KUNTENG KT-LCD3 Product User Manual

Page 1
用户手册
User Manual
KT-LCD3 eBike Special Meter
WWW.SZKTDZ.COM
Page 2
ELECTRIC BICYCLE METER KTLCD3 Product User Manual
- 1 -
Contents
Preface……………………………………………………………………………..………. 4 Outlook and Size…………………………………………………………………………... 4
MeterDimension……………………………………………………………………… 4 Button Box Dimension……………………………………………………………….. 4
Main Material and Color………………………………………………….………...... 5
Wiring Schematic……………………………………………………………….……. 5
Installation Instruction……………………………………………………………….…….. 5
Φ 31.8 handlebar diameters install icon………………………………………..….… 5 Φ 22.2 handlebar diameters install icon……………………………………….….…. 5
Physical installation icon............................................................................................. 6
Function Overview…………………………………………………………………….... 6 Display Content……………………………………………………………………..... 7 Button Definition……………………………………………………………………... 7
Normal Operation………………………………………………………………………...... 7
On/Off…………………………………………………………………………........... 7
Display Interface…………………………………………………………..……..... 8
Display 1………………………………………………………………..……...... 8
Display 2……………………………………………………………………...... 9
Display 3……………………………………………………………..……….... 10
Display of Turned on Handlebar……………………………………………………. 11 Display of Power-assist Startup…………………………………………………….. 11 PAS Ratio (or Handlebar) Gear Switch……………………………….……………. 12 Push Function…………………………………………………………..…………… 12 Cruise Function…………………………………………………………………... 13 Turn On/Off Backlight…………………………………………………….………... 13
Battery Capacity Indicator…………………………………………..……………. 13
Motor Power and Temperature ................................................................................... 14
Page 3
ELECTRIC BICYCLE METER KTLCD3 Product User Manual
- 2 -
Environment Temperature…………………………………………………………... 15
Single Data Clearing……………………………………………………………….... 15
Automatic Prompt Interface…………………………………………………….... 16
Error Code Display…………………………………………………….…........ 16
Motor Operating Temperature Alarm……………………………………......... 16
User Project Setting……………………………………………………………………..... 16
General Project Setting…………………………………………………………………… 17
Maximum Trip Speed………………………………………………………….......... 17
Wheel Diameter…………………………………………………………………... 17 Metric and Imperial Units…………………………………………………………... 18
Exit General Project Setting……………………………………………………….... 19
P Parameter Setting……………………………………………………………….…….... 19
P1 Motor Characteristic Parameter Setting ............................................................... 19
P2 Wheel Speed Pulse Signal Setting ....................................................................... 20
P3 Power Assist Control Mode Setting ...................................................................... 21
P4 Handlebar Startup Setting ..................................................................................... 21
P5 Power Monitoring Setting ..................................................................................... 22
Exit P Parameter Setting ............................................................................................. 23
C Parameter Setting ............................................................................................................ 23
C1 Power Assist Sensor and Parameter Selection Setting ......................................... 23
C2 Motor Phase Classification Coding Setting .......................................................... 24
C3 Power Assist Ratio Gear Initialization Setting ..................................................... 25
C4 Handlebar Function Setting .................................................................................. 25
C5 Controller Maximum Current Adjustment Setting ............................................... 27
C6 Backlight Brightness Adjustment Setting ............................................................. 28
C7 Cruise Function Setting ........................................................................................ 28
C8 Motor Operating Temperature Display Setting .................................................... 29
C9 Power-on Password Setting .................................................................................. 30
C10 Automatic Restore Factory Setting ..................................................................... 31
C11 Meter Attribute Selection Setting ....................................................................... 32
Page 4
ELECTRIC BICYCLE METER KTLCD3 Product User Manual
- 3 -
C12 Controller Minimum Voltage Adjustment Setting ............................................. 33
C13 ABS brakes of the controller and parameters of anti-charge control Setting ......34
C14 Power-assist tuning parameters Setting ...............................................................35
Exit C Parameter Setting............................................................................................. 36
Parameter Copy .................................................................................................................. 36
User Setting Note ............................................................................................................... 37
Version Information……………………………………………………………………… 38
Page 5
ELECTRIC BICYCLE METER KTLCD3 Product User Manual
- 4 -
Preface
The illustrated manual will help you understand and be familiar with the meter function, guiding you on how to operate the meter, how to set the project parameters, how to achieve the best match of the three as motor, controller and meter to improve electronic control performance of the electric motor. This manual covers installation, operation, parameter setting of the meter and how to use it properly, which help you resolve the problems appeared in practical use.
