KYLAND Technology KIEN1008G Hardware Installation Manual

1
KIEN1008G
Industrial Ethernet Switch
Hardware Installation Manual
Kyland Technology Co., LTD.
Publication Date: Oct. 2011
Version: V1.0
Customer Service Hotline: (+8610) 88796676
FAX: (+8610) 88796678
Website: http://www.kyland.cn
E-mail: support@kyland.biz
No.: 1.12.02.1029-0
2
KIEN1008GIndustrial Ethernet Switch Hardware Installation Manual
Disclaimer: Kyland Technology Co., Ltd. tries to keep the content in this manual as accurate and
as up-to-date as possible.This document is not guaranteed to be error-free, and we reserve the
right to amend it without notice.
All rights reserved.
No part of this documentation may be excerpted, reproduced, translated, annotated or duplicated,
in any form or by any means without the prior written permission of KYLAND Corporation.
Copyright ©2011 KYLAND Technology CO., LTD.
3
Notice for Safety Operation
This product performs reliably as long as it is used according to guidelines. Artificial damage or
destruction of the equipment should be avoided.
z Read this manual carefully and keep it for future reference;
z Do not place the equipment near water sources or damp areas;
z Do not place anything on power cable and put the cable in unreachable places;
z Do not tie or wrap the cable to prevent fire.
z Power connectors and other equipment connectors should be firmly interconnected
and checked frequently.
z Do not repair the equipment by yourself, unless it is clearly specified in the manual.
z Please keep the equipment clean; if necessary, wipe the equipment with soft cotton cloth.
In the following cases, please immediately cut off the power supply and contact our company:
z Water gets into the equipment;
z Equipment damage or shell breakage;
z Equipment operation or performance has abnormally changed;
z The equipment emits odor, smoke or abnormal noise.
4
Contents
1. Packing List .......................................................................................................... 5
2. Product Overview ................................................................................................. 5
3. Structure and Interface ......................................................................................... 5
3.1 Front Panel ..................................................................................................... 5
3.2 Top Panel ........................................................................................................ 7
4. Mounting ............................................................................................................... 7
4.1 Mounting ......................................................................................................... 7
4.2 Mounting Steps ............................................................................................... 8
5. Cable Connection ............................................................................................... 11
5.1 10/100/1000Base-T(X) .................................................................................. 11
5.2 Combo port ................................................................................................... 12
5.3 Power ............................................................................................................ 14
5.4 Grounding ..................................................................................................... 15
6. LED Indicators .................................................................................................... 17
7. Product Models and Accessories ........................................................................ 18
8. Basic Features and Specifications ...................................................................... 18
5
1. Packing List
KIEN1008G Industrial Ethernet Switch 1
Hardware Installation Manual 1
Certificate of Quality (including Warranty Card) 1
Note: After unpacking, please check the accessories and the appearance of the equipment. If
anything is missing or damaged, please contact us.
2. Product Overview
KIEN1008Gis a series of green, low power consumption, DIN-Rail
industrial Ethernet switch that can be applied extensively in wind power,
distribution network automation, subway PIS, power SCADA, wastewater
treatment, metallurgy, intelligent transportation, rail transit and many other
industries.
KIEN1008G industrial Ethernet switch supports DIN-Rail and panel mounting. It
supports IP40 protection class and provides abundant Gigabit ports.
3. Structure and Interface
3.1 Front Panel
KIEN1008G supports two kinds of product models. The interface is different for
each product model.
z KIEN1008G-2GX/GE-6GE front panel is shown in Figure 1 below
6
1: PWR1-Power 1 LED
2: PWR2-Power 2 LED
3: Combo port (SFP)Link/ACT LED
4:Combo port(SFP) Speed LED
5:(GX7/GE7、GX8/GE8)-two Combo
ports
6:(GE1-GE6)-six 10/100/1000Base-T(X)
RJ45 ports
7:RJ45port Speed LED
8:RJ45portLink/ACT LED
Figure 1 Front Panel 1
z KIEN1008G-8GE front panel is shown in Figure 2 below
1: PWR1-Power 1 LED
2: PWR2-Power 2 LED
3:(GE1-GE8)-eight 10/100/1000Base-T(X)
RJ45 ports
4:RJ45port Speed LED
5:RJ45portLink/ACT LED
Figure 2 Front Panel 2
7
3.2 Top Panel
1: Terminal block for power input
2: Screw hole for grounding
Figure 3 Top Panel
4. Mounting
4.1 Mounting
z Dimension Drawing for DIN-Rail Mounting (Unit: mm)
Figure 4 DIN-Rail Mounting
8
z Dimension Drawing for Panel Mounting (Unit: mm)
Figure 5 Panel Mounting
4.2 Mounting Steps
z KIEN1008G DIN-Rail Mounting
The specific steps are as follows:
Step 1: Select the mounting position for KIEN1008G and ensure that there is
adequate space.
