KV2 Audio VHD3200 User Manual

VHD3200
User Guide
LIMITER
POWER ON /
SIGNAL PRESENT
THERMAL (AUTO RESET)
The future of sound. Made perfectly clear.
At KV2 Audio our vision is to constantly develop technologies that eliminate distortion and loss of information providing a true dynamic representation of the source.
Our aim is to create audio products that absorb you, place you within the performance and deliver a listening experience beyond expectation.
BRIDGE
3200W / 8
1600W / 4
OUTPUT A
INPUT A
ON
BRIDGE - INPUT A
1600W / 4
OUTPUT B
DESIGNED BY KV2 AUDIO
WWW.KV2AUDIO.COM
A
AC IN
B
AC IN
SERIAL NUMBER
INPUT B
OFF
IMPORTANT SAFETY INSTRUCTIONS
Before using your VHD3200, be sure to carefully read the applicable items of these operating instructions and the safety suggestions
1. Keep this manual for future reference.
2. Heed all warnings.
3. Follow all instructions.
4. Do not use this unit near water . Do not spill water or other liquids into or on the unit. Do not operate the VHD3200 while wet or standing in liquid.
5. Clean only with a dry cloth.
6. Do not block the air intake or exhaust ports. Install the unit in accordance with the instructions.
7. Do not operate the VHD3200 near heat producing devices such as radiators, heat registers, stoves or other apparatus that produce heat.
8. Always operate the unit with the chassis ground wire connected to the electrical safety earth. Do not defeat the safety purpose of a grounding-type plug. A grounding type plug has two pins and a third grounding prong. The third prong is provided for your safety. If the provided plug does not t into your outlet, consult an electrician for replacement of the obsolete outlet.
9. Connect only to AC power outlets rated 115, 230 or 250V , 50-60Hz.
10. Do not use this VHD3200 if the power cable is broken or frayed. Protect the power cable from being walked upon or pinched particularly at the plugs and the point where it exits from the apparatus.
11. Only use accessories specied by the manufacturer .
12. The unit is intended to be used in a 19” rack. Follow the mounting instructions. When a rack on wheels is used, use caution when moving the loaded rack to avoid injury from tipping over.
13. Unplug this apparatus during lightning storms or when unused for long periods of time.
14. Do not connect a VHD3200 output in parallel or series with any other VHD3200’s output. Do not connect the VHD3200 output to any other voltage source, such as battery, mains source, or power supply, regardless of whether the VHD3200 is turned on or o.
15. Do not run the output of any VHD3200 back into another channel's input.
16. Refer all servicing to qualied service personnel. Servicing is required when the apparatus has been damaged in any way such as:
t1PXFSTVQQMZDPSEPSQMVHJTEBNBHFE  t-JRVJEIBTCFFOTQJMMFEJOUPUIFVOJU  t"OPCKFDUIBTGBMMFOJOUPUIFVOJU  t5IFVOJUIBTCFFOFYQPTFEUPSBJOPSNPJTUVSF  t5IFVOJUEPFTOPUPQFSBUFOPSNBMMZ  t5IFVOJUXBTESPQQFEPSUIFFODMPTVSFJTEBNBHFE
17. Do not remove top or bottom covers. Removal of the cover will expose hazardous voltages. There are no serviceable parts inside and removal may void the warranty.
18. An experienced user shall always supervise this professional audio equipment, especially if inexperienced adults or minors are using the equipment.
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE THE COVER. NO USER-SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED PERSONNEL.
WARNING: To prevent re or electric shock, do not expose this equipment to rain or moisture.
1. Introduction, Warranty
2. Getting Started
2.1 Unpacking
2.2 Rack Mounting
2.3 Cooling
2.4 AC Requirements
3. Features
3.1 Front panel
3.2 Rear panel
4. Operation
INDEX
5. Specications
1
INTRODUCTION, WARRANTY
Thank you for purchasing this KV2 Audio VHD3200 subwoofer amplier. This manual contains important information on operating this unit correctly and safely. Please take some time and read this manual to familiarise yourself with the advanced features of this unit.
The VHD3200 is a rack mounted subwoofer amplier. The unit contains two separate 1600 watt ampliers with individual power supplies, signal paths and inputs and outputs within a single four rack space chassis. The unit can be used in bridged mode to provide full power for one channel mode. The unit acts as a slave for the VHD2000, which provides audio and control signal. It can also be used with the EPAK2500/R when used in combination with KV2 Audio ES systems and power the associated ES subwoofer systems.
Although this unit is simple to operate improper use can be dangerous. This is a very high­powered device that can put out high voltages and sizable currents. Always use safe operating techniques with the VHD3200.
FOR YOUR SAFETY , READ THE IMPORTANT PRECAUTIONS SECTION AS WELL AS THE INPUT, OUTPUT AND POWER CONNECTION SECTIONS OF THIS MANUAL.