Outlook and Size
Meter Dimension
Meter Dimension
Dual Bracket Mounting Dimension
Button Box Dimension
Page 6
ELECTRIC BICYCLE METER KTLCD3 Product User Manual
- 5 -
Main Material and Color
PC material is mainly used for KT-LCD3 meter and button box housing, and the housing color is dark gray or white.
Wiring Schematic
Installation Instruction
The meter body and button box are mounted on the handlebars of the electric vehicle, adjusting perspective. In the case that the vehicle is power off, the meter connectors are in plug connection to corresponding controller connectors. Turn on the power, electric vehicle and meter will be under normal operation, the meter installation is finished. The protection film on meter display panel should be torn.
Φ 31.8 handlebar diameters install icon
Φ 22.2 handlebar diameters install icon
Page 7
ELECTRIC BICYCLE METER KTLCD3 Product User Manual
- 6 -
Physical installation icon
Function Overview
KT-LCD3 meter provide you with a variety of functions such as vehicle controls and vehicle status digitized displays to meet the trip demands.
Trip time display (with displays of a single trip time (TM) and total trip time (TTM)); Trip speed display (with displays of real-time speed (Km/H or MPH) and a single
maximum speed (MXS) and a single average speed (AVS));
Trip distance display (with displays of a single trip distance (DST) and total trip
distance (ODO));
Display of turned on handlebar;Display of power-assist startup; ◇ Power assistant ratio (or handlebar) gear (ASSIST) switch;
6Km/H power assistant push ( ) function; Cruise function (CRUISE); Battery capacity indicator ( );
Real-time battery voltage (VOL) display; Motor power and temperature (MOTOR) display;
Brake display ( );
Turn on backlighting and lights ( ); Environment temperature (℃ or ℉) display;
Data clearing; Fault code display; User parameter setting
Page 8
ELECTRIC BICYCLE METER KTLCD3 Product User Manual
- 7 -
24V, 36V, 48V supply voltage can automatic identification and be compatible
Display Content
The display content is shown as follow.
Button Definition
KT-LCD3 meter adopts the structural form with part design between the main part and operating buttons.
There are three keys on the operating panel of button box, which are icons of
button (alt text UP), button (alt text SW) and (alt text DOWN).
Button Box and Operating Panel
Normal Operation
On/Off
Hold button (SW) long, the meter is powered on and into normal operation, and
it provides the controller with power supply. Under normal operating status, hold button (SW) long, the meter is powered off, meanwhile to shutdown the power supply of
controllers. When the vehicle is stopped and without any button operation on the
Page 9
ELECTRIC BICYCLE METER KTLCD3 Product User Manual
- 8 -
meter for five minutes, the meter will automatically shut down, and the power supply of the electric vehicle will be powered off. In power off mode, the power consumption of
the meter and controller is zero.
Display Interface
Display 1
The meter is startup to enter display 1.
Display 1
The followings are shown on display 1.
Battery Capacity Indicator Single Trip Time (TM) Display
Power Assist Ratio Gear (ASSIST) Real-time Trip Speed (Km/H)
Single Trip Distance 6Km/H Power Assist Function
Page 10
ELECTRIC BICYCLE METER KTLCD3 Product User Manual
- 9 -
Motor Operation Power Environment Temperature
Backlights and Headlights Status Brake Status
Cruise Function (CRUISE) Motor Running Temperature
Display 2
In display 1, hold button (SW) shortly to enter display 2.
