Labconco 2127603 User Manual

User’s Manual
Two and Six-Place (Macro) Kjeldahl Distillation Systems
Models 2128501 2127601 2127602 2127603
complete your product registration card
online at register.labconco.com
Labconco Corporation 8811 Prospect Avenue Kansas City, MO 64132-2696 800-821-5525, 816-333-8811 FAX 816-363-0130 E-MAIL labconco@labconco.com HOME PAGE www.labconco.com
Please read the User’s Manual before operating the equipment.
Copyright © 2011, 2013 Labconco Corporation. All rights reserved.
The information contained in this manual and the accompanying products are copyrighted and all rights reserved by Labconco Corporation. Labconco Corporation reserves the right to make periodic design changes without obligation to notify any person or entity of such change.
Warranty
Labconco provides a warranty on all parts and factory workmanship. The warranty includes areas of defective material and workmanship, provided such defect results from normal and proper use of the equipment.
The warranty for all Labconco products will expire one year from date of installation or two years from date of shipment from Labconco, whichever is sooner, except the following;
Purifier® Logic® Biological Safety Cabinets and PuriCare® Lab Animal Research Stations
carry a three-year warranty from date of installation or four years from date of shipment from Labconco, whichever is sooner.
SteamScrubber® & FlaskScrubber® Glassware Washers carry a two-year warranty from date
of installation or three years from date of shipment from Labconco, whichever is sooner.
Blood Drawing Chairs carry a ten year warranty.
Carts carry a lifetime warranty.
Glassware is not warranted from breakage when dropped or mishandled.
This limited warranty covers parts and labor, but not transportation and insurance charges. In the event of a warranty claim, contact Labconco Corporation or the dealer who sold you the product. If the cause is determined to be a manufacturing fault, the dealer or Labconco Corporation will repair or replace all defective parts to restore the unit to operation. Under no circumstances shall Labconco Corporation be liable for indirect, consequential, or special damages of any kind. This statement may be altered by a specific published amendment. No individual has authorization to alter the provisions of this warranty policy or its amendments. Lamps and filters are not covered by this warranty. Damage due to corrosion or accidental breakage is not covered.
Returned or Damaged Goods
Do not return goods without the prior authorization from Labconco. Unauthorized returns will not be accepted. If your shipment was damaged in transit, you must file a claim directly with the freight carrier. Labconco Corporation and its dealers are not responsible for shipping damages.
The United States Interstate Commerce Commission rules require that claims be filed with the delivery carrier within fifteen (15) days of delivery.
Limitation of Liability
The disposal and/or emission of substances used in connection with this equipment may be governed by various federal, state, or local regulations. All users of this equipment are required to become familiar with any regulations that apply in the user’s area concerning the dumping of waste materials in or upon water, land, or air and to comply with such regulations. Labconco Corporation is held harmless with respect to user’s compliance with such regulations.
Contacting Labconco Corporation
If you have questions that are not addressed in this manual, or if you need technical assistance, contact Labconco’s Customer Service Department or Labconco’s Product Service Department at 1-800-821­5525 or 1-816-333-8811, between the hours of 7:00 a.m. and 6:00 p.m., Central Standard Time.
Part # 2081402, Rev. A
ECO H435
T
AABBLLEE
T
CHAPTER 1: INTRODUCTION 1 Components Shipped 1 General Description 2 Performance 3 Component Identification 3
CHAPTER 2: INSTALLATION 5 General Installation Notes 5 Location 5 Electrical 6 Tap Water Supply 7 Distillation Manifold 7 Glassware Installation 8
CHAPTER 3: NORMAL OPERATION & ROUTINE
Normal Operation Start-Up 9 Clean-Up and Cosmetic Guidelines 10
APPENDIX A: REPLACEMENT PARTS 11
APPENDIX B: DIMENSIONS & AIRFLOW REQUIREMENTS 13
APPENDIX C: TOTAL KJELDAHL NITROGEN METHOD 14
O
O
MAINTENANCE 9
FF
C
C
OONNTTEENNTTSS
CChhaapptteerr 11:: IInnttrroodduuccttiioonn
Components Shipped
Carefully check the contents of your Two-Place or Six-Place Kjeldahl Distillation System for shipping damage while it is still on the shipping pallet. Do not discard the packaging material until the contents have been checked and the equipment has been approved for installation.
