KwiKool AtticMaster Series
KAM
Operation Manual
Table of Contents
Section I / Unit Components - Page: 3
Section II / Introduction - Page: 3
Section III /Quick Start Procedure - Page: 4
Section IV / Operating Procedure- Page: 4
Section V / Important Notes - Page: 4
Before installing and using your KwiKool Portable Cooling
System, read this manual carefully for instructions and
proper usage and all safeguards.
This manual should be retained for future reference.

I / Unit Components
1
7
3
2
4
6
8
5
9
Legend
1. Duct Clamp
1. Duct Clamp
2. 30’ Duct
2. 30’ Duct
3. Condensate Tank
3. Condensate Tank
4. On/Off Switch
4. On/Off Switch
5. High Low Switch
5. High Low Switch
6. Fan/Cool Switch
7. Handle
8. Hot Air Exhaust
9. 8” Wheel
II / Introduction
The KwiKool AtticMaster is designed to move conditioned air up to 90’ into a hot ambient
environment in order to provide spot cooling. The duct opening must be placed within 5’ of
the person being cooled for effective use. The specially made insulated duct is guaranteed
not to form condensation on the outside of the duct. The outside duct covering has air
holes, which allow it to be easily compressed back into its carry bag.
Page 3

III / Quick Start Procedure
Select Location of System - Make sure all sides of unit are not blocked to avoid
A.
restricted air flow.
B.
Remove duct from bag - Attach duct clamp to the ring on top of the unit, making sure
the clamp is tight and run eyelets into the ring.
C.
Attaching extra 30’ length of duct - Squeeze duct end loop and insert into first duct
end loop. A maximum of three 30’ lengths of duct can be used for a total maximum
length of 90’. At least one 30’ length must be connected to the unit for proper back
pressure.
D.
Outlet - Only use a dedicated 115 Volt / 15 Amp circuit, such as the outlet for a
washing machine.
IV / Operating Procedure
A.
The AtticMaster controls are located on the top right side on the front of the unit.
There are 3 switches (See Unit Components):
1.
On/Off Switch - 2-position switch, turns unit on or off.
2.
Fan/Cool Switch - 2-position switch, turns unit fan only on or fan with compressor
on.
3.
Low/High Switch - 2-position switch, turns the fan from low speed for use with a
30’ duct or high for use with a 60’/90’ duct.
B.
Condensate tank with a float switch is located in the front lower compartment of the
unit. When the tank is full a beeping alarm will sound. When removing the tank,
unplug the float jack. When replacing the tank make sure that the drain line is in the
tank and the float jack is plugged in.
V / Important Notes
Always keep the unit in an upright position, do not lay down. If the unit is laid down, the
A.
unit must be placed upright and not turned on for at least 4 hours, or compressor
damage may occur, due to compressor oil displacement.
B.
Filters should be changed as needed or at least once every 2 months. Remove filter
from slot on top of unit by turning the 2 latch screws. The filter size is 12” x 12” x 1”
(LxWxD)
If the air flow is blocked from the intake or exhaust grills the unit will go into alarm, due
C.
to high pressure on the compressor. Press the High Pressure reset button on the back
of the unit, which will clear the alarm.
Call 1-800-KWIKOOL (800-594-5665) for Service or Questions
Page 4