KV2 Audio SD8 User Manual

SD8
User Guide
The future of sound.
+ 3
+48V
30
­8
­GAIN
14
-
dB
+ 3
+48V
30
-
8
­GAIN
14
-
dB
+ 3
+48V
30
-
8
­GAIN
14
-
dB
+ 3
+48V
30
-
8
­GAIN
14
-
dB
+ 3
+48V
30
-
8
­GAIN
14
-
dB
+ 3
+48V
30
-
8
­GAIN
14
-
dB
+ 3
+48V
30
-
8
­GAIN
14
-
dB
+ 3
+48V
30
-
8
­GAIN
14
-
dB
8
20dB
-
CHANNEL
0dB +30dB
7
20dB
-
CHANNEL
0dB +30dB
6
20dB
-
CHANNEL
0dB +30dB
5
20dB
-
CHANNEL
0dB + 30dB
4
20dB
-
CHANNEL
0dB +30dB
3
20dB
-
CHANNEL
0dB +30dB
2
20dB
-
CHANNEL
0dB + 30dB
1
20dB
-
CHANNEL
0dB +30dB
Made perfectly clear.
At KV2 Audio our vision is to constantly develop technologies that eliminate distortion and loss of information providing a true dynamic representation of the source.
Our aim is to create audio products that absorb you, place you within the performance and deliver a listening experience beyond expectation.
ON
OFF
POWER
Safety Instructions
IMPORTANT SAFETY INSTRUCTIONS
Observe all instructions and follow warnings marked on the equipment and in the user’s manual. Connect the equipment only to a source of proper mains voltage. Do not attempt to switch on any equipment that has been dropped, that is damaged, or has had liquid penetration, or if malfunctions have occurred and their nature requires a repair action. The supply cable shall be made by a person having proper qualications.
WARNING
The equipment is designed in Class I and shall be connected to a wall socket having
SD8
protective earthing. The mains plug and supply cable shall remain easy accessible, as this is used for disconnection of the equipment from the supply source if necessary. Never interrupt earthing due to safety reasons. Do not place the equipment close to heating bodies or other sources of heat and protect it against direct sunlight. The equipment must not come into contact with open ames. Ventilation of the equipment must not be obstructed by covering of ventilation openings. The equipment must not be exposed to dripping or splashing liquid or water and excessive humidity. Any object lled with any liquid shall not be placed on the equipment.
The triangle with a symbol of a lightning marks parts of the equipment under life jeopardizing voltage, whose values may cause an injury from electric shock.
The symbol indicating that the equipment is manufactured in compliance with EU standards.
The triangle with a symbol of an exclamation mark in the text marks important instructions for operation, setting and maintenance.
BASIC DESCRIPTION
Safety Instructions
The SD8 is an 8-channel microphone preamplier combined with a line amplier. It is designed for primary processing of microphone signals. Impedances of the SD8 inputs are properly adapted to most of the microphones used, the signals are amplied and the inputs, thanks to their low imped­ance - (50 ohms) can drive, without any loss, long symmetrical lines to the mixers - (up to 500m). It is suitable to place the SD8 directly on the stage, close to the active microphones as practical, as most microphones cannot provide loss-free excitation of long cables. 48V phantom supply is available to supply condenser microphones. Each channel is equipped with two identical outputs that can be used for connection of a main mixer and monitoring desk, recording device, etc.
2
Description
BLOCK DIAGRAM (ONE CHANNEL) INPUT / OUTPUT CONNECTORS PINS
+48V
PA D
GAIN OUTPUT LEVEL
-
14
-8-
30
+ 3
dB
-20dB
IN OUT
+
-
OUT
FRONT PANEL DESCRIPTION
Mains voltage indication
Output level indication
dB
-
14
-8-
30
dB
+ 3
Phantom voltage indication
OutputInput
SD8
Pin 1 - Ground
Pin 2 - Signal (+)
Pin 3 - Signal (-)
Case - Earth (AC) ground and chassis
POWER
ON
OFF
REAR PANEL DESCRIPTION
Channel marking
Input connector
Output connector 1
Output connector 2
GAIN
+48V
0dB +30dB
CHANNEL
-
20dB
1
Mains switch
1
IN
OUT
OUT
Phantom voltage switch
Gain adjustment
0dB
-20dB Input sensitivity reduction
WARNING:
TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE THIS PANEL OR ANY ATTACHED COMPONENTS. NO OPERATOR SERVICE­ABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED PERSONNEL. TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE.
Mains connector
Description
3
y
p
p
p
p
g
g
g
g
SD8 SPECIFICATIONS
System Acoustic Perfomance
-1dB Response 6Hz - 500kHz
namic Range >120dB
D Total Harmonic Distortion <0.0005%
Output Channels
Max. Out Max. Output Current 450mA
Signal Input
In Input Impedance 20kΩ Mic in
Signal Output
Output channels 8x2 Out
Features
Indicators Si
ut Voltage 14V / 7V (50Ω) RMS
ut Channels 8x
ut 0 - +30dB Gain, pad -20dB
ut Impedance 50Ω
nal bar, Phantom
Power Requirements
Power Connector IEC 320 Operatin Protection T 315mA(115V), T160mA(240V)
Physical Dimensions
Hei Width 483mm (19.0") Depth 177.8mm (7.0") Wei
Voltage 100-120V @ 60Hz | 230-250V @ 50Hz
ht 89.0mm (3.0")
ht 5.5kg (12.1lbs)
The future of sound. Made perfectly clear.
At KV2 Audio our vision is to constantly develop technologies that eliminate distortion and loss of information providing a true dynamic representation of the source.
Our aim is to create audio products that absorb you, place you within the performance and deliver a listening experience beyond expectation.
KV2 Audio, Nádražní 936, 399 01 Milevsko, Czech Republic T +44(0)1423 816868 F +44(0)1423 816869
www.kv2audio.com
KVV120013-00-03-0
Loading...