tests. No measuring water, no mixing, no prep time or cleanup.
Chlorine Disk, Order Code 4330-H (50/pk)
pH
(pH)
Biguanide Disk, Order Code 4331-H (50/pk)
pH
(pH)
Calcium Hardness
(ppm)
Calcium Hardness
(ppm)
Total Alkalinity
(ppm)
Total Alkalinity
(ppm)
Copper
(ppm)
Cyanuric Acid
(ppm)
Iron
(ppm)
Copper
(ppm)
Borate (ppm)
(ppm)
Iron
Borate (ppm)
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
67
Page 68
Pool & Spa Waters
Professionals, Public Operators, Private Owners
Insta-TEST® Plus Strips
Combination Kits
The Insta-TEST® 3, PRO400, and 5-way pool and spa test strips are the only strips of their kind that do not require any specific waiting period. Just dip the strip in the pool or spa for accurate and reliable results. The 3-way test strip measures for Free Chlorine or Bromine, Alkalinity and pH all on one strip. The 5-way test strip measures Free Chlorine or Bromine, Total Chlorine, Alkalinity, pH and Total Hardness. Both are sold in vials containing 50 strips. The PRO400 provides 100 strips and measures the Free Chlorine or Bromine, Total Chlorine, pH and Alkalinity. The PopTop bottle features a patented desiccant liner cov­ering its base and sides, which provides substantially better moisture protection and eliminates the need for a loose desiccant bag. Another feature is the hinged cap, which eliminates the problem of loose caps getting wet. Each bottle has a 30 month shelf life. Individual units are available through local retailers, which can be found on our website www.lamotte.com/insta.
The Sodium Chloride Insta-TEST® strip is an easy one step procedure for measuring Sodium Chloride in salt-water pools. Just dip and read to get results in only 20 seconds. The strip measures salt water pool samples over the range of 1,500 to 5,000 ppm. Each bottle contains 50 strips in a convenient, black PopTop bottle. A desiccant liner inside the bottle protects the strips from moisture intrusion and UV light.
The Wide Range pH and Total Chlorine Insta-TEST® strip identifies how far out of range a pool or spa sample may be, before a variety of treatment chemicals and test reagents are consumed. The Wide Range strip provides quick and reliable results in just 15 seconds. The strips are designed to measure Total Chlorine from 0 to 50 ppm and pH from 4 to 10.
See pages 34-35 for additional test strips.
PopTop bottles make
®
Insta-TEST
strips
even easier!
68
Code
2976 Insta-TEST 3 Plus 0 to 10 0 to 20 0 to 240 6.2 to 9.0 12, 24 or 100 NH 2977 Insta-TEST 5 Plus 0 to 10 0 to 20 0 to 10 0 to 240 6.2 to 9.0 50 to 800 12 or 100 NH 2978 Insta-TEST PRO 400 Plus 0 to 10 0 to 20 0 to 10 0 to 240 6.2 to 9.0 12 or 100 NH 2998 Insta-TEST Salt 1500 to
2987-G Insta-TEST Wide Range
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
Model
pH/Total Chlorine
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
Free
Chlorine Bromine
0 to 50 4 to 10 12 NH
Total
Chlorine Alkalinity
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
pH
Total
Hardness Salt
5000
Case
Pack Size
12 or 100 NH
Ship
Code
Page 69
Professionals, Public Operators, Private Owners
DipCell Series
The LaMotte DipCell color comparator is available in a competitive lineup of kits for the pool operator and service pro.The DipCell comparator is simple to use. Just dip the comparator into the water to get a sample, add reagents, cap, mix, and read chlorine and pH immediately. Six color standards are provided for wide-range chlorine from 0.5-10.0 ppm. The six standards included for pH range from 6.8 - 8.2.
 A wide range chlorine DipCell measures Chlorine from 0.5 - 10 ppm  Removable wall dividers inside the carrying case permit an easy upgrade
to larger 60 mL reagent sizes
 “Handle-Top” carrying case is compact and rugged (7½” x 4½”)  Liquid DPD and Phenol Red offered in large volumes to do 144 or 288 tests  Color-coded instructions and reagents simplify analysis  Separate titration tube for Alkalinity and Hardness avoids cleaning pH cell before each test  Handbook included
Combination Kits
Pool & Spa Waters
Code/Model
7011-01/ DT-3
# of Tests
7013/DL-51 0.5-10.0 0.5-10.0 6.8-8.2 1 drop = 10 ppm 1 drop = 20 ppm Drop count Drop count 0-100 R1
# of Tests
7014/DL-60 0.5-10.0 0.5-10.0 6.8-8.2 1 drop = 10 ppm 1 drop = 20 ppm Drop count Drop count R2
# of Tests
Free
Chlorine
0.5-10.0 0.5-10.0 6.8-8.2 (This kit includes 50 DPD tablets for each Chlorine test) NH
50 50 144
144 144 144 70± 70± 70± 70± 50
288 288 288 140± 140± 140± 140±
Total
Chlorine
pH
Calcium Alkalinity
Calcium
Hardness
Acid Demand Base
Demand
Cya
Ship
Code
Pool MGR. Series
All Tablet • Octa-Slide
Our rugged all tablet kit for the public pool operator. The precise Octa-Slide Com parator system is used to comply with regulatory standards. The Pool MGR. Series includes diagramed instructions, saturation index calculator, water quality hand­book, and the eight-standard Octa-Slide Comparator system for chlorine and pH, all in a tough, blow molded carrying case. The Pool MGR. tablet series is supplied with sufficient tablet reagents for 50 tests for Free Chlorine, Total Chlorine, and pH. Tablet reagents for 20 tests are provided for Alkalinity, Hardness, and Cyanuric Acid.
-
Code/Model
3366-BR-01/PM-41-BR Bromine 0-10.0 6.8-8.2 60-400 60-400 Calc. NH 3366-01/PM-41 0.2-3.0 0.2-3.0 6.8-8.2 60-400 60-400 Calc. NH 3366-NJ-01/PM-41-NJ 0.5-10.0 0.5-10.0 6.8-8.2 60-400 60-400 Calc. NH 3368-01/PM-51 0.2-3.0 0.2-3.0 6.8-8.2 60-400 60-400
3368-NJ-01/PM-51-NJ 0.5-10.0 0.5-10.0 6.8-8.2 60-400 60-400 Calc. 0-100 NH 3368-ABC-01/PM-51-NJ 0.5-10.0 0.5-10.0 6.8-8.2 60-400 60-400 Acid/Base drop titration 0-100 NH
# of Tests
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
Free
Chlorine
50 50 50 20 20 Calc. From Alk test result 20 NH
Total
Chlorine
pH
Total
Alkalinity
Calcium
Hardness
Acid Demand
Calc.
Cyanuric
Acid
0-100 NH
Ship
Code
69
Page 70
Pool & Spa Waters
Professionals, Public Operators, Private Owners
PRO250
Combination Kits
Our professional water analysis kits are supplied in durable, cases for years of dependable service. Each unit features liquid reagent systems for chlo­rine and pH (capable of 280+ tests each). The liquid DPD reagent system is provided to monitor chlorine, while pH is tested with a single liquid indicator. Total Alkalinity, Calcium Hardness, Acid and Base Demand are analyzed with drop count titrations. Cyanuric Acid is measured by turbidity. The PRO250 PLUS outfit includes all of the above plus Copper and Iron tests.
Every PRO250 SERIES kit includes color-coded caps to prevent mixups and diagramed instructions to make testing a breeze. The Pool MGR. Water Quality
handbook and saturation index calculator are also included. See the chart below for specifications.
Code/Model
7001-NJ-01/ PRO250-NJ
7002-NJ-01/ PRO250 PLUS-NJ
# of Tests
Free
Chlorine
0.2-3.0 &
0.5 -10.0
0.2-3.0 &
0.5 -10.0 288 288 288 140+ 140+ 70 each 100 50 50
Total
Chlorine pH
0.2-3.0 &
0.5 -10.0
0.2-3.0 &
0.5 -10.0
6.8-8.2 1 drop =
6.8-8.2 1 drop =1
Total
Alkalinity
10 ppm
0 ppm
Calcium
Hardness
1 drop =
20 ppm
1 drop =
20 ppm
Acid & Base
Demand Cya Copper Iron
Drop count 0-100 R2
Drop count 0-100 0.1-1.0 0.1-1.0 R2
Ship
Code
ColorQ PRO 9 TESTAB® KIT
Model PRO 9, Order Code 2069 (Ship Code R1; 4 lbs.)
The unique, multi-test ColorQ hand-held photometer reads NINE pool and spa test factors directly on a digital display. Featuring an innovative dual­optic design, the ColorQ provides more accuracy and more test factors. The ColorQ eliminates the need to visually determine slight color variations or use look-up tables, thus taking the guesswork out of poolside water analysis.
Test Factor Range Method
Free Chlorine (DPD) 0-10.0 ppm Colorimeter Total Chlorine (DPD) 0-10.0 ppm Colorimeter Bromine (DPD) 0-22.0 ppm Colorimeter pH 6.5-8.5 pH Colorimeter Calcium Hardness 0-400 ppm Colorimeter Total Alkalinity 0-250 ppm Colorimeter Iron 0-3.0 ppm Colorimeter Copper 0-4.0 ppm Colorimeter Cyanuric Acid 0-125 ppm Colorimeter
70
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
Page 71
Pool & Spa Waters
Professionals, Public Operators, Private Owners
Combination Kits
DPD TesTabs
As the only North American manufacturer of DPD tablets, LaMotte has replaced traditional foil-on-foil strip packaging with blister-style foil packaging. The user can dispense each tablet into a small vial by pressing the tablet through the foil. This eliminates the need to manually tear open a foil packet and carefully dispense the tablet. The package carries the customary 10 tablets per strip in a compact 3.35” x 1.35” size. In addition to the convenient pack­age, the DPD #1R rapid dissolving formula for measuring Free Chlorine has been enhanced for faster dissolution. Listed below are visual grade tablets.
®
- All new packaging for easier use!
Tablet
Chlorine DPD #1 Rapid 6999A-H 6999A-J 6999A-M NH Chlorine DPD #3 Rapid 6905A-H 6905A-J 6905A-M NH Chlorine DPD #4 Rapid 6899A-H 6899A-J 6899A-M NH pH (Phenol Red) 6915A-H 6915A-J 6915A-M NH Alk Test 3920A-H 3920A-J 3920A-M NH Cyanuric Acid 6994A-H 6994A-J 6994A-M NH Calcium Hardness 6846A-H 6846A-J 6846A-M NH MPS-OUT
(Monopersulfate Eliminator)
Quantity/Order Code
50
6911A-H 6911A-J N/A NH
100
1000
Ship
Code
See page 31 for instrument tablets
DPD Liquid Reagents
The liquid alternative to DPD tablets can be used with existing LaMotte chlorine comparators or colorimeters. DPD 1A and DPD 1B are added to a 5 or 10 mL sample to test Free Available Chlorine. DPD 3 is added to the reacted sample to measure Total Chlorine. Liquid reagents are also available to measure pH, Hardness, Alkalinity, and Copper.
