Kussmaul Electronics 091-22-A User Manual

AUTO CURRENT A
D.C. CURRENT SENSOR WITH AUX. INPUT
INSTALLATION INSTRUCTIONS
S1
S
Chassis Ground
2
1
Chassis Ground
V
2
D
N
I
A
D G
Chassis Ground
Indicator Lamp
U
X
The Auto Current A detects current and closes a
remote indication. The current detected may be from
compartment lights as illustrated or from any other
D.C. Load in the range.
Compartment Lights
Loads
Loads
Auxiliary Input Switch
SENSOR
Chassis Ground
SWITCH
Door switch
Door switch
Chassis Ground
Chassis Ground
An Auxiliary input permits opera ting the output relay
from other grounding switches. Any number of switches
may be connected in parallel to terminal 4 to operate
the Indicator Lamp.
S1 S2AUXGD+12V IND
SCHEMATIC
Warning Indicator is limited to 5 amperes maximum.
KUSSMAUL ELECTRONICS CO., INC.
170 CHERRY AVE., WEST SAYVILLE, N.Y. 11796
TEL: in NY 631-567-0314 TOLL FREE: 800-346-0857 FAX: 631-567-5826
RELAY
July 25, 2007