Kuppersberg TS 69 X User Manual

TECHNICAL PASSPORT
ПАСПОРТ ТЕХНИЧЕСКОГО ИЗДЕЛИЯ
TG 699, TG 69, TS 69, TS 79, TG 79, TG 799, TS 63, TS 39, TG 39, TS 99, TG 99, FQ4TG, FV3TG, FQ3TG, FQ7TG, TS63E, TG49
GAS HOB
ГАЗОВЫЕ ВАРОЧНЫЕ ПОВЕРХНОСТИ
Gas hob
CONTENTS
1. APPEAL TO THE CUSTOMER .......................................................................................... 3
2. CHILDREN’S SAFETY ..........................................................................................................3
3. IMPORTANT SAFETY INSTRUCTION ......................................................................... 3
4. ENVIRONMENTAL PROTECTION ................................................................................. 5
5. BEFORE USING YOUR APPLIANCE FOR THE FIRST TIME ............................ 6
6. MAINTENANCE AND INSTALLATION MANUAL .................................................. 7
6.1. SAFETY INSTALLATION ......................................................................................... 7
6.2. INSTALLING THE APPLIANCE ............................................................................ 8
6.3. ELECTRICAL CONNECTION .................................................................................. 10
6.4. GAS CONNECTION .................................................................................................... 10
6.5. ADJUSTMENT OF HOB PER GAS TYPES ........................................................ 11
6.6. STARTING THE APPLIANCE .................................................................................12
6.7. TECHNICAL CHARACTERISTIC AND DRAWINGS ...................................... 13
6.8. TECHNICAL INFORMATION ON GAS BURNERS ....................................... 14
7. CONTROL TYPES AND USE ............................................................................................. 15
7.1. CONTROL PANEL ........................................................................................................ 15
7.2. BASIC SETTINGS ........................................................................................................15
7.2.1. FOR GAS BURNERS ................................................................................................ 15
7.2.2. FOR HOT-PLATE BURNERS ............................................................................... 16
7.3. BASIC FUNCTION ....................................................................................................... 16
8. MAINTENANCE AND CLEANINGS ............................................................................... 19
9. TROUBLESHOOTING .......................................................................................................... 20
2
ENGLISH TECHNICAL PASSPORT
Gas hob
APPEAL TO THE CUSTOMER
Our Valued Customer,
Thank you for your purchase of our
product.
Please read all instructions and warnings in this manual carefully. This manual includes the important information about safe installation, usage and maintenance and the required warnings for your utilization of your equipment.
Please keep this manual at a safe and easily accessible place to be used as future reference.
The Producer may not be held liable for the losses to human, environment or other materials arisen from the faulty use of the equipment arisen from the translation or printing of this manual.
2. CHILDREN’S SAFETY
 The exposed parts of the product shall be heated during and after the use; the children should be kept away.
 Do not place any object on the unit that the children may reach.
 Packaging materials may be dangerous for children. Keep the packaging materials in a place that the children may not reach or classify and recycle them as per the waste instructions.
 If constant supervision may not be provided the children under age 8 shall be kept away of the unit.
 This unit may be used by children over 8 years old and the persons with lack of physical, hearing or mental abilities or lack of experience and information, subject to guidance and supervision or utilization of the unit safely and recognition of the dangers.
 Children should not play with the unit.
 Cleaning and maintenance of the unit should not be conducted by the children without supervision.
3. IMPORTANT SAFETY INSTRUCTION
This device is produced for domestic
use. Our  rm is not liable for any losses
or damages which may occur due to wrong or faulty installation.
Although this is a simple use product, we recommend you to read this manual carefully. In this sense, you may get best performance from your device and protect yourself and your surrounding from the possible dangers.
Please consider the following warnings in order to minimize the risks which may be experienced by you in utilization of the devices such as electric shock, circumstances which may cause losses/ damages to people. 3
 Device is set to 220 -240 volt.  WARNING: The equipment and
its accessible parts are hot during use.
3
Gas hob
 Best care should be used to avoid
contacting with the heating elements.
 WARNING: Cooking with vegetable oil or fat without required care may be dangerous and may cause
 re.
