1. Synopsis
2. Product Image
3. Block Diagram
4. Specification
DR – A232
서식 QP-041-06R(0) ㈜경우시스테크 A4(210x297)
Name of document(문서명) Version(이력) Page
Engineering ■ Report □ Notice
Subject(제목) Reg. No(문서번호)
3 / 6
1. Synopsis
This document is specifically-written manual for receiver and transmitter (SMART KEY TAG) of wireless communication, which is to confirm user identifications under engine-start limiting function in heavy equipments.
SMART KEY TAG is defined as following: it receives signals with RFID 125 KHz and wakes up. After then, it transmits password-secured information to SMART KEY READER by using 2.4 GHz Zigbee wireless signals..
2. Product Image
1) External Appea rance
A232 User ’s Manual
WARNNIG
Exchanging batteries in incorrect way, It may cause explosion
Discard used batteries according to manufacturer’s instructions
DR – A232
2) Dimension
서식 QP-041-06R(0) ㈜경우시스테크 A4(210x297)
Certification LABEL location (Size 21mm X 15mm)
Name of document(문서명) Version(이력) Page
Engineering ■ Report □ Notice
Subject(제목) Reg. No(문서번호)
4 / 6
A232 User ’s Manual
3. Block Diagram
DR – A232
4. Specification
4.1. Operating Specification
-. Must wake up the remote control by providing electricity with RFID 125 KHz.
-. Must be operating with CR2032 battery.
-. Must be able to transfer password-secured signals.
-. Must be able to use all 16 channels with Zigbee band of 2405 to 2480MHz.
4.2. Power Specification
-. 3 V d.c. (CR 2032 Lithium Battery)
-. Notice : Inserting opposite polarity of battery may cause explosion or damage to product (Please match battery polarity with battery holder)
4.3. General S pecification
-. Storage Temperature: -20 ~ 70
-. Operating Temperature: -10 ~ 60
-. Water-Proof Specification: IP54 (Living Water-Proof)
-. Material of Device: PC (Flame Class: V2, Manufacturer : SABIC Innovative Plastics)
서식 QP-041-06R(0) ㈜경우시스테크 A4(210x297)
Name of document(문서명) Version(이력) Page
Engineering ■ Report □ Notice
Subject(제목) Reg. No(문서번호)
5 / 6
object/part No.
SMK TAG B/D PCB
4.4. RF Specification
Wireless Data
Communication
A232 User ’s Manual
-. PCB material
manufacturer/
trademark
WOOMYUNG ELEC
CO
System
DR – A232
type/model technical data standard
SKD V-0 ; 105 °C UL 796 UL
Item Specification
Operating Frequency
RF Power
Modulation Method
Tested Temperature
2405 ~ 2480MHz (16 Channals)
Under 10mW
QQPSK
-20 ~ 50
mark(s) of
conformity1)
FCC Compliance Statement
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Caution: Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
To comply with RF exposure compliance requirements, the antenna used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
서식 QP-041-06R(0) ㈜경우시스테크 A4(210x297)
Name of document(문서명) Version(이력) Page
Engineering ■ Report □ Notice
Subject(제목) Reg. No(문서번호)
6 / 6
A232 User ’s Manual
DR – A232
서식 QP-041-06R(0) ㈜경우시스테크 A4(210x297)