General Safety Precautions
To Prevent Overheating
The recommended clearances and other precautions given in these instructions must be observed to prevent overheating. In addition, units should not be positioned where they are likely to become covered by curtains/fabrics or thermal insulation materials in a roof space or similar building void. The unit should not be left resting on a carpet.
Other Precautions
These appliances are not waterproof. They are for indoor use only and must not be posi­tioned where they could be exposed to dripping or splashing water. Objects containing liquids should not be placed on or near the appliance. To prevent risk of fire, keep the unit and attached wiring well away from naked flames.
Fitted Mains Plug
These appliances are supplied with a standard fixed plug already fitted. If this is not suitable, refer to the instructions below. If you need to change the fuse in this plug, a 3Amp fuse to BS1362 carrying the ASTA or BSI approved mark must be used. Always re-fit the plastic fuse carrier when replacing the fuse.
Changing the Plug
If the fitted mains plug is not suitable for the socket outlet in use, it should be cut off and an appropriate new plug fitted. Any instruction supplied with the plug should be followed. The Brown wire must be connected to the live (L) terminal of the plug and the Blue wire to the neutral (N) terminal. Neither wire should be connected to the earth (E) terminal of a 3-pin plug (this appliance does not require an earth connection to the 3 pin plug). Ensure that the cord grip in the plug is correctly used and clamps the sheath of the cord firmly. Fuse Rating: If the new plug is a fused type, the fuse fitted should be rated at no more than 3 Amp. Caution: The old plug should be disposed of promptly since it would be dangerous if plugged into a live socket.
2 –Year Guarantee
Your distribution unit is guaranteed against faulty components or poor workmanship for
This guarantee does not cover accidental or malicious damage (Including damage from natural causes such as lightening) and will be invalidated by installation or use other than in accordance with these instructions, repair or attempted repair other than by the
manufacturer, or open or removal of the case. This does affect your statutory rights.
Labgear Reserve the right to modify their designs or specifications, In the light of future developments, without prior notice. Performance figures quoted are typical and subject to normal manufacturing and service tolerances
For further information or any queries please contact
Customer Careline: 08457 573 479 (Local rate – UK only)
Technical Support: technical@philex.com
4
a period of two years from the date of purchase.
Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with your Local Authority for recycling advice.
© Philex Electronic Ltd. 2008 V2
Installation Instructions
Introduction
These fully screened general-purpose 4, and 8 way amplifiers are ideal for distributing TV, FM, DAB radio, Satellite and CCTV signals. There are separate inputs for each of these signal sources.
The HDU641 and HDU681 have a switch which should be set to ‘SAT’ if a satellite receiver is included in the system, or switched to ‘UHF & CCTV’ if only using the UHF/CCTV inputs (this links the downlink and uplink).
All units are suitable for handling digital terrestrial TV (DTT /Freeview) signals in addition to analogue signals. Distribution of DTT signals requires careful attention to signal levels for satisfactory results.
Applications
All antenna cables should be cabled direct to the loft (using PF100 or similar digital cable) where they are individually connected to the Home Distribution Unit. The unit combines the FM, DAB, UHF TV, CCTV, LNB 1 and LNB 2 signals together and distributes them via the down link to the Master point. LNB 1 has a dedicated input and output.
1. Satellite - The wiring diagram on page 2 shows how to make connections. The cable from the DOWNLINK OUT on the HDU feeds into the TRIPLEXED INPUT on the rear of the main outlet plate, if you are fitting SKY+™ or Sky HD™ a second connection from LNB 1 OUT is fed down to the Master point on a separate cable, straight through to the SAT 2 INPUT on the back of a Quad outlet plate (PSW351T or PSW241) or to a separate single F outlet (PSW111) if preferred.
To view satellite and TV signals from other outlets a return feed needs to be run from the RF2 output of the digital satellite receiver to the UPLINK IN socket of your HDU. This can be made via a combination socket that has an integrated coax RETURN socket (PSW351T or PSW242T) or by fitting a separate single coax RETURN socket (PSW111).
There are several different options for outlet plates at your Master point - see the table on page 2 and choose an outlet or a combination of outlets according to your requirements and according to what outlets are already in place.
2. Radio - the FM and DAB signals are split internally to feed both the Downlink and the remote rooms. This does not apply to the UHF TV signal, this must come from the Uplink.
3. The CCTV input needs to be modulated. If CCTV is not required terminate input with plug supplied.
Note: All HDU distribution units have a 6mm These products must use non-isolated fully screened outlet plates (such as the PSW range).
Installation
Important note: attention is drawn to the General Safety Precautions Panel on page 4 which contains advice referring to safe installation and operation of these products.
2
Earth Connection to comply to EN 50083-1.
SAT Switch
1
Installation InstructionsInstallation Instructions
HDU681 Labgear TV Distribution System
Modulator required if not built in to
Masthead Amplifier (optional)
Standard Sky
Sky+ 1
Sky+ 2
Satellite/No Satellite Switch -
Set to UHF & CCTV if there is no satellite connected to the system
SAT 2 Signal
(Sky+ )
PSW241, PSW132, PSW122 & PSW111 are available as both flush faceplates and screened modules. Individual Telephone and Return modules are also available.
Combined
Signal
SAT1
SAT2
FM/DAB RETURN
TV
SAT 2 (SKY+)
SAT1
SAT2
FM/DAB
TV
PSW241 - Suitable for
Sky+™ installations
with separate Return
& Phone sockets
TV FM/DAB Sky+™ Sky™ Return Phone PSW351T ✔ ✔ ✔ ✔ ✔ ✔ PSW241 ✔ ✔ ✔ ✔  PSW242T ✔ ✔ ✔ ✔ PSW132 ✔ ✔ ✔ PSW113  PSW122 ✔ ✔ PSW111
2
camera
Combined Signal
Return/Uplink
PSW351T
Suitable for Sky+™
installations
SAT
TV
FM/DAB RETURN
PSW242T
Suitable for Standard Sky™
installations
Suitable for combined
TV and Radio outlet
SAT
TV
FM/DAB
PSW132 - Suitable for
Standard Sky™
installations with separate
Return & Phone sockets
Remote Rooms
PSW122
TV
FM/DAB
RF2 OUT RF1 OUT
SAT
VCR/DVR
RF Lead
SCART
Lead
PSW111
Suitable for TV outlet
SCART
Lead
Power
Supply
Specifications
HDU641 HDU681 Number of Inputs 4 6 Number of Outputs 4 8 Gain to outputs ±7dB ±7dB Noise figure 4dB 4dB Gain/Loss to Downlink: FM 88-108MHz -4dB -4dB DAB 217-230MHz -5dB -5dB UHF 470-862MHz 2.5dB 2.5dB CCTV 470-862MHz -6.5dB -6.5dB SAT 1 950-2300MHz -1.5dB -1.5dB SAT 2 950-2300MHz -1.5dB -1.5dB
HDU641 HDU681 LNB rejection in UHF >40dB >40dB Uplink Gain 470-854MHz 8dB 8dB Return Path 3-10MHz 3-10MHz Return Path Gain 0dB 0dB All port IR enabled 9V/15mA LNB Line Power 20V/400mA UHF Line Power 12V/40mA f- connectors IEC 60169-24 Power requirements 230VAC~50Hz
250mA typical
3