Step 2: Insert the top of the DIN-Rail into the spring-supported slot of the
DIN-Rail connecting seat in the rear panel of KIEN1008G as seen below;
move the device in the direction of arrow 2 to put the whole Din-Rail into place;
verify the KIEN1008G is firmly mounted on the DIN-Rail, as shown below.
Figure 6 DIN-Rail Mounting
9
z Remove KIEN1008G from DIN-Rail
The specific steps are as follows:
Step 1: Place the screwdriver into the hole at the bottom of spring locking
plate; press the plate down to loosen the connection of DIN-Rail and switch,
as shown in arrow 1.
Step 2: Pull the KIEN1008G up in the direction of arrow 2; meanwhile remove
the device from the DIN-Rail along the direction of arrow 3.
Figure 7 DIN-Rail Dismounting
z KIEN1008GPanel Mounting
The specific steps are as follows:
Step 1: Select the mounting position for KIEN1008G on the wall or in cabinet;
ensure that there is adequate space for the switch.
Step 2: Drill 4 holes on the selected position according to the panel mounting
dimension drawings; use a cross-screwdriver to screw 4 cross-slot screws
(M3×10) into holes. Don’t tighten the screws completely; leave about 5mm of
space between.
Step 3: Aim 4 mounting holes on KIEN1008G mounting plate at 4 fixed
screws; pass the screws through 4 holes with the diameter of 6.5mm (Ф6.5);
then slide down KIEN1008G as seen below; finally screw 4 screws tightly.
10
Now the KIEN1008G should be firmly fixed to the wall or cabinet.
Figure 8 Panel Mounting
z Remove KIEN1008G from wall or cabinet
The specific steps are as follows:
Step 1: Use a screwdriver to loosen 4 screws; move the device up to let
screws into 4 holes with the diameter of 6.5mm (Ф6.5).
Step 2: Unscrew the screws from wall or cabinet; remove the device from wall
or cabinet.
Figure 9 Panel Dismounting
11
5. Cable Connection
5.1 10/100/1000Base-T(X)
10/100/1000Base-T(X) Ethernet RJ45 port can be connected to terminal
equipment and network devices with straight-through cables or crossover cables.
RJ45 connectors must be attached at both ends of cable.
z RJ45 port and pin number
Figure 10 RJ45 Port
z Pin distribution of 10/100/1000Base-T(X)
Table 1Pin Distribution of 10/100/1000Base-T(X)
Pin MDI MDI-X
1
Output/Receiving data(TRD0+) Output/Receiving data(TRD1+)
2
Output/Receiving data(TRD0-) Output/Receiving data(TRD1-)
3
Output/Receiving data(TRD1+) Output/Receiving data(TRD0+)
4
Output/Receiving data(TRD2+) Output/Receiving data(TRD3+)
5
Output/Receiving data(TRD2-) Output/Receiving data(TRD3-)
6
Output/Receiving data(TRD1-) Output/Receiving data(TRD0-)
7
Output/Receiving data(TRD3+) Output/Receiving data(TRD2+)
8
Output/Receiving data(TRD3-) Output/Receiving data(TRD2-)
Note: “+”“-“ mean level polarity.
z 1000M straight-through cable wiring
8 7 6 5 4 3 2 1
12
Figure 11 1000M Straight-through Cable Wiring
z 1000M crossover cable wiring
Figure 12 1000M Crossover Cable Wiring
5.2 Combo port
A Combo port is on the front panel, which consists of one RJ45 port and one
gigabit SFP slot that accepts a modular SFP optical fiber transceiver. The RJ45
13
port and its related fiber port are both always connected but cannot be used
simultaneously.
z For RJ45 port please refer to section 5.1 z 1000BaseSFP
¾ 1000Base SFP(1.25Gbit/s)Parameter Table
Table 2 1000Base SFP(1.25Gbit/s) Parameter Table
Property
SX LX LH ZX ZX
Type
Multi Mode
(M)
Single Mode
(S)
Single Mode
(S)
Single Mode
(S)
Single Mode
(S)
Center Wavelength
(nm)
850 1310 1310 1550 1550
Transmission Distance(Km)
0.55 10 40 60 80
Application Range of
Transmission Distance(Km)
0~0.55 0~10 12~40 24~60 27~80
Transmitting
Optical Power
Mini. (dBm)
-11 -10 -4 -3 -2
Max.
(dBm)
-2 -3 3 4 5
Receiving
Sensitivity(dBm)
-18 -21 -23 -22 -25
Overload Optical Power
dBm
0 -3 -3 -3 -3
¾ Figure 13shows an example of an SFP gigabit optical fiber transceiver
Figure 13 SFP Gigabit Optical Fiber Transceiver
14
¾ Wiring
While wiring, first insert the SFP modular into the SFP slot in the device, and
then plug the optical fiber into the SFP module. See Figure 14
Figure 14 SFP Gigabit Optical Fiber Transceiver Wiring
5.3 Power
According to the power input requirements, use a 5.08mm-spacing terminal block
to connect the power cable.