30 mL(1 oz.) Code Ship Code
DPD 1A P-6740-G NH DPD 1B P-6741-G R2 DPD 3 P-6743-G NH
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
60 mL (2 oz.) Code Ship Code
DPD 1A P-6740-H NH DPD 1B P-6741-H R2 DPD 3 P-6743-H NH
71
Page 72
Water & Wastewater
Municipal & Industrial Water & Wastewater Systems
HydraFrac Water Screening Kit
Order Code 7627 (Ship Code HF, R1; 25 lbs.)
The HydraFrac Water Analysis Test Kit is suitable for the measurement of possible residuals associated with oil and natural gas development processes,
Combination Kits
industrial activities, or agricultural operations in surface or groundwater. The test kit provides a simple, portable method for obtaining instant water quality data for 15 parameters that could be associated with groundwater and surface water contamination. Expandable to over 80+ tests using the SMART3 colorimeter (see page 8-9, 17-18 for more details about the SMART3).
72
Factor Method Range (# Tests)
Acidity Dropper Bottle 1 drop = 0.1 or 1% Alkalinity Test Strip 0 to 240 ppm (25) Ammonia Test Strip 0 to 6 ppm (25) Barium Barium Chloride 0 to 200 ppm (50) Chloride Argentometric 0 to 30 ppm (50) Chromium Diphenylcarbohydrazide 0 to 1 ppm (50) Hardness Test Strip 0 to 180 ppm (25) Iron Test Strip 0 to 5 ppm (25) Nitrate Test Strip 0 to 200 ppm (25) Nitrite Test Strip 0 to 10 ppm (25) pH Test Strip 0 to 14 pH (25) Sulfate Barium Chloride 0 to 100 ppm (100)
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
Factor Method Range (# Tests)
Instrumentation
Dissolved Oxygen Tracer Instrument 0 to 20 ppm pH/EC/TDS Tracer Instrument
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
0 to 14 pH; 0 to 19.99 mS; 0 to 999 ppm
Page 73
Municipal & Industrial Water & Wastewater Systems
STORMWatch MS4 Water Screening Kit
Order Code 7449 MS4 Water Screening Kit (Also available as individual reagent kits)
Order Code 7450 IDDE Accessory Kit
Instrumentation and reagent systems are currently available to provide a preliminary screening of storm water outflow, and determine whether it is contributing to the overall pollutant load as it relates to inorganic constituents. In many cases these measurements can be made near the source, using handheld instrumentation, test kits, and/or reagents.
Features
 Fast - Most tests can be completed in under 2 minutes  Easy - All kits and meters come with easy-to-follow instructions  Unique Design - All-in-one kit that puts your testing needs together in one
easy to transport carrying case!
Scan here to see our Stormwater MS4 Guidance video
Combination Kits
Water & Wastewater
Test Factor Range (# Tests)
Ammonia 1.0 to 8.0 ppm (50) Boron* 0 to 0.80 ppm (50) Chlorine* 0 to 4 ppm (144) Copper* 0 to 7 ppm (50) Fluoride* 0 to 2 ppm (50) Hardness 1 drop=10, 25 or 50 ppm (100) Phenols* 0 to 6 ppm (50) Potassium 6 to 50 ppm (100) Surfactants* 0 to 8 ppm (100)
*Only available in Order Code 7450
Meters Range
Color 0 to 200 cu Conductivity 0 to 199.9 µS/cm pH 0.00 to 14.00 pH Turbidity 0 to 500 FAU TDS 0 to 999 ppm
Corrosion Control Kit
Model CCK, Order Code 7436-01 (Ship Code R1; 7 lbs.) Reagent Refill, Order Code R-7436-01 (Ship Code R1)
By determining corrosive conditions in water supplies, this test kit supports a water supplier’s lead in drinking water abatement program. Each unit includes tests for P and T alkalinity, calcium hardness, temperature, pH, phosphates, and total dissolved solids. Calculate saturation index by the Langelier method to indicate the corrosive conditions in water supplies. The Model CCK Corrosion Control kit is packaged in a portable carrying case for on-site use.
Factor Method Range (# Tests)
Calcium Hardness Complexometric 0–200 ppm(50) P & T Alkalinity Neutralization 0–200 ppm (50) Orthophosphate Ascorbic Acid 0.5–10 ppm (50) Temperature ——— –5° to +45°C (Unlimited) Corrosion Index ——— By calculation via chart (50)
Meters Range
Waterproof pH 1 PockeTester 0–14 pH Waterproof TDS 1 PockeTester 10–1990 ppm
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
73
Page 74
Water Conditioning
Residential & Commercial Water Treatment Specialists
Customize Your Water Quality Sales Demonstrations. Choose the Softener that Meets Your Needs!
LaMotte Model AT-Q Digital and AT Visual series outfits are the most popular and effective sales tools for on-site demonstrations. The tests clearly demonstrate the benefits between untreated and treated water.
Combination Kits
AT-Q Digital Series
Featuring the ColorQ DW digital colorimeter
New digital versions
 New rugged case
with locks
 Fast & simple tests  More custom options  Competitive pricing
AT-Q with Model S •
Code 4-3051-01
AT-Q with DuoSoft •
Code 4-3055-01
AT-Q with DirectFlo •
Code 4-3071-01
AT-Q Digital Kit Tests (9 Included
Hardness pH Iron Nitrate
Range 1-41 gpg* 5-9 0-3.0 ppm* 0-25 0-10 ppm 0-3.0 ppm* Before/After Before/After Resolution 1 gpg 0.5 pH 0.5 1 ppm 0.2 ppm 0.2 ppm # of Tests 140 70 50 50 50 120 100 100
*Higher Concentrations by dilution; instructions included.
)
Chlorine Free & Total Sulfide Precipitation
AT-Q with DirectFlo
DuoSoft •
Code 4-3075-01
Soap Consumption
AT Visual Series
AT with Model S • Code 4-3003-02
AT with DirectFlo •
Code 4-3010-01
AT with DuoSoft •
Code 4-3015-01
AT with DirectFlo
DuoSoft •
Code 4-3018-01
74
AT Visual Kit Tests (5 Included
Hardness pH Iron Precipitation
Range 1 drop = 10 ppm/1 gpg 5.0-10 ppm 0.5-10* ppm Before/After Before/After
# of Tests 100 100 100 100 100
*Higher Concentrations by dilution; instructions included.
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
)
Soap Consumption
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
Optional Add-On Kits and TDS Meter:
Chlorine (0.2-3.0 ppm
Nitrate (0-15 ppm), 50 Tests; Code 4-3004
TDS Meter, Code 5-0080 (see page 26
),
50 Tests; Code 4-3006
)
Page 75
Residential & Commercial Water Treatment Specialists
Demonstration Softener Units
Combination Kits
Water Conditioning
TM
Model S
Order Code 1002
 Single chamber  Filled with resin
Duo-Soft
Order Code 1022
 Dual chamber  Shipped empty
Order Code 1022-FLD
 Dual chamber  Filled with carbon
and resin
Water Quality Outfit
Model AR-42, Order Code 3590-03 (Ship Code R1, 7 lbs.)
The simplest, most economical way to measure several water quality factors with a single, portable outfit. Ideal for service ap­plications. Easily customized for your particular analytical needs.
Tests for pH, hardness, iron, and sulfide. Includes reagents for 50 tests each for pH, hardness, and sulfide; 100 tests for iron.
Factor Method Range (# Tests)
pH Wide Range pH 5.0–10.0 (50) Iron Bipyridyl 0.5–10.0 ppm (100) Hardness Titration 1 drop = 10 ppm/1 gpg (50) Sulfide Pomeroy 0.2-20.0 ppm (50)
DirectFlo
Order Code 1026
 Hose Free  Single chamber  Filled with resin
DirectFlo DuoSoft
Order Code 1028
 Hose Free  Dual chamber  Filled with
carbon and resin
Please visit www.lamotte.com for details
Ship Codes: (NH) Non-Hazardous Material - No Fees • (R1) Small Qty. Hazardous Material - No Fees • (LQ, R2, R3) Hazardous Material - Air Fees Only • (HF) Hazardous Material - Air & Ground Fees
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
*(NPDWR) EPA Accepted • †(NPDES) EPA Accepted • Direct Reading Titrators have a specific range, but may be refilled to test higher concentrations.
75
Page 76
How to use this section:
Code# Suffix (Indicating Size) Size
The reagent code number is followed by a letter which indicates the con­tainer size supplied for that reagent. The following table shows how those letters correspond to container sizes - milliliters for liquids and grams
Reagent Refills
fo powder. When ordering a reagent, please include the appropriate let­ter suffix with the reagent code number to indicate the container size.
EXAMPLE: To order a 60 mL bottle of Phenol Red Solution (Reagent Code Number 2211), use the letter “-H”, and order by code number “2211-H”.
NOTE: A reagent is available only in the sizes indicated under the kit’s listing in this section.
How to Determine Reagent Manufacture and Expiration Dates
On the lower, left corner of the label of each LaMotte reagent is a six (sometimes seven), digit number. This is not a code number, but the lot number of that reagent. A lot number records the date of manufacture and identifies the reagent as part of a specific batch of reagent produced on that date. The first two digits of the lot number identify the week, and the third digit identifies the year of manufacture.
If the shelf-life of your reagent is unknown, one year from the date of manufacture is still a good rule of thumb.
6483-H
FIRST AID EYE OR SKIN Immediately flush with water for 15 minutes. INTERNAL- Drink plenty of water. Call a doctor. WARNING: This product contains Phenolphthalein, a chemical known to the State of California to cause cancer.
LOT 521109
802 Washington Ave., Chestertown, MD 21620 USA • 410-778-3100 • MSDS: lamotte.com/msds
Lot# (Including Week, Year, & Batch Information)
-A
1 1mL 1 gram
-B
2 2 mL 2 grams
-C
5 5 mL 5 grams
-D
10 10 mL 10 grams
-E
15 15 mL 15 grams
-F
20 20 mL 20 grams
-G
30 30mL 30 grams
-H
60 60mL 60 grams
-J
120 120mL 120 grams
-K
250 250-285mL 1200-500 grams
-L
500 470-525mL 450-500 grams
-M
1000 950-1000mL —-
-N
—- 3800mL —-
Conductivity Neutralizing
Solution
WARNING! FLAMMABLE
Read side panel before use.
60 mL
Read MSDS 39% Isopropanol, CAS 67-63-5; 5% Citric acid, CAS 77-92-9; <0.1% Phenolphthalein, CAS 77-.09-8. Harmful if swallowed or inhaled. Do NOT use near heat or flame. Avoid contact with eyes. Keep container tightly closed and out of reach of children.
