Kyoritsu Electrical Instruments Works, Ltd. KEW 6305 Quick Manual

Quick Manual
DIGITAL POWER METER
KEW 6305
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
KEW6305Preface
CD-ROM. This manual is intended only as a handy reference guide and should only be used after having read the full instruction manual which contains full details on each function of this instrument and the items contained in the package.
Precautions
  The instruction manual (full manual) contains warnings and safety procedures which have to be
observed to ensure safe operation of the instrument and maintain it in a safe condition. Thus, these operating instructions have to be read prior to using the instrument.
Contents
1. Instrument Overview ······························································································································2
2. Instrument Layout ··································································································································4
3. Preparations ··········································································································································· 7
4. Set-up:
5. Measurement Ranges ·························································································································13
6. Instantaneous value Measurement:
7. Integration value Measurement:
8. Demand Measurement:
9. SD card/ Saved data ··························································································································24
10. Wiring check:
11. Data check:
Range ······················································································································ 9
SET UP
Range···············································································14
W
Wh
Range ···················································································18
DEMAND
WIRING CHECK
DATA CHECK
Range ·······················································································21
Range··························································································27
Range ···································································································29
1
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
KEW6305
KEW6305 Instrument Overview
1. Instrument Overview
Features
This is a digital Power meter that can be used for various wiring systems and can measure up to 3 systems on single-phase 2-wire circuit. That is, this instrument does the jobs of three just by one. It can be used for measurements of instantaneous, integration and also demand values.
Measured data can be saved in SD card or the internal memory, and the data can be t USB. Measured data can be checked on android devices in real-time by using Bluetooth function.
Safety construction
Designed to meet the international safety standard IEC 61010-1 CAT.III 600V
Wiring configration
KEW6305 supports: Single-phase 2-wire, Single-phase 3-wire, Three-phase 3-wire and Three-phase
4-wire
Measurement and calculation
KEW6305 measures voltage (RMS), current (RMS), active power, frequency and calculates reactive/
apparent power, power factor, neutral current (Three-phase 4-wire only) and active/ reactive/ apparent energy.
Demand measurement
Electricity consumption can be easily monitored so as not to exceed the target maximum demand
values.
Saving data
Instantaneous values can be saved every time pressing the
values can be saved for various periods from 1 second up to 1 hour. The maximum, minimum and average values of instantaneous values during each cycle can also be saved.
Dual power supply system
KEW6305 operates either with an AC power supply or with batteries. In the event of interruption,
while operating with an AC power supply, power to the instrument is automatically restored by the batteries in the instrument.
Large display
Up to 3 measured items can be displayed on the large screen simultaneously. (e.g. voltage, current and active power)
Backlight
Backlight to facilitate working in dimly illuminated areas
Light & compact design
Clamp sensor type, compact and light weight design
W
Key. Integration and demand
SAVE
ransmitted to PC via
Application
Data in the internal memory and in SD card can be transferred to PC using USB connection or SD
slot. The supplied PC software application enables easy settings of the instrument and analysis of the saved data from PC, moreover, can synchronize recording intervals and internal clocks of two KEW6305 to perform synchronous measurement. Measured data can be checked on android devices in r
KEW6305
Find Quality Products Online at: sales@GlobalTestSupply.com
eal-time via Bluetooth communication.
2
www.GlobalTestSupply.com
Functional Overview
KEW6305Functional Overview
SET UP
Configures KEW6305 and makes settings for measurements.
WIRING CHECK
Performs a check for proper connection.
(Section 10) “Wiring check”
See
for further details.
[W] Instantaneous value measurement
Measures average, max, min values of instantaneous values of current, voltage and electric power.
(Section 6) “Instantaneous value measurement”
See for further details.
[Wh] Integration value measurement
Measures active/apparent/reactive powers on each CH.
(Section 7) “Integration value measurement”
See for further details.
DATA CHECK
Displays the saved data on the LCD.
(Section 11) “Data Check”
See details.
for further
3
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
[DEMAND] Demand value measurement
Measures demand values based on the preset target values.
(Section 8) “Demand measurement”
See further details.
KEW6305
for
KEW6305 Instrument Layout
2. Instrument Layout
Front view
Display
LCD
Keys
Function Switch
Power on/ off, select Measurement range.
