L-3Com 9040-T Specifications

Page 1
Baseband to Baseband
IF to Baseband
Baseband to IF
IF to IF
Model 9040-T(A)
Versatile Frequency Converter
FEATURES
Variable Input Tuning Range
10 kHz to 400 MHz
200 MHz Bandwidth Available for
Input IF Fixed Frequencies of
.455/.85/1.7/6.8/8.83/10.7/13.6/21.4/
27.2/70/140/160/300/400 and 1000 MHz
Variable Output Tuning Range of
10 kHz to 400 MHz
Output Fixed Frequencies of
3/6/10/15/20/21.4/25/30/40/50/70140/ 160/300/400 MHz
Thirteen Standard Band
widths of 1/2/4/6/8/10/12/20/30/40/ 50/60/80 MHz and a Bypass Mode
Nine Selectable Output equalizers
Centered at 3/6/10/15/20/25/ 30/40 and 50 MHz
Coherent Frequency Conversion
Synthesized Tuning 1 kHz
Increments
Imageless Mixers and Saw Filters
Utilized
PRODUCT DESCRIPTION
The Model 9040-T(A) is a synthesized frequency converter that is tunable on both the input and output in 1 kHz steps. The excellent performance characteristics of the imageless mixers make the wide tuning range possible while controlling spurious signals and maintaining tight amplitude requirements. Distortion due to group delay variations is minimized by the use of multi-section group delay equalizers. Any specifi ed input can be converted to any specifi ed output and the unit functions as an upconverter or downconverter per the selected parameters. Each unit has IF to IF, IF to Baseband, Baseband to IF and Baseband to Baseband capabilities.
The unit has the capability to convert any input frequency in the range of 10 KHz to 400 MHz including fi xed IF frequencies of .455/.85/1.7/6.8/8.83/
10.7/13.6/21.4/27.2/70/140/160/300/400 and 1000 MHz, to any output frequency in the range of 10 kHz to 400 MHz including fi xed IF output frequencies of 3/6/10/15/20/21.4/25/30/40/50/70/140/160/300 and 400 MHz. Imageless mixers are used for conversions of frequencies up to the 120 MHz band edge. The image rejecting mixers are employed to suppress undesired mixer products and to improve the signal to noise ratio by suppression of the image band. Group delay equalizers are provided for Output Center Frequencies of 3/6/10/15/20/25/30/40 and 50 MHz in the standard 9040-T(A).
In addition to the up/down conversion capability, it can also function as a selectable fi lter with up to thirteen bandwidths plus a bypass mode. The standard 9040-T(A) contains 1/2/4/6/8/10/12/20/30/40/50/60/80 fi lters and a Bypass mode. The Bypass mode is furnished to allow extra fl exibility in situations where image rejection of 35 dB is acceptable. The signal bandwidths are determined by the selected IF fi lter. Bandwidths of ±100% of any center frequency in the tunable range can also be selected but are limited by the bandedges of each band range. When an input IF is selected, optimum performance will occur when a bandwidth that is less than the IF center frequency is selected. A built-in indicator alerts the operator when the center frequency selected is less than 1/2 the SAW fi lter’s 40 dB bandwidth. The maximum bandwidth for the 1 GHz input CF is 200 MHz. The maximum bandwidth for any other mode of operation is 80 MHz.
www.L-3Com.com/COMINT
Page 2
SPECIFICATIONS
Model 9040-T (A)
Versatile Frequency Converter
Quadruple Conversion is used, and the tunable synthesizers and the local oscillator are phase locked to the reference oscillator, which may be either the internal reference or an external reference provided by the user. The synthesizer allows selection in 1 kHz increments, providing excellent resolution for centering the output band. The converted signal is upright and non-inverted. The integrity of the converted data is protected by means of the SAW fi lters that exhibit excellent group delay characteristics.