Kit Code Reagent # Description
2036 2220-H Range Finding Indicator
2081-02 2218-G Wide Range
2212-G Cresol Red
2109-01 2210-G Bromthymol Blue
2110-01 2211-G Phenol Red
2111-01 2212-G Cresol Red
2112-01 2213-G Thymol Blue
2214-G Oleo Red B
2124-01 2303-G Alkaline Wide Range
3036 6410-E Ferroin
6411PS-H Nitrite DRT
3037-DR-01 4483-E Hardness 5
4257-H Hardness Titration
6522-E CM Indicator
3043-DR-01 6413-E QAC Indicator
6412-H Titration Reagent
3095-02 6434-H Hypochlorite Indicator
7941PS-H Hypochlorite Reagent C
2301-G Nitro Green Indicator
4483-E Hardness Reagent 5
4485-E Hardness Reagent 6
4487PS-H Hardness Reagent 7
2246-E Phenolphthalein
2230-E Methyl Orange Indicator
6130PS-H Hydrochloric Acid 1N
6323-H Hydrochloric Acid 0.1N
6432-H Sour Indicator
3110-01 V-6278-H Mixed Acid
V-6279-C Nitrate Reducing
3114-02 V-6282-G Phosphate Acid
V-6283-C Phosphate Reducing
3119-01 V-6278-J Mixed Acid
V-6279-C Nitrate Reducing
V-6282-H Phosphate Acid
V-6283-C Phosphate Reducing
3121-02 V-6282-G Phosphate Acid
V-6283-C Phosphate Reducing
3138-01 6364-C Tetraphenylboron
7745-E Sodium Hydroxide
3152-01 6155-E Sodium Thiosulfate
6165-D Xylenol Orange
6025-E Hydrochloric Acid
6158PS-H Thorium Nitrate
3160-01 6484-H Molybdenum Buffer
6485-H Molybdenum Oxidizing
6486-S Molybdenum Indicator
3176-02 6807-C DPD 1
6905-H DPD 3R
6815-G Ferrous Ammon. Sulfate
6495-E Control Reagent
76
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
Page 77
Reagent Refills
Kit Code Reagent # Description
3304-01 3978LWT-H Salicylate Ammonia #1
3979WT-G Salicylate Ammonia #2
3982WT-G Salicylate Ammonia #3
3308-01 6999-H DPD 1R
6905-H DPD 3R
3312-01 6999-H DPD 1R
6905-H DPD 3R
3313-01 6999-H DPD 1R
6905-H DPD 3R
3314-01 6999-J DPD 1R
6905-J DPD 3R
3316-01 6905-6999 DPD 1, DPD 3
6904-6906 DPD 2, DPD 4
3328-01 6999-H DPD 1R
6905-H DPD 3R
3346-01 3962-H Molybdate 1 HR
3963-H Molybdate 2 HR
3347-01 4450-G Iron Reagent 1
4451-S Iron Reagent 2 Powder
4453-S Ferrous Iron Reagent
3352-01 V-6278-J Mixed Acid Reagent
V-6281-C Color Developing Reagent
3354-01 2799-H Nitrate 1
NN-3703-H Nitrate 2
3363-01 6915-H Phenol Red
6905-6999 DPD 1, DPD 3
3363-NJ-01 6915-H Phenol Red
6905-6999 DPD 1, DPD 3
3366-01 6905-6999 DPD 1, DPD 3
6915-3box pH, Alk, Hard
3366-BR-01 6999-J DPD 1R
6915-3box pH, Alk, Hard
3368-01 6905-6999 DPD 1, DPD 3
3920-4box pH, Alk, Hard, CYA
3456-01
3467-01 3870-E Alkalinity Indicator 1
3869-E Alkalinity Indicator 2
4493DR-H Alkalinity B
3468-01 4069-E Chloride A
4070-H Chloride B
3509-03 4483-E Hardness Reagent 5
4484-J Hardness Reagent 6 Tablets
4487WT-H Hardness Reagent 7
4450-E Iron Reagent 1
4451-S Iron Reagent 2 Powder
2218 Wide Range Indicator
3519-01 V-6278-J Mixed Acid
V-6279-C Nitrate Reducing
V-6281-C Color Developing
Kit Code Reagent # Description
3541-01 6381-G Hydrochloric Acid
4100-G O-Tolidine
5116WT-G Ferric Iron Test
9078WT-G Sour Indicator
3569-01 3943-H Aluminum 1
3944-H Aluminum 2
3582-01 3951-E Lead A
3945-E Lead C
3946-J Lead Indicator
3588-02 4255-H Hardness Buffer
3956-G Manganese
6203-J Chloroform
2785-E Metal Inhibitor
3609-01 4259-E Sodium Hydroxide
T-5250-H Calcium Hardness
4487DR-H Hardness 7
3615-01 V-6278-K Mixed Acid
V-6279-D Nitrate Reducing
3619 P-6367-E Copper A
P-6368-E Copper B
3622-01 6903-H DPD #1 Tablets
6811-E Glycine Solution
3624-01 6807-C DPD 1
6905-H DPD 3R
3992DR-H Chlorine/Bromine
3628-01 7646-G Molybdenum Buffer
3632-01 3997-J MO Buffer
3998-H Denatured Alcohol
3999-H MO Titrant
4001-S Carbazone
3633-04 4797WT-G Ammonia Nitro. 1
4798WT-G Ammonia Nitro. 2
2218-G Wide Range, pH 3
V-6278-H Mixed Acid
V-6281-D Color Developing
2311-Eg-E BCG-MR Indicator
4493DR-H Alkalinity B
2246-E Phenolphthalein
4504-E Chloride 1
4505DR-H Chloride 2
6090-E Sulfuric Acid
4483-E Hardness 5
4485-E Hardness 6
4487DR-H Hardness 7
4169-H Sodium Thiosulfate
4167-G Mang. Sulfate
7166-G Alk. Pot. Iodide-Azide
6141WT-G Sulfuric Acid
4170PS-G Starch Indicator
4253DR-H Carbon Dioxide B
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
77
Page 78
Kit Code Reagent # Description
3634-04 4797WT-G Ammonia Nitrogen 1
V-6278-H Mixed Acid
Reagent Refills
3635-04 2218-G Wide Range pH 3
3639-SC 4004WT-G Sodium Hydroxide
3640-SC T-3808-H Copper Tablets
3641-01-SC 7865-C Aluminum Inhibitor
3642-SC V-4797-G Ammonia Nitro. 1
3643-SC 6903-J DPD 1
3644-SC 6903-J DPD 1
3645-SC V-6276-D Chromium Rgt.
3646-SC 6446-E Copper 1
3647-02-SC 3875-G Acid Zirconyl Spadns
V-6281-D Color Developing
2311-Eg-E BCG-MR Indicator
4493DR-H Alkalinity B
2246-E Phenolphthalein
4504-E Chloride 1
4505DR-H Chloride 2
6090-E Sulfuric Acid
4483-E Hardness 5
4485-E Hardness 6
4487DR-H Hardness 7
4253DR-H Carbon Dioxide B
4798WT-G Ammonia Nitro. 2
3978LWT-H Salicylate Ammon. 1
3979WT-G Salicylate Ammon. 2
3982WT-G Salicylate Ammon. 3
V-6278-J Mixed Acid
V-6281-C Color Developing
V-6279-C Nitrate Reducing
2311-Eg-E BCG-MR Indicator
4493DR-H Alkalinity Titration B
2246-E Phenolphthalein
4253DR-H Carbon Dioxide B
7460-E Salinity Indicator A
7461-H Salinity Titration B
4169-H Sodium Thiosulfate
4167-G Mang. Sulfate
7166-G Alkaline Pot. Iodide-Azide
6141WT-G Sulfuric Acid
4170PS-G Starch Indicator
6364-C Tetraphenylboron
7866-J Aluminum Buffer
7867-J Aluminum Indicator
7868-E Aluminum Complex.
V-4798-G Ammonia Nitro. 2
6197-J DPD 3
6811-E Glycine
6811-E Glycine
4128-G Sodium Arsenite
Kit Code Reagent # Description
3648-SC V-4450-G Iron 1
V-4451-C Iron 2
3649-SC V-6278-H Mixed Acid
V-6279-C Nitrate Reducing
3650-SC V-6278-H Mixed Acid
V-6281-C Color Developing
3651-SC 3989-G Indigo Blue Solution
3990-E Chlorine Inhibitor
3991-K Ozone Buffer
3653-SC V-6282-H Phosphate Acid
V-6283-C Phosphate Reducing
3654-02-SC V-4458-G Sulfide A
V-4459-E Sulfide B
4460-H Sulfide C
3655-SC 4410-H Phosphate Rgt.
3656-01-SC 4842-D Reagent B
4841-H Hydrazine A
3658-01-SC 3956-G Manganese Indicator
4255-G Hardness Buffer
6565-E Sodium Cyanide
3659-01-SC 3978-H Salicylate Ammon. 1
7457-D Salicylate 2
7458-C Salicylate 3
3660-01-SC 6130-E Hydrochloric Acid
4004-E Sodium Hydroxide
2850PS-H Cyanide Buffer
2794DS-C Cyanide CL
2793DS-C Cyanide Indicator
3661-01-SC 4856-K Cyanuric Acid Rgt.
3662-SC 6452-G Hydrogen Peroxide 1
6454 Hydrogen Peroxide Tabs
3663-01-SC 6251PS-H Hydrochloric Acid
6253-K Sodium Citrate
6254-H Dimethylglyoxime
6537-H Ammonium Hydroxide
6566-G Ammonium Pers
6346WT-G Silver Nitrate
3664-SC V-4466-G Silica 1
V-4467-G Silica 2
V-4468-G Silica 3
V-6284-D Silica 4
3665-SC V-6277-D Sulfate Rgt.
3666-01-SC 7833-G Tannin 1
7834-H Tannin 2
3667-01-SC 6314-G Zinc Indicator
6315-G Zinc Buffer
6565-E Sodium Cyanide
6316-D Sodium Ascorbate
5128-G Formaldehyde
6319-J Methyl Alcohol
78
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
Page 79
Reagent Refills
Kit Code Reagent # Description
3668-SC 2776-E Acid Phenanthroline
2777-C Iron Reducing
3669-SC 6310-D Manganese Buffer
6311-E Manganese Periodate
3670-01 6903-J DPD 1
6197-J DPD 3
3670-LI-01 P-6740-G DPD 1A
P-6741-G DPD 1B
P-6743-G DPD 3
3671-01 6903-J DPD 1
6811-E Glycine
3672-01 6903-J DPD 1
3673-01 6446-G Copper 1
3674-01 3875-J Acid Zirconyl SPADNS
4128-H Sodium Arsenite
3676-01 6485-G Molybden. Oxidizing
3997-H MO Buffer
6486-S Molybdenum Indicator
3677-01 V-6278-J Mixed Acid
V-6279-D Nitrate Reducing
3678-01 3989-G Indigo Blue Solution
3990-E Chlorine Inhibitor
3991-K Ozone Buffer
3679-01 V-6282-H Phosphate Acid
V-6283-D Phosphate Reducing
3680-01 V-4797-G Ammonia Nitrogen 1
V-4798-G Ammonia Nitrogen 2
3681-01 2776-E Acid Phenanthroline
2777-C Iron Reducing
3682-01 4255-J Hardness Buffer
3956-G Manganese Indicator
6565-E Sodium Cyanide
3683-01 V-6277-D Sulfate Rgt.
3687-SC V-4466-G Silica 1
V-4467-G Silica 2
4468-E Silica 3
3688-SC 4167-G Manganous Sulfate
7166-G Alkaline Pot. Iodide-Azide
6141WT-G Sulfuric Acid
3698-SC 7681-H Sulfuric Acid
V-6276-D Chromium Rgt.