Note: The cross section area of the power cable is required to be greater than 0.75mm
2
and less
than 2.5mm2. The grounding resistance requirement: <5Ω.
z
5.08mm power terminal block pin number is shown in Figure 15
Figure 15 Pin 5.08mm Power Terminal Block
z
5.08mm power terminal block contact definition
15
Table 3 Contact Definition
Contact number DC wiring definition AC wiring definition
1 PWR1: + PWR1: L
2 PWR1: - PWR1: N
3 Protection Ground Protection Ground
4 PWR2: - PWR2: N
5 PWR2: + PWR2: L
z Wiring and mounting
Step 1: Take the power terminal block off KIEN1008G
Step 2: Insert the power cable into the terminal block and fix the power cable
Step 3: Put the terminal block back to KIEN1008G with the connected cable
5.4 Grounding
z Chassis grounding and power terminal grounding
Figure 16 Chassis Grounding and Power Terminal Grounding
16
There is a grounding screw on the top panel of the KIEN1008G, which is for
chassis grounding. One end of the chassis grounding cable is connected with
the grounding screw and the other end of the cable is reliably grounded. (The
cross section area of chassis grounding cable should be more than 2.5mm2.
The grounding resistance requirement: <5Ω)
The grounding part in the 5.08mm power terminal block is called surge
grounding.
It is required to connect the chassis grounding part with the surge grounding
part by an18#AWG yellow-green line as seen below
z 18#AWG yellow-green line (Unit: mm)
Figure 17 18#AWG Yellow-green Line
Note: IfKIEN1008G needs to do a dielectric voltage withstand test, in order to ensure proper
testing, please disconnect the 18#AWG yellow-green line to disable surge protection circuit that
connects to surge grounding
17
Figure 18 Disconnect 18#AWG Yellow-green Line
6. LED Indicators
Table 4 KIEN1008G LED Indicators
LED State Description
Power LEDs
PWR1
ON Power 1 connects and operates normally.
OFF Power 1 disconnects or operates abnormally.
PWR2
ON Power 2 connects and operates normally.
OFF Power2 disconnects or operates abnormally.
Combo port(SFP) LEDs
Speed
(Yellow)
ON 1000M working state (i.e. 1000Base-X)
OFF 100M working state (i.e. 10/100Base-FX) or no connection
Link/Act
(Green)
ON Effective network connection in the port
Blinking Network activities in the port
OFF No effective network connection in the port
Ethernet RJ45 port LEDs
Each RJ45 Ethernet port has two indicators a yellow LED and a green LED. The yellow LED
indicates port rate, while the green LED indicates port connection state.
Speed ON 1000M working state
18
(Yellow) OFF 10/100M working state or no connection
Link/Act
(Green)
ON Effective network connection in the port
Blinking Network activities in the port
OFF No effective network connection in the port
7. Product Models and Accessories
z The specific configuration models of KIEN1008G are shown in Table 5
Table 5 KIEN1008G Configuration Table
Model Description Power
KIEN1008G-2GX/GE-6GE 2 1000M Combos Ports,
6 10/100/1000Base-T(X)
RJ45 Ports
12VDC(9~36VDC),
24VAC/DC(18~50VAC/18-72VDC),
dual redundant power inputs
KIEN1008G-8GE
8 10/100/1000Base-T(X)
RJ45 Ports
z The optional accessories of KIEN1008G are shown in Table 6
Table 6 KIEN1008G Optional Accessories
Model Description
DT-BGAZ-02 Panel mounting kit
DT-FCZ-RJ45-01 RJ45 dustproof shield
8. Basic Features and Specifications
z Cable
Twisted Pair: 100m (Standard CAT5, CAT5e network cable)
Multi Mode Fiber: 850nm, 550m (1000Mbps)
Single Mode Fiber:1310nm, 10Km/40Km(1000Mbps);
1550nm, 60Km /80Km(1000Mbps)
19
z Power Requirements
Power input: 12VDC (9~36VDC), 24VAC/DC (18~50VAC, 18~72VDC)
Power terminal: 5-pin 5.08mm-spacing plug-in terminal block
Power consumption: full load:
KIEN1008G-2GX/GE-6GE: 8.5W(full load)
KIEN1008G-8GE: 7.5W(full load)
z Physical Characteristics
Housing:Metal,fanless
Installation: DIN-Rail or Panel mounting
Dimensions (W×H×D): 88mm×135mm×137mm
Weight: 0.76Kg
z Environment Limits
Operating Temperature: -40 to 85℃ (-40 to 185℉)
Storage Temperature: -40 to 85(-40 to 185℉)
Ambient Relative Humidity: 5% to 95% (non-condensing)
z MTBF: 357000h z Warranty: 5 years
Loading...