WARRANTY
Your VHD3200 is covered against defects in material and workmanship. Refer to your supplier for more details.
SERVICE
In the unlikely event that your VHD3200 develops a problem, it must be returned to an authorized distributor , service centre or shipped directly to our factory. Because of the complexity of the design and the risk of electrical shock, all repairs must be attempted only by qualied technical personnel.
If the unit needs to be shipped back to the factory, it must be sent in its original carton. If improp­erly packed, the unit may be damaged. To obtain service, contact your nearest KV2 Audio Service Centre, Distributor or Dealer .
GETTING STARTED
2.1 UNPACKING
Unpack the VHD3200 and check to see if there is any damage to it. If you nd any damage notify your supplier immediately. Only the consignee may institute a claim with the carrier for damage incurred during shipping. Be sure to save the carton and all packing materials for the carrier's inspection.
Should you ever need to ship the unit, only use the original factory packaging. If the shipping carton is unavailable, contact your supplier to obtain a replacement.
The VHD3200 carton should contain:
t7)%BNQMJöFSDPOUSPMVOJU t6TFSHVJEF t1PXFS$POEFUBDIBCMFQPXFSDBCMF
2
2.2 RACK MOUNTING
VHD3200’s will mount in standard 19" rack systems. Integral rear mounting rack ears are also provided for additional support, do not rely on xing and mounting the VHD3200 using just the front panel as support. Use eight screws and washers to mount the amplier to the equipment rack rails (four for the front and four for the rear). We recommend using a shock mounted rack for touring use to prolong the life of your VHD3200.
LIMITER
SIGNAL PRESENT
POWER ON /
THERMAL (AUTO RESET)
BRIDGE - INPUT A
ON
OFF
OUTPUT A
WWW.KV2AUDIO.COM
DESIGNED BY KV2 AUDIO
MANUFACTURED IN THE EUROPEAN UNION
1600W / 4
3200W / 8
OUTPUT B
1600W / 4
BRIDGE
INPUT A
INPUT B
AC IN
SERIAL NUMBER
AC IN
B
A
2
GETTING STARTED
2.3 COOLING
The VHD3200 has a comprehensive cooling system featuring chassis-sealed PCB board mounting and shock mounted, speed controlled fans. This means that the cooling system never drives air across PCB boards, connectors or components ensuring prolonged electronic component lifespan and minimizing maintenance cycles.
Air is drawn into the front of the amplier by the two fans on the rear panel, this passes over the cooling ns of the heat sinks and exhausts through the rear. If the heat sink gets too hot, its sensing circuit will open the output relay, disconnecting the load.
It is important to have an adequate air supply at the front of the amplier, and enough space around the rear of the amplier to allow the cooling air to escape. If the unit is rack mounted, do not use doors or covers on the rear of the rack; the exhaust air must ow without restriction. If you are using racks with closed backs, use fans on the rear rack panel to ensure an ample air supply.
2.4 AC REQUIREMENTS
Two PowerCon cables are provided to connect the VHD3200 to a suitable AC power supply.
The PowerCon is a connector without breaking capacity, i.e. the PowerCon should not be connected or disconnected under load or while it is live. Always isolate your AC supply before disconnecting the PowerCon connector.
Your VHD3200 will be supplied pre set to the voltage used in your area. The table below provides typical current draw gures for the VHD3200.
AC Input
250V
230V
115V
Current draw with
amplier running at Average
Power (Each Channel)
5.5A
6A
12A
Current draw with
amplier running at
Peak Power (Each Channel)
11A
12A
24A
Remember that if you are connecting both AC cables for the VHD 3200 to the same AC power source then you will need to have double the per channel current available.
3.1 FRONT PANEL
/
)
SIG
3
FEATURES
1
SIGNAL PRESENT
NALSNT
POWER ON /
POWER ON
THERMAL (AUTO RESET)
THERMAL (AUTO RESET
2
LIMITER
4
3
1) AC Mains Switch
The VHD 3200 has combination AC Mains switch/circuit breakers on the front panel. If either of the switches shuts o during normal use, push it back to the ON position once. If it will not stay on you should take the unit to qualied service personnel tohave it serviced.
2) Power On / Thermal
These are dual colour LED’s. When green they indicate that the Power Switch is On and that channel of the amplier is powered up. When red they indicate that that channel has overheated and shut down. The unit will Auto Reset after it cools down to a safe operating temperature.
3) Signal Present
These green LED’s indicate when signal is present at the Input to that particular channel of the amplier.
4) Limiter
These red LED’s indicate when the audio limiter has been activated for that particular channel of the amplier.