7683-E Sodium Azide
7682-G Potassium Permanganate
5115PT-H Deionized Water
3699-03-SC 3997-G MO Buffer
6485-G Molybdenum Oxidizing
6486-S Molybdenum Indicator
3700-01-SC V-2209-H TRL Chlorphenol Red
V-2304-H TRL Phenol Red
V-2213-H TRL Thymol Blue
Kit Code Reagent # Description
4-3003-01 4450-G Iron 1
4451-S Iron 2
2218-G Wide Range Indicator
4767-H Soap 4
4542-H Precip A
4543-H Precip B
4483WT-H Hardness 5
4484-J Hardness 6
4487WT-H Hardness 7
4-8776-01 4133 DSP Reagent 10%
4135 Borate Buffer
4134 PSSA Reagent 5%
4170 Starch Indicator
6377 Iodine Solution 0.025N
3843 Zinc Acetate 2.0N
4031-01 4032 Ammonia Chloride Buffer
6565 Sodium Cyanide 10%
4033 PAR Indicator
4022 Stabilizing Reagent
4401-02 4410-G VM Phosphate
4408-01 6405-G Reducing Rgt.
4410-H VM Phosphate
4430-01 4431-G Chromate Indicator
4447-01 4450-G Iron 1
4451-S Iron 2
4456-01 4458-G Sulfide A
4459-E Sulfide B
4460-H Sulfide C
4463-01 4571-G Silica 1
4467-E Silica 2
4468-E Silica 3
6405-C Reducing Rgt.
4482-DR-LI-01 4483-E Hardness 5
4485-E Hardness 6
4487DR-H Hardness 7
4482-DR-LT-01 4483-E Hardness 5
4484-J Hardness 6
4487DR-H Hardness 7
4482-LI-02 4483-E Hardness 5
4485-E Hardness 6
4487WT-H Hardness 7
4482-LT-02 4483-E Hardness 5
4484-J Hardness 6
4487WT-H Hardness 7
4491-DR-01 T-2311-H BCG-MR Indicator
4493DR-H Alkalinity Titration B
4497-01 4498WT-H Chlorine 1
4499WT-H Chlorine 2
4500PA-H Chlorine 3
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
79
Page 80
Kit Code Reagent # Description
4497-DR-01 4498WT-H Chlorine 1
4499WT-H Chlorine 2
Reagent Refills
4501-01 4498-E Chlorine 1
4503-DR-02 4504-E Chloride 1
4507-02 4508-G DS Indicator
4515-01 7444-H Detergent Reagent 1
4533-01 T-2246-J Phenolphthalein
4533-DR-01 T-2246-J Phenolphthalein
4630 4633-H Sulfide Test 1
4766
4783-03 4483-E Hardness 5
4790-01 4791-E DEHA 1
4801-DR-01 4802DR-H TDS A
4824-DR-LT-01 4259-E Sod. Hydroxide
4500DR-H Chlorine 3
4499-E Chlorine 2
3819-H Sodium Thiosulfate
2246-E Phenolphthalein
6090-E Sulfuric Acid
4505DR-G Chloride 2
4509-H pH Adjustment
4513-E DS Reference
6037-J Detergent Reagent 2
7445-J Detergent Reagent 3
T-2311-J BCG-MR Indicator
4493PS-H Alkalinity Titration B
T-2311-J BCG-MR Indicator
4493DR-H Alkalinity Titration B
4634-H Sulfide Test 2
4635-H Sulfide Test 3
4636-H Sulfide Test 4
4636-J Sulfide Test 4
4637-S Sulfide Test 5
4638-S Sulfide Test 6
4639-H Sulfide Test 7
4640-H Sulfide Test 8
4484-J Hardness 6
4487WT-H Hardness 7
4450-G Iron 1
4451-S Iron 2
2218-G Wide Range
4792-E DEHA 2
4793-E DEHA 3
4803DR-H TDS B
2299-E Methyl Orange
T-5250-H Calcium Hardness
4483-E Hardness 5
4484-J Hardness 6
4487DR-H Hardness 7
Kit Code Reagent # Description
4824-LT-02 4483-E Hardness 5
4484-J Hardness 6
4487WT-H Hardness 7
4259-E Sod. Hydroxide
T-5250-H Calcium Hardness
5858-01 2218-G Wide Range Indicator
5860-01
5864-01 3968A-H Ammonia #1 Tab
3969A-H Ammonia #2 Tab
5921-03
6616-01 6446-E Copper 1
6628-01 6630-D Molybdenum Rgt.
6381-G Hydrochloric Acid
6701-01 6697-J Formaldehyde 1
6698-C Formaldehyde 2
6699-J Formaldehyde 3
6824-01 6811-E Glycine
6905-H DPD 3R
6977-J Bromine Tablets
6896-01 6999-J DPD 1R
6915-H Phenol Red
6955-01 6977-H Bromine Tablets
6980-01 6999 DPD 1R
6904 DPD 2R
6905 DPD 3R
6899 DPD 4R
6915 Phenol Red
7001-NJ-01 P-6740-H DPD 1A
P-6741-H DPD 1B
P-6743-H DPD 3
P-7026-H Phenol Red
6994-J Cyanuric Acid
P-7028-G Alk 1 Indicator
P-6111-H Alk Titrant
P-4259-H Hard 1
P-7030-G Hard 2
P-7031-H CaHard Titrant
P-6068-E Acid Demand
P-6460-E Base Demand
7611 6117-G Barium Chloride 10%
80
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
Page 81
Reagent Refills
Kit Code Reagent # Description
7002-NJ-01 P-6740-H DPD 1A
P-6741-H DPD 1B
P-6743-H DPD 3
P-7026-H Phenol Red
6994-J Cyanuric Acid
P-7028-G Alk 1 Indicator
P-6111-H Alk Titrant
P-4259-H Hard 1
P-7030-G Hard 2
P-7031-H CaHard Titrant
P-6068-E Acid Demand
P-6460-E Base Demand
P-4450-E Iron 1
T-4451-H Iron 2
P-6446-E Copper 1
7011-01 6905-6999 DPD 1, DPD 3
P-7026-G Phenol Red
7013 P-6740-G DPD 1A
P-6741-G DPD 1B
P-6743-G DPD 3
P-7026-G Phenol Red
6994-HRB Cyanuric Acid
P-6068-E Acid Demand
P-6460-E Base Demand
P-7028-G Alk 1 Indicator
P-6111-G Alk Titrant
P-4259-G Hard 1
P-7030-G Hard 2
P-7031-G CaHard Titrant
7014 P-6740-H DPD 1A
P-6741-H DPD 1B
P-6743-H DPD 3
P-7026-H Phenol Red
P-6068-G Acid Demand
P-6460-G Base Demand
P-7028-G Alk 1 Indicator
P-6111-H Alk Titrant
P-4259-H Hard 1
P-7030-G Hard 2
P-7031-H CaHard Titrant
7056-01 7125-H Polyquat Titrating
2258-E Phenolphthalein
6090-E Sulfuric Acid
3995-G Toluidine Blue O
7117-H EDTA
7057-01 3996-H Quat Titrating
3995-G Toluidine Blue O
7117-H EDTA
2258-E Phenolphthalein
6090-E Sulfuric Acid
Kit Code Reagent # Description
7064-01 6289-H Sulfuric Acid
6289WT-H Sulfuric Acid
5168-J Sodium Hydroxide
2246-E Phenolphthalein
7114-H Glut. Test Powder
5175PT-K Distilled Water
7068-01 4606-H Phosphate A
4607-J Phosphate B/C
7101-01 7102-G Nitrite 1
7103PS-H Nitrite 2
7101-DR-01 7102-G Nitrite 1
7103DR-H Nitrite 2
7105-03 7939PS-G Hypochlorite A
2790-H Hypochlorite D
6809-D Potassium Iodide
7132-01 2258-E Phenolphthalein
6385-D Starch Acid
2779WT-H Iodide Iodate
7138-DB-01 6809-D Potassium Iodide
4170WT-G Starch Indicator
7139-H Peroxide Titrant
7140-H Acidified Catalyst
7143-01 2780-D T.C. Indicator
6025-H Hydrochloric Acid
2781WT-H T.C. Titrant
7144-01 4483-G Hardness 5
4485-E Hardness 6
2782WT-H Free Chelant Titrant
7150-01 6809-D Potassium Iodide
4170WT-G Starch Indicator
7456WT-H Peroxide Titrant
7140-H Acidified Catalyst
7171-02 4483WT-G Hardness 5
4485-G Hardness 6
2783WT-H Hardness 10
7172-02 6091WT-G Hydrogen Peroxide
4069WT-G Chloride A
6090WT-G Sulfuric Acid
2258-E Phenolphthalein
3824WT-G Silver Nitrate
7175-01 7327-E Sulfite A
7328-E Sulfite B
7329PS-H Sulfite C
7175-DR-01 7327-E Sulfite A
7328-E Sulfite B
7329DR-H Sulfite C
7181-01 5649WT-G Hydrochloric Acid
2258-E Phenolphthalein
6117-G Barium Chloride
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
81
Page 82
Kit Code Reagent # Description
7182-01 5648-G Sodium Hydroxide
2258-E Phenolphthalein
7183-02 6410-E Ferroin
Reagent Refills
7191-02 6141WT-G Sulfuric Acid
7196-01 6434WT-G Hypochlorite
7240-02 2258-E Phenolphthalein
7246-02 2788WT-G Hardness 2
7247-01 6091WT-G Hydrogen Peroxide
7250-02 2246-G Phenolphthalein
7253-01 7254-E Iodine 1
7253-DR-01 7254-E Iodine 1
7297-DR-01 2246-E Phenolphthalein
7340-R-01 7342-H PPK A
7387-02 6130-E Hydrochloric Acid
7391-02 7393-G Zinc Rgt.
2789WT-G Can Solution
6410-E Ferroin
5650LWT-G Hydrogen Peroxide
6521-G Potassium Iodide
S-6155-H Peracetic Acid Titrant
4500WT-H Chlorine 3
6452-G Hydrogen Peroxide 1
2786-E Total Alkalinity
7748WT-G Sulfuric Acid
4483WT-G Hardness 5
4485-G Hardness 6
4069WT-G Chloride A
6090WT-G Sulfuric Acid
2258-E Phenolphthalein
6421WT-H Silver Nitrate
4250-BJ Chlorine Test Papers
4483-G Hardness 5
4485-G Hardness 6
2783WT-H Hardness 10
6323WT-H Hydrochloric Acid
6130WT-H Hydrochloric Acid
7255-E Iodine 2
6406PS-H Iodine 3
7255-E Iodine 2
6406DR-H Iodine 3
4253DR-H Carbon Dioxide B
7343-H PPK B
7344-H PPK C
4004-E Sodium Hydroxide
2850PS-H Cyanide Buffer
2794DS-C Cyanide CL
2793DS-C Cyanide Indicator
2955 pH Test Paper
7361-E Zinc Conditioning
Kit Code Reagent # Description
7416-02 4410-G VM Phosphate
6405-G Reducing Rgt.
7417-02 7393-G Zinc Rgt.
