
Distributed(배포처)
식 QP-041-06R(0) ㈜경우시스테크 A4(210x297)
Name of document(문서명) Reg. No(문서번호)
Page
Engineering ■ Report □ Notice
DR-A230 1 /
Subject(제목) Version(이력) Date(작성일)
A230 User’s Manual
Rev 2009.10.28
Part No(품번) Name of Product(제품명) Prepared(작성) Reviewed(검토) Approved(승인)
A230 SMART KEY READER JJI -
<Revision History>
Rev Date Page Before Change After Change
Composi
-tion
Approval
2009.10.28 First Release

Name of document(문서명) Version(이력) Page
Engineering ■ Report □ Notice
2 / ^
Subject(제목) Reg. No(문서번호)
A230 User’s Manual
DR – A230
<Contents>
Revision History
1. Synopsis (general)
2. Product Image
3. Block Diagram
4. Specification
서식 QP-041-06R(0) ㈜경우시스테크 A4(210x297)

Name of document(문서명) Version(이력) Page
Engineering ■ Report □ Notice
3 / ^
Subject(제목) Reg. No(문서번호)
A230 User’s Manual
DR – A230
1. Synopsis
This document is specifically-written manual for SMART KEY READER which is receiver and
transmitter of wireless communication, which is to confirm user identifications under engine-start
limiting function in heavy equipments.
SMART KEY READER is defined as followings; SMART KEY READER transmits a signal pattern
by RFID 125 KHz in order to wake up SMK TAG. And then SMART KEY READER communicates
with SMK TAG by 2.4 GHz Zigbee wireless signal. SMART KEY READER decodes passwordsecured signals and transfer identification information to certification device which has a function of
engine-start limiting, such as Cluster, MCU or ECU, with using CAN protocol
2. Product Image
1) External Appearan ce
2) Dimension
서식 QP-041-06R(0) ㈜경우시스테크 A4(210x297)

Name of document(문서명) Version(이력) Page
Engineering ■ Report □ Notice
4 / ^
Subject(제목) Reg. No(문서번호)
A230 User’s Manual
DR – A230
3. Block Diagram
4. Specification
4.1. Operating S pecification
-. Must transmit a signal of RFID 125 KHz as a wake up pattern signal.
-. Must be activated from 12 Vdc/24 Vdc external voltage supply.
-. Must be able to analyze the password-secured signal.
-. Must have Zigbee band of 2400 to 2483.5MHz.
서식 QP-041-06R(0) ㈜경우시스테크 A4(210x297)

Name of document(문서명) Version(이력) Page
Engineering ■ Report □ Notice
5 / ^
Subject(제목) Reg. No(문서번호)
A230 User’s Manual
DR – A230
4.2. Power Specification
-. Rated Voltage: 12V(Max 30mA) / 24V (Max 20mA) both available
4.3. General Specification
-. Storage Temperature: -40℃ ~ 85℃
-. Operating Temperature: -30℃ ~ 75℃
-. Water-Proof Specification: IP00
-. Communication with equipment: CA N2.0 250Kbps (*It is reco mmended to use twist sh ield
cable and should be connected through a short distance as possible.)
-. Material of Device: PC
(Substance : 943AR, Flame Class : V0, Manufacturer : SABIC Innovative Plastics)
-. PCB Material
object/part No.
manufacturer/
trademark
type/model technical data standard
mark(s) of
conformity1)
SMK READER
B/D PCB
WOOMYUNG ELEC
CO
SKD V-0 ; 105 °C UL 796 UL
SMK READER
POWER B/D
PCB
JAE IN CIRCUIT CO
LTD
JID1 V-0 ; 130 °C UL796
4.4 RF Specification
Item Specification
Wireless Data
Communication
System
Frequency
2405 ~ 2480MHz (16 Channels)
RF Power
Under 10mW
Modulation Method
QQPSK
Tested Temperature
-20 ~ 50℃
Magnetic
Induction
System
Frequency
125KHz (Single Channel)
RF Power
Under 42
dBμA/m
@ 10 meter
Modulation Method
ASK
서식 QP-041-06R(0) ㈜경우시스테크 A4(210x297)

서식 QP-041-06R(0) ㈜경우시스테크 A4(210x297)
Name of document(문서명) Version(이력) Page
Engineering ■ Report □ Notice
6 / ^
Subject(제목) Reg. No(문서번호)
A230 User’s Manual
DR – A230

서식 QP-041-06R(0) ㈜경우시스테크 A4(210x297)
Name of document(문서명) Version(이력) Page
Engineering ■ Report □ Notice
7 / 7
Subject(제목) Reg. No(문서번호)
A230 User’s Manual
DR – A230
FCC Compliance Statement
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and, if
not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is likely
to cause harmful interference in which case the user will be required to correct the interference
at his own expense.
Caution: Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
To comply with RF exposure compliance requirements, the antenna used for this transmitter
must not be co-located or operating in conjunction with any other antenna or transmitter.