Lainox RR1S User Manual

model RR1, model RR1S & model SR1S
STAndARd feATuReS
• 304 stainless steel inside casing
• 304 stainless steel sides and doors
• Top and back panel in treated steel
• Injected polyurethane foam insulation, 3-1/8" thick, 0% CFC
• 3/4" thick insulated floor with access ramp and 304 stainless steel cladding
• Field reversible door
• Internal safety door release
• Scraper seal at bottom of door
• Stainless steel front framework with anti-condensing system
• Coved internal corners with 1/2" radius
• 1-1/4" wide magnetic door seals with anti-dirt, anti-impact rounded profile, and tool-free removal
• Smooth, sealed control panel
• Baseboards for floor adjustment
• Easy maintenance
SR1S – Blast Chiller / Freezer without Condensing Unit
Project Item No. Quantity
BlAST ChilleR/fReezeR
RR1 – Blast Chiller with Condensing Unit
RR1S – Blast Chiller without Condensing Unit
CApACiTy
• Accomodates trollies 30" x 24" x 73" (WxDxH)
• Blast chilling capacity, RR1, RR1S, SR1S: 176 lbs. from 145°F, to 40°F, “to core” within 1 hr. 50 mins.
• Blast freezing capacity SR1S: 242 lbs. from 145°F, to 0°F, “to core” within 4 hrs. 30 mins.
mulTi-poinT fRigipRoBe
• A stainless steel probe with four temperature sensors monitors core temperature of product
• Frigiprobe electronically assists blast chilling and freezing of products accurately regardless of quantity, weight, or thickness
• Blast freezing or chilling is automatically stopped once “core” temperature is reached (0°F to +40°F)
• Blast chilling mode can limit air temperature at the surface to 32°F to prevent surface icing
eleCTRoniC ConTRol
• Blast chilling or freezing controlled with Timer Mode or Frigiprobe Mode
• Timer Mode remembers last time settings
• Temperature maintained after blast chilling or freezing
• Automatic control of defrosting cycle
• Audible signal at start and end of cycle with remote report feature
opTionS & ACCeSSoRieS
Audible alarm
Stainless Steel backside
6 rolls of paper
Fan stops with door open
• Remote alarm signal (output 12 Vdc)
• Temporary self-repair of probes and quick diagnosis of anomalies
• Temperature display in °F or °C
Control panel display
• Alternating digital display of core temperature and time at start of cycle (Frigiprobe mode)
• Alternating digital display of internal temperature and time remaining before end of cycle (Timer mode)
• Lights indicating functions in progress
Communication board and printer
• Serial type RS 232 C port and parallel port, enabling unit to be connected to a PC, to a data processing network or to a printer
• Built-in printer for recording temperature and duration of cycles
RefRigeRATion
Similar for all models
• R404A refrigerant
• Three 11-7/8" diameter fans mounted on a pivoting stainless steel panel for easy maintenance
• One evaporator with fitted thermostatic expansion valve
Model with condensing unit: RR1
• 3 hp hermetic compressor
• Water-cooled condensing unit
• High Pressure controller
(3M) 7/07 Printed in U.S.A.
FR005
B
C
C'
C
C'
A
B
E
2"
6"
9-7/8"
8-5/8"
2-3/8"
7-7/8"
7-7/8"
Top View
C
C'
E
B
A
92-1/2"
78- 3/8"
3-1/8"
3"
E
D
D1
D
D1
B
B
7-7/8"
3
-1/2"
24-1/2"
6-3/4"
37-7/8"
2"
76"
16-1/2"
38-1/2"
30"
7-7/8"
Top View
Side View
With Condensing Unit
Without Condensing Unit
E
A D
D
1
B
3" 3"
42- 5/8" 40-1/2"
9
-1/2
"
8 3 -7/8"
8 0-1/8"
78-3/4"
73-1/4"
Side View
• Water pressure valve
• Drier and liquid indicator
Models without condensing unit: RR1S and SR1S
• Solenoid valve on liquid line
• Refrigeration circuit with light nitrogen pressure
eleCTRiCAl defRoSTing
• Defrosting with three 500 W, stainless steel heaters and fan
• Safety thermostat for defrosting heaters on evaporator
RequiRemenTS
General
• Wall Clearance Top: 15-3/4"
Sides: 2-3/4"
• Ventilation of premises if temperature is higher than 100°F, taking into
account the unit’s heat emission
• Keep away from sources of heat
• Install gutter and siphoning tube
Electrical
• Electrical power supply must conform to local electrical codes
regulation
• RR1 (with condensing unit) Voltage: 208-240 V / 60 / 3, with ground
Installed power: 5800 W
Maximum fuse size: 35 A
Minimum circuit ampacity: 20 A
Breaker: 30 A
Condenser pressure: 29 psi min. – 145 psi max.
3/8" supply and evacuation connection
• RR1S, SR1S (remote condensing unit) Voltage: 208-240 V / 60 / 1, with ground
Installed power: 8,000 BTU/hr.
Minimum circuit ampacity: 12 A
Breaker: 20 A
3/8" supply and evacuation connection
Remote condensing unit
Compressor unit with crankcase heater
Condenser (air or water cooled)
Liquid receiver, liquid indicator, and drier-filter
High pressure controller safety device
Condenser pressure controller
Oil separator if semi-hermetic compressor unit (SR1S)
Electrical box for power supply and all connection protections
for the condensing unit Remote condensing unit needs to have “pump down” capability
Refrigerating capacity:
RR1S Evaporation temperatures 32°F: 31,000 BTU/hr. RR1S Evaporation temperatures -4°F: 11,000 BTU/hr. SR1S Evaporation temperatures -4°F: 41,000 BTU/hr. SR1S Evaporation temperatures -40°F: 15,000 BTU/hr.
Consult installer for remote condensing unit requirements
AppRovAlS
RR1, RR1S & SR1S
Net weight RR1: 541 lbs. Net weight RR1S, SR1S: 441 lbs.
A. Electrical power supply B. De-icing water runoff C. Water inlet
fRiginox – uSA
PO Box 4129 Winston-Salem, NC 27105 800/551-8795 • Ph: 336/661-0257 Fax: 336/661-9546 sales@moffat.com www.friginoxusa.com
C1. Water outlet D. Liquid line D1. Suction line
fRiginox – CAnAdA
P.O. Box 301, Jordan Station, Ontario L0R 1S0 800/263-5798 • Ph: 905/562-4195 Fax: 905/562-4618
E. Duct
sales@moffat.com www.friginoxusa.com
Due to an ongoing value analysis program at Friginox, specifications contained in this catalog are subject to change without notice.