 Do not attempt to extinguish
any  re with water, the circuit of the equipment is closed and then the  ame is covered with a cover or  ame blanket.
 WARNING: Fire Danger: Do not store materials on cooking surface.
 The accessible parts may be hot during utilization.
 Do not ever clean your hob by using steam cleaners.
 The equipment is designed to be operated with an external timer or a separate remote control.
 Do not use the unit in circumstances affecting your judgment such as being drank or drugged.
 Since your device has grounding plug your wall socket should also be grounding type.
 Use utmost care to prevent your device’s electrical cable through hot areas.
 Use care that the gas hose will be regulations in law institute stamped, not be laid through hot areas, and it should be checked with soap bubble whether any gas leakage exists.
 Use clamp to tighten the gas hose after connecting it to the head of the hose. Control whether there is any gas leakage exists by using soap bubble.
 Note that the LPG hoods should have regulations in law institute stamp and 300 mmSS (30mbar) of outlet pressure.
 Natural gas pressure is 200 mmSS (20mbar). Please consult the authorized service for conversion to natural gas or LPG.
 Note: Usage of the gas baking products shall cause heat and steam formation at the places of existence. Be sure that your kitchen is ventilated well. Keep the natural ventilation outlets open or install a mechanical ventilation product (hood, aspirator).
NOTE:
Burners burning of setting can be
done between large and between.
GENERAL SAFETY WARNINGS
 Since this unit was produced for domestic use, it is not suitable for commercial and industrial use. It is dangerous and inappropriate to use it for any other purpose (e.g. heating a room).
 Do not allow laying of the gas hose and electric cord from the heated part of the unit.
 Keep any  aming, explosive and ignition materials from your device.
 Do not change the place of your device when working and/ or it is hot.
 When you do not use your hob, close the feeding valve after making all switches to “OFF” position.
4
ENGLISH TECHNICAL PASSPORT
Gas hob
 Do not let your hob in operation without supervision control it with frequently.
 Take out the plug from the wall socket during handling, cleaning or maintenance of the unit.
 Do not ever attempt to remove the cable from the wall socket by handling the cable.
 Do not touch or operate the unit when your hands or feet are wet.
 For the hobs supplied with glass: if the glass of your hob will crack and/ or break remove the device from the wall socket.
 Do not use pans transferring the excessive heat to the glass.
 Place the pan right in the middle of the burner.
 Do not place any sharp object on the hob.
 Keep the pan on the hob carefully and avoid dropping it.
 The shapes in this guide are schematic and may not be exact match of your product. The values stated on the marking on the unit or other printed documents given with the unit are the values obtained at the laboratory pursuant to the applicable standards. Such values may be changed as per the usage and environment conditions of the unit.
 Do not heat the closed cans and glass jars. The pressure which may occur in such containers may cause explosion.
 Since the edges of the product will be hot do not place explosive or combustibles near the unit.
 Do not place the empty pans and containers on the operating hob eyes. The glass surface may be damaged.
 No plastic and aluminum container is allowed over the unit since it might be hot.
4. ENVIRONMENTAL PROTECTION
This device is subject to 2002/96/ EC WEEE (Waste Electric and Electronic Equipment) as per the applicable directives of Europe. Before disposal of the device, you need to prevent negative results to human and environment. Otherwise it would be incompliant waste. This symbol indicates that the unit should not be disposed as domestic waste rather it should be returned to some electronic wastes collection center. The disposal of the product should be conducted as per the local environmental legislation. You may obtain detail information on disposal, reuse and recycling of the product.
It is suitable with the applicable regulations of WEEE.
5
Gas hob
This symbol indicates that the unit should not be disposed as domestic waste rather it should be returned to some electronic wastes collection center. The disposal of the product should be conducted as per the local environmental legislation. You may obtain detail information on disposal, reuse and recycling of the product.
 Keep the original packaging of
the product.
 Carry the product in its original packaging, and abide the markings thereon.
 If the original packaging is not available;
 Take care for the impacts which may be applied on the outer surfaces of the product.