The Two-Place or Six-Place Kjeldahl Nitrogen Distillation System has been shipped in one complete crate to minimize damage that may occur in transit.
Make sure to inspect the product thoroughly prior to installation and report any damage that may have occurred in transit (see Warranty page for instructions).
Product Service 1-800-522-7658
1
Chapter 1: Introduction
General Description
Labconco’s Two and Six-Place (Macro) Kjeldahl Distillation Systems are designed to facilitate the determination of Total Nitrogen content within materials such as feeds, grains, soils, fertilizers, plant tissue, water, organic wastes, and food products. The expression Macro identifies the size of sample vessel and the sample size that can be used with this equipment. Other Kjeldahl systems are available, which use smaller sample vessels and require smaller sample sizes. This apparatus can be used for the distillation of all types of nitrogen containing samples. The Two and Six-place Distillation Systems can be used to perform a standardized Macro-Kjeldahl Nitrogen Determination Method.
The Kjeldahl Distillation Systems are not enclosed, excess heat and personnel safety during the distillation reaction must be considered when selecting an installation location. The Kjeldahl Distillation Method is a ‘Closed Distillation,’ no chemical fumes are released during the procedure. The Distillation procedure does involve boiling concentrated sodium hydroxide at high temperatures. Labconco recommends placing Two and Six-Place Distillation Systems inside a chemical fume hood for safety. Labconco recommends a splash shield be placed in front of the Distillation Systems if they are installed on the open lab bench.
2128501 & 2127601 Two-Place and Six-Place Kjeldahl Distillation Systems
2
Product Service 1-800-522-7658
Chapter 1: Introduction
Performance
The Two and Six-Place Kjeldahl Distillation Systems have been designed for use in the determination of nitrogen (or ammonia) concentrations. By calculation, nitrogen can be converted to protein values for products such as plant tissues, meats and other food substances. Nitrogen determinations with the (Macro) Distillation Systems can accommodate sample sizes up to 300­400 mls, due to the size of the distillation flasks. Detailed procedures developed by professional laboratory organizations such as American Association of Analytical Chemists (AOAC) and American Association of Cereal Chemists (AACC) should always be consulted for step by step analytical procedures when operating this equipment. For methodology precision and accuracy please consult the specific published method for the type of sample or substance that will be analyzed.
Component Identification
1. Electric Heaters. 600-watt heaters are used in the distillation rack of the
units. Infinite control switches regulate each of the heaters. The curved heater elements are provided and allow for the round base of the Kjeldahl flasks, providing faster and more evenly distributed heat. All heaters and temperature controllers are wired to a common subpanel electrical box, for easy electrical connection to a facility electrical circuit.
2. Temperature Gauge. The condensation rack behind the distillation
heating elements requires cooling water. The temperature of the distillation cooling water on the Six-Place Distillation System can be adjusted to promote condensation and suit individual requirements with the flow control valve handle, located below the distillation heaters. Water temperature is indicated on the thermometer, which is located at the water outlet of the distillation manifold. The Two-Place Distillation Systems does not feature a flow control valve or temperature gauge. The cooling water connections are 3/4" NPT and the supply line should be 1/2" minimum for proper water flow through the unit. For facilities where the ground water temperature exceeds 80°F, a recirculation water chiller system will be required to achieve sufficient condensation results.
3. Distillation Condensation Manifold. Epoxy coated steel outer columns
with stainless steel inner condensation columns provide long life.
Product Service 1-800-522-7658
3
3
Chapter 1: Introduction
2
1
4
Product Service 1-800-522-7658