MOUNTING GUIDE
FOR THE
KD135GX-LFBS~KD245GX-LFB
SOLAR PHOTOVOLTAIC POWER MODULES
Please read this guide carefully before installing the modules.
KD series modules may be attached to a support structure by the following methods. Detailed mounting method is
described in ‘mounting table’. When installing modules in snowy area, an appropriate countermeasure ha s to be taken to
prevent possible damages to the lower side frame by slipping snow (e.g. attach supporting parts to the lowest modules.).
Any damage caused by snow or such countermeasure is not covered under warranty.
For optimal performance in all applications, clearance between the module frame and the mounting surface is required to
allow cooler ambient air to circulate around the back of the module and to avoid the mod ule an d / or wiring damage.
The minimum spacing of 2” (50 mm) is required between PV module and the mounting surface around the perimeter of PV
OF
KYOCERA
2011.11.1
module. There should also be a clearance of at least .13” (3.2 mm) between the individual modules to allow heat-related
expansion.
BOLTING: Utilizing 5/16” or 8 mm steel hardware structure through the existing .35” (9 mm) diameter mounting holes i n the
module frame and then through
KD series modules mounting holes on the support structure.
Tighten the screws with adequate torque (usually 132 in-lb).
Support structure should have enough strength to keep the mounting span.
Refer to the below table for the position of PV module mounting holes.
CLAMPING: Fasten modules firmly with the clamps which must not be deformed by wind load or snow load, nor cause the
module fall off by using torque values specified by structure manufacturers.
Minimum 40mm clamping width, and minimum 9mm overlap onto frame are necessary.
Clamps also must not shade the sunlight incidence on glass surface.
Clamp material must be either stainless steel or anodized alumin um.
Support structure should have enough strength to keep the mounting span.
Refer to the below table for the permissible clamping range.

Mounting table-1
Bolting
KD235GX-LFB
KD240GX-LFB
KD245GX-LFB
Long side
Top down
clamp
: Permissible
clamping range
281mm 1100mm
100mm
281mm
100mm 100mm
1100mm
281mm 1100mm
100mm
100mm
100mm
1100mm
100mm
281mm
100mm