Display 2
The followings are shown on display 2:
Total Trip Time (TTM) Total Trip Distance (ODO)
Page 11
ELECTRIC BICYCLE METER KTLCD3 Product User Manual
- 10 -
Single Average Speed (AVS) Motor Operating Temperature
In the riding mode after 5 seconds, display 2 automatically returns to display 1. In display 1, the original motor power is replaced by motor running temperature as is shown in Figure.
Display 3
In display 2, hold button (SW) shortly to enter display 3.
Display 3
The followings are shown on display 3.
Single Maximum Speed (MXS) Real-time Voltage (VOL)
In the riding mode after 5 seconds, single maximum speed will automatically return to real-time trip speed (Km/H) as shown in the icon.
Page 12
ELECTRIC BICYCLE METER KTLCD3 Product User Manual
- 11 -
In display 3, hold button (SW) shortly again to enter display 1.
In each display interface, if you hold button (SW) long, the meter will be
powered-off together with that of the controller.
Display of turned on handlebar
Rotate the handlebar under normal operating of the meter, the display interface shows the sign of turned-on handlebar, see the Figure below. The sign will be off automatically after about five seconds.
Display of power-assist startup
The meter is driving with power-assist under normal operating conditions, the display interface flashes the power-assist startup sign (ASSIST) as shown in the figure. The sign will be off automatically after about five seconds.
Page 13
ELECTRIC BICYCLE METER KTLCD3 Product User Manual
- 12 -
PAS Ratio (or Handlebar) Gear Switch
Under normal operation, hold button (UP) or button (DOWN) to switch the power assist ratio (or handlebar) gear (ASSIST), changing motor output power. Switching range is 1-5 gear (this can also be configured according to the customer requirements), gear 1 is for the lowest power, and gear 5 is for the highest power.
At every startup, the meter will automatically restore gear (this can also be configured as required by users) when it was at last shut down. When the power assist ratio is gear 0 zero, there’s no power assist function.
Power Assistant Push Function
Users can use 6Km/H power assist function when pushing vehicles. Hold
button (DOWN), the meter assist function logo ( ) flashes, the vehicle drives at the speed
of no more than 6Km/h. Release button (DOWN), the assist function will be revoked.
Page 14
ELECTRIC BICYCLE METER KTLCD3 Product User Manual
- 13 -
Cruise Function
When C7 parameter setting is 1 (see C parameter setting), the meter turns on cruise
function, hold button (DOWN) long to enter the cruise status when the vehicle speed is more than 7 km/h, and the cruise function logo (CRUISE) lights. Brake or hold any button to revoke cruise function.
Startup Backlights and Headlights
Hold button (UP) long, the meter turns on the backlights as well as the vehicle
headlights (the Controller should have headlights driving and output functions), meter
backlighting and vehicle lights power logo ( ) light, hold button (UP) long again to turn off backlights and vehicle headlights.
Battery Capacity Indicator
The meter can automatically identify 24V, 36V, 48V battery capacities when it is supporting use with the specified controller. When the battery capacity is over 70%, the four power displays of the meter are lit, when the battery capacities drop, the four power displays are off in order, when the power capacity is less than 15%, the four power displays are totally turned off.
Page 15
ELECTRIC BICYCLE METER KTLCD3 Product User Manual
- 14 -
When the controller is power off due to voltage shortage, the power display frame flashes, indicating the vehicle has been in voltage shortage and waiting for shutdown currently.
Voltage shortage flashes
Battery capacity indicator
Motor Operating Power and Temperature
Under the riding status of vehicle, the real time running and output power can be known via the meter displays.
Motor operating power
The operating temperature of the motor shows there should be a temperature sensor installed in the Inner motor to output the temperature for signal detection simultaneously.
