Inventory of Contents Features Setting Up Battery Installation Function keys LCD Screen and Settings Manual Settings Weather Forecast and Tendency Indoor Temperature Display and Indoor MIN/MAX Records Outdoor Temperature Display and Outdoor MIN/MAX Records 915 MHz Reception Mounting Troubleshooting Maintenance and care Specification Warranty Information
2
Page
This product offers:
INVENTORY OF CONTENTS
1. Wireless Temperature Station
2. Wireless Temperature Sensor (TX38U) and mounting bracket.
3. Instruction Manual and Warranty Card.
ADDITIONAL EQUIPMENT (not included)
1. 1 Philips screwdriver.
2. 2 Fresh “AAA” IEC LR3, 1.5V Alkaline Batteries
3. 2 Fresh “AA” IEC LR6, 1.5V Alkaline Batteries.
INSTANT TRANSMISSION is the state-of-the-art new wireless transmission technology, exclusively designed and developed by LA CROSSE TECHNOLOGY. INSTANT TRANSMISSION offers you an immediate update (every 27.5 seconds!) of all your outdoor data measured from the transmitters: follow your climatic variations in real-time!
3
FEATURES: The Temperature Station
LCD
Displa
Function
Keys
Temperature display in degrees Fahrenheit (°F) Indoor and Outdoor temper ature display with MIN/MAX recording All MIN/MAX recordings can be reset Low battery indicator Wireless transmission at 915 MHz
4
Hanging hole
Battery compartment cover
Foldout Stand
Outdoor signal reception intervals at 27.5-second Table standing or wall mounting
The Outdoor Temperature Transmitter
SETTING UP: NOTE: The temperature station will receive only outdoor transmitter only.
Remote transmission of outdo o r tem pera tu re t o
Temperature Station by 915 MHz
Shower proof casing Wall mounting case Mounting at a sheltered place. Avoid direct rain
and sunshine
1. First, insert the batteries into the Temperature transmitter. (see “Install and replace batteries in the Temperature transmitter“).
2. Immediately after and within 2 minutes, insert the batteries into Tempe rature station (see “Install and replace batteries in the Temperature station”). Once the batteries are in place, all segments of the LCD will light up briefly. Then the indoor temperature will de display. If these are not displayed after 60 seconds, remove the batteries and wait for at least 10 seconds before reinserting them.
3. After inserting the batteries into the transmitter, the Temperature station will start receiving data from the transmitter. The outdoor t emperature and the signal reception icon should then be displayed on the Temperature station. If this does not happen after 3 minutes, the batteries will need to be removed from both units and reset from step 1.
4. In order to ensure sufficient 915 MHz transmission however, this should under good conditions be a distance no more than 330 feet (TBC) (100 meters-TBC) between the final position of the Temperat ure Station and the transmitter (see notes on “Mounting” and “915 MHz Re c e ption”).
Note:
If the signal reception is not successful on the first fr equency (915MHz) for 22 seconds,
the frequency is changed to 920MHz and the learning is tried another 22 seconds. If still
not successful the reception is tried for 22 seconds on 910MHz. This will also be done for re-synchronization.
INSTALL AND REPLACE BATTERIES IN THE TEMPERATURE TRANSMITTER
start-up and this code must be received and stored by the Weather station in the first 3 minutes of power being supplied to it
The Temperature Transmitter uses 2 x AAA, IEC LR3, 1.5V battery. To install and replace the batteries, please follow the steps below:
1. Pull out the battery holder at the bottom of the transmitter.
2. Insert the batteries, ob serving the correct polarity (see marking).
3. Replace the battery holder on the unit.
Note:
In the event of changing batteries in any of the units, all units need to be reset by following the setting up procedures. This is because a random security code is assigned by the transmitter at
5
INSTALL AND REPLACE BATTERIES IN THE TEMPERATURE STATION
BATTERY CHANGE:
It is recommended to replace the batteries in all units on an annual basis to ensure optimum accuracy of these units.
Please participate in the preservation of the environment. Return
used batteries to an authorised depot.
6
The Temperature station use s 2 x AA, IEC LR6,
1.5V batteries. To install and replace the batteries, please follow the steps below:
1. Remove the cover at the back of the weather station.
2. Insert batteries observing the correct polarity (see marking).
3. Replace compartment cover.
7
8
FUNCTION KEYS:
y
Weather station:
The weather station has 2 easy to use function keys.