Several modes for frequency and bandwidth selection are available including key pad entry, Up/Down arrow key selection and a tuning knob for rapid tuning, as well as full IEEE-488 control capability. Both Input Frequency and Output Frequency as well as Bandwidth are displayed on front panel read outs. A meter is provided to display input signal level. Automatic and manual gain control is furnished with the gain mode indicator on the front panel. IEEE-488 control is by means of logical and easy to use Mnemonics, which directly and simply specify the desired function. Internal software routines perform and implement all calculations to set up the synthesizers and illegal or inconsistent combinations are rejected. The 9040-T(A) is housed in a standard 19” wide EIA housing. EMI/RFI integrity is assured by the design which includes gaskets, solid coaxial cables and a machined housing for critical sub-assemblies. The power line is isolated by multi-section EMI/RFI fi lters to further assure satisfactory performance in any environment.
Number of Channels One
Input Tuning Range (Variable) 10 kHz to 400 MHz
(10 kHz to 120 MHz) Imageless Mixers
Input Fixed Frequency .455/.85/1.7/6.8/8.83/10.7/13.6/21.4/27.2/70/140/160/300/ 400/1000 MHz
Output Tuning Range (Variable) 10 kHz to 400 MHz (10 kHz to 120 MHz) Non-Imageless Mixers
Output Fixed Frequency 3/6/10/15/20/21.4/25/30/40/50/70/140/160/300/400 MHz *NOTE: All common IF frequencies such as 455 kHz, 21.4 MHz, 10.7 MHz,
70 MHz and 160 MHz can be selected on the input or the output as can any of the FDM group, super group or master group frequencies. Entire TDM bands or other signals with bandwidths up to 100 MHz can be processed.
Tuning Resolution 1 kHz
Incremental Tuning Step Size Programmable for any 1 kHz resolution increment.
Selectable Bandwidths Up to thirteen bandwidths selectable bandwidths are available per
unit -1/2/4/6/8/10/12/20/30/40/50/60/80 MHz and Bypass are provided in the standard 9040-T(A).
Input/Output Bandwidth +100/-97% of center frequency. (Imageless Mode) Not to exceed 100 MHz or the band edges of 10 kHz to 120 MHz
Selectable Group Delay Equalizers Nine group Delay OUTPUT Equalizers of 3/6/10/15/20/25/30/40/50
MHz center frequencies are provided in the standard 9040-T(A). These group delay equalizers are in the output baseband section.
Group Delay Variations Over ±75% of Output Center Frequency Output CF Group Delay 3 MHz ± 35 nanoseconds 6 MHz ± 16 nanoseconds 10 MHz ± 10 nanoseconds 15 MHz ± 8 nanoseconds 20 MHz ± 5 nanoseconds 25 MHz ± 4 nanoseconds 30 MHz ± 3.1 nanoseconds 40 MHz ± 4.2 nanoseconds
50 MHz ± 5 nanoseconds *NOTE: The Group Delay specifi cations above are valid when unit is in the Output
TDE Mode and with NO SAW Filters or Imageless upconverters selected.
Anti-aliasing In the time-delay equalizer mode, anti-aliasing is available from both the band pass fi lters and from a multi-section eliptical function low pass fi lter that is an integral part of the time delay equalizer. When the time delay equalizers are not in use, the anti-aliasing is derived from the bandpass fi lters.
Amplitude Variation Less than ±1.5 dB over 75% Bandwidth for 3/6/10/15/20 MHz C.F. Less than ±2 dB over 75% Bandwidth for 25/30/40 MHz C.F. Less than ±2.2 dB over 75% Bandwidth for 50 MHz C.F.
Input Level (IF Frequencies) -56 dBm to +4 dBm
Output Level -30 dBm to +4 dBm
MGC Range 60 dB Minimum
AGC Range 60 dB Minimum
AGC Output Stability Less than ±1.0 dB output level change over the specifi ed input
signal range
Page 3
SPECIFICATIONS
Model 9040-T (A)
Versatile Frequency Converter
Image Rejection/Undesired Mixer Product Rejection Employs imageless mixers and SAW fi lters yielding rejection performance that is confi guration dependent. Typical measured
rejection is 35 dB from the imageless mixers and at least 40 dB from the SAW Filters giving a total 75 dB rejection outside the 40 dB IF shape factors listed below.
