User’s Responsibility
Please Note: Your warranty is subject to user
responsibility. Some items and some conditions resulting from causes other than manufacturing defects are the responsibility of the user of the LakeAir Media or Hepa Air Cleaner and are not covered by the warranty. These are:
2. Periodic checking and cleaning of unit. Failure to clean or replace filter when needed will void warranty.
3. Proper use of controls must be maintained or warranty will be voided.
4. Damage to unit from unsatisfactory operation because of blowing fuses, inadequate electrical service or operation on power supply other than that indicated on the rating plate, or incorrect electrical protection devices used.
5. Damage occurring during transportation or resulting from improper handling.
6. Damage due to accident or resulting from alteration or tampering.
7. Misapplication of product.
The complete LakeAir Media or Hepa Air Cleaner is warranted by Air Aware Inc. to the original purchaser to be free from defects in material and workmanship under normal use and service for a period of one year from the date of purchase. Air Aware’s liability is to be limited to repairing or replacing such products during the warranty period at its option, providing the product is sent prepaid to Air Aware Inc. or an Authorized Service Center and is deemed to the satisfaction of Air Aware Inc. to be defective in any part or portion.
This warranty is in lieu of any other warranty expressed or implied and of all other obligations or liabilities in connection with the sale of the described LakeAir Media or Hepa Air Cleaner. In no case will any claim for consequential damages or labor expenses be allowed. This warranty does not apply to a LakeAir Media or Hepa or any part thereof which has not been operated in accordance with the operating instructions herein contained; where components or other accessories not compatible with the LakeAir Media or Hepa Air Cleaner have been used or attached to it; which has been subject to accident, unauthorized alteration, abuse, damage by flood, fire or acts of nature.
LAKEAIR MEDIA AIR CLEANER
1 YEAR LIMITED WARRANTY
Portable Media air cleaner
Operating and Service Manual
Excel Z (120v) Excel Z (230v) Maxum Z (120v) Maxum Z (230v)
EXCEL PARTS MAXUM PARTS
Part# Description Part# Description
20062 Excel Z Motor 20063 Maxum Z Motor
499052 Fan Blade 495101 Fan Blade
499018 Media Filter 499085 Media Filter
10066 Cover Assembly– Wood grain 10064 Cover Assembly-Wood grain
495142 Chassis 495156 Chassis
10067 Cover Assembly– White 10065 Cover Assembly-White
499027 Optional carbon filter 499005 Optional carbon filter
499024 Optional Super-Max carbon filter
Common Parts
497613 Grey Rocker Switch
497612 Black Rocker Switch
499009 Mounting Feet
10066 Cover Assembly-Black 10064 Cover Assembly-Black
UNPACKING AND OPERATING
INSTRUCTIONS
In order to operate your LakeAir Air Cleaner properly, it is necessary to remove plastic packing material from the media filter inside the unit. (Remove plastic packaging material from the optional carbon after filter inside the unit if included as well).
1. Un-screw and remove the two fasteners from the top of the cabinet.
2. Lift the cover assembly from the chassis and set aside.
3. Take off the protective packing material and discard.
4. Replace the media filter (and carbon after filter if included), then the cover assembly, making sure to include both of the fasteners. NOTE: The fasteners must be in place and secured snugly or the unit will not operate.
Place your LakeAir Air Cleaner in a convenient area in the desired room. If you are using the air cleaner for a specific purpose, such as smoke removal, locate the air cleaner as close as possible to the source. (Such as near a smoking stand.) Care should be taken to allow at least 4-6” of unobstructed space behind the unit so that it will exhaust freely into the room. If, however, you position the unit so that the airflow is parallel to the nearest wall, you need not allow as much free space. For best results the unit should be elevated by placing it on a table or stand. It can also be mounted on a wall, using our convenient wall mount option.
Plug the line cord into a standard household outlet with 120V AC 60 Hz. Caution should be taken to use the unit only on the required voltage, as to do otherwise will void the warranty.
OPERATING AND MAINTENANCE
INSTRUCTIONS
Position the unit and plug it into the proper line voltage before turning it on.
1. To turn unit on, locate the three­position rocker switch on top of the unit. Depress the button to activate the unit on the desired speed; High, Low, or Off (center, flat position). Under normal conditions, the Low position is adequate to keep an average size room clean. With excessive amounts of dust, smoke, or other pollutants present, the air cleaner should be operated on high.
2. To shut the unit off, simply push the button to its center (flat) position and unplug the unit from the line voltage.
Note: Above items are available from your local LakeAir dealer.
TROUBLESHOOTING YOUR LAKEAIR
MEDIA AIR CLEANER
Some of the common causes for malfunction of your air cleaner are listed below. Review them should you have a problem, and perform the corrective measures listed here. If your LakeAir Media Air Cleaner is not restored to proper operation, contact your Dealer, nearest Authorized Service Center, or Air Aware.
