INTRODUCTION
The new Super Auto Eject Deluxe Cover incorporates two products into one easy to install package.
The Deluxe Cover features a remotely mounted volts and amps digital display. Two 3-digit LED displays are used to display the Kussmaul battery charger output voltage and current. Two individual
LEDs are used to provide additional battery charger status such as: HIGH voltage, LOW voltage,
current-limit, and over-current.
The new lid design provides for 180-degree motion. This all-in-one package can be easily installed
into existing and new Auto Eject installs.
FEATURES
I. NEW COVER DESIGN
• Incorporates Auto Eject cover and Digital Display into one product
• Lid on cover opens 180-degrees to prevent beakage
• Two numerical LEDs display Auto Charger Volts and Amps output
• Includes rear mounted premolded rubber gasket for extra protect from the elements
II. INCORPORATED LED NUMERICAL DISPLAYS
When used with Kussmaul Auto Charger, two numerical LED displays output the chargers voltage
and ampage. These easy to read displays provide immediate charger output conditions.
III. VOLTS & AMPS LED STATUS INDICATOR
VOLTS LED:
• Blinking RED: HIGH voltage or LOW voltage condition
• Blinking GRN: Charging
• Solid GRN: Charged
AMPS LED:
• Blinking RED: Current-limit exceeded
• Solid RED: Current-limit
• Solid GRN: Output greater than 5 amps
INSTALLATION INSTRUCTIONS
I. INSTALLATION
1. Follow instructions for installing the Auto Eject.
2. Place the template in position and center punch in 6 places, see Figure 1: Hole Template.
3. Drill 4 mounting holes, 3/16” diameter, one 1-3/4” clearance hole for the Super Auto Eject, and
one 13/32 hole for the indicator wiring cable.
II. HOLE TEMPLATE: Figure 1
Note: When printing this page use the print setting “Actual Size”, otherwise template may not print
to scale.
2

INSTALLATION INSTRUCTIONS
13
" THRU ALL
32
2.950
1.625
4X
3
" THRU ALL
16
0
.938
0
.938
1.625
Figure 1: Hole Template
170 Cherry Avenue
West Sayville, NY 11796
www.kussmaul.com
3
1
"
4
THRU ALL
sales@kussmaul.com
Ph: 800-346-0857
Fax: 631-567-5826
3

INSTALLATION INSTRUCTIONS
III. MOUNTING
1. Rubber gasket is premounted to the Deluxe Cover.
2. Install as shown in Figure 2: Cover and Gasket Mounting.
3. Insert (4) 8-32 X 7/8”, PHILLIPS PANHEAD screws.
IV. COVER & GASKET MOUNTING: Figure 2
8-32 X 7/8"
PHILLIPS PANHEAD
MOUNTING SCREWS (4)
6.21
091-055-207
GASKET
TRUCK BODY
170 Cherry Avenue
West Sayville, NY 11796
www.kussmaul.com
Ph: 800-346-0857
Fax: 631-567-5826
sales@kussmaul.com
4

WIRING DIAGRAM
REMOTE
D
ISPLAY
4
3
2
1
4 - GREEN 20AWG
3 - WHITE 20AWG
2 - BLACK 20AWG
1 - RED 20AWG
TYPICAL REMOTE INTERFACE LOCATED ON CHARGER
GASKET
COVER with
INDICATOR
16-ft cable, included
OUTLINE DRAWING
3.51
8-32 X 7/8"
PHILLIPS PANHEAD
MOUNTING SCREWS (4)
16 FT
6.21
091-055-207
GASKET
TRUCK BODY
1.24
170 Cherry Avenue
West Sayville, NY 11796
www.kussmaul.com
Ph: 800-346-0857
Fax: 631-567-5826
sales@kussmaul.com
5

SPECIFICATIONS
Input Voltage: 12 to 30 VDC ( 32V absolute)
Input Current: 50mA,Max
Temperature Range: -40F to 120F
Volts and Amps Meter: +/- 1%
Current-limit: 194B-24: 20A, 194C-24: 45A
High Voltage: >29.6 VDC
Charged: 26.3 - 29.6 VDC
Charging: 26.2 - 26.6 VDC
Low Voltage: <26.6 VDC
Cord: 20 AWG, 4-conductor
Cord Type: 16 feet
Warranty: 3 year
INSTALLATION RECORD
DATE INSTALLED _______________________________________________________
INSTALLED BY _________________________________________________________
VEHICLE IDENTIFICATION _______________________________________________
VEHICLE OWNER _______________________________________________________
WARRANTY POLICY
All products of Kussmaul Electronics are warranted to be free of defects of material
or workmanship. Liability is limited to repairing or replacing at our factory , without
charge, any material or defects which become apparent in normal use within 2
years from the date the equipment was shipped. Equipment is to be returned,
shipping charges prepaid and will be returned, after repair, shipping charges paid.
Kussmaul Electronics shall have no liability for damages of any kind to associated
equipment arising from the installation and/or use of the Kussmaul Electronics
products. The purchaser , by the acceptance of the equipment, assumes all liability for any damages which may result from its installation, use or misuse, by the
purchaser, his or its employees or others.
170 Cherry Avenue
West Sayville, NY 11796
www.kussmaul.com
Ph: 800-346-0857
Fax: 631-567-5826
sales@kussmaul.com
6