BLAST CHILLER/FREEZER
Chiller for Cooked Dishes and Pastries / Combined Blast Freezer
STANDARD FEATURES
• 304 stainless steel inside casing
• 304 stainless steel top, sides and doors
• Right hinged door with automatic return pivot and 90° fixed position (field reversible door)
• Stainless steel front framework with anti-condensing system
• Injected polyurethane foam insulation, 2-3/8" thick, 0% CFC
• Run-off plug and bottom of chiller are angled to evacuate water
• Coved internal corners with 1/2" radius
• Tool-free removal of internal accessories
• 1-1/4" wide magnetic door seals with anti-dirt, anti-impact rounded profile, and tool-free removal
• Smooth, sealed control panel
• Easy maintenance
MULTI-POINT FRIGIPROBE
• A stainless steel probe with four temperature sensors monitors core temperature of product
• Frigiprobe electronically assists blast chilling and freezing of products accurately regardless of quantity, weight, or thickness
• Blast freezing or chilling is automatically stopped once “core” temperature is reached (- 0.4°F to +40°F)
• Blast chilling mode can limit air temperature at the surface to 32°F to prevent surface icing
CAPACITY
• 10 levels to accomodate 12" x 20" hotel pans or a maximum of 26 levels (levels at 1-1/2" increments)
• Blast chilling capacity: 110 lbs. from 145°F,to 50°F, “to core” within 1 hr. 50 mins.
• Blast freezing capacity: 55 lbs. from 145°F,to -0.4°F, “to core” within 4 hrs. 30 mins.
ELECTRONIC CONTROL
• Blast chilling or freezing controlled with Timer Mode or Frigiprobe Mode
• Timer Mode remembers last time settings
• Temperature maintained after blast chilling or freezing
• Automatic control of defrosting cycle
• Audible signal at start and end of cycle with remote report feature
• Remote alarm signal (output 12 Vdc)
• Temporary self-repair of probes and quick diagnosis of anomalies
• Temperature display in °F or °C
Control panel display
• Alternating digital display of core temperature and time at start of cycle (Frigiprobe mode)
• Alternating digital display of internal temperature and time remaining before end of cycle (Timer mode)
• Lights indicating functions in progress
Communication board
• Serial type RS 232 C port and parallel port, enabling unit to be connected to a PC, to a data processing network or to a printer
OPTIONS & ACCESSORIES
Pair of U type runners Audible alarmRemote printer (records temperatures and cycle times)Wall mounting printer6 rolls of printer paperStainless steel casters with braking mechanism
(3M) 12/03 Printed in U.S.A.
INV NO.
Project Item No. Quantity
REFRIGERATION
• Air-cooled condensing unit
• 2.5 hp hermetic compressor
• R404A refrigerant
• Drier and liquid indicator
• One evaporator with thermostatic expansion valve fitted with a M.O.P.-4°F
• Two fans, 11-7/8" in diameter mounted on a pivoting stainless steel panel for easy maintenance
• High Pressure controller
• Defrosting with forced operation of fan
REQUIREMENTS
General
• Wall Clearance – Top: 15-3/4" – Sides: 4"
• Ventilation of premises if temperature is higher than 100°F, taking into account the unit’s heat emission
• Keep away from sources of heat
Clearance
• Top : 15-3/4"
• Sides : 4"
Electrical
• Electrical power supply must conform to regulation
• Unit supplied with 6' 7" long cable without plug
• Voltage: 208-240 V / 60 / 3, with ground
• Installed power: 16,000 BTU/hr.
• Maximum fuse: 20 A
• Minimum circuit ampacity: 15 A
• Breaker: 20 A
Draining
• Install siphoning tube for draining water
Due to an ongoing value analysis program at Friginox, specifications contained in this catalog are subject to change without notice.
7-1/ 2"
44 -1/2"
22- 7/ 8 "
6"
4" M in.
31-1/8 "
15-1/8"
30- 3/8"
75"
2-3/8"
4- 3/4"
21"
17-1/2 "
59"
Front View Side View Top View