Küppersbusch KD 9550 Instruction Booklet

KD 9550KD 9550
KD 9550KD 9550
KD 9550
Bedienungsanleitung Instructions Booklet Mode d’emploi Libretto Istruzioni Gebruiksaanwijzing Manual de instrucciones Manual de instruções
NL
IT
FR
GB
DE
ES PT
12GB
CONTENTS
Dear Customer,
If you follow the recommendations contained in this Instruction Manual, your appliance will give you constant high performance and will remain efficient for many years to come.
RECOMMENDA TIONS AND SUGGESTIONS 13 CHARACTERISTICS 14 INSTALLATION 15 USE 17 MAINTENANCE 18
13GB
RECOMMENDATIONS AND SUGGESTIONS
INSTALLATION
• The manufacturer will not be held liable for any damages resulting from incorrect or improper installation.
• Check that the mains voltage corresponds to that indicated on the rating plate fixed to the inside of the hood.
• For Class I appliances, check that the domestic power supply guarantees adequate earthing. Connect the extractor to the exhaust flue through a pipe of minimum diameter 120 mm. The route of the flue must be as short as possible.
• Do not connect the extractor hood to exhaust ducts carrying combustion fumes (boilers, fireplaces, etc.).
• If the extractor is used in conjunction with non-electrical appliances (e.g. gas burning appliances), a sufficient degree of aeration must be guaranteed in the room in order to prevent the backflow of exhaust gas. The kitchen must have an opening communicating directly with the open air in order to guarantee the entry of clean air.
USE
• The extractor hood has been designed exclusively for domestic use to eliminate kitchen smells.
• Never use the hood for purposes other than for which it has ben designed.
• Never leave high naked flames under the hood when it is in operation.
• Adjust the flame intensity to direct it onto the bottom of the pan only, making sure that it does not engulf the sides.
• Deep fat fryers must be continuously monitored during use: overheated oil can burst into flames.
• The hood should not be used by children or persons not instructed in its correct use.
MAINTENANCE
• Switch off or unplug the appliance from the mains supply before carrying out any maintenance work.
• Clean and/or replace the Filters after the specified time period.
• Clean the hood using a damp cloth and a neutral liquid detergent.
14GB
CHARACTERISTICS
Dimensions
Components
Ref. Q.ty Product Components 1 1 Hood Body, complete with: Controls, Light,
Blower, Filters
8 1 Directional Air Outlet grille 16 1 Filter cover
Ref. Q.ty Installation Components 11 2 Wall Plugs 11a 2 Wall Plugs SB 12/10 12a 2 Screws 4,2 x 44,4 12c 4 Screws 2,9 x 6,5 12d 2 Screws 2,9 x 9,5
Q.ty Documentation
1 Instruction Manual
1
16
12c
11
12a
12d
8
11a
15GB
INSTALLATION
Wall drilling and bracket fixing
On the wall, draw
• a Vertical line up to the ceiling or upper limit, at the centre of the area in which the Hood is to be fitted;
• a Horizontal line at a minimum of 960 mm above the Cooker Top.
• Mark a point (1) on the horizontal line, 200 mm to the right of the vertical reference line.
• Repeat this operation on the other side, checking that the two marks are level.
• Mark a reference point (2) as indicated at 180 mm from the vertical reference line and 362 mm above the Cooker Top.
• Repeat this operation on the other side, checking that the two marks are level.
• Drill at the points (1) marked, using a ø 12 mm drill bit.
• Drill at the points (2) marked, using a ø 8 mm drill bit.
• Insert the bracket plugs 11a into the holes 1 and screw into place.
• Insert plugs 11 into holes 2.
11a
11
11
12a
22
180
200 200
960
362
180
250
16GB
16
12c
12d
8
Mounting the hood body
• Open the ducting panels.
• Disconnect the panel from the hood canopy by sliding the fixing pin lever.(A)
• Remove the metal grease filters by turning the handles provided.
• Adjust the two screws Vr, on brackets 11a, to a minimum.(B)
• Hook the hood canopy onto the two brackets
11a.
• From inside the hood canopy, adjust the screws Vr to set the Hood Canopy level.
• Tighten the safety screw 12a.
Connections
DUCTED VERSION AIR EXHAUST SYSTEM
To install the Ducting Version of the hood, the optional Ducting chimney kit must be purchased.
RECIRCULA TION VERSION AIR OUTLET
To install the Recirculation Version of the hood, the optional Activated charcoal cartridge kit must be purchased.
• Screw the filter cover onto the air outlet, using four screws 12c (2.9 x 12.5).
