On the serial number plate at back of the machine, you may find the unit's model number,
serial and reference number. Please double check the numbers and fill in the form with and
quote the reference number, when you are in contact with your distributors:
ModelSerial number
Reference number
* * Before operating the sterilizer, please read carefully all safety cautions and instructions for
operation. This operation manual will help you understand all functions of Runyes sterilizer
as far as possible.
Please follow carefully the instructions in this operation's manual while servicing and maint
aining the units.
* Please keep the manual safe for your future references.
* Should error occur during operation of the machine, please get in touch with your local
distributor, or us for your best qualified services and assistance.
Operation manual
Important information on Safety
SEA Series Steam Sterilizers
Stability
Smother!!!
Heaviness!!!
1.Please check the voltage according to the nameplate before plug the power cord, Don't use
electricaloutlets other than the correct voltage. Otherwise it might cause fire or electric shock.
2.Don't wet your hand before plugging or unplugging the power cord.
3.Don't place your sterilizer on an unstable table top, moving desk,tilted and shaking surface
4.Please don't cover or block the door, ventilation or radiation openings on the sterilizer.
5.Please don't put heavy stuff or liquid containers that might spill on the top of the machine.
6.Please unplug the power cord when the machine isn't used for a long while or when you
travel etc.
Runyes design and make pressurized steam autoclaves especially to meet the needs for sterilization of
instruments and devices in clinics,departments in a hospital and laboratories.
Operators include doctors or his/her assistance under doctors supervisions.The autoclave is computerized,
user friendly and easy to operate. Its real time display shows all data during the sterilization cycle. The
software program provides auto diagnose, protection against over heating or over pressurizing, and thus
ensures reliability of the sterilization results. Build- in condenser water collecting system prevents discharge
of waste steam and keeps the machine clean and safe.
YUN-22LYUN-17L Steam sterilizers
YUN uses the advanced technology of 1 time pre -vacuum and vacuum drying. It enables the hot steam
to penetrate in thin tube and porous material. This product is suitable for dentistry, ophthalmology, surgical
surgical instruments, dressing theatres and laboratories to sterilize dental and and other 135 autoclavable
stuffs.
Used water tank
Water tank
Door handle
Water tank connection
Used water tank connection
Fig 1-1
Power switch
Printer
Fuse
Operation manual
1
SEA Series Steam Sterilizers
2.Specifications
Chamber inner dimensions (Diameter x Depth)..............................................................22L:247mm x 450mm
17L:247mm x 355mm
Power supply
Sterilizing temperature /pressure
............................................................................134 / 2.02.3 Bar(Under standard atmospheric pressure
Cautions
Note: Temperature/Pressure here means the chamber temperature and pressure during the phase of sterilization.
The value varies under different atmospheric pressure.
.........................................................................................................according to the nameplate
..........................121 /(0.9 1.3Bar(Under standard atmospheric pressure
Tips Standard atmospheric pressure: It the atmospheric pressure at sea level. It refers to 1 Standard atmospheric
pressure. The value is 0.1Mpa=1000Hpa=1.0 Bar. Atmospheric pressure decreases by higher altitude. An increase
of altitude of 1000 mcters mill resuct in a decreace of ATM PR .of approximately BAF. decreases by about.
Fast / Down
Start
Water leakage
connection
Caution & Warning
B type device
Grounded correctly
Operation manual
2
SEA Series Steam Sterilizers
3.Installation
The Autoclave should be installed in a drafty place allowing minimum of 10 cm space at all sides and 20 cm
at the top. The ventilation openings at the side of the machine should not be blocked. The Autoclave should
be placed on a leveled counter top. The dimension of machine as the following figure:
440
460
585
585
440
Fig 3-1
Caution
If the front of the machine is lower than the back the control will display E3 (E3 means it does not
dry completely)
Operation manual
3
Preparation before using
We installed the draining filter before the device leaving factory.
(fig 3-2). Clean the draining filter once per month. You can see
the instructions of how to clean it according to page 12.
SEA Series Steam Sterilizers
Fig3-2
Before using the device, you should make electrical connections by
using the power cord that comes with the unit. Insert the hollowed
end of the power cord in to the inlet of the machine and plug the other
end on a power outlet. Caution: The power supply can afford 1800VA
load. Ok, you can turn on the autocalve now.
Fig3-3
Caution
The power supply must be can afford (22L) 2300W or (17L) 1800W.
Tips: Before starting the Autoclave, please check on the local atmospheric pressure. If the pressure is lower than 0.095 Mpa
or the Altitude is higher than 500 meters, you will need to contact your distributor who should reconfigure the controller in
the device.