Labconco 5530000 PerformixTM 160 A X-ray Tube Assembly Technical Reference Manual

Page 1
LABCONCO CORPORATION 8811 Prospect Ave, Kansas City, MO 64132
Description
Part Number
Door Latch
5530400
Sample Shelf
5533400
Valve Assembly
5535900
Support Stand
5529100
Desiccant Pan
5532100
Catalog Number
Description
Use
5535700
Vacuum Tubing Kit, includes 1/4" ID and 1/2" ID vacuum tubing, each 48" long; 2 each 1/4" and 1/2" tubing clamps; 1/4" to 1/2" barbed reducer.
Used to connect Desiccator Cabinet to vacuum pump.
5530600
Stacking Rack, epoxy-coated steel, glacier white in color
Provides for the stacking of two Desiccator Cabinets.
1
5 3 4
2
(816) 333-8811 or (800) 821-5525 • (816) 363-0130 fax • labconco.com
Vacuum Desiccator Cabinet Model No. 5530000
Replacement Parts
Accessories
Installation and Maintenance
Your Desiccator should be inspected thoroughly prior to usage. Any damage that may have occurred in transit should be reported immediately. The Desiccator should be located adjacent to a vacuum source, should it be required. Adequate counter space is required to facilitate the opening and closing of the door.
1. Place cabinet on the supplied support stand. Holes are provided in the cabinet to position the rack correctly.
2. Attach 1/4" ID vacuum hose to the fitting on the valve if vacuum is required for your specific application.
3. The cabinet may be used with or without vacuum grease on the door gasket surface. If a lower vacuum is anticipated over a long period of time, a light coating of grease is recommended.
4. Load the stainless steel pan that has been provided with a commercially available desiccant material.
5. Apply or release vacuum to the cabinet by opening or closing the vacuum valve.
The fiberglass-molded cabinet can be washed with detergent and warm water. DO NOT use harsh detergents or scouring powders on the fiberglass surfaces. The window is tempered safety glass and care should be taken to avoid scratching and/or damaging this surface.
1. The door gasket should be kept clean to assure a good seal. If vacuum grease is used on the gasket, it should be removed occasionally with a soft dry cloth and reapplied.
2. The Desiccator cabinet is shipped completely assembled. Should the door need adjustment, the following procedure should be followed:
a. With door closed and latched, loosen screws holding door hinges and latches to the cabinet body. b. If a vacuum source is available, apply any level of vacuum to cabinet. The vacuum will hold the door in
place and compress the gasket.
c. If vacuum source is not available, adjust the door such that the face of the glass compresses the gasket
slightly and retighten screws.
Labconco Instruction Sheet 5534600, Rev. J, ECO L427 1 of 2
Page 2
Copyright © 2018 Labconco Corporation. The information contained in this manual and the
Warranty
Labconco Corporation provides a warranty to the original buyer for the repair or replacement of parts and reasonable labor as a result of normal and proper use of the equipment with compatible chemicals. Broken glassware and maintenance items, such as filters, gaskets, light bulbs, finishes and lubrication are not warranted. Excluded from warranty are products with improper installation, erratic electrical or utility supply, unauthorized repair and products used with incompatible chemicals.
The warranty for Vacuum Desiccator Cabinets will expire one year from date of installation or two years from date of shipment from Labconco, whichever is sooner. Warranty is non-transferable and only applies to the owner (organization) of record.
Buyer is exclusively responsible for the set-up, installation, verification, decontamination or calibration of equipment. This limited warranty covers parts and labor, but not transportation and insurance charges. If the failure is determined to be covered under this warranty, the dealer or Labconco Corporation will authorize repair or replacement of all defective parts to restore the unit to operation. Repairs may be completed by 3rd party service agents approved by Labconco Corporation. Labconco Corporation reserves
the rights to limit this warranty based on a service agent’s travel, working hours, the site’s entry restrictions
and unobstructed access to serviceable components of the product. Under no circumstances shall Labconco Corporation be liable for indirect, consequential, or special
damages of any kind. This warranty is exclusive and in lieu of all other warranties whether oral, or implied.
accompanying products are copyrighted and all rights reserved by Labconco Corporation. Labconco Corporation reserves the right to make periodic design changes without obligation to notify any person or entity of such change.
Returned or Damaged Goods
Do not return goods without the prior authorization from Labconco. Unauthorized returns will not be accepted. If your shipment was damaged in transit, you must file a claim directly with the freight carrier. Labconco Corporation and its dealers are not responsible for shipping damages.
The United States Interstate Commerce Commission rules require that claims be filed with the delivery carrier within fifteen (15) days of delivery.
Limitation of Liability
The disposal and/or emission of substances used in connection with this equipment may be governed by various federal, state, or local regulations. All users of this equipment are required to become familiar with any regulations that apply in the user’s area concerning the dumping of waste materials in or upon water, land, or air and to comply with such regulations. Labconco Corporation is held harmless with respect to user’s compliance with such regulations.
Contacting Labconco Corporation
If you have questions that are not addressed in this manual, or if you need technical assistance, contact Labconco’s Customer Service Department or Labconco’s Product Service Department at 1-800-821-5525 or 1-816-333-8811, between the hours of 7:30 a.m. and 5:30 p.m., Central Standard Time.
Labconco Instruction Sheet 5534600, Rev. J, ECO L427 2 of 2
Loading...