Read "Jump Start" before beginning!
Insert Chlorine
>0.2
2
1
Octa-Slide 2 Bar
(3401-01/3428-01
/3430-01) into
the Oc ta-Slide 2
Viewer (1 101).
1
Insert Chlorine
Octa-Slide 2 Bar
(3401-01/3428-01
/3430-01) into
the Oc ta-Slide 2
Viewer (1 101).
Multiply re sults abov e by 2.5,
1
Insert pH
Octa-Slide 2 Bar
(3403-01) into
the Oc ta-Slide 2
Viewer (1 101).
Add one
1
1
Alk Test
Tab let
(3920A)
to a test
tube
(0969).
Add one
*Calcium
Hardness
Tab let
(6846A)
to a test
tube
(0969).
2
2
Free Chlorine
Cl
2
Ideal Range:
1.0 - 3. 0 ppm
Total Chlorine
Cl
Ideal Range:
Equal to Free Cl2 or
Combined Cl
2
Bromine
pH
Ideal Range:
7.2 - 7.8 pH
Total Alkalinity
Alk
Ideal Range:
100-150 ppm
Ca Hardness
Hard
Ideal Range:
200 - 40 0 ppm
*Pot ential H ealth Ha zard: Re ad produc t label be fore use . See lamo tte.co m for SDS.
Emergency information for all LaMotte reagents is available from Chem-Tel
(US, 1-800-255-3924) (International, call collect, 813-248-0585).
Fill tube
2
(0106)
to 5 mL
line with
sample
water.
2
Remove
cap from
the Free
Chlorine
reaction.
2
Fill tube (0106)
to 10 mL line.
NOTE: If Chlorine is >8.0 ppm,
add 1 drop of Chlorine
neutralizer (Sodium
Thiosulfate)
to the pH test
sample before adding the
tablet.
Use the sample
bottle (0688)
to add sample
water
to the
400 ppm line.
Use the sample
bottle (0688)
to add sample
water to the
400ppm line.
Add one
3
DPD #1R Table t
(6999A) to tube.
Cap and mix
until tablet
disintegrates.
3
Add one
DPD #3R Table t
(690 5A) to tube.
Cap and mix
until tablet
disintegrates.
Gently
3
swirl to
disintegrate
the tablet.
Gently
3
swirl to
disintegrate
the tablet.
3
Add one
Phenol Red
Table t (69 15A)
to tube. Cap an d
mix until tab let
disintegrates.
4
4
If a gre en color
4
is present
alkalinity
is abov e 400
ppm. If c olor
is red, go
to Step 5.
If a pink c olor
4
is present
hardness is
above 400
ppm. If c olor
is purp le, go
to Step 5.
Insert
tube into
OctaSlide 2
Viewer.
Insert
tube into
OctaSlide 2
Viewer.
test
test
4
Code 3368-01/Code 3368-NJ-01/
Matc h sample to a color
5
standard. Record as ppm
Free C hlorine. Do
not discard sample
if Total Chlorine
is to be tested.
5
Matc h sample to a color
standard. Record as ppm
Free Chlorine. Total Chlorine.
5
Match sample
test
Insert
tube into
OctaSlide 2
Viewer.
5
5
to a color
standard.
Record
as pH.
Add small amounts
of sample water
until r ed color
changes to green.
Swirl tube between
each addition! Read
result at liquid
leve l on tube.
Add small amounts
of sample water
until p urple color
changes to pink.
Swirl tube between
each addition! Read
result at liquid level
on tube.
3368-ABC-01
Cyanuric Acid
CyA
Ideal Range:
30 - 100 ppm
Remove square
1
tube and c ap
from double
tube (1161).
Fill round tube to
top line w ith sample.
Add one
2
*Cyanuric Acid
Table t (69 94A) ,
cap wi th solid
cap and mi x until
tablet disintegrates
Replace solid cap
3
with the calibrated
square tube and
cap collar. The
square tube will
fill with turbid
liquid.
Viewing from
4
above, adjust
the square tube
until the black
dot just barely
disappears.
Read result on
tube at the
water level.
To rea d abo ve
NOTE
100 ppm, retest
by adding sample t o
lower line, add t ap
water to top line.
Multiply result x 2.
NO
YES
63368-01 • 08.18