Lacanche FMH Installation, Operation & Maintenance Instructions Manual

Page 1
FMH Range Hoods
W1103 Revision: 14/10/2011 1
FMH Range Hoods
Installation, Operation & Maintenance Instructions
Fourneaux de France Ltd
Unit 3 Albion Close, Newtown Business Park, Poole Dorset, BH12 3LL
Tel 01202 - 733011 Email [email protected] www.fdef.co.uk
Page 2
FMH Range Hoods
W1103 Revision: 14/10/2011 2
FMH Range Hoods
SECTION 1. INTRODUCTION
SECTION 2. EXTRACTION PERFORMANCE
SECTION 3. IMPORTANT INFORMATION
SECTION 4. INSTALLATION
SECTION 5. OPERATING INSTRUCTIONS
SECTION 6. MAINTENANCE
SECTION 7. SPECIFICATIONS
SECTION 8. HOOD DIMENSIONS
Page 3
FMH Range Hoods
W1103 Revision: 14/10/2011 3
SECTION 1. INTRODUCTION
Your range cooker is a semi-professional unit which gives you the power and flexibility to realise your full potential in the kitchen. Inevitably, during the cooking process, there will be heat, vapours and fumes produced. Your FMH extractor has been designed to complement the range cooker both in looks and performance in order to create the ideal environment for creative cook­ing.
SECTION 2. EXTRACTION PERFORMANCE
This hood is designed for ducting out, i.e. duct to an outside wall. To obtain the best possible extraction performance use 150mm diameter ducting or larger. Wherever possible utilise rigid circular pipe or a flat channel equivalent. Avoid using flexible ducting (except for runs of less than 1.5m) as this is not smooth on the interior and can cause air flow restrictions. Semi rigid ducting can be used. Please note ducting kits and ducting components are optional accessories and have to be ordered - they are not supplied with the hood.
The most important influence on the performance of the extractor is the de­sign of the ducting which takes the exhaust air from the extractor to the out­side wall louvre. The duct route should be a prime consideration during the initial stages of the kitchen design. Please note the following:
The extractor is provided with a spigot suitable for connecting 150mm
diameter duct. *
Note: 150mm is the minimum duct diameter consistent with efficient
extraction.
The exhaust duct route length should be kept as short as possible with
as few bends as possible.
The most efficient configuration is to duct straight through an outside
wall so try to position the cooker against an outside wall when designing your kitchen layout.
The hood can be vented either to the top exhaust or the rear exhaust
position. Use the position which gives the shortest duct route length and least number of bends. (The blower will need to be rotated for ducting directly through the rear exhaust position.)
A route with more than two 90
o
bends will significantly degrade the per­formance of the extraction system. If possible, avoid having a 90o bend at the extractor exhaust spigot; keep bend radii as large as possible to maintain a smooth airflow without vortices; avoid kinks in flexible duct­ing; pull flexible ducting taut over straight runs to ensure that the internal surface is as smooth as possible.
Duct runs in excess of 5 metres are not recommended and will seriously
impair efficiency - if you are concerned then please call for advice.
SECTION 3. IMPORTANT INFORMATION
The following minimum headroom is required to accommodate the cooker and hood:
The minimum distance between the range hob burners and the bottom of the
extractor is essential to prevent overheating of the extractor and its compo­nents.
If you are fitting a splashback then the cooker-to-hood clearance is dictated by the splashback height (unless you choose to run the splashback down behind the cooker). Splashbacks are best fitted before the hood.
Please also note that a 90o bend in the flexible ducting will require 215mm minimum headroom to give a smooth radius with no kinking.
Requirements of the relevant authorities concerning the discharge of exhaust air must be complied with.
Attention:
This appliance requires an earth connection.
Ensure that the supply voltage corresponds to that marked on the rating label inside the extractor.
The extractor must be isolated from the electrical supply before carrying out any cleaning or maintenance operations.
Pay particular attention to fire risk when frying. To minimise the risk of fire, all instructions relating to cleaning the grease filters and removing grease deposits must be adhered to.
Do not flambé under the extractor.
SECTION 4. INSTALLATION
Do not throw away the box and any internal packaging until installation is fully completed - the packaging may be required in the unlikely event that
hood must be returned.
4.1 Remove the Grease Filters
Place extractor on its backplate on a horizontal surface.
To remove the grease filters pull/lift the filter release lever away from the hood base. This releases the retaining clips allowing the filter to be carefully lifted away from the hood. Take care not to scratch the hood.
