INSTALLATION INSTRUCTIONS
Model 091-18-098 DYNAMIC DISCONNECT
The Model 091-18-098 Dynamic Disconnect is a coupling device wired between an Auto Eject and the vehicle and serves to only connect the A.C. power after the plug has been inserted into the Auto Eject. Upon vehicle startup the Dynamic Disconnect opens the load circuit before ejecting the plug. By providing the time delays on both application and removal of power, no arcing can occur at the connector.
Note:
A.C. power must be present at the shore line connector
in order to operate the Dynamic Disconnect.
Installation is simple, mount the Dynamic Disconnect at some convenient location, protected from the weather. Wire in accordance with the diagram below.
RED LED
Indicates Auto Eject
solenoid is energized
LINE
120 VOLTS FROM
AUTO EJECT
NEUTRAL
J2
2
1
2 AMP FUSE
TO VEHICLE
120 V LOADS
N.C. N.O.
COM.
J1
1
2
34
GREEN LED
Indicates Dynamic Disconnect
5
relay is energized
AUTO EJECT
TO VEHICLE
120 VOLT LOADS
+12V FROM
STARTER
+12V
SOLENOID
November 12, 2004
SINCE 1967, DESIGNERS OF INNOVATIVE PRODUCTS
KUSSMAUL ELECTRONICS COMPANY, INC.
170 CHERRY AVENUE, WEST SAYVILLE, NEW YO RK, 11796-1221 USA
TEL. In NY: TOLL FREE: FAX:
631 567-0314 800 346-0857 631 567-582