AUTO CURRENT F-A
D.C. CURRENT SENSOR WITH AUX. INPUT
INSTALLATION INSTRUCTIONS
S1
S
Chassis
Ground
2
1
Chassis
Ground
V
2
D
N
I
A
D
G
Chassis
Ground
Indicator
Lamp
U
X
The Auto Current F-A detects current and closes a
switch when the sensed current flows, to provide a
remote indication. An electronic frasher interrupts the
indicator output approximately once per second to
Compartment
Lights
Loads
Loads
Auxiliary Input
Switch
SENSOR
Chassis
Ground
SWITCH
Door
switch
Door
switch
Chassis
Ground
Chassis
Ground
provide a flashing indication.
An Auxiliary input permits operating the flasher from
other grounding switches. Any number of switches
may be connected in parallel to terminal 4 to operate
the Indicator Lamp.
S1 S2AUXGD+12V IND
SCHEMATIC
Warning Indicator is limited to 5 amperes maximum.
ORDERING INFORMATION
MODEL
NUMBER
091-22F-A
091-22F-A-6
RESIST
OHMS
.01
.2
MIN. OPER.
AMPS
1.0
0.10
KUSSMAUL ELECTRONICS CO., INC.
170 CHERRY AVE., WEST SAYVILLE, N.Y. 11796
TEL: in NY 631-567-0314 TOLL FREE: 800-346-0857 FAX: 631-567-5826
TIMER
MAX. OPER.
AMPS
30
4
RELAY
SWITCH
RATING 12V
5 AMP
5 AMP
October 20, 2006