7361-E Zinc Conditioning
7436-01 3870-E Alkalinity 1
3869-E Alkalinity 2
4493DR-H Alkalinity Titration B
4259-E Sod. Hydroxide
T-5250-H Calcium Hardness
4487DR-H Hardness 7
V-6282-H Phosphate Acid
V-6283-C Phosphate Reducing
2881-H pH 7.00 Buffer
7446 6446-G Copper 1
6899-J DPD 4R
7825-D Aminoantipyrine
7826-H Ammonium Hydroxide
7827-J Pot. Ferricyanide
7444-H Detergent 1
6037-J Detergent 2
7445-J Detergent 3
7459-02 7460-E Salinity A
7461DR-G Salinity B
7514-01 6807-C DPD 1
6905-H DPD 3R
3992WT-H Chlorine/Bromine
7515-01 T-2246-J Phenolphthalein
T-2311-J BCG-MR Indicator
6117-G Barium Chloride
6102PS-H Alkalinity Titrant
7516-DR-02 5115PT-H Deionized Water
6073-G Barium Chloride
2246-E Phenolphthalein
6251DR-G Hydrochloric Acid
7519-01 7520-H Standard Turbidity
7530-DR-01 6130-E Hydrochloric Acid
6155-E Sodium Thiosulfate
6165-D Xylenol Orange
6158PS-H Thorium Nitrate
3929-E Fluoride Inhibitor
7530-WT-01 6130-E Hydrochloric Acid
6155-E Sodium Thiosulfate
6165-D Xylenol Orange
6158WT-H Thorium Nitrate
3929-E Fluoride Inhibitor
7625-01 6155-E Sodium Thiosulfate
6323-E Hydrochloric Acid
3964-E Chrome Azurol S
3965-H Thorium Nitrate
6130-E Hydrochloric Acid
82
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
Page 83
Reagent Refills
Kit Code Reagent # Description
7625-DR-01 6155-E Sodium Thiosulfate
6323-E Hydrochloric Acid
3965-H Thorium Nitrate
6130-E Hydrochloric Acid
3964-E Chrome Azurol S
7634-DC-01 6130-E Hydrochloric Acid
6155-E Sodium Thiosulfate
6158PS-H Thorium Nitrate
2202-G Meta Cresol Purple
6165-D Xylenol Orange
7634-DR-01 2202-G Meta Cresol Purple
6130-E Hydrochloric Acid
6155-E Sodium Thiosulfate
6165-D Xylenol Orange
6158PS-H Thorium Nitrate
7778-01 6456-H Sulfate Turb
7787-01 4450-G Iron 1
4451-S Iron 2
7791-DR-02 2786-E Total Alkalinity
6111DR-H Sulfuric Acid
6248DR-H Sodium Hydroxide
4483-E Hardness 5
4484-J Hardness 6
4487DR-H Hardness 7
7802 6251PS-H Hydrochloric Acid
6537-H Ammonium Hydroxide
6253-J Sodium Citrate
6254-H Dimethylglyoxime
6566-G Ammon. Persulfate
6346-G Silver Nitrate
5115PT-J Deionized Water
7824 7826-G Ammon. Hydroxide
7827-H Pot. Ferricyanide
7825-C Aminoantipyrine
7831-01 7833-E Tannin 1
7834-H Tannin 2
7884 7885-H Sulfuric Acid
7886-J Sodium Hydroxide
2246-E Phenolphthalein
6566-G Ammon. Persulfate
5115PT-J Deionized Water
7888-D Boiling Stones
7894-01 7939PS-G Hypochlorite A
7940-G Hypochlorite B
7941PS-H Hypochlorite C
8205 8215-H Acid Titration
2786-E Total Alkalinity
8225-01 8228-H TK-10 Rgt.
Kit Code Reagent # Description
8226-01 8230PA-H Chl. Cleaner 1
8233PA-H Chl. Cleaner 2
8234PA-H Chl. Cleaner 3
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
83
Page 84
Beakers - BOD

Apparatus

Beakers
Glass beakers have thick, slightly flared top, with spout designed for ex­cellent pouring. Designed from ASTM specifications E960, type I require­ments. All sizes have marking area and white graduated volume scale.
Thomas® Polypropylene Beakers are polypropylene with superior chemi­cal resistance. Ribbed for easy stacking. Meets ISO/DIS 7056 Standards for Lab Plastic Accuracy. Autoclavable.
Glass Order Code Plastic Order Code Description
0410 0944 Beaker, 50 mL
0415 0896 Beaker, 100 mL
0414 2-2011 Beaker, 150 mL
0596 Beaker, 200 mL
0411 0609 Beaker, 250 mL
2-2024 2-2013 Beaker, 400 mL
0412 2-2014 Beaker, 600 mL
2-2027 Beaker, 1,000 mL
BOD Polyseed
Polybac Corporation Polyseed
For producing acclimated seed for fast, economical BOD5 analyses with consistent results. Each capsule contains 100 mg for specialized, lyophilized bacterial cultures. Contents of capsule are added to 500 mL of APHA standard nutrient water at 20°C and stirred for 60 minutes. Resultant mixtureprovides enough acclimated seed for up to 250 BOD tests. EPA accepted.
Order Code Description
3-0002 Polyseed®, Pk 50
®
84
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
Page 85
Bod - Cleaners
Apparatus
Flask/BOD Bottle Brush
Allows access to entire inside surface of flasks or BOD bottles. Black hog bristle brush 4.25 inches. long mounted on a flat steel shank attached to a pivoting shaft.
Order Code Description
1929-R35 Brush, 16 inch, Pk 3
Imhoff Cone Brush
Conical shape with tufted bristle and sturdy twisted wire handle. Black bristles combine with stiff fibers, shaped to fit into cone tip. Bristle part 9 in. long, 4 in. top diameter, 1.5 inch bottom diameter, tip 3 inch long, length including handle 30 inch.
Burets
Twelve inch high, self-leveling, glass burets are graduated from 0–10 mL in 0.1 mL increments. Available with rubber squeeze valve, glass stopcock, or Teflon® stopcock. Buret-24 assembly includes empty 250 mL bottle of natural, low density polyeth­ylene which attaches to 24 mm screwcap on buret stem. Buret-28 assembly has 250 mL bottle of amber polyethylene and 28 mm cap. Bottle serves as titrant res­ervoir; a gentle squeeze forces titrant into buret, where it automatically levels on 0 mL mark at top of scale.
Order Code
Buret Type
Rubber Squeeze 0847-24 0847-28 0427
Glass Stopcock 0827-24 0827-28 0826
Teflon Stopcock 0996-24 0996-28 0997
With Poly
Bottle
Order Code
With Amber
Bottle
Order Code
Buret & Caps
Only
Order Code Description
1930-D10 Brush, Imhoff cone
Cleaners
Alconox® Biodegradable Cleaning Compound
Mild, odorless, non-toxic powdered wet­ting agent and detergent for cleaning glassware, porcelain, metal, plastic, or rubber. Suitable for use in ultrasonic cleaners. Usual dilution 1 tablespoon to 1 gallon water.
Order Code Description
2902-G05 Alconox, 4 lb Box
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
85
Page 86
Cleaners - Coliform
Apparatus
Cleaners (Continued)
Kimberly-Clark Kimwipe® Absorbent Light-Duty Wiper
Single-ply premium lab wiper for extra low-lint per­formance. Won’t scratch delicate surfaces. LINT­GUARD® polyshield reduces lint and electrostatic discharge when dispensing. Gently absorbent for light liquid pickup.
Order Code Description
2-2069 4.5 x 8.5 single-ply in dispensing box, Box 280
Coliform
Thomas® Coliform Water Sample Bag
Twist tie top seals with a 5 mm wide metal strip. Large textured label area. Meets EPA requirements for mi­crobiological samples for potable water according to Standard Methods (Meth­od 9060 A) or for NPDES compliance monitoring. Sterilized, with thiosul fate dechlorination tablet included. 100 mL fill line marked for easy reference.
Order Code Description
1303-R90 Sample Bag, 100/bag
-
COD Heater
120V and 230V, 12-tube capacity. This COD heater block features digital microprocessor control, programmable time and temperature settings, and a dual LED display to monitor both temperature and timer. Perfect for COD, Total Phosphorus, and Total Nitrogen testing PLUS other tests requiring digestion. See page 14 for additional specifications.
Order Code Description
5-0102 COD Heater Block, 120 V
5-0102-EX2 COD Heater Block, 230 V
Thomas® Coliform Water Sampling Vial
Improved sample container for microbiological testing. Ideal when filtra­tion or the Colilert® method is used. Improved latching mechanism, won’t open or leak in transit. Pre-sterilized, with thiosulfate tablet included. 120 mL fill line.
Order Code Description
9853-Q41 Vial with tablet, Bg 100
86
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
Page 87
Cylinders - Flasks
Apparatus
Cylinders
Glass cylinders have pouring spout and permanent fused white graduations. Plastic cylinders meet ASTM Class B, E1272 standards and have excellent heat and chemical resistance.
Plastic Volume (Ml)
2-2076 10 0.2 0416
2-2077 25 0.5 0417
2-2078 50 1.0 0418
2-2079 100 1.0 0419
2-2080 250 2.0
2-2081 500 5.0
2-2082 1,000 10.0
Graduation
Intervals (Ml)
Glass
Order Code
Filter Paper
All papers listed are sold 100 to a package.
Order Code Description
Alhstrom
0463 No. 642-27, Qual. 11 Slow
0465 No. 642, Qual. 9 Medium
Diameter
(Cm) Speed
Filter/Syringe Assembly
For on-site collection of filtrates or filtered material from natural or industrial waters. Consists of 60 mL plastic syringe, dual check-valve, Delrin® filter holder with Luer slip outlet and clear flexible PVC tubing, 3 ft. long x 0.625 inch i.d. Tubing attaches to check-valve outlet. Syringe is calibrated to 0 to 60 mL and 0 to 2 oz.
Order Code Description
1050 Complete filter/syringe
assembly
0943 Syringe, 60 mL
1175 Tubing, 36 in.
1174 Check-valve
0598 Filter Holder
Code 0598 holder acccepts the following filters (furnished in packages of 100, unless otherwise specified):
0947 Paper, 2.5 cm
1157 Glass Fiber, 24 mm
Membrane, 25 mm
1103 0.45 micron, pkg. 100
Whatman
0947 No. 2, Qual. 2.5 Medium
0471 No. 2, Qual. 9 Medium
2-2098 No. 42, Ashless, Quan. 9 Slow
2-2100 No. 42, Ashless, Quan. 12.5 Slow
1157 Glass Fiber 2.4
Whatman® Quantitative Ashless Filter Papers
Suitable for precipitates that are ordinarily difficult to filter (2.5 mm particle retension). Acid Wash, Ash Content 0.007%. Highly re­tentive for very fine analytical precipitates. Recommended for use with vacuum.
Order Code Description
2-2098 Filter Paper, 9 cm, Pk 100
4716-Q25 Filter Paper, 11 cm, Pk 100
2-2100 Filter Paper, 12.5 cm, Pk 100
Flasks
Nalge® Erlenmeyer Flasks
Glass flasks have thick-walled body with tapered contour to minimize chipping. Approxi­mate volumes are indicated. Plastic flasks are polycarbon­ate with polypropylene screw closures; use for preparation and storage of culture media and culturing techniques.
Plastic Order Code Description Glass Order Code
2-2116 Flask, 125 mL 0431
2-2117 Flask, 250 mL 0433
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
87
Page 88
Flasks - Hydrometers
Apparatus
Flasks, Corning Volumetric
Pyrex® Brand Class A. Heavy beaded, heavy tubing neck with snap cap. White block letters for easy readability.
Order Code Description
2-2127 Flask, Volumetric, 50 mL
2-2128 Flask, Volumetric, 100 mL
2-2129 Flask, Volumetric, 500 mL
Hydrometers
Specific Gravity 1 to 1.6
For liquids heavier than water. Approximate total length 305 mm, ap­proximate length of graduate scale 135 mm, viewing range has scale approximately 150 mm long, and is made without conventional enlarged bulb at bottom. Tolerance ±1 scale division. Requires a cylinder 340x38 mm and approximately 250 mL of liquid.
