DPD CHLO RINE & pH TEST KIT
MODEL LP-3 • CODE 6907
For Free Available Chlorine, Combined Chlorine, Total Residual
Chlorine & pH (Phenol Red).
QUANTITY CONTENTS CODE
50 *Chlorine DPD #1R Tablets (6999) *6905A-6999ABOX
50 *Chlorine DPD #3R Tablets (6905)
50 Phenol Red Tablets 6915A-H
4 Test Tubes, 5 & 10 mL, glass, w/caps 0898
1 Phenol Red Comparator, 6.8-8.2 2185
1 Chlorine DPD Comparator, 0.2-3.0 ppm 6902
*WARNING: Reagents marked with an * are considered to be potential health
hazards. To view or print a Material Safety Data Sheet (MSDS) for these reagents
go to www.lamotte.com. To obtain a printed copy, contact LaMotte by e-mail,
phone or fax.
To order individual reagents or test kit components, use the specified code
number.
USE OF THE OCTET COM PARA TOR
The Octet Comparator contains eight permanent
color standards. A test sample is inserted into the
openings in the top of the comparator. The
sample can then be compared to four color
standards at once, and the value read off the
comparator. For optimum color comparison, the
comparator should be positioned between the
operator and a light source, so that the light
enters through the special light-diffusing screen
in the back of the comparator. Avoid viewing the
comparator against direct sunlight or an
irregularly lighted background.
PRO CE DURE
FREE AVAIL ABLE CHLO RINE (FAC)
Recommended minimum Free Available Chlorine level in pool water is
1.0 ppm in unstabilized pools; 2.0 ppm in stabilized pools. For bather
safety after superchlorination, the maximum level of Free Chlorine is 3.0
ppm.
1. Rinse a test tube (0898) with sample water. Fill to 5 mL line with
sample water.
2. Add one *Chlorine DPD #1R Tablet (6999A). Cap and mix until
tablet disintegrates.
3. Immediately insert test tube into Chlorine DPD Comparator (6902).
Match sample color to a color standard. Record as ppm Free
Available Chlorine.
NOTE: Do not discard this test sample if total residual chlorine is to
be determined.
TO TAL RE SID UAL CHLO RINE (TRC)
Ideally, the Total Residual Chlorine should be equal to the Free Available
Chlorine reading. Combined Chlorine should not exceed 0.2 ppm.
4. Add one *Chlorine DPD #3R Tablet (6905A) to sample from Step 3.
Cap and mix until tablet disintegrates.
5. Insert test tube into Chlorine DPD Comparator (6902). Match
sample color to a color standard. Record as ppm Total Residual
Chlorine.
Combined Chlorine ppm =
Total Residual Chlorine _ Free Available Chlorine
pH - PHE NOL RED IN DI CA TOR
Rec om mended op ti mum pH range for pool wa ter is pH 7.2 to pH 7.6.
1. Rinse a test tube (0898) with sample water. Fill to 10 mL line with
sample water.
2. Add one Phenol Red Tablet (6915A). Cap and gently mix until
tablet disintegrates.
3. Immediately insert test tube into the Phenol Red Comparator (2185).
Match sample color to a color standard. Record as pH units.
LaMOTTE COM PANY
Helping Peo ple Solve An a lyt i cal Challenges
PO Box 329 • Chestertown • Mary land • 21620 • USA
800-344-3100 • 410-778-3100 (Out side U.S.A.) • Fax 410-778-6394
Visit us on the web at www.lamotte.com