 Place/ hold the product in parallel to the ground during carrying (as the upper side will be up).
 Carry the pan holders not touching each other.
Packaging
All packaging materials are recyclable. In order to contribute environmental protection place the packaging material wastes to the recycling bins.
Disposal of the old equipments
The equipments being old and useless should not be thrown to a waste container directly. There may be some parts allowing re-use. Also there may be some environmentally dangerous materials requiring to be given to a collection center. Therefore you should take your unit to a collection center that you may learn from the manufacturer/ dealer in your city and insure that the electronic parts will be recycled.
It is important to keep the user’s manual for it will be important in the event of change of the user of the device.
Before disposal or scraping of the device it is required to prevent harmful and negative effects on human and environment. Otherwise it would be incompliant waste.
5. BEFORE USING YOUR APPLIANCE FOR THE FIRST TIME
 Make sure that you remove all packaging materials before using the unit.
 When you remove the hob from the package make sure that hob and / or the cable is full and undamaged, and no impact was put at the bottom of the device, otherwise consult your seller.
 Any and all works on the gas equipments and systems should be conducted by the competent and authorized persons.
6
ENGLISH TECHNICAL PASSPORT
Gas hob
 Gas hobs cause heat and steam formation at the environments in which they are used.
 Make sure that your kitchen ventilated well. Keep the natural ventilation channels open or use ventilation product (hood).
 Have the required maintenance of the gas products by the competent and authorized persons.
 Clean the gas burners regularly.
 Request the telephone numbers from the local gas suppliers for emergency cases.
Things to be done when gas smells
 Do not use  ame. Do not smoke Do not operate the switch of any
electrical device. Do not use  xed or
mobile phone.
 Close all valves on the gas products and gas counters.
 Open the doors and windows.
 Go out of the house if you smell gas still.
 Warn the neighbors.
 Cal the  re service. Use a phone outside the home.
 Do not enter the house until you
will be noti ed that it is safe.
6. MAINTENANCE AND INSTALLATION MANUAL
6.1. SAFETY INSTALLATION
The installation should be
conducted by an authorized
service
dealer as per the installation
instructions. Our  rm may not be held
liable for any losses and damages to
human, animals or objects due to any inappropriate use of the unit.
PRE-INSTALLATION WARNINGS
ATTENTION: Before the installation
check that the gas type and gas pressure
stated under the product  t those of
your home. Call the authorized service dealer for possible gas type changes in future.
 When the unit was taken off its packaging make sure that it is strong, not bent and has no fault at all. In the event of any doubt consult the dealer.
 Cut off the electric connection of the unit from the main switch during installation.
 In order that built in cook- tops will operate smoothly the measurements of the counter on which it will be mounted and the materials used for installation should be proper, and the counter should be resistant against heat.
Read the following instructions
to fi x the hob on the counter:
In order to prevent insertion of the foreign materials and liquids between the hob and the counter attache the adhesive band on the counter hole without allowing any overlapping before the installation.
Place the hob on the counter hole to center the installation hole.
Secure the unit on the counter by using the installation sheet and screws.
Please review the following  gures
carefully so that the hob will be installed properly.
7
Gas hob
6.2. INSTALLING THE APPLIANCE
This equipment should be mounted at the well ventilated places and as per the regulations in force. The installation personnel should consider the laws and norms applicable to the release of burning gases and ventilation.
 Your hob is designed to be installed on the standard counters which you may nd in
the market.
 The materials used on the surface and the link partitions under the counter should be
resistant against minimum 100°C.
 A safe distance should be left between the hob and the counter walls (Fig. 4).  The hole to be provided for the hob on the counter should be as per the gure. (Fig. 4)  The distance between the hob sole and the partition should be at least 25 mm. (Fig. 5)
TG 39 W
TG 99 W.
TG 79 B
TG 699 B
TS 69 B
FQ7TG L
TS 63 B
TS 63
TS 39 X
FQ4TG S
FV3TG X
TG 69 B
Figure 1.
 The distance between the cook top ad another device (e.g. kitchen hood)
shall not be less than 700 mm (Figure 5).