IN/OUT ke
IN/OUT key
To toggle between the indoor and outdoor temperature display
MIN/ MAX key
To toggle between the MIN/MAX indoor and outdoor temperature display Press and hold to reset at the MIN/MAX indoor and outdoor temperature records
9
MIN/MAX key
LCD SCREEN AND SETTINGS:
* When the outdoor signal is successfully received by the Temperature Station, this icon will be switched on. (If not successful, the icon will not be shown in LCD) So user can easily see whether the last reception was successful (icon on) or not (icon off).
Receiver low battery icon
Transmitter low battery icon
Outdoor signal reception icon*
10
Temperature display in ºF
DISPLAY OF INDOOR TEMPERATURE READING AND INDOOR MIN/MAX RECORDS:
1. Press the IN/OUT key to view the current indoor temp erature
2. Press the MIN/MAX key to view the MIN record
3. Press again the MIN/MAX key to view the MAX record.
4. Press the MIN/MAX once more to return to current indoor temperature.
Indoor data icon
DISPLAY OF OUTDOOR TEMPERATURE READING AND OUTDOOR MIN/MAX RECORDS:
1. Press the IN/OUT key to view the current outdoor temperature
2. Press the MIN/MAX key to view the MIN record
3. Press again the MIN/MAX key to view the MAX record.
Indoor Temperature in °F
MIN icon
MAX icon
11
4. Press the MIN/MAX once more to return to current outdoor temperature.
Outdoor data icon
RESETTING THE INDOOR AND OUTDOOR MAXIMUM/ MINIMUM RECORDS
Press and hold the MIN/MAX key for about 2 seconds, this will reset all the indoor and outdoor MIN/MAX temperature records to the current indoor and outdoor temperatures.
915 MHz RECEPTION
The Temperature station should receive the temperature data within 5 minutes after set-up. If the temperature data is not received 5 minutes after setting up (not successfully continuously, the outdoor display shows “- - -”), please check the following points:
1. The distance of the t emperature station or transmitter should be at least 1.5 to 2 meters away from any interfering sources such as computer monitors or TV sets.
Outdoor Temperature in F
MIN icon
MAX icon
12
2. Avoid positioning the Temperature station onto or in the immediate proximity of metal window frames.
3. Using other electrical products such as headphones or speakers operating on the same signal frequency (915MHz) may prevent correct signal transmission and reception.
4. Neighbours using electrical devices operating on the 915MHz signal frequency can also cause interference.
Note:
When the 915MHz signal is received correctly, do not re-open the battery cover of either the transmitter or Tempera ture station, as the batteries may spring free from the co ntacts and force a false reset. Should this happen accidentally then reset all units (see Setting up above) otherwise transmission problems may occur. The maximum transmission range is 330 feet (TBC) (100 m- TBC) from the transmitter to the Temperature station (in open space). However, this depends on the surrounding environment and interference leve ls. I f no recepti on is po s sibl e despite the observation of these factors, all system units have to be reset (see Settin g up).
MOUNTING POSITIONING THE TEMPERATURE STATION:
The Temperature Station has been designed to be hung onto wall or free standing.
13
To wall mount
Free standing
Choose a sheltered place. Avoid direct rain and sunshine. Before wall mounting, please check that the outdoor temperature values can be received from the desired locations.
1. Fix a screw (not supplied) into the desired wall, leaving the head extended out th e by about 5mm.
2. Remove the stand from the Temperature Station by pulling it away from the base and hang the station onto the screw. Remember to ensure that it locks into place before releasing.
With the detachable stand, the temperature station can be placed onto any flat surface.
14
POSITIONING THE TEMPERATURE TRANSMITTER:
To wall mount:
The Transmitter is supplied with a holder that may be attached to a wall with the two screws supplied. The Transmitter can also be position on a flat surface by securing th e stand to the bottom to the Transmitter.
1. Secure the bracket onto a desired wall using the screws and plastic anchors.
2. Clip the remote temperature sensor onto the bracket.
Note:
Before permanently fixing the transmitter wall base, place all units in the desired locations to check that the outdoor temperature reading is receivable. In event that the signal is not received, relocate the
15
transmitters or move them slightly as this may help the signal reception. CARE AND MAINTENANCE:
Extreme temperatures, vibration and shock should be avoided as these may cause
damage to the unit and give inaccurate forecasts and readings.
When cleaning the display and casings, use a soft damp cloth only. Do not use
solvents or scouring agents as they may mark the LCD and casings.
Do not submerge the unit in water. Immediately remove all low powered batteries to avoid leakage and damage. Replace
only with new batteries of the recommended type.
Do not make any repair attempts to the unit. Return them to their original point of
purchase for repair by a qualified engineer. Opening and tampering with the unit may invalidate their guarantee.
Do not expose the unit s to extreme and sudden temperature changes, this may lead
to rapid changes in forecasts and readings and thereby reduce their accuracy.
