Kussmaul Electronics 091-167-12 User Manual

Page 1
6
INSTALLATION INSTRUCTIONS
The 091-167-12, Load Manager 1HP is a small waterproof assembly that monitors a D.C. voltĀ­age and operates a relay when the voltage drops below its set point.
With the engine running and battery voltage above 12.8 volts, the relay is energized and power is supplied to the loads.
With the engine stopped and continuous loads that reduce the battery below +11.5 volts, the relay will drop out and prevent complete discharge of the battery. The relay remains de-enerĀ­gized until the battery voltage returns to +12.8 volts or higher.
An optional starter input prevents the relay from dropping out during the cranking cycle if the voltage prior to cranking was sufficient (+11.5 volts).
Note: the starter input is not required for normal operation if cranking shutdown protection is not required.
Size Fuse
for 25% Higher
Than Actual
Load
From +12V
Battery
Fuse
75 Amp
Relay
Radio &
Computer
Loads
4
321
+12V From
Starter
(optional)
Specifications:
Input: Relay Pull-In: Relay Drop-Out: Relay Contact Rating:
SINCE 1967, DESIGNERS OF INNOVATIVE PRODUCTS
+12 Volts Nominal
12.8 +/- 0.1 Volts
11.5 +/- 0.1 Volts 75 Amperes D.C.
KUSSMAUL ELECTRONICS COMPANY, INC.
170 CHERRY AVENUE, WEST SAYVILLE, NEW YORK, 11796-1221 USA
TEL. In NY: TOLL FREE: FAX:
631 567-0314 800 346-0857 631 567-582
May 24, 2007