The internal fixing holes, blower assembly and spigot blanking plate can now be accessed through the opening in the baseplate. *
4.2 Blower Exhaust Position
The hood can be vented either to the top exhaust or the rear exhaust posi­tion. Each exhaust position has 4 fixing points onto which can be attached either the blower assembly or a blanking plate. *
Position the blower assembly in the chosen exhaust position and the blanking plate in the unused position using the original fixings and washers supplied .*
When changing the exhaust position, care should be taken not to excessively pull or twist the cable attached to the blower.
4.3 Duct Installation
Make holes in the wall or ceiling to take the 150mm diameter ducting from the extractor exhaust spigot to the outside. *
The exhaust duct route length should be kept as short as possible with as few bends as possible - see Section 2.
An external weather louvre designed for connection to 150mm ducting or larger should be used to terminate ductwork on an external wall - an airbrick must never be used.
* 1400mm, 1500mm & 1800mm wide internal fan models have two sets of blower assemblies and blanking plates. The 2200mm wide model has 3 blower assemblies. Each blower assembly has a separate exhaust spigot for independent ducting to the outside - i.e. you must run 2 or 3 separate 150mm ducts.
FMHE Models supplied for connection to the high performance external fan are supplied with two exhaust spigots fitted - two 150mm ducts should be run to the external fan which has it’s separate installation instructions.
Cooker-to-hood clearance (minimum): Recommended clearance range
750 mm 800 - 850 mm
Hood height including standard chimney: 592 - 745 mm
Minimum ceiling height with standard chimney: 2242mm
The exhaust air must not be discharged into a flue which is used for exhausting fumes from appliances supplied with energy other than electricity, e.g. oil or gas­fired central heating boilers, gas-fired water heaters, etc.
Warning
The following is a requirement of UK and European legislation and is in the interests of your safety.
If the room where the cooker hood is to be used contains a fossil fuel burning appliance such as a gas or oil central heating boiler, then its flue must be of the room sealed or balanced flue type. A ducted hood is not suitable for use in a room where any open flue is in use, as dangerous fumes of combustion can be sucked back in to the room. This would include the following open flue appliances – central heating boilers, coal fires, log fires, gas fires, wood burning stoves etc. Therefore, if you have an open flue fossil fuel burning appliance in your kitchen, you are automatically compelled to select a hood that is capable of working in recycling mode.
FMH Range Hoods
Page 4
FMH Range Hoods
W1103 Revision: 14/10/2011 4
4.4 Fixing the Hood to the Wall
If you are fitting a splashback it should usually be fitted before the hood.
Note: The chimney can be removed to ease handling of the hood.
The supporting wall must be of good quality, have an even surface and be sturdy enough to support the extractor.
Fixings must be used which are suitable for the type of wall construction.
Fixing the hood to the wall requires a minimum of 2 people.
No wall fixingsare provided.
Method
Note: Figures referenced in this section can be found on Page 3.
Mark a horizontal line (A) denoting the hood’s bottom edge - if you have already fitted a splashback then the top edge of this will serve. A vertical centre line up to the desired finished chimney height will also help you to accurately position the hood and chimney bracket.
Remove the grease filters to gain access the internal fixing holes. Mark the positions of the hood fixing hole centres, (see Figure 2 “Example of universal hood fixing detail”. Note: This shows a typical hood installation and is not intended to accurately represent the geometry of your hood. Offer the hood up to the wall in the desired position and mark the wall through the fixing holes in the hood rear. This is a 2 person job.
Mark and prepare a hole(s) suitable to accommodate 150mm diameter ducting (160mm min). If using the rear exhaust spigot position then accu­racy is critical - see Figure 1.
Secure the hood, using fixings suitable for the wall construction, in the previously marked positions. This is a 2 person job.
Tip: for rear exit you may have to connect the ducting prior to fixing the hood to the wall - rigid ducting is strongly recommended.
Unscrew the chimney bracket from the inner chimney and mark the posi­tions of the chimney bracket fixing holes - the central hole is for viewing your centre line (see Figure 3).
Tip: the bracket finishes flush with the chimney top. You may find it easier to slide the chimney up to the desired height and mark the position of the top corners—you can then line the top of the chimney bracket up with these marks.
Secure the chimney bracket, using fixings suitable for the wall construc­tion, in the previously marked positions (see Figure 3).
Connect the ducting and electrical supply cord as described in section 4.5 and 4.6.
Slide the inner chimney over the bracket and secure using the screws previously removed.
4.5 Connecting the Ducting
Connect ducting to extractor exhaust spigot. You may find this easier with the chimney removed. The chimney is attached using M4 machine screws which can be accessed through the filter opening(s). For rear exit exhaust positions the duct should be attached prior to fixing the extractor to the wall.
