Kussmaul Electronics 091-9-12V-AD User Manual

INSTRUCTION MANUAL
AUTO DRAIN
AUTOMATIC MOISTURE DRAIN
FOR THE 091-9-12V AUTO PUMP
File: IM_091-9-131_reva.indd Rev: A Revised By: MFG Date: 10-28-2013
170 Cherry Avenue West Sayville, NY 11796 www.kussmaul.com
MODEL #: 091-9-131
INPUT: 12 Volts DC
1 YEAR WARRANTY
device for more information
Ph: 800-346-0857
Fax: 631-567-5826
sales@kussmaul.com
INTRODUCTION
The Auto Drain system consists of a 12 volt normally open solenoid, a filter and assorted fit­tings. Designed to work with the Auto Pump 12V, the solenoid bleeds the filter bowl when the pump is not running. As soon as the pressure switch turns on the compressor, the solenoid is energized and the bleed is closed. A check valve is installed on the Auto Drain assembly to seal off the vehicle’s air pressure when the bleed valve opens.
NOTES AND COMPONENTS
I. COMPONENTS OF THE AUTO DRAIN ASSEMBLY
ITEM QUANTITY PART NUMBER DESCRIPTION
1. 1 A2211-S18 Solenoid Valve, 12 volts D.C., normally open
2. 1 F5044-02-DH-Z310 Filter, with metal bowl
3. 1 216P-2 Nipple, 1/8 NPT Close
4. 1 219-P-2 Plug, 1/8 NPT
5. 1 219-P-4 Plug, 1/4 NPT
6. 2 1202P4-4 Street elbow, 1/4 NPT
7. 1 PL1/4-NIUT Elbow, 1/8 NPT, male - 1/4 tube
8. 1 CMMQ20-B Check Valve, 1/4 NPT male -1/4 NPT male
9. 1 PLB101-4 Tee, brass, 1/4 NPT
10. 1 PVC-1/4 Sleeving, 1/4” PVC, 11 inches
11. 2 PLB112-4 Nipple, 1/4 NPT, Close
12. 1 PVC-105-5CL #5 Tubing, 24” Clear
II. NOTES
1. Install pressure switch on Auto Drain before installing Auto Drain on pump.
2. It may be necessary to slightly rotate solenoid valve by turning Filter Bowl to clear pressure switch when installing.
3. Remember to tighten Filter Bowl rmly after Pressure Switch is installed.
170 Cherry Avenue West Sayville, NY 11796 www.kussmaul.com
Ph: 800-346-0857
Fax: 631-567-5826
sales@kussmaul.com
2
INSTALLATION INSTRUCTIONS
I. WIRING OF THE AUTO DRAIN TO THE AUTO PUMP 12V
1. Connect the Auto Drain solenoid wires to output terminals of pressure switch. These are the same terminals that supply power to the Auto Pump 12V motor.
2. The Auto Drain is now properly connected. Test by bleeding system pressure to start Auto Pump 12V and note that when pump shuts down, air and moisture will bleed out of drain tube.
3. Position drain tube to direct moisture to exterior of vehicle.
II. WIRING DIAGRAM
170 Cherry Avenue West Sayville, NY 11796 www.kussmaul.com
Ph: 800-346-0857
Fax: 631-567-5826
sales@kussmaul.com
3
INSTALLATION RECORD
DATE INSTALLED _______________________________________________________
INSTALLED BY _________________________________________________________
VEHICLE IDENTIFICATION _______________________________________________
VEHICLE OWNER _______________________________________________________
WARRANTY POLICY
All products of Kussmaul Electronics are warranted to be free of defects of material or workmanship. Liability is limited to repairing or replacing at our factory, without charge, any material or defects which become apparent in normal use within 1 year from the date the equipment was shipped. Equipment is to be returned, shipping charges prepaid and will be returned, after repair, shipping charges paid.
Kussmaul Electronics shall have no liability for damages of any kind to associated equipment arising from the installation and/or use of the Kussmaul Electronics products. The purchaser, by the acceptance of the equipment, assumes all liabil­ity for any damages which may result from its installation, use or misuse, by the purchaser, his or its employees or others.
170 Cherry Avenue West Sayville, NY 11796 www.kussmaul.com
Ph: 800-346-0857
Fax: 631-567-5826
sales@kussmaul.com
4
Loading...