Order Code Description
2-2150 Hydrometer, 1.000-1.220: 0.002 interval
2-2151 Hydrometer, 1.200-1.420: 0.002 interval
2-2155 Hydrometer, 1.000-1.600: 0.005 interval
Corning Pyrex® Brand Hydrometer Cylinder
Heavy wall construction. Large, hexagonal base, sealed to the cylinder body, increases stability.
Order Code Description
2-2149 Hydrometer Cylinder,
38 x 340 mm
Funnels, Plastic
Reinforced rim. Ridges outside and inside permit air passage and im­prove filtering efficiency. Withstand continuous use at temperatures up to 130°C.
Order Code Description
2-2134 Funnel, 9 mL
2-2135 Funnel, 20 mL
0459 Funnel, 37 mL
2-2137 Funnel, 95 mL
88
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
Page 89
Pipets - Stirrers & Accessories
Apparatus
Magnifier
MacroLens
MacroLens with 5X mag­nification covers the entire petri dish. 4 inch diameter.
Order Code Description
5508 MacroLens
5508-10 MacroLens 10 Pack
Pipets: Corning Transfer Pipets
Pyrex® Class A. Tapered at both ends. Calibrated to deliver rated volume at 20°C.
Order Code Description
2-2170 Transfer Pipet, 1 mL
2-2174 Transfer Pipet, 5 mL
2-2175 Transfer Pipet, 10 mL
Pipets: Bel-Art® Safety Bulb
Tapered silicone seal provides airtight fit in all pipet sizes. 2-2164 comes complete with an elastic cord for dedicating pipettor to a specific re­agent bottle.
Order Code Description
2-2164 Safety Bulb
0395 Safety Bulb
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
Stirring Bars
Octagon-shaped with rounded ends and molded pivot ring.
Magnetic Stirring Bar Retriever
For insertion or removal of magnetic stirring bars. Overall length 11.5 inches.
Order Code Description
2-2185 Stirring Bar, .3125 x 1 inch
2-2186 Stirring Bar, .3125 x 1.625 inch
2-2187 Magnetic Pick Up Rod
89
Page 90
Stirrers & Accessories - Thermometers
Apparatus
Stopcock Grease
Lubriseal® Stopcock Grease
For lubricating ground glass joints, glass, and metal stopcocks and valves, and for sealing desiccators, anaerobic culture jars, and similar utensils. Prevents the freezing of stopcocks, ground joints, etc. Low vapor pressure, and resists attack by acidic and alkaline solutions. Smooth textured, stable, free from vegetable or animal oil or silicone, and practi­cally insoluble in water.
Order Code Description
2-2158-H Lubriseal, 75g tube
Thermometer, Armored
A precision, NON-MERCURY thermometer encased in a protective, plastic jacket. Window opening views engraved graduation on white tubing which increases readability. Full range of -5° to 45° in
0.5° increments.
Order Code Full Range
1066 -5° to 45°C in 0.5 ° increments
Thermometer, Thomas® Switchable, °C/°F
8 in. thermometer with a wide range and digital display. Fits into cuvettes, test tubes, flasks, and beakers. Stainless steel probe is resistant to acids, bases, solvents, and most laboratory chemicals. Dual range of -58° to 302°F or -50° to 150°C. Digi­tal resolution of 0.1° from -20° to 200°. Accuracy is ±1°C between -20° to 100°C. Readings updated every second. Operates continuously for over a year on a single re­placeable silver-oxide battery (included). Supplied with protective case that can be used as a holder.
90
Order Code Description
9329-H01 Switchable Thermometer with Digital Display
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
Page 91
Aquaculture Testing Products
Code 1612
Test kits and instrumentation for critical water quality control of aquarium systems. Designed for the hobbyist, retailer, and ornamen- tal fish culturist. Test kits, instrumentation, and combination outfits designed for fish farms, hatcheries, and research institutions. Equip- ment designed for monitoring water quality conditions on-site and at benchtop locations.
Science Education Products
Code 1590
Practical, “hands-on” test equipment for air, soil and water chemistry students in elementary, secondary, vocational, outdoor and college science programs.
Pool & Spa Water Test Equipment
Catalogs
Code 1634
A complete line of test kits, combination outfits and labs for pool pro- fessionals, public pool or spa operators, and private pool or spa owners.
Product Price List
Code 1645
This “component price list” gives price and ordering information on all standard LaMotte reagents, labware, apparatus and accessories. Reagents are listed in kit-size and bulk containers.
Soil Testing Products
Code 1652
Field and laboratory test equipment for measurement of soil nutrients and soil pH. For agricultural soils, greenhouses, gardens, dairy sanita- tion, aquaculture and hydroculture.
Water Conditioning Testing Products
Code 1650
Softener sales demonstration outfits and other specialized test equip- ment for the point-of-use water treatment industry.
Food & Beverage Safety Testing Products
Code 1658
A comprehensive collection of test kits, test strips, and instruments for use in Industrial and Food/Beverage applications.
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
91
Page 92
A Study of Water Quality
Dr. Charles E. Renn;
Handbooks
46 pages
Examines the “life cycle” of water from its occurrence in nature to its treatment for domestic and indus­trial use, with emphasis on such water quality problems as scaling, corrosiveness, taste, and turbidity.
Order Code 1532
A Laboratory Manual for Marine Science Studies
Staff, LaMotte Company; 32 pages
Test procedures and background information on sampling and anal­ysis in salt water environments ­oceans, bays, marine estuaries, and salt marshes.
Order Code 1587
Chemistry & Control of Modern Chlorination
Dr. A.T. Palin; 64 pages
The process of chlorination and principal methods of chlorine test­ing. Written by a leading interna­tional authority on chlorine mea­surement.
Order Code 1597
Investigating Water Problems
Dr. Charles E. Renn; 72 pages
Discusses 25 chemical factors of water quality analytical procedures for their measurement and inter­pretation of test results.
Order Code 1589
Limnology: An Introduction to the Fresh Water Environment
William A. Amos; 40 pages
Discusses biological, chemical, and physical processes in ponds, lakes, swamps, streams, and rivers
- stream dynamics, plant zonation, the succession of ponds, the energy cycle of ponds, etc.
Order Code 1593
Marine Aquarium Handbook
Staff, LaMotte Co.; 20 pages
Test procedures and background information on chemical testing for successful management of aquarium water.
Order Code 1585
Monitor’s Handbook
Staff, LaMotte Co.; 71 pages
A complete guide covering the im­portance of water quality of all types of natural waters. Gives guidance for watershed surveys, site location, sample collection, and choosing ap­propriate methods and equipment. Describes physical, chemical, and biological factors of water quality, and the analytical procedures for their measurement. Provides the basic program planning, data analy­sis, and reporting with conversion factors, glossary, and resource list. For individuals or groups starting a water quality monitoring program.
Order Code 1507
Our Environment Battles Water Pollution
Dr. Charles E. Renn; 32 pages
Traces a theoretical river from its origin as a mountain brook to its discharge into a marine estuary, ex­amining the chemical and biological changes that occur as the stream reacts to impurities from natural and industrial sources.
Order Code 1592
Pool Mgr. Handbook
Staff, LaMotte Company; 60 pages
A 60 page text for entry level life­guards or aquatic supervisors. Dis­cussions on water balance, sanita­tion, analysis, and problem solving. Water treatment charts are pro­vided.
Order Code 1505
A Study of Soil Science
Dr. Henry D. Foth; 44 pages
An introduction to soil formation, soil pH, mineral elements and plant nutrition, the life cycle of growing plants, and soil fertility manage­ment.
Order Code 1530
The LaMotte Soil Handbook
Staff, LaMotte Company; 60 pages
This “growers manual” discusses major and minor nutrients, trace elements, soil pH, organic matter, soil texture, etc. Includes lime and fertilizer recommendations for a variety of crops and plants.
Order Code 1504
Plant Nutrition Studies
Dr. Robert Stegner; 76 pages
Discusses the study and practice of hydroponics - plant culture in soilless solutions - and includes a series of laboratory investigations.
Order Code 1596
92
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
Page 93
LaMotte has available a large variety of standards to be used in many applications.

Standards

Primary Standards Concentration
Ammonia Nitrogen
Chlorine 250 ppm 6973-H 60 6 mo.
Chlorine 250 ppm 6973-L 475 6 mo.
Chlorine Equivalent
COD Equivalent
Color 500 cu 6058-H 60 3 yrs.
Color 500 cu 6058-L 500 3 yrs.
Conductivity/ TDS
Conductivity/ TDS
Conductivity/ TDS
Conductivity/ TDS
Conductivity/ TDS
Conductivity/ TDS
Conductivity/ TDS
Conductivity/ TDS
Conductivity/ TDS
Conductivity/ TDS
Conductivity/ TDS
Conductivity/ TDS
Conductivity/ TDS
Copper 100 ppm 6181-L 475 2 yrs.
Fluoride 1000 ppm 4154-H 60 1 yr.
Fluoride 1000 ppm 4154-L 500 1 yr.
Fluoride 1 ppm 2798-M 1000 2 yrs.
Hard Water 120 ppm 5617-L 500 3 yrs.
Ferric Iron 200 ppm 3860-H 60 1.5 yrs.
Magnesium 1000 ppm 6190-H 60 1 yr.
Nickel 1000 ppm 6196-H 60 2 yrs.
Nitrate Nitrogen
pH 2.0 2856-L 500 1.5 yrs.
100 ppm 3871-H 60 2 yrs.
1000 ppm 3858-H 60 6 mo.
500 ppm 7589-L 475 2 yrs.
84 µS/59 ppm 6312-L 500 1.5 yrs.
718 µS/ 503 ppm
718 µS/ 503 ppm
718 µS/ 503 ppm
1413 µS/ 989 ppm
1413 µS/ 989 ppm
1413 µS/ 989 ppm
6668 µS/ 4668 ppm
6668 µS/ 4668 ppm
12880 µS/ 9016 ppm
12880 µS/ 9016 ppm
12880 µS/ 9016 ppm
58640 µS/ 41048 ppm
1000 ppm 5392-H 60 2 yrs.
Order Code
6417-J 120 1.5 yrs.
6417-L 500 1.5 yrs.
6417-N 3800 1.5 yrs.
6354-J 120 1.5 yrs.
6354-L 500 1.5 yrs.
6354-N 3800 1.5 yrs.
6418-J 100 1.5 yrs.
6418-L 500 1.5 yrs.
6317-G 30 1.5 yrs.
6317-J 120 1.5 yrs.
6317-L 500 1.5 yrs.
6419-L 500 1.5 yrs.
Quantity (mL) Shelf Life
Primary Standards Concentration
pH Buffer Tablets
pH Buffer Tablets
pH 4.01 2866-J 120 1.5 yrs.
pH 4.01 2866-L 500 1.5 yrs.
pH 4.01 2866-N 3800 1.5 yrs.
pH Color Coded Red
pH 6.0 2876-L 500 1.5 yrs.
pH 6.86 2808-L 500 1.5 yrs.
pH Buffer Tablets
pH Buffer Tablets
pH 7.00 2881-H 60 1.5 yrs.
pH 7.00 2881-J 120 1.5 yrs.
pH 7.00 2881-L 500 1.5 yrs.
pH 7.00 2881-N 3800 1.5 yrs.
pH Color Coded Yellow
pH 8.0 2886-L 500 1.5 yrs.
pH 9.0 2891-L 500 1.5 yrs.
pH 9.18 2809-L 500 1.5 yrs.
pH Buffer Tablets
pH Buffer Tablets
pH 10.0 2896-J 120 1.5 yrs.
pH 10.0 2896-L 500 1.5 yrs.
pH Color Coded Blue
pH 11.0 2897-L 500 1.5 yrs.
pH 12.0 2898-L 500 1.5 yrs.