When the extractor is in position, check that the duct has not been flattened or kinked along its route.
Connect the ducting to the wall louvre or alternative outside termination.
Secure the louvre to the outside wall. Ensure that any air fins are directed downwards.
Refit the grease filters.
4.6 Electrical Installation
The extractor is a stationary appliance designed to be connected by fixed wiring to the electrical supply. A competent electrical technician must per­form the electrical installation.
The extractor must be fed from a 220—240Vac single phase electrical sup­ply using a switched spur fitted with a 3A fuse. The spur should be located such that the supply can be disconnected from the extractor using the switch after installation (adjacent to the extractor/cooker is best). The means of disconnecting from the supply must have a minimum contact separation of 3mm in all poles. Alternatively a means of disconnection in the fixed wiring according to the relevant wiring regulations must be fitted.
A supply cord for connecting the extractor to the spur is included.
The mains supply is connected to the free end of this cord as follows:
SECTION 5. OPERATING INSTRUCTIONS
Switch power on at the fused spur.
The extractor has 6 push-buttons which illuminate when selected. Their functions are summarised below.
Note: 2200mm model has 3 sets of controls for independent control of each fan).
The extractor controller will automatically switch off the appliance if there has been no operator action for 4 hours.
After 30 hours accumulated running GREASE FILTER SATURATION will be signaled by all 6 indicators flashing. Reset by pressing Push­button FAN OFF (delay).
SECTION 6. MAINTENANCE
Regular maintenance is essential to ensure good performance and long-life.
To clean the stainless steel surfaces of the extractor use a proprie­tary cleaning agent. Do not use abrasive cleaning materials or prod­ucts.
Clean the grease filters in a dishwasher or by hand-washing in hot water and detergent. Wash the filters at least every 2 months ­sooner if the extractor is used extensively.
To maintain the immaculate appearance of the extractor, and to min­imise fire risk, ensure that grease deposits on the extractor surfaces are kept to a minimum by regular cleaning.
Should you wish to clean the hood internally (accessed when the filters are removed) then you must first isolate (switch off) the electrical supply to the hood at the switched spur.
To access the halogen lamps for replacement prise off the chrome ring immediately surrounding/retaining the frosted glass with a suita­ble flat implement (eg. screwdriver), taking care not to scratch or damage the light assembly (see picture below). Only replace with bulbs of the same type and rating as originally supplied (12V 20W G4 LV halogen capsule lamp).
Light Assembly
SECTION 7. SPECIFICATIONS
ELECTRICAL HAZARD
DISCONNECT ELECTRICAL SUPPLY
BEFORE PROCEEDING FURTHER
LIGHTS ON/
OFF
FAN ON
SPEED 1
FAN OFF
(Immediate)
FAN ON
SPEED 2
FAN ON
SPEED 3
FAN ON
SPEED 4
FAN OFF
Delayed for
10 Minutes
to clear
fumes
Nominal airflow free air (internal fan)
Nominal airflow in free air (EC310 wall fan)
1,000 m3/hr 3,000 m3/hr
Supply voltage: 220-240V~ 50Hz
Halogen lamp voltage: 12V
Blower power input: 250W per fan
Halogen lamp power:
2 x 20W Single Fan 4 x 20W Twin Fan 5 x 20W Triple Fan
Total power:
290W Single Internal Fan 580W Twin Internal Fan 850W Triple Internal Fan EC310 Wall fan models 610W
Fuse size for electrical supply:
3A Single Internal Fan 5A All other variants
Blower spigot diameter: 150mm
Core
Live Neutral Protective Earth
Core Colour
Brown Blue Green/Yellow
Page 5
FMH Range Hoods
W1103 Revision: 14/10/2011 5
Figure 2
Example of universal Hood Fixing Detail
SECTION 8. HOOD DIMENSIONS
Figure 3
Universal Chimney Detail
Notes
Two tone (painted) models have a stainless plinth section and an enameled upper canopy and chimney.
Multiplefan models have multiple independent spigots for connection to separate 150 ducts - see following pages..
Specific model details can be found on subsequent pages
Line A
Fourneaux de France Ltd
Unit 3 Albion Close, Newtown Business Park, Poole Dorset, BH12 3LL
Tel 01202 - 733011 Email [email protected] www.fdef.co.uk
Page 6
FMH Range Hoods
W1103 Revision: 14/10/2011 6
FMH 1000
FMH 1100
FMH/FMHE 1400
Page 7
FMH Range Hoods
W1103 Revision: 14/10/2011 7
FMH/FMHE 1500
FMH/FMHE 1800
FMH 2200
FMHE 2200 Remote Fan Version