Kussmaul Electronics 091-100-012 User Manual

INSTALLATION INSTRUCTIONS
TIME DELAY RELAY - DOPI
DELAY ON PULL-IN
Model 091-100-012
The Model 091-100-012 Time Delay Relay operates in a +12 volt electrical system. The relay contacts transfer at some time after the application of an input signal to terminal 3. The input signal may be either +12 volts or a ground as selected by the slide switch adjacent to the terminal strip. An output relay has contacts capable of switching 30 amperes. A +12 volt power and ground line are required to operate the time delay circuits. In operation the signal input to the time delay relay is applied when the first load is energized. At the delay interval later, the relay closes to operate the second load. The time delay is factory set for either 5 or 60 seconds depending on the model. An adjustment is provided to reduce this or increase it to the values shown in the table. See figure 1 for time adjustment. Figure 2 illustrates the Time Delay Relay applied to a High Idle/Hydraulic pump control.
+12 V FROM PUMP CONTROL
+12 volts
Ground
TIME DELAY
Specification Model A Model B
Factory Set 5 sec 60 sec
MinTime(CW) 2.4sec 11sec
Max Time (CCW) 28 sec 120 sec
N.C. N.O.
COM.
Gnd
1
+
2
3
Time delay
Adjust
Figure 1
Note: For grounding signal inputs
SIGNAL POLARITY INPUT SELECTOR
Figure 2
move signal polarity input selector switch to the left
+12 VOLTS WHEN SYSTEM GOES INTO HIGH IDLE
HYDRAULIC PUMP CONTROL
HIGH IDLE
SYSTEM
TYPICAL INSTALLATION WITH HIGH IDLE PRECEDING HYDRAULIC PUMP STARTUP