W SAVE
Save measured
W
SAVE
instantaneous values
Key
Status indicator LED
Light up: Recording& Measuring
Green
Blink: Stand-by
Red Light up: Recording error
START/ STOP
Start/stop integration &
START /STOP
demand measurements
Backlight
Turn on/off the LCD backlight
Cursor
Select settings, switch screens
ENTER
Confirm entries
ENTER
ESC
Cancel setting change or cl ear i nte grati on/
ESC
demand data selected with
RESET
/
Cursor
Key
Key
Key
Key
Key
Key
DATA HOLD
Freeze the readings on the LCD. * Measurement is being performed while the readings are
being fixed.
DATA HOLD
A long press (2 sec or longer) disables all Keys (except for Backlight Key) to prevent operational errors in recording. Another long press (2 sec or longer) can restore the disabled Keys.
KEW6305
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
4
KEY LOCK
/
Key
Connector
Power Connector
Side face
< When the Connector Cover is closed >
SD Memory Card
KEW6305Connector
Voltage Input Terminal
(VN, V1, V2, V3)
Current Input Terminal
(A1, A2, A3)
Terminal Cover
< When the Connector Cover is opened >
SD Card Cover
USB Port Cover
Symbols displayed on the LCD < All symbols >
Wiring system
Phase No.
Voltage range
5
SD Card Slot
Current range
Units
USB Port
KEW6305
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
KEW6305 Symbols displayed on the LCD
< Symbols appear to show the state of the instrument or measurement >
Symbol Description
Keys are being locked.
Preset voltage value is exceeded.
Preset current value is exceeded.
Operating with AC power supply.
Operating with batteries.
Data hold function is active.
SET UP Range is selected.
WIRING CHECK Range is selected.
Blinks while instantaneous value is being displayed on the LCD.
Blinks while integration value is being displayed on the LCD.
Blinks while demand value is being displayed on the LCD.
Capacity of SD card or internal memory is full.
DATA CHECK Range is selected.
Data can be saved in the SD card. * Blinks while saving data.
USB cord is connected to the terminal. * Blinks during data communication.
Using Bluetooth communication.
Data can be saved in the internal memory. * Blinks while accessing to the memory.
VT ratio is set to other than 1.
CT ratio is set to other than 1.
KEW6305
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
6
KEW6305Preparations
3. Preparations
Battery
KEW6305 operates either an AC power supply or batteries. Capable of performing measurements in an event of AC power interruption, power to the instrument is automatically restored by the batteries installed in the instrument. Size AA alkaline dry-cell batteries (LR6) can be used.
If an AC power supply is interrupted and batteries have not been installed, the instrument w off and the measuring data may be lost.
Indication on screen
Symbol of power supply displayed on each measurement screen changes as follows.
< During AC power supply operation > < During battery operation > AC power supply symbol ( ) appears. Battery symbol ( ) appears.
Battery condition Battery symbol changes as follows depending on battery condition.
Battery operating time
For approx. 15 hours, with new alkaline batteries. * It is reference time and will be shortened if using the backlight or
Bluetooth function.
ill be powered
Batteries are exhausted. (Accuracy of readings cannot be guaranteed.) Depending on the states of measurement, instrument operates as follows automatically. * while saving instantaneous value data (Files are opened.)
-> Close the open files. (Data will be saved.) * while measuring integration/ demand values
-> Force-quit measurements. (Data will be saved.)
How to install batteries
Install batteries in correct polarity as marked inside. Remove all the batteries if the instrument is to be stored and will not be in use for a long period.
7
KEW6305
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
KEW6305 Cord connection
Cord connection
Voltage test lead
Match the arrow marks.
Power cord
Rated supply voltage : 100 - 240VAC(±10%) Rated supply frequency : 45 - 65Hz Max power consumption : 10VAmax
Clamp sensor
Start-up screen
KEW6305 will be powered on when setting the Function switch to any position other than OFF. All of the LCD segments will be displayed first, and then model name with version information. After that, stand-by screen for the selected range will be displayed. Upon powering on the instrument, self-check routine initiates automatically. Stop using the instrument if error message appear on the LCD after self-check and refer to instruction manual.
KEW6305
8
(Section 15) Troubleshooting
Error No. (001 – 063)
in the full
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Loading...
+ 21 hidden pages