 If 60 cm Hobs will be place on a built in oven without any cooling system, it is recommended to leave 300 cm2 of ventilation hole in order to insure air circulation. If 75 or 90 cm cook-top will be placed the oven has to have cooling fan.
 There must be 200 cm. space at the side wall off the cabinet of the hob.
8
ENGLISH TECHNICAL PASSPORT
Gas hob
MIN. 700 mm
25 mm
1. Cooktop
2. Aspirator
3. Electrical ventilator
4. Ventilation Opening
Figure 3.
Figure 2.
Release of Burnt Gases
 The air required for burning is taken to the environment of the hob and the burnt gas are released to the environment. Proper ventilation should be maintained for safe operation of the
unit. The ventilation openings dened
as per the volume of the environment are provided at the bale (Table 1).
 Burnt gases should be discharged
outside by the hood with ume.
 If no kitchen hood is used, an electrical ventilator should be used having guaranteed capacity to discharge 3-5 times of the kitchen air to be installed at the wall or window of the building (Figure 6)
VOLUME OF THE
ROOM (m.)
Less than 5 m
Between 5m
and 10 m
Larger than 10 m
Basement or Cellar Minimum 65 cm
3
3
3
VENTILATION
OPENING (cm.)
Minimum 100 cm
Minimum 50 cm
3
Not required
2
2
2
Table 1
Installation of the Hob on the Counter
 In order to prevent insertion of the foreign materials and liquids between the hob and the counter attache the gasket on the counter hole without allowing any overlapping before the installation. (Figure 7)
 Place the hob on the counter hole to center the installation hole.
 Secure the unit on the counter by using the installation sheet and screws. (Figure 7 and 8)
9
Gas hob
Counter
Installation Clamp
Gasket
Figure 4.
Installation Clamp
Figure 5.
6.3. ELECTRIC CONNECTION
 Electric connection should be conducted by a competent and authorized person.
 The electric cable of your hob should not be laid at hot regions.
 When the power cable is damaged this cable should be changed with a special cable to be supplied by a special cable agency or the authorized service dealer.
 No reducer, adapter, and switch should be used for electrical connection since it will cause excessive heat and
re.
 Plug the electric cable to a grounded wall socket. The manufacturer hereby declares that it will be released all liability in the event of any failure in this issue.
 The supply data of the electric network should be suitable with the data on the type label of the unit.
6.4. GAS CONNECTION
These instructions are prepared for
specialist personnel having required
competence, the installation of the equipment should be suitable as per
the applicable standards.
All gas related works should be conducted when the electric connection was cut.
The value plate on the hob indicates the gas type intended to be used for use with the hob. Connection to the main gas course or gas type shall be realized after controlling the adjustment as per the gas type. Connection to the main gas source or gas cylinder shall be conducted after checking the adjustment according to the proper gas type. If it is set properly look at the following paragraphs:
Note that the LPG hoods should have standarts stamp and 300 mmSS (30mbar) of outlet pressure.
Natural gas pressure is 200 mmSS (20mbar). Please consult the authorized service for conversion to natural gas or LPG.
Use only piping, gaskets or stamp as per the applicable national standards.
In some countries where conic connections are obligatory, conic connection is provided. In such a case the conic connection part should be connected to the unit.
If the unit will be connected to a
exible hose, the length of the hose
shall not exceed 120 cm.
Before starting works related to gas installation, please cut the gas supply.
10
ENGLISH TECHNICAL PASSPORT
Gas hob
Make the connection so that no pressure will be applied on the connection records and piping. Make sure that the pipe will not cause any clogging or contact with the sharp corners.
Note that the gas hose will not be laid through hot areas.
NOTE: Replace the gas hose of your hob at 4 to 5 years even if it will be undamaged.
NOTE: Check whether any gas leakage after the connection with soap
and water. Do not ever use ame.
Make sure that no additional weight to be applied on the gas hose.
And apply the following order for installation:
1. In the order; male adaptor cylindrical, gasket, female gas adaptor, conical-cylindrical or cylindrical cylindrical components,
2. Tighten connection place with the keys so that the pipes will be in proper position,
3. Attach C coupling to the main gas source by using hard copper pipe or
exible steel pipe.
