Kussmaul Electronics 091-103-012 User Manual

INSTALLATION INSTRUCTIONS
TIME DELAY RELAY - DODO
DELAY ON DROP-0UT
Model 091-103-012
The Model 091-103-012 Time Delay Relay operates in a +12 volt electrical system. The relay contacts transfer immediately upon the application of an input signal and remain closed after the signal is removed for the length of the specified time interval. The range of output times as well as the factory setting is shown in the table. The output relay contacts are capable of switching 30 amperes.
An adjustment is provided to vary this time at installation. See figure 1. An LED indicator adjacent to the terminal strip is lit whenever the relay is energized. Figure 2 illustrates the Time Delay Relay applied to a typical lighting circuit.
Time Delay Adjust
Model Tmin Tmax Tset
A 1.25 min 6 min 3 min
B6min27min15min
C 12min 60min 30min
D 4 sec 15 sec 10 sec
E 2 sec 3.3 sec 2 sec
RUN
NOTE: The run/calibrate switch speeds
up the time delay interval by a factor of 128.
CALIBRATE
1 second in the calibrate position is equal to 128 seconds in the run position
N.C. N.O.
COM.
LED illuminates when relay is energized
+12 volts
Ground
2
1
3
LIGHTS WILL REMAIN ILLUMINATED FOR THE TIME DELAY
INTERVAL AFTER THE SWITCH IS TURNED OFF
Figure 2
TYPICAL INSTALLATION IN A LIGHTING CONTROL CIRCUIT
SINCE 1967, DESIGNERS OF INNOVATIVE PRODUCTS
KUSSMAUL ELECTRONICS COMPANY, INC.
170 CHERRY AVENUE, WEST SAYVILLE, NEW YORK, 11796-1221 USA
JANUARY 9, 2002
Lighting Control Switch
Lighting
Circuit
+12 V FROM LIGHTING CIRCUIT BREAKER
631-567-5826,FAX:631-567-0314,TEL:
Loading...