Phosphate PO
4
Phosphate PO
4
Phosphate PO
4
Phosphorus (Total)
Phosphorus (Total)
Potassium 1000 ppm 6187-L 475 2 yrs.
Sulfate 2000 ppm 7120-H 60 2 yrs.
4.0 3983A-H 50 Tabs 3 yrs.
4.0 3983A-J 100 Tabs 3 yrs.
4.01 3771-L 500 1.5 yrs.
7.0 3984A-H 50 Tabs 3 yrs.
7.0 3984A-J 100 Tabs 3 yrs.
7.00 3772-L 500 1.5 yrs.
10.0 3985A-H 50 Tabs 3 yrs.
10.0 3985A-J 100 Tabs 3 yrs.
10.0 3773-L 500 1.5 yrs.
1000 ppm 6184-L 475 1 yr.
3080 ppm 5393-H 60 2 yrs.
3080 ppm 5393-L 475 2 yrs.
1000 ppm 5393-H 60 2 yrs.
1000 ppm 5393-L 475 2 yrs.
Order Code
Quantity (mL) Shelf Life
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
continued next page...
93
Page 94
Standards
Primary Standards Concentration
Turbidity 2020we
Turbidity 2020we
Turbidity 2020we
Turbidity 2020we
Turbidity 2020wi
Turbidity 2020wi
Turbidity 2020wi
Turbidity 2020wi
Turbidity 2020e
Turbidity 2020e
Turbidity 2020e
Turbidity 2020e
Turbidity 2020i
Turbidity 2020i
Turbidity 2020i
Turbidity 2020i
Turbidity 2020
Turbidity 2020
Turbidity 2020
Turbidity Formazin
Zinc 100 ppm 5394-L 475 2 yrs.
0 NTU 1480 60 1 yr.
1 NTU 1450 60 1 yr.
10 NTU 1451 60 1 yr.
100 NTU 1452 60 1 yr.
0 NTU 1480 60 1 yr.
1 NTU 1453 60 1 yr.
10 NTU 1454 60 1 yr.
100 NTU 1455 60 1 yr.
0 NTU 1480 60 1 yr.
1 NTU 1484 60 1 yr.
10 NTU 1485 60 1 yr.
100 NTU 1486 60 1 yr.
0 NTU 1480 60 1 yr.
1 NTU 1481 60 1 yr.
10 NTU 1482 60 1 yr.
100 NTU 1483 60 1 yr.
1 NTU 1476 60 1 yr.
10 NTU 1477 60 1 yr.
100 NTU 1478 60 1 yr.
4000 NTU 6195-H 60 1 yr.
Order Code
Quantity (mL) Shelf Life
Secondary Standards
Chlorine DPD 0, 0.2, 1.0,
Smartcheck Various
Concentration Order
2.5 ppm
Absorbance Units
Code
4140-02
4141-01
94
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
Page 95

Index

A
Absorbance Colorimeters ..............21
Acidity
Individual Test Kits .................39, 61
Adapters,- AC
AC Power: 1200 Series ................19
AC Power: Battery Pack for
SMART Spectro .....................14
AC Power: pHPLUS Direct .............30
Adapter, Vial
COD vial adapter ....................... 9
UDV vial adapter ....................... 9
Alkalinity
Buret Reagents .......................66
Individual Test Kits .................... 39
Test Strips ............................34
TesTabs ..............................71
UDV SMART Reagent ..................17
Aluminum
Individual Test Kits .................... 39
SMART Reagent System ..............17
AMCO Turbidity Standards ......... 11, 13
Ammonia
ISE ...................................30
ISE Accessory Kit .....................30
Ammonia Nitrogen
Colorimeter Kit, 1200 ..............19, 40
Individual Test Kits .................... 40
SMART Reagent System ...........17, 18
Apparatus
Alphabetical Listing ............... 84-90
Aquaculture & Aquarium
Testing Products Catalog ............ 91
Aquaculture Combination Outfits
Fresh Water ..........................56
Salt Water ............................56
Arsenic ................................40
Automatic Buret Reagents .............66
B
BART Biodetectors .....................38
Battery Pack for SMART Spectro ....... 14
Beakers ...............................84
Benzotriazole
SMART Reagent System ...........17, 18
Biopaddles ........................36-37
Biochemical Oxygen Demand (BOD)
Brush ................................85
PolySeed .............................84
Bleach
Individual Test Kits .................43, 62
Boron
SMART Reagent System ...........17, 18
Bromine
Colorimeter Kit, 1200 ..............19, 40
Individual Test Kits .................... 40
SMART Reagent System ...........17, 18
Brushes
General ...............................85
Flask/BOD ............................85
Imhoff Cone ..........................85
Buffers
pH, Standardized .....................32
Color Coded Solutions ................32
Tablets ...............................32
Buret Combination Kits ................65
Buret Reagents ........................66
Burets .................................85
C
Cadmium
Individual Test Kit .....................41
SMART Reagent System ...........17 ,18
Calcium Hardness
See Hardness
Carbon Dioxide
Individual Test Kits .................... 41
Carbohydrazide
SMART Reagent System ...........17, 18
Cases
SMART Spectro .......................14
Catalogs, Market Specific ..............91
Caustic
Individual Test Kits .................41, 61
Chelant
Individual Test Kits .................... 41
Chemistry and Control of Modern
Chlorination Handbook ...............
Chloride
Buret Reagents .......................66
Individual Test Kits .................... 41
SMART Reagent System ...........17, 18
Chlorine
Colorimeter Kit, Liquid, 1200 .......20, 42
Colorimeter Kit, Tablet, 1200 .......20, 42
Individual Test Kits .................42, 61
Secondary Standards Kit ..............21
Primary Standards ....................21
Reagents ..........................17, 72
SMART Reagent System ...........17, 18
Tracer ................................22
92
Test Papers. . . . . . . . . . . . . . . . . . . . . . . .43, 61
Test Strips .........................34, 61
TesTabs for Tracer ....................22
Tri-Meters .........................12, 13
Chlorine Dioxide
Colorimeter Kit, 1200 ..............19, 20
Individual Test Kits .................... 44
SMART Reagent System ...........17, 18
Test Strips ............................34
Chromate
Individual Test Kit .....................44
Chromium
Individual Test Kit .....................44
SMART Reagent System ...........17, 18
Cleaners
Alconox® .............................85
Kimwipes® ...........................86
Cobalt
SMART Reagent Systems ..........17, 18
COD
Adapter for SMART Colorimeter ......... 9
Heater Blocks .....................15, 86
SMART Reagent System ...........17, 18
Reagents .............................16
Coliform
Filter Flasks ..........................88
Filter Paper ...........................87
Individual Test Kit .....................38
Sample Bags .........................86
Sample Vials .........................86
Color
Individual Test Kit .....................44
SMART Reagent System ...........17, 18
LTC-3000 .........................12, 13
Tri-Meters .........................12, 13
ColorQ Colorimeter ....................71
ColorQ Pro-9 ..........................71
Colorimeter
Single Test ........................19, 20
Single Test Accessories ............19, 20
Single Wavelength Absorbance ........21
SMART3 Colorimeter .................8, 9
UDV ..................................21
Colorimeter Series, DC1200 ........19, 20
Colorimetric Test Method .............6
Combination Buret Outfits .............65
Conductivity
5 and 6 Series Meters .................29
PockeTesters ......................23, 26
Standards .........................23, 33
Neutralizing Solutions ................33
Tracer Meter ..........................23
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
95
Page 96
Index
Copper
Colorimeter Kit, DC1200 ...........20, 45
Individual Test Kits .................... 45
SMART Reagent System ...........17, 18
Test Strips ........................34-35
Corrosion Control Kit ...................74
Custom Test Kit Services ................ 5
Cyanide
Individual Test Kit .....................45
SMART Reagent System ...........17, 18
Cyanuric Acid
SMART Reagent System ...........17, 18
Tablets ...............................72
Cylinders ..............................87
D
DC1200
Colorimeter Series .................19, 20
DEHA
Individual Test Kits .................... 45
SMART Reagent System ...........17, 18
DO Meter ..............................24
Detergents
Individual Test Kits .................... 45
DipCell Series ..........................70
Direct Reading Titrator
Combination Outfits .............. 67-68
Test Methods .......................... 7
Dissolved Oxygen
See Oxygen
Duo-Soft ..............................75
DPD Reagents
Liquids ............................20, 72
Powder-Pop Dispensers ..............20
TesTabs ...........................20, 72
Dropper Bottle ............................
Combination Outfits .............. 67-68
Test Methods .......................... 7
Dropper Pipet
Test Methods .......................... 7
E
Electrode Soaker Bottle ................32
Electrodes for PockeTesters. . . . . . . . 22-27
Environmental Science
Education Catalog ....................91
Environmental Science Education
Combination Outfits .............. 57-60
Erythorbic Acid
SMART Reagent System ...........17, 18
F
Filter Papers
General Lab ..........................87
Filter/Syringe Assembly ................87
5 and 6 Series Meters ..................29
Flasks
Brush ................................85
Erlenmeyer ...........................87
Filter Flasks ..........................88
Volumetric ...........................88
Fluoride
Colorimeter Kit, DC1200 ...........20, 45
ISE ...................................30
ISE Accessory Kit .....................30
SMART Reagent System ...........17, 18
Food Sanitizer Kits .....................61
Formaldehyde
Individual Test Kit .....................45
Fresh Water Aquaculture
Combination Outfits .................56
Funnels, Plastic ........................88
G
General Water Analysis
Combination Outfit .............. 63-64
Graduated Cylinders ...................87
GREEN
Low-Cost Water Monitoring Kit ........60
H
Handbooks ............................ 92
Hardness
Buret Reagents .......................66
Calcium Hardness TesTabs ............ 72
Individual Test Kits .................... 46
Test Strips ........................34-35
Hydrazine
Individual Test Kit .....................46
SMART Reagent System ...........17, 18
Hydrogen Peroxide
Individual Test Kits .................47, 50
SMART Reagent System ...........17, 18
Test Strips ............................34
Hydrometers
Cylinder ..............................88
Specific Gravity .......................88
Hydroquinone
SMART Reagent System ...........17, 18
I
International Sales ...................... 5
Iodine
Individual Test Kits .................... 47
SMART Reagent System ...........17, 18
Test Papers. . . . . . . . . . . . . . . . . . . . . . . . 47, 61
Ion Specific Electrode
Accessory Kits ........................30
pH Plus Direct Meter ..................30
Probes ...............................30
Tracer Meter ..........................22
Individual Test Kits
By Test Factor .................... 39-55
Industrial Titration Reagents ...........66
Industrial Water
Combination Outfits .............. 65-68
Insta-Test® Strips ..............34, 35, 69
Instrumentation .....................8-33
Investigating Water Problems
Handbook ............................