WARNING; Final Check whether
any leakage exists at the pipes with a
solution with a soap, and do not ever
use ame.
6.5. ADJUSTMENT OF HOB
PER GAS TYPES
These instructions are prepared for specialist personnel having required competence, the installation of the
equipment should be suitable as per the applicable standards.
 All gas related works should be conducted when the electric connection was cut.
In order to convert the hob, remove
the burner plates and ame circles
thereon. Replace the injectors as per the followings, and change them with the injectors with suitable diameters
dened in the user’s manual. Conduct
the works with a plain tip screwdriver at a position to see valve setting screw by removing the switches of the hob and rubber seals. In order to set the
low ame level, turn the gas setting
screw on the valve to have minimum
gas setting ow. Do this setting after
installing the burner component of the burner, burning the burner and bringing the switch setting to minimum.
Flow setting screw should be tightened in LPG conversions as it should be released for conversion from LPG to natural gas.
11
Gas hob
After realization of the hob, complete the conversion transaction by connecting the rubber seals and switched in the same order.
These instructions should be used by an authorized service. The products should be installed as per the regulations in force and in proper manner. Before conducting any transaction the electrical connections of the hob should be cut by no means.
The type label on the hob indicates the gas type planned to be used with the unit.
6.6. STARTING THE APPLIANCE
FIRING OF BURNER
If your hob does not have built in lighter or during black out place the
naked ame over the burner and push
the switch to bring it to the desired position with counter-clockwise movement. Gas adjustment should
be between maximum and minimum
levels, it should not be realized between
maximum and off positions. To close the burner turn the switch clockwise till to reach “off” position.
MODELS EQUIPPED WITH
LIGHTER SWITCH (Automatic
ignition)
In order to burn one of the burners, press the switch down and bring the switch to maximum position. When it
burns, ame is adjusted to the desired
intensity with the switch.
RIGHT WRONG
Figure 6.
 In order that the hob will
operate properly the grills and burner
components should be properly
positioned.(Figure 1)
 Make sure that the ame of your
burner is in blue color and work quietly.
If the burner will burn in yellow color
or work with voice make sure that all
burners t properly. If the ame color
does not change to blue color then
apply the authorized service.
12
ENGLISH TECHNICAL PASSPORT
Gas hob
6.7. TECHNICAL CHARACTERISTIC AND DRAWINGS
TS 63 TS 69
TG 99 TS 99
TG 799 TS 799
TG 69 TS 39 TG 39
FQ4TG FV3TG FQ3TG
FQ7TG TS 63E TG 49
1. Mini wok burner control knob
2. Semi rapid burner control knob
(1,75 kW)
3. Auxilary burner control knob
4. Right cast iron grid
5. Auxilary burner
6. Semi rapid burner (1,75 kW)
7. Electric connection cable
8. Left cast iron grid
9. Mini wok burner
10. Wok burner control knob
11. Wok burner
12. Rapid burner
13. Rapid burner control knob
14. Semi rapid burner (1,4 kW)
15. Semi rapid burner control knob
(1,4 kW)
16. Middle cast iron grid
17. Electric Burner
18. Electric knob control knob
13
Gas hob
TG 799 TS 799
TS 99 TG 99
FQ7TG
Number of Burner