Page 16
ELECTRIC BICYCLE METER KTLCD3 Product User Manual
- 15 -
Motor operating temperature
When the motor operating temperature exceeds the warning value, temperature display flashes to alarm, meanwhile the motor controller will offer the appropriate protection to motor.
Environment Temperature
After startup, the environment temperature for using meter will be displayed in environment temperature display column.
Environment temperature display
The temperature display value may be in deviation shortly after boot-up, and the display value will be gradually approaching the environment temperature within 10 minutes after boot-up.
Single Data Clearing
5 seconds after the meter is powered on, at display 1, hold both the button (UP)
and the button (DOWN) simultaneously for about 2 seconds, the single trip time
(TM) and single trip distance (DST) flicker, then hold button shortly (SW), the record contents of both will be cleared.
Single data clearing display
Under the status of data flashing, if there were no operations on the data within 5
Page 17
ELECTRIC BICYCLE METER KTLCD3 Product User Manual
- 16 -
seconds, the meter will automatically return to display1 after 5 seconds, and the original record content will be saved.
Automatically Prompt Interface
Error Code Display
When the electronic control system of the electric vehicle fails, and the meter will
automatically display (flicker) fault code. You can’t exit the fault code display only the fault is removed.
Error Code Display
Error Code & Definition Table
Error Code
Definition
01_info
Throttle Abnormality
03_info
Motor Hall Signal Abnormality
04_info
Torque sensor Signal Abnormality
05_info
Axis speed sensor Abnormality(only applied to torque sensor )
06_info
Motor or controller has short circuit Abnormality
Motor operating temperature alarm
Under any interface, when the motor operating temperature exceeds the warning value,
the motor operating temperature display flashes to alarm, meanwhile, the controller will offer the appropriate protection to motor.
User Setting Project
KT-LCD3 meter user setting project
General project setting P parameter setting C parameter setting
Page 18
ELECTRIC BICYCLE METER KTLCD3 Product User Manual
- 17 -
General Project Setting
Maximum Trip Speed
Under power off status, hold button long (SW), the meter is turned on. Within
5 seconds after boot-up, hold button (UP) and button (DOWN) simultaneously for about 2 seconds, the first is to enter the maximum riding speed setting
interface, then the speed display column flashes. Hold button shortly (UP) or button (DOWN) in order to set the maximum riding speed value. The default maximum riding speed value was 25Km/h. When the speed of the electric vehicle exceeds the set value, the motor will be stopped driving.
Setting interface of maximum trip speed
Under the setting maximum riding speed interface, if there’s no button operation on the meter for more than 1 minute, and then the meter will automatically return to display 1, and the original set values will be saved.
After finishing the maximum riding speed setting, hold button shortly (SW) to
save the current set values and enter into the next setting.
Wheel Diameter
After finishing the maximum riding speed setting, enter the wheel diameter setting
interface, and then the wheel diameter display column flashes. Hold button (UP) or
button (DOWN) to choose the corresponding wheel diameter specification to a
selected vehicle. The selection range of wheel diameter specifications are 13 species such as 6,8,10,12,14,16,18,20,22,24,26,700 c and 28 inches.
Page 19
ELECTRIC BICYCLE METER KTLCD3 Product User Manual
- 18 -
Setting Interface of Wheel Diameter
Under the wheel diameter setting interface, if there’s no button operation on the meter for more than 1 minute, and then the meter will automatically return to display 1, and the original set values will be saved.
After finishing the wheel diameter setting, hold button (SW) shortly to save the
current set specification and enter into the next setting.
Metric and Imperial Units
After finishing the wheel diameter setting, enter into the metric/imperial units setting
interface, and then the speed and mileage unit flash. Hold button (UP) or button (DOWN) shortly to make sync selection of three metric/imperial units as speed, mileage, and the environment temperature.