Iron
Colorimeter Kit, DC1200 ..............20
Individual Test Kits .................... 47
SMART Reagent System ...........17 ,18
92
K
Kick-Net ...............................58
Kimwipes® ............................86
L
A Laboratory Manual for Marine
Science Studies Handbook ...........92
The LaMotte Soil Handbook ............92
Laundry Combination Outfits ..........62
Laundry Spot Tests ....................62
Lead
SMART Reagent System ...........17, 18
Lead in Solder
Individual Test Kit .....................47
Leaf Pack Stream Ecology Kit ..........57
Limnology: An Introduction to the
Fresh Water Environment Handbook ..
Limnology Combination Outfit .........58
Lignin
Individual Test Kit .....................55
LTC-3000we/wi .................... 12, 13
Lubriseal® .............................90
92
96
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
Page 97
Index
M
Manganese
Colorimeter Kit, DC1200 ...........19, 20
Individual Test Kits .................... 48
SMART Reagent System ...........17, 18
Magnetic Stirrers ......................89
Accessories ..........................90
Marine Aquarium Handbook. . . . . . . . . . . .
Marine Science Outfit ..................58
Mercury
SMART Reagent System ...........17, 18
Methods, Test .........................6-7
Methylene Bisthiocyanate ..............48
Methylethylketoxime
SMART Reagent System ...........17, 18
Microbiological Tests .............. 36-38
Min/Max Thermometer ................25
Molybdate/Molybdenum
Individual Test Kits .................... 48
Colorimeter Kit, DC1200 ...........19, 48
SMART Reagent System ...........17, 18
Monitor’s Handbook ................... 92
MPS-OUT TesTabs .....................72
92
N
Nickel
Individual Test Kit .....................48
SMART Reagent System ...........17, 18
Nitrate Nitrogen
Colorimeter Kit, DC1200 ...........19, 49
Individual Test Kits .................... 49
ISE ...................................30
ISE Accessory Kit .....................30
SMART Reagent System ...........17, 18
Test Strips ............................35
Nitrite Nitrogen
Individual Test Kits .................... 49
SMART Reagent System ...........17, 18
Test Strips ............................35
Nitrite, Sodium
Individual Test Kits .................... 49
Nitrogen, Total Digestion Tubes .....15, 18
O
ORP PockeTester ......................25
ORP Tracer ............................22
Our Environment Battles Water
Pollution Handbook ..................
Oxygen, Dissolved
Individual Test Kit .....................50
92
SMART Reagent System ...........17, 18
Tracer Meter ..........................24
Oxygen Scavenger
SMART Reagent Systems ..........17, 18
Ozone
Individual Test Kit .....................50
SMART Reagent System ...........17, 18
Colorimeter Kit, DC1200 ...........19, 50
P
Peracetic Acid
Individual Test Kit .....................50
Test Strips .........................34, 50
Peroxide
See Hydrogen Peroxide
pH
5 Series pH Meter .....................29
Buffers ...............................32
Electrodes for pHPLUS Meter .........30
Individual Test Kits .................... 51
Electrode Soaker Bottle ...............32
Meters .................22, 23, 25, 29, 30
pHPLUS Direct Meter .................30
PockeTesters ..................22, 23, 25
SMART Reagent System ...........17, 18
Tablets ...............................72
Test Papers. . . . . . . . . . . . . . . . . . . . . . . .50, 61
Test Strips .....................34, 35, 69
Tracer ................................22
pH/Conductivity
Tracer Meter ..........................23
pH, Buffers & Acid/Base Titrations
Handbook ............................
Phenols
Individual Test Kit .....................50
SMART Reagent System ...........17, 18
Phosphate
Colorimeter Kit, DC1200 ...........19, 52
Individual Test Kits .................... 52
SMART Reagent System ...........17, 18
Phosphonate
Individual Test Kits ................ 52-53
Phosphorus, Digestion Tubes .......15, 18
Pipets
Safety Bulb ...........................89
Transfer ..............................89
Plankton Net ..........................58
Plant Nutrition Studies Handbook ......
PockeTesters ......................22-27
Electrodes ........................ 22-27
Polyphosphates
Individual Test Kit .....................53
92
92
Polyquat
Individual Test Kit .....................53
Pool & Spa Combination Outfits .... 69-71
Pool & Spa Testing
Equipment Catalog ...................91
Pool MGR. Handbook ...................
Pool MGR. Series Kits ..................69
Potassium
Individual Test Kit .....................53
SMART Reagent System ...........17, 18
Powder Pop DPD Dispensers
For Free & Total Chlorine .............. 20
PRO250 Kit ............................70
Product Price List ......................91
92
Q
QAC
Individual Test Kits .................... 53
Test Papers. . . . . . . . . . . . . . . . . . . . . . . .53, 61
R
Reagent Refills .................... 76-83
RS-232 Cable. . . . . . . . . . . . . . . . . . . . . . . . . . 19
S
Safety Bulb
Pipet .................................89
Salinity
Individual Test Kit .....................53
Salt Water Aquaculture
Combination Outfit ..................56
Salt Water PockeTesters ........... 23, 26
Salt Water Test Strips .............. 34, 69
Sample Bags
Coliform ..............................86
Secchi Disk ............................58
Silica
Individual Test Kits .................... 54
SMART Reagent System ...........17, 18
Single Test Colorimeters ........... 19, 20
SMART3 Colorimeter
Accessories ........................... 9
Meter ...............................8, 9
SMART Reagent Systems ..........17, 18
Water Analysis Lab ................ 63-64
SMART Spectro Spectrophotometer
Accessories ..........................14
Instrument ...........................14
Reagent Systems ..................17, 18
SMARTLink 3 Software and cable ....... 9
®
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
97
Page 98
Index
Sodium Chloride
Test Strips .........................34, 69
PockeTesters ..................... 23-27
Sodium Nitrite
See Nitrite
Softeners ..............................75
Softener Sales Demo Kits ..............75
Soil Testing Products Catalog .......... 91
Spa/Pool Combination Outfits ..... 67-71
Standards
Full Listing ........................93, 94
Chlorine ..............................21
Turbidity ...........................11, 13
TDS/Conductivity ..................23, 33
Stir Bars ...............................90
Retrievers ............................90
Stirrers
Accessories ..........................90
Stopcock Grease
Lubriseal® ............................90
StormWatch Kit .......................73
A Study of Soil Science
Handbook ............................
A Study of Water Quality
Handbook ............................
Sulfate
Colorimeter Kit, DC1200 ..............19
Individual Test Kits .................... 54
Sulfate Interference Suppresor Kit .....52
Sulfate
Individual Test Kits .................... 54
SMART Reagent System ...........17, 18
Sulfide
Individual Test Kits .................... 54
SMART Reagent System ...........17, 18
Sulfite
Buret Reagents .......................66
Individual Test Kits .................... 55
Surfactants
SMART Reagent System ...........17, 18
92
92
T
Tannin
Individual Test Kit .....................55
SMART Reagent System ...........17, 18
Temperature
Min/Max PockeTester .................25
Probe, pHPLUS Direct .................30
Temptestr IR ......................... 28
Test Methods .........................6-7
Test Papers
pH, Chlorine, Iodine, QAC ..............61
Test Strips
Alkalinity .............................34
Chlorine .............................34
Hardness .............................34
Insta-Test Pool/Spa Series ............69
pH ...................................34
Hydrogen Peroxide. . . . . . . . . . . . . . . . . . . . 34
Multi-factor .......................35, 69
Single Factor .........................34
Sodium Chloride ...................34, 69
TesTabs ............................ 20, 72
Thermometers
Armoured Thermometer ..............90
Dual Scale ............................90
Min/Max PockeTester .................25
Switchable ...........................90
Temptestr IR .........................28
Titrimetric Methods ..................... 7
Tolcide PS .............................55
Tolyltriazole
SMART Reagent System ...........17, 18
Total Dissolved Solids (TDS)
6 Series Meters .......................29
PockeTesters ......................22, 27
Standards .........................23, 33
Tracer Meter ..........................23
Tour Series
Pondwater Tour ....................... 59
Shore Tour ...........................59
Tapwater Tour ........................59
Topsoil Tour ..........................59
Watershed Tour .......................59
Tracer Meter Series ................ 22-24
Accessories ...................... 22-24
Chlorine, pH, ORP .....................22
Dissolved Oxygen .....................24
pH/Conductivity ......................23
TDS/Salt .............................23
Transfer Pipets ........................ 89
Turbidity
Turbidity Accessories ..............11, 13
Turbidity Standards ................11, 13
Turbidity Meters
2020we ...........................10, 11
2020wi ............................10, 11
LTC-3000we/wi ....................12, 13
Turbidity: Its Meaning &
Measurement Handbook .............
92
U
UDV
Adapters .............................. 9
Colorimeters .........................21
UV-VIS Spectrophotometer ............ 16
V
Vials
Sampling, Coliform ...................86
W
Wastewater Lab ....................... 72
Water & Wastewater
Combination Outfits ..................73
Water Conditioning
Combination Outfits .............. 74-75
Water Conditioning
Testing Equipment Catalog ........... 91
Water Quality Educator
Monitoring Outfit .....................57
Water Quality Combination Outfits .....75
WaterLink® Spin .......................67
Weighted Stand for Tracer .............22
Wide Range pH .................34, 35, 50
Z
Zinc
Individual Test Kits .................... 55
SMART Reagent System ...........17, 18
98
LaMOTTE COMPANY 800.344.3100 | 410.778.3100 www.lamotte.com
Page 99
How To Order

Order Form

By Mail: LaMotte Company PO Box 329 Chestertown, Maryland 21620 USA
Bill To
Name
Title
Company
Department
City
State/Zip
Phone
Account #
Special Instructions:
By Phone: 800 344 3100 410 778 3100
By Fax: 410 778 6394
Website: www.lamotte.com
Ship To
Name
Title
Company
Department
City
State/Zip
Phone
Ship Via.
Payment Method
Payment Terms are net 30 days to accounts with established credit. New accounts should provide credit references or en­close payment with order. MasterCard, VISA, and American Express are also accepted.
 Check  Purchase Order  MasterCard  VISA  American Express
Credit Card Account #
Expiration Date
Purchase Order #
Name as it appears on card
Order
Please include the product code number for each item ordered to insure that your order is speedily and correctly processed. Prices are f.o.b., Chestertown, Maryland. Prices are subject to change without prior notice. A $7.50 handling fee and a $7.50 shipping fee are applied to all orders totaling less than $35.00. On orders to which a handling fee is not applicable, freight charges will be added at cost to invoice total.
Quantity Code Model/Description Unit Price Extension
Net Total
$15.00 Shipping and Handling Fee (If Net Total is Less Than $35.00)
Sales Tax, If Applicable (Maryland Only)
Invoice Total
Page 100
PHONE 1-800-344-3100
(001) 1-410-778-3100
FAX (001) 1-410-778-6394
INTERNET www.lamotte.com
lamotte.com/contact_us.html
MAIL PO Box 329
802 Washington Avenue Chestertown, Maryland 21620 USA
EASY PAYMENT Order with a purchase order or use VISA,
American Express, MasterCard or enclose payment with purchase order if you don’t have an account. To open a new account, please provide credit references.
COURTEOUS SERVICE and an interest in every customer’s
satisfaction have given LaMotte Company a reputation of
distinction in the chemical testing field. Please give us the
opportunity to meet your chemical testing requirements today.
Loading...