Typical Filter Performance
BW 3 dB BW 3 dB BW 1 dB BW 40 dB GD VAR Min (MHz) Typ (MHz) Min (MHz) Max (MHz) ± nsec
1 1.04 0.77 2.2 50 2 2.071 1.65 3.9 23 4 4.217 3.7 6.0 23 6 6.3 5.6 8.4 25 8 8.18 7.3 10.6 36 10 10.35 9.3 13.0 30 12 12.2 11.1 15.0 18 20 20.4 18.8 25.0 10 30 32.2 29.7 40.0 8 40 40.1 37.0 50.0 6 50 56.5 47.5 73.0 5 60 64.7 60.0 81.0 5 80 81.7 64.0 113.0* 6
*Measured at 30 dB Bandwidth
Frequency Stability Internal ± 25 ppm
Phase Noise Less than 2 degrees RMS for 0.5 to 20 kHz Offset
Impedance - All Signal Ports 50 ohms
VSWR Input 1.5:1
Output 2.0:1
Total Harmonic Distortion Less than 2% with tone 6 dB below nominal output level
Two-tone Intermodulation Products Greater than -40 dBc with each tone 6 dB below nominal output level
Spurious Output 50 dB down
LO Rejection 50 dB down typical when input CF is ≥ 40 dB BW ÷ 2 (Input Alert Light OFF)
External Reference Frequency Input Frequency 10 MHz
Input Level 0.5 Vms to 5.0 Vms Input Impedenance 50 Ohms VSWR 2.0:1
Connectors Signal Port connectors (all) BNC External Reference Connector BNC Control Connector IEEE-488 Standard (metal shell)
Controls: Local/Remote (1) Input Frequency (Tunable and Fixed Random Access) (2) Output Frequency (Tunable and Fixed Random Access) (3) Incremental Frequency Selection via UP/Down Arrow Keys (4) Bandwidth and Bypass (5) Imageless Mode (6) AGC/MGC (7) Input/Output Attenuation (8) Local/Remote Operation (9) Local Lockout* (10) Explicit Time Delay Equalizer Selection (Remote Only) (11) AC Power *Local lockout can be disabled from a rear panel switch that will ignore a local lockout from a remote user. If the local lockout function is disabled from the rear
panel, pressing the local selection switch will ALWAYS cause the unit to return to local operation.
Page 4
SPECIFICATIONS
Model 9040-T (A)
Versatile Frequency Converter
Indicators (Red LED) (1) Input Center Frequency Display (2) Output Center Frequency Display (3) “Alert” Indicator to indicate excessive Bandwidth selection (4) Selected Bandwidth Display (5) AGC/MGC (6) LOCAL/REMOTE/LOCKOUT (7) Incremental Tuning Steps (8) EXTERNAL REFERENCE IN USE (9) LO UNLOCK (10) Input Attenuation level in MGC Mode (11) Input overload (12) AGC level is displayed on a 20-segment front panel bargraph when in AGC mode. The level driving this meter is converted and made available to the IEEE-488 bus. In the MGC mode, this meter indicates the relative level of input attenuation. (13) Output Attenuation is displayed on two 7-segment displays. The information is also available over the IEEE-488 bus. (14) Imageless (15) Tuning Knob Disable (16) Power On NOTES:
1. Subsequent to loss of power, converter returns to Local control mode and restores all settings that were in effect at the time of power failure.
2. Under Remote control mode of operation, all local control functions are disabled except AC power switch and local selection switch
Dimensions 7.0” x 19” x 22” (HWD)
Weight 55 lbs. (approximate)
Environmental Storage Temperature 0° to +50° C
Relative Humidity 0 to 95% non-condensing
Environmental Operating Temperature 0° to +50° C Relative Humidity 0 to 95% non-condensing
Power 90-264 VAC, Autoranging 47-440 Hz 150 Watts
For Additional Information Contact:
L-3 Communication Systems-East One Federal Street, Camden, NJ 08103 Telephone: 856-338-INFO Fax: 856-338-2550 E-mail: logen.thiran@L-3Com.com or Visit our Website at: http://www.L-3Com.com/COMINT
Cleared by DoD/DFOISR for Public Release under DFOISR case number 04-S-0865 on March 18, 2004
All Data and Specifi cations Subject to Change
COM9040TA-01/04