Setting Interface of Metric/Imperial Units
Definition Table of Metric/Imperial Units
Display
Metric
Imperial
Riding speed
Km/H
MPH
Total distance
Km
Mil
Environment
temperature
Temperature
Fahrenheit
Under the metric/imperial units setting interface, if there’s no button operation
Page 20
ELECTRIC BICYCLE METER KTLCD3 Product User Manual
- 19 -
on the meter for more than 1 minute, and then the meter will automatically return to display 1, and the original set units will be saved.
After finishing the metric/imperial units setting, hold button shortly (SW) to
save the current set values, and then speed and mileage units stop flashing. Hold button (SW) shortly again, and the meter will enter into the maximum riding speed
interface again, or hold button (SW) long for about 2 seconds to exit the general project setting environment and return to display 1.
Exit General Project Setting
Among the three general project settings, after each setting is completed, if hold
button (SW) long for about 2 seconds, all can exit the setting environment and return to display 1, meanwhile, the current set parameters are saved.
Under each setting interface, if there’s no button operation on the meter for more than 1 minute, and then the meter will automatically return to display 1, and the original set parameters will be saved.
P Parameter Setting
After finishing metric/imperial unit settings, the speed and mileage units stop flashing.
Within one minute after stopping flashing, hold button (UP) and button (DOWN) simultaneously for about 2 seconds to enter P parameter setting environment.
P1 Motor Characteristic Parameter Setting
P1 is motor characteristic parameter setting, P1 = motor gear reduction ratio× number of rotor magnet pieces, just rounding if there’s any decimal.
After entering P parameter setting environment, the first is to set P1parameter, P1
parameter column flashes. P1 setting ranges between1-255, hold button (UP) or
button (DOWN) shortly for selection.
Page 21
ELECTRIC BICYCLE METER KTLCD3 Product User Manual
- 20 -
P1 parameter setting interface
Under P1 parameter setting interface, if there’s no button operation on the meter for more than 1 minute, and then the meter will automatically return to display 1, and the original set parameter will be saved.
After finishing P1 parameter setting, hold button shortly to save the current set values and enter P2 parameter setting interface.
P2 Wheel Speed Pulse Signal Setting
Enter P2 parameter setting interface after P1 parameter setting is finished, and P2 parameter column flashes.
P2 parameter setting interface
P2 is wheel speed pulse signal setting, if wheel generated 1 pulse signal by a revolution, P2 should be set as1. If wheel generated 6 pulse signals by a revolution, P2 should be set as 6. If users didn’t configure the pulse signal system, and then P2 parameter
setting can be 0. The setting range of P2 should be between 0-6, hold button (UP)
shortly or button (DOWN) for selection.
Under P2 parameter setting interface, if there’s no button operation on the meter for more than 1 minute, and then the meter will automatically return to display 1, and the original set parameter will be saved.
Page 22
ELECTRIC BICYCLE METER KTLCD3 Product User Manual
- 21 -
After finishing P2 parameter setting, hold button (SW) shortly to save the
current set values and enter P3 parameter setting interface.
Please Note:when P2 parameter is set to be 0, for the built-in clutch motor, there will be the following defects, when the internal motor rotors stop or the internal rotor speed is lower than the outer rotor speed, then the speed displayed on the meter is inaccurate!
P3 Power Assist Control Mode Setting
Enter P3 parameter setting interface after P2 parameter setting is finished, and P3 parameter column flashes.
P3 parameter setting interface
P3 is power assist control mode setting, when P3 parameter setting is1, power assist control mode is gear 5 of "imitation torque control" mode, when P3 parameter setting is 0, power assist control mode is gear 5 of "speed control" mode. P3 parameter needs to be determined according to the distributed function of the controller, its setting range is 0 or 1,
hold button (UP) shortly or button (DOWN) for selection. P3 parameter setting method is the same to that of P2.
P4 Handlebar Startup Setting
Enter P4 parameter setting interface after P3 parameter setting is finished, P4 parameter column flashes.