Problem Possible Cause Possible Remedy
Air cleaner will not operate Control switch is in Off
Position
Depress power switch to High or Low
Power cord not plugged in Plug in power cord
Blown fuse in household or breaker tripped.
Replace fuse or reset breaker
Cover removed Replace cover
Cover fasteners not tight Tighten fasteners snugly
Small volume of air discharged from unit
Extremely dirty media filter Replace filter according to In-
structions
Plastic packing still on carbon after filter
Remove plastic wrap
Unit not effectively cleaning the air
Media filter dirty Replace according to Instructions
Media filter is not properly installed
Check reassemble instructions
Odors more pronounced than usual
Service life of carbon after filter expired
Air cleaner being used in a confined space
Discard and replace the carbon after filter
Open doors to the adjoining rooms
If any of the problems are not solved to your satisfaction, please contact your Dealer or Air Aware
Maintenance
Your LakeAir Air Cleaner is a high quality, precision piece of equipment designed for long years of satisfactory performance. Adhere to a regular maintenance schedule and no problems should occur. This unit should be checked periodically for “dust load” and replace filter regularly. Under regular conditions the media filter should be replaced every 3-4 months. Under more severe conditions more frequent replacement may be required. Note: Change
filter when noticeably dirty as it will damage the motor if it is not changed frequently enough. To obtain maximum efficiency from your LakeAir Media Air Cleaner it must be kept clean.
In addition to the grilles and filters, care should be taken to keep the rest of the unit clean as well.
Disassembly and Cleaning
1. Turn off unit and disconnect line cord from outlet.
2. Remove fasteners from cover assembly.
3. Lift cover from chassis.
4. Replace media filter and discard old filter.
5. Do not wash the carbon after filter. This filter should be brushed or cleaned with a vacuum cleaner if any dust is present. This filter should also be replaced when there is an indication that it is no longer absorbing odors. Normal replacement is approximately every 3-4 months.
NOTE: TO INSURE PROPER OPERATION, FILTER(S) SHOULD BE REPLACED AT REGULAR INTERVALS. FAILURE TO REPLACE MEDIA FILTER WILL VOID THE WARRANTY.
Reassembly
1. Replace media filter
2. Place the carbon after filter back into the unit if purchased
3. Replace the cover assembly and secure with the fasteners.
4. Before plugging the unit in, make sure the power button is in the Off position. Plug in the line cord and turn the unit on to the High or Low position.
DESCRIPTION OF PARTS
1. COVER ASSEMBLY: The vinyl covered metal cover assembly is secured to the chassis by means of two screw fasteners on top of the unit. The cover assembly includes the two grille sections.
2. CHASSIS: The chassis consists of the base of the Excel and Maxum and has several components of the unit attached to it. The motor and fan, power supply, control switch, and all internal wiring are found in the chassis.
3. OPTIONAL CARBON AFTER FILTER: The carbon after filter is optional in all Excel and Maxum units and is used as an after filter to remove objectionable odors from the cleaned air.
4. MEDIA FILTER: This is the workhorse of the LakeAir Air Cleaner and performs the major function of the air cleaner by removing the particles from the air.
HOW A LAKEAIR UNIT WORKS
In business establishments or in your home, millions of airborne particles are continually being circulated in the air you breathe. A LakeAir Media Air Cleaner removes: smoke, dust, dirt, pollen, and other particulates like a powerful pollution trap.
1. The internal circulating fan draws the dirty air into the system where it first must pass through the outer grille.
2. The air then passes into the
media filter, a revolutionary filter that
has electro statically charge synthetic media.
3. The optional activated carbon filter removes odors and freshens the air.
4. The cleaned and purified air is then returned to the room environment.
SPECIFICATIONS
EXCEL Z 120v
EXCEL Z 230v
MAXUM Z 120v
MAXUM Z 230 v
Input Voltages: 120v 60 Hz
72 Watts
230v 50/60 Hz 120V 60Hz
102 Watts
230v 50/60 Hz
Cleaning Capacity: Low: 70 cfm
High: 110 cfm
Low: 1.98 m3/min. High: 3.12 m3/min.
Low: 210 cfm High: 275 cfm
Low: 5.95 m3/min. High: 7.79 m3/min.
Actual Size: 13” x 17” x 8” 33cm x 43.2cm x
20.3cm
13.5” x 13” x 17” 34.3cm x 33cm x
43.2cm
Actual Weight: 14 lbs. 6.4 kg 17 lbs. 7.7 kg
Shipping Size: 19” x 15.5” x 10” 48.3cm x 39.4cm x
25.4cm
19” x 15.5” x 15.5” 48.3cm x 39.4cm x
39.4cm
Shipping Weight: 19 lbs. 8.6 kg 21 lbs. 9.5 kg
Loading...