Auxilary Burner (1 kW) 1 Unit(s) 1 Unit(s) 1 Unit(s) 1 Unit(s) 1 Unit(s) 1 Unit(s) 1 Unit(s)
Semi-rapid Burner (1,4 kW)
Semi-rapid Burner (1,75 kW)
Rapid Burner (3 kW) 1 Unit(s) - - 1 Unit(s) 1 Unit(s) 1 Unit(s) 1 Unit(s) Wok Burner (3,8 kW) 1 Unit(s) - 1 Unit(s) - - - ­Wok Burner (2,5 kW) - 1 Unit(s) - - - ­(1,5 kW) - - - - - - 1 Unit(s) Total Power 11,3 kW 7 k W 8,3 kW 7,15 kW 4 kW 5,75 kW 6,9 kW Gas Consumption G20-
20mbar Gas Consumption G30-
30mbar Gas Category II2H3+ II2H3+ II2H3+ II2H3+ II2H3+ II2H3+ II2H3+ Installation Class 3 3 3 3 3 3 3
Electric Supply
Flame Failure Safety Device
Supply Cable YES YES YES YES YES YES YES Automatic Ignition YES YES YES YES YES YES YES
Product Measurement
5 Gas Burners
- - - 1 Unit(s) - - 1 Unit(s)
2 Unit(s) 2 Unit(s) 2 Unit(s) 1 Unit(s) - 1 Unit(s) -
1077 l/h 667 l/h 791 l/h 682 l/h 381 l/h 548 l/h 515 l/h
822 g/h 509 g/h 604 g/h 519 g/h 291 g/h 418 g/h 392 g/h
220-240 V 50-60 Hz
Optional Optional Optional Optional Optional Optional Optional
TG 799 FQ7TG 750x520 mm TS 799 750x510 mm TG 99 860x520 mm TS 99 860x510 mm
TG 699 TS 69 TS 63
4 Gas Burners
220-240 V 50-60 Hz
TG 69 590x520 mm
4 Gas Burners
220-240 V 50-60 Hz
TS 69 580x510 mm
MODELS
4 Gas Burners
220-240 V 50-60 Hz
TS 63 580x510 mm
TS 39
TG 39 FV3TG FQ3TG
2 Gas Burners
220-240 V 50-60 Hz
TS 39 FV3TG 305x510 mm TG 39 FQ3TG 320x520 mm
FQ4TG TG 49
3 Gas Burners
220-240 V 50-60 Hz
FQ4TG TG 49 450x520 mm
TS 63E
3 Gas Burners
220-240 V 50-60 Hz
TS E63 580x510 mm
6.8. TECHNICAL INFORMATION ON GAS BURNERS
A Burner SR Burner (1,4
G 30-30 mbar LPG (0,50 mm)
G20–20 mbar NG (0,72 mm)
kW) G 30-30 mbar
LPG (0,57 mm)
G20–20 mbar NG (0,85 mm)
Note: The burner positions on the burner table are indicated on the burner plate.
SR Burner (1,75 kW)
G 30-30 mbar LPG (0,65 mm)
G20–20 mbar NG (0,97 mm)
R Burner Wok Burner (2,5
G 30-30 mbar LPG (0,85 mm)
G20–20 mbar NG (1,15 mm)
kW) G 30-30 mbar
LPG (0,82 mm)
G20 –20 mbar NG (1,15 mm)
14
Wok Burner (3,8 kW)
G 30-30 mbar LPG (0,98 mm)
G20 – 20 mbar NG (1,35 mm)
ENGLISH TECHNICAL PASSPORT
Gas hob
1. Right rear hot-plate control switch
2. Left front burner control switch
3. Left rear burner control switch
4. Right front burner control switch
1. Nitril/Clingiric Gasket
2. Elbow
3. LPG Hose Entrance
Complete the installation by using
gasket in the middle for the LPG hose
entrance indicated on the above fi gure
during the natural gas LPG conversion.
7. CONTROLLER TYPES AND USE
7.1. CONTROL PANEL
1. Rear burner control switch
2. Front burner control switch
1. Left front burner control switch
2. Left rear burner control switch
3. Middle burner control switch
4. Right rear burner control switch
5. Right front burner control switch
1. Left burner control switch
2. Middle front burner control switch
3. Middle rear burner control switch
4. Right rear burner control switch
5. Right front burner control switch
7.2. BASIC SETTINGS
7.2.1. FOR GAS BURNERS
Operation of the burners and power levels
Turn the control switch left-wise until reaching to maximum level. When you press the control switch all burning
igniters will have  ame to burn. Release
the switch in few seconds after burning of the burner, and bring the control switch
to the desired  ame position between the
maximum and minimum levels. (Figure 2)
1. Left front burner control switch
2. Left rear burner control switch
3. Right burner control switch
15
Loading...
+ 33 hidden pages