• Fix the directional grille 8 on the recirculation air outlet using the 2 screws 12d (2,9 x 9,5) provided.
ELECTRICAL CONNECTION
• Connect the hood to the mains through a two-pole switch having a contact gap of at least 3 mm.
• Remove the grease filters (see paragraph Maintenance) being sure that the connector of the feeding cable is correctly inserted in the socket placed on the side of the fan
(A)
(B)
Vr
17GB
L
S1
T1
T2
T3
T4
USE
Control Panel
The hood can be switched on pushing directly onto the requested speed without firstly having to select 0/1 button.
KEY LED FUNCTIONS L 0/1 Light Turns lighting on and off. T1 0/1 Motor on First speed.
When pressed for about 1 seconds the motor is switched off.
Flashing 24h Changeover
This is enabled by pressing and holding the button for approximately 5". It allows a suction level of 100 m3/h with a noise level of just 28dB(A). Can be enabled at any speed, even with the hood turned off. To disable, press and hold the button for approximately 5".
T2 Speed on Second speed.
Flashing Delay (30')
Press the button for approximately 2" to enable automatic shutdown with a 30' delay. Suitable to complete elimination of any residual smells. Can be enabled at any speed and is disabled by pressing the button briefly.
T3 Speed on Third speed. T4 Speed Fixed Max. speed
Flashing Intensive speed.
Suitable for the strongest cooking vapours and odours. The function becomes active when the button is pushed for about 2 seconds. After 10 minutes of functioning it turns off automatically. This function can be interrupted by means of pressing any of the buttons.
S1 Led Fixed Indicates that the Metal grease filters saturation alarm has
been triggered, and the filters need to be washed. The alarm is triggered after 100 working hours. (Reset; check the
Maintenance-paragraph)
Flashing indicates that the activated charcoal odour filter saturation
alarm has been triggered, and the filter has to be replaced; the metal grease filters must also be washed. The activated charcoal odour filter is triggered after 200 working hours.
(Activation and Reset; check the Maintenance-paragraph)
18GB
REMOTE CONTROL (OPTIONAL)
The appliance can be controlled using a remote control powered by a 1.5 V carbon-zinc alkaline batteries of the standard LR03-AAA type.
• Do not place the remote control near to heat sources.
• Used batteries must be disposed of in the proper manner.
MAINTENANCE
Grease filters
CLEANING METAL SELF- SUPPORTING GREASE FILTERS
Alarm signal reset
• Switch off the lights and extractor motor.
• Press button T3 for at least 3 seconds, until the leds start to flash.
Cleaning the filters
• The filters are washable and must be cleaned when led S1 flashes or at least every 2 months of opera­tion, or more frequently for particularly heavy us­age.
• Remove the filters one at a time by pushing them towards the back of the group and pulling down at the same time.
• Wash the filters, taking care not to bend them. Allow them to dry before refitting.
• When refitting the filters, make sure that the handle is visible on the outside.
Ducting panels
• Open the ducting panels.
• Disconnect the panel from the hood canopy by sliding the fixing pin lever.
• Clean the outside using a damp cloth and neutral liquid detergent.
• Clean the inside using a damp cloth and neutral detergent; do not use wet cloths or sponges, or jets of water; do not use abrasive substances.
19GB
A
B
Activated charcoal filter (Recirculation version)
REPLACING THE ACTIVATED CHARCOAL FILTER
• The filter is not washable and cannot be regenerated. It must be replaced when led S1 flashes or at least every 4 months. The alarm signal will only light up when the extractor motor is switched on.
Alarm signal reset
• Switch off the lights and extractor motor.
• Press button T3 for at least 3 seconds, until the leds start to flash.
Replacing the Filter
• Remove the metal grease filters
• Remove the saturated activated carbon filters as shown (A).
• Fit the new filters (B).
• Replace the metal grease filters.
Alarm signal activation
• In Recirculation version Hoods, the Filter saturation alarm can be enabled on installation or at a later date. Turn the Lights and the suction Motor off.
• Disconnect the Hood using the Main switch or the double-pole switch on the mains power supply.
• Restore the connection by pressing and holding T1.
• Release the button. All five LEDs are turned on
• Within 3 seconds press T1 until LEDs T1 and T4 flash in confirmation: LED flashes twice - Activated charcoal filter saturation alarm ENABLED LED flashes once - Activated charcoal filter saturation alarm DISABLED
Lighting
LIGHT REPLACEMENT
20 W halogen light.
• Remove the light cover by unfastening the screws that hold it.
• Extract the lamp from the Support.
• Replace with another of the same type, making sure that the two pins are properly inserted in the lamp holder socket holes.
• Replace the light cover.
Loading...