INSTRUCTION MANUAL CLAMP ADAPTOR
Model 8006
1. Features
・ Clamp adaptor designed to measure AC current up to 1,500A.
・ Can accommodate up to 60mm-dia conductor or 50mm by 75mm bus-bar.
2.Specifications 3.Designations
Measuring range
Accuracy
Output Voltage
Load Resistance
Allowable
Measurement
Time
Output Leads 2m long with 4mm-dia banana plugs
Frequency Range
Dimensions
Weight Approx.500g
Conductor Size 60mm max. Outside diameter or
0~1.5V AC against 0~1,500A AC
600~1,000A 30 minutes max.
1,000~1,500A 5 minutes max.
45 Hz~65Hz
240(L) × 85(W) × 30(D)mm
50mm × 75 mm (bus-bar)
4.Operating Instructions
4.1 Preparation for Measurement
Connect output leads to an AC voltmeter.
The output voltage of the clamp adaptor is 1.5V against 1,500A Input current.
Select an appropriate range of voltmeter in accordance with the current to be measured.
4.2 AC Current Measurement
Press the trigger to open the transformer jaw and clamp on a conductor.
Take the reading of the voltmeter and convert it into amperage.
For example, the reading and measured value will be as follows when the 0 to 2V range
of a digital multi meter is used:
Reading of Digital Multimeter Measured Value
1.200V 1,200A
Be careful about the fact that the transformer jaws with overheat when continuous measurements are made
of 600 to 1,000A for more than 30 minutes or 1,000 to 1,500A for more than 5 minutes.
DISTRIBUTOR
92-1809A
0~1,500A AC
0~1,000A AC
±3%rdg±1A
1,000A~1,500A AC
±5%rdg
More than 1kΩ
0~600A continuous
①
②
③
① Transformer Jaws
② Trigger
③ Output Leads
Kyoritsu reserves the right to change specifications or
designs described in this manual without notice and without.