LaMotte BL-5 User Manual

BL-5 TEST KIT FOR CASI 773
CODE 6680
QUANTITY CONTENTS CODE
15 mL Sodium Thiosulfate, 0.1N 6155-E 10 g Xylenol Orange Powder 6165-D 15 mL *Hydrochloric Acid, 0.5N *6025-E 60 mL *Thorium Nitrate *6158PS-
H
glass, w/cap 1 Spoon, 0.1 g 0699 1 Pipet, plain, glass, w/cap 0344
*WARNING: Reagents marked with an * are considered hazardous substances. To view or print a Material Safety Data Sheet (MSDS) for these reagents see MSDS CD or our web site. To obtain a printed copy, contact us by e-mail, phone or fax.
To order individual reagents or test kit components, use the specified code number.
0608
PRO CE DURE
1. Fill a test tube (0608) to the 25 mL line with sample water.
2. Add 2 drops of Sodium Thiosulfate, 0.1N (6155).
3. Use the 0.1 g spoon (0699) to add 0.3 g (3 measures) of Xylenol
Orange Powder (6165). Cap and mix until powder dissolves. Solution color will range from purple to yellow.
4. If solution is yellow, add 1 drop of *Hydrochloric Acid, 0.5N (6025)
and proceed to Step 5. If solution is purple, add *Hydrochloric Acid,
0.5N (6025), one drop at a time, gently swirling after each drop, until solution turns yellow. Add one more drop of *Hydrochloric Acid,
0.5N (6025).
5. Use the pipet (0344) to add *Thorium Nitrate (6158PS), one drop at
a time, until solution changes from yellow to bright pink. Swirl after each drop and count the number of drops added. This is Value A.
6. Repeat Steps 1 through 5 on makeup water. Count the number of
drops added. This is Value B.
CASI 773 Concentration, ppm = 1.2 (Value A - Value B)
LaMOTTE COM PANY
Helping People Solve Analytical Challenges
PO Box 329 • Chestertown • Mary land • 21620 • USA
800-344-3100 • 410-778-3100 (Out side U.S.A.) • Fax 410-778-6394
Visit us on the web at www.lamotte.com
®