3
NAC IN
S
R
W
COM
DESIG
O
MANUFACTU
ON
BRIDGE - INPUT A
INPUT
UT
1600W / 4
BRIDGE
OUTPUT
INPUT
O
ON
3
OUTPUT
FEATURES
3.2 REAR PANEL
1
BRIDGE - INPUT A
ON
OFF
FF
INPUT A
INPUT B
SERIAL NUMBER
ERIAL NUMBE
AC IN
3
AC IN
B
A
AC I
4
WWW.KV2AUDIO.COM
WW.KV2AUDIO.
DESIGNED BY KV2 AUDIO
NED BY KV2 AUDI
RED IN THE EUROPEAN UNI
MANUFACTURED IN THE EUROPEAN UNION
5
OUTPUT A
1600W / 4
BRIDGE
3200W / 8
OUTPUT B
1600W / 4
62
1) Main Input A/B
These are the input connectors for channels A & B with associated 'Through Output' connectors for sending signal to other devices.
2) Bridge Mode Switch
When running VHD3200 in bridge mode (bridge switch pressed), Input A serves as a bridge mode input, bridge output (6) serves as speaker output. Input B provides phase reversed Input A signal.
3) PowerCon Power Connectors
One for each channel of the VHD3200 both must be connected to operate both channels of the VHD3200. They accept standard PowerCon terminated AC Mains cables.
4) Fans
The cooling fans operate continuously while the VHD3200 is on. An internal temperature sensor increases the speed of the fans during high temperature conditions. Air enters through the front grille and exits through the rear. Be sure to allow adequate air ow to the front of the rack in which the VHD3200 is mounted.
5) EP4 Connectors
One for each channel of the VHD3200. They accept standard EP4 terminated loudspeaker cables.
6) Bridge Mode EP4 Connector
Output channel of the VHD3200 when running in bridge mode. Accepts standard EP4 terminated loudspeaker cables. Do not connect other speakers to speakers output A and output B in bridge mode.
OPERATION
The VHD3200 is designed to be used either with the VHD2000 or the EPAK2500/R controller ampliers and to power only certain combinations of KV2 Audio Subwoofers. Because of its unique design it cannot be used as a standard power amplier to power any other loudspeakers without the possibility of damage occurring. The various VHD2000 combinations are shown in the following table:
4
Amplier / Controller Setting
VHD2000 Setting 1 2 x VHD2.16 (1x2.15) 2 x VHD2.16 (1x2.15) VHD2000 Setting 1B VHD2000 Setting 2 VHD2000 Setting 3 VHD2000 Setting 4 VHD2000 Setting 5 VHD2000 Setting 6
NOTE: Settings 1B, 5 and 6 require 2 x VHD3200 amps
Please refer to the VHD2000 or the EPAK2500/R manuals for further information on setting up these systems.
Sub-A Out
2 x VHD2.16 (1x2.15)
2 x VHD4.18 2 x VHD2.16 (1x2.15) 2 x VHD2.16 (1x2.15) 4 x VHD2.16 (2x2.15) 4 x VHD2.16 (2x2.15)
Sub-B Out
1 x VHD2.21 2 x VHD4.18 2 x VHD1.21 2 x VHD4.18 4 x VHD4.18 4 x VHD1.21
5
|
VHD3200 AMPLIFIER / CONTROLLER
SPECIFICATIONS
Output Channels
Number of Channels Out. Power 4Ω - 1 channel / 2 channels loaded Out. Power 8Ω - bridged
Low Frequency Amplier Specication
Type
Distortion Operating Bandwidth
Signal Input
Input Sensitivity 1.0V RMS Input Impedance Signal Output
2 1600W / 1600W (RMS) 3200W (RMS)
High eciency, Low frequency, Current-enhancing switch mode <0.05% 20Hz ÷ 100Hz
20kΩ (balanced) Main Through OUT
Speaker Output
Speaker Output
- / 2x EP4 (1x bridge)
Features
System setup
Limiter / Short protection
Power
Power Connector Operating Voltage 115V / 230V / 250V Operating Voltage Range Recommended Amperage Soft Start Protection Cooling
2x Neutrik PowerCon®
100÷120V@60Hz | 205÷240V@50Hz | 225÷260V@50Hz 2 x 20A 115V YES Thermal breaker 2x temperature controlled fans
2 x 10A 230V| 2 x 10A 250V
Physical Dimensions
Height Width Depth 495mm (19.5") Weight
177.8mm (7.0") 483mm (19.0")
35kg (88lbs)
The future of sound. Made perfectly clear.
At KV2 Audio our vision is to constantly develop technologies that eliminate distortion and loss of information providing a true dynamic representation of the source.
Our aim is to create audio products that absorb you, place you within the performance and deliver a listening experience beyond expectation.
KV2 Audio, Nádražní 936, 399 01 Milevsko, Czech Republic Tel. +44(0)1423 816868
www.kv2audio.com
KVV120014-00-03-0
Loading...