SPECIFICATIONS: Temperature measuring range: Indoor : 14.1°F to +140°F with 0.2°F resolution (“OF.L” displayed if out side this range) Outdoor : -3.8°F to +140°F with 0.2°F resolution
16
(“OF.L” displayed if out side this range) Indoor temperature checking interval : every 27.5 seconds Outdoor data reception : every 27.5 seconds Transmission range : 70 meters or 100 meters (T.B.C) Power consumption: Temperature station : 2 x AA, IEC LR6, 1.5V Temperature transmitter : 2 x AAA, IEC, LR3 1.5V Battery life cycle (Alkaline batteries recommended): Temperature station : Approximately 24 months Temperature transmitter : Approximately 12 months Dimensions (H x L x W) Temperature station : 3.85" x 2.91" x 1.14" Temperature transmitter : 3.41" x 0.55" x 1.27"
La Crosse Technology, Ltd provides a 1-year limited warranty on this product against manufacturing defects in materials and workmanship.
WARRANTY INFORMATION
17
This limited warranty begins on the original date of purchase, is valid only on produ cts purchased and used in North America and only to the original purchaser of this product. To receive warranty service, the purchaser must contact La Crosse Technology, Ltd for problem determination and service procedures. Warranty service can only be performed by a La Crosse Technology, Ltd authorized service center. The original dated bill of sale must be presented upon request as proof of purchase to La Crosse Technology, Ltd or La Crosse Technology, Ltd’s authorized service center.
La Crosse Technology, Ltd will repair or replace this product, at our option and at no charge as stipulated herein, with new or reconditioned parts or products if found to be defective during the limited warranty period specified above. All replaced parts and products become the property of La Crosse Technology, Ltd and must be returned to La Crosse Technology, Ltd.
Replacement parts and products assume the remaining original warranty, or ninety (90) days, whichever is longer. La Crosse Technology, Ltd will pay all expenses for labor and materials for all repairs covered by this warranty. If necessary repairs are not covered by this warranty, or if a product is examined which is not in need or repair, you will be charged for the repairs or examination.
The owner must pay any shipping charges incurred in getting your La Crosse Technology, Ltd product to a La Crosse Technology, Ltd authorized service center.
18
Your La Crosse Technology, Ltd warranty covers all defects in material and workmanship with the following specified exceptions: (1) dama ge caused by accident, unreasonable use or neglect (including the lack of reasonable and necessary maintenance); (2) damage occurring during shipment (claims must be presented to the carrier); (3) damage to, or deterioration of, any accessory or decorative surfa ce; (4) damage resulting from failure to follow instructions contained in your owner’s manual; (5) damage resulting from the performance of repairs or alterations by someone other than an authorized La Crosse Technology, Ltd authorized service center; (6) units used for other than home use (7) applications and uses that this product was not intended or (8) the products inability to receive a signal due to any source of inte rf ere nce .
This warranty covers only actual defects within the product itself, and does not cover the cost of installation or removal from a fixed installation, normal set-up or adjustments, claims based on misrepresentation by the seller or performance variations resulting from installation-related circumstances.
LA CROSSE TECHNOLOGY, LTD WILL NOT ASSUME LIABILITY FOR INCIDENTAL, CONSEQUENTIAL, PUNITIVE, OR OTHER SIMILAR DAMAGES ASSOCIATED WITH THE OPERATION OR MALFUNCTION OF THIS PRODUCT. THIS PRODUCT IS NOT TO BE USED FOR MEDICAL PURPOSES OR FOR PUBLIC INFORMATION. THIS PRODUCT IS NOT A TOY. KEEP OUT OF CHILDREN’S REACH.
19
This warranty gives you specific legal rights. You may also have other rights specific to your State. Some States do no allow the exclusion of consequential or incidental damages therefore the above exclusion of limitation may not apply to you. For warranty work, technical support, or information contact:
La Crosse Technology, Ltd
2809 Losey Blvd. S. La Crosse, WI 54601 Phone: 608.782.1610
Fax: 608.796.1020
e-mail: support@lacrossetechnology.com
sales@lacrossetechnology.com
(information on other products)
web: www.lacrossetechnology.com
Please visit: www.lacrossetechnology.com/9007
Question? Instructions?
(warranty work)
20
All rights reserved. This handbook must not be reproduced in any form, even in excerpts, or duplicated or processed using electronic, mechanical or chemical procedures without written permission of the publisher.
This handbook may contain mistakes and printing errors. The information in this handbook is regularly checked and corrections made in the next issue. We accept no liability for technical mistakes or printing errors, or their consequences. All trademarks and patents are acknowledged.
EJIN9007L210