KUSSMAUL 091-55-194B-24-20A, 091-55-194C-24-45A Instruction Manual

Page 1
INSTRUCTION MANUAL
SUPER AUTO EJECT DELUXE COVER
WITH DIGITAL DISPLAY
194B-24: 20A, 194C-24: 45A
File: IM_091-55-194X-24-XXX Rev: A Revised By: PSS/JRN Date: 06-12-2018
170 Cherry Avenue West Sayville, NY 11796 www.kussmaul.com
3 YEAR WARRANTY
Ph: 800-346-0857
Fax: 631-567-5826
sales@kussmaul.com
Page 2
INTRODUCTION
The new Super Auto Eject Deluxe Cover incorporates two products into one easy to install package. The Deluxe Cover features a remotely mounted volts and amps digital display. Two 3-digit LED dis­plays are used to display the Kussmaul battery charger output voltage and current. Two individual LEDs are used to provide additional battery charger status such as: HIGH voltage, LOW voltage, current-limit, and over-current.
The new lid design provides for 180-degree motion. This all-in-one package can be easily installed into existing and new Auto Eject installs.
FEATURES
I. NEW COVER DESIGN
• Incorporates Auto Eject cover and Digital Display into one product
• Lid on cover opens 180-degrees to prevent beakage
• Two numerical LEDs display Auto Charger Volts and Amps output
• Includes rear mounted premolded rubber gasket for extra protect from the elements
II. INCORPORATED LED NUMERICAL DISPLAYS
When used with Kussmaul Auto Charger, two numerical LED displays output the chargers voltage and ampage. These easy to read displays provide immediate charger output conditions.
III. VOLTS & AMPS LED STATUS INDICATOR VOLTS LED:
• Blinking RED: HIGH voltage or LOW voltage condition
• Blinking GRN: Charging
• Solid GRN: Charged
AMPS LED:
• Blinking RED: Current-limit exceeded
• Solid RED: Current-limit
• Solid GRN: Output greater than 5 amps
INSTALLATION INSTRUCTIONS
I. INSTALLATION
1. Follow instructions for installing the Auto Eject.
2. Place the template in position and center punch in 6 places, see Figure 1: Hole Template.
3. Drill 4 mounting holes, 3/16” diameter, one 1-3/4” clearance hole for the Super Auto Eject, and one 13/32 hole for the indicator wiring cable.
II. HOLE TEMPLATE: Figure 1 Note: When printing this page use the print setting “Actual Size”, otherwise template may not print
to scale.
2
Page 3
INSTALLATION INSTRUCTIONS
13
" THRU ALL
32
2.950
1.625
4X
3
" THRU ALL
16
0
.938
0
.938
1.625
Figure 1: Hole Template
170 Cherry Avenue West Sayville, NY 11796 www.kussmaul.com
3
1
"
4
THRU ALL
sales@kussmaul.com
Ph: 800-346-0857
Fax: 631-567-5826
3
Page 4
INSTALLATION INSTRUCTIONS
III. MOUNTING
1. Rubber gasket is premounted to the Deluxe Cover.
2. Install as shown in Figure 2: Cover and Gasket Mounting.
3. Insert (4) 8-32 X 7/8”, PHILLIPS PANHEAD screws.
IV. COVER & GASKET MOUNTING: Figure 2
8-32 X 7/8" PHILLIPS PANHEAD MOUNTING SCREWS (4)
6.21
091-055-207 GASKET
TRUCK BODY
170 Cherry Avenue West Sayville, NY 11796 www.kussmaul.com
Ph: 800-346-0857
Fax: 631-567-5826
sales@kussmaul.com
4
Page 5
WIRING DIAGRAM
REMOTE D
ISPLAY
4
3
2
1
4 - GREEN 20AWG 3 - WHITE 20AWG 2 - BLACK 20AWG 1 - RED 20AWG
TYPICAL REMOTE INTERFACE LOCATED ON CHARGER
GASKET COVER with INDICATOR
16-ft cable, included
CABLE
OUTLINE DRAWING
3.51
8-32 X 7/8" PHILLIPS PANHEAD MOUNTING SCREWS (4)
16 FT
6.21
091-055-207 GASKET
TRUCK BODY
1.24
170 Cherry Avenue West Sayville, NY 11796 www.kussmaul.com
Ph: 800-346-0857
Fax: 631-567-5826
sales@kussmaul.com
5
Page 6
SPECIFICATIONS
Input Voltage: 12 to 30 VDC ( 32V absolute) Input Current: 50mA,Max Temperature Range: -40F to 120F Volts and Amps Meter: +/- 1% Current-limit: 194B-24: 20A, 194C-24: 45A High Voltage: >29.6 VDC Charged: 26.3 - 29.6 VDC Charging: 26.2 - 26.6 VDC Low Voltage: <26.6 VDC Cord: 20 AWG, 4-conductor Cord Type: 16 feet Warranty: 3 year
INSTALLATION RECORD
DATE INSTALLED _______________________________________________________ INSTALLED BY _________________________________________________________ VEHICLE IDENTIFICATION _______________________________________________ VEHICLE OWNER _______________________________________________________
WARRANTY POLICY
All products of Kussmaul Electronics are warranted to be free of defects of material or workmanship. Liability is limited to repairing or replacing at our factory , without charge, any material or defects which become apparent in normal use within 2 years from the date the equipment was shipped. Equipment is to be returned, shipping charges prepaid and will be returned, after repair, shipping charges paid.
Kussmaul Electronics shall have no liability for damages of any kind to associated equipment arising from the installation and/or use of the Kussmaul Electronics products. The purchaser , by the acceptance of the equipment, assumes all liabil­ity for any damages which may result from its installation, use or misuse, by the purchaser, his or its employees or others.
170 Cherry Avenue West Sayville, NY 11796 www.kussmaul.com
Ph: 800-346-0857
Fax: 631-567-5826
sales@kussmaul.com
6