Page 23
ELECTRIC BICYCLE METER KTLCD3 Product User Manual
- 22 -
P4 parameter setting interface
P4 is handlebar startup setting, when P4 setting is 1, indicating the handlebar is under "non-zero startup" mode, namely, the handlebar can be effective only after startup the foot power assist. When P4 setting is 0, indicating the handlebar is under "zero startup" mode, the motor can be startup by the handlebar directly. P4 setting range is 0 or 1, hold
button (UP) or button (DOWN) shortly for selection. P4 parameter setting method is the same to that of P2.
P5 Power Monitoring Setting
Enter P5 parameter setting interface after P4 parameter setting is finished, P5 parameter column flashes.
P5 parameter setting interface
P5 is power monitoring setting, when P5 setting is 0, the power monitoring is the "real-time voltage" mode. Namely, it is the method to determine the battery capacity based on real-time battery voltage. When P5 equals to a specified parameter, the power monitoring is the "smart power" mode (this parameter is determined by the battery characteristics, ordinary 24V lithium is generally is 4-11, 36V lithium is between 5_15). P5
setting ranges from 0-40, hold button (UP) or button (DOWN) shortly for selection. P 5 parameter setting method is the same to that of P2.
After finishing P5 parameter setting, hold button (SW) shortly to save current
set the values, and then P5 parameter column stops flashing. Hold button (SW)
shortly again, the meter re-enter P1 parameter setting interface. Or hold button (SW) long for about 2 seconds to exit P parameter setting environment and return to the display
Page 24
ELECTRIC BICYCLE METER KTLCD3 Product User Manual
- 23 -
1.
Exit P Parameter Setting
Among the five P parameter settings, when each parameter setting is completed, if
held button (SW) long for about 2 seconds, all can exit the setting environment and return to display 1, meanwhile, the current set parameters would be saved.
Under each parameter setting interface, if there’s no button operation on the meter for more than 1 minute, and then the meter will automatically return to display 1, and the original set parameters will be saved.
C Parameter Setting
After finishing P5 parameter setting, P5 parameter column stops flashing. Within 1
minute after stopping flashing, hold button (UP) and button (DOWN) for about 2 seconds to enter C parameter setting environment.
C1 Power-Assist Sensor and Parameter Select Setting
Set C1 parameter first after entering C parameter setting environment, C1 parameter column flashes.
C1 parameter setting interface
C1 is power-assist sensor and parameter select setting, its definition is shown in
following table. C1 setting ranges between 0-7, hold button (UP) or button (DOWN) for selection. C1 parameter definition table
KUNTENG power assist
sensors
C1
value
Start
Sensitivity
KUNTENG V12
power assist sensors
C1
value
Start
Sensitivity
Forward 5 Signal
00
Standard
Reverse 6 Signal
05
Standard
01
Lower
06
Lower
Page 25
ELECTRIC BICYCLE METER KTLCD3 Product User Manual
- 24 -
02
Lowest
07
Lowest
Forward 8 Signal
00
Higher
Reverse 10 Signal
05
Higher
01
Standard
06
Standard
02
Lower
07
Lower
Forward 10 Signal
00
Highest
Reverse 12 Signal
05
Highest
01
Higher
06
Higher
02
Standard
07
Standard
After finishing C1 parameter setting, hold button (SW) shortly to save the current set values and enter C2 parameter setting interface.
C2 Motor Phase Classification Coding Setting
Enter C2 parameter setting interface after C1 parameter setting is finished, C2 parameter column flashes.
C2 parameter setting interface
C2 is motor phase classification coding setting, it is served as identification parameter of different phases of the motor when using sine wave drive and the default value is 0. When C2 setting is 0, indicating that the used Quantum motor phase is an ordinary one. When the setting is a certain value, indicating a particular motor phase is used. C2 setting
range is 0-7, hold button (UP) or button (DOWN) for selection.
After finishing C2 parameter setting, hold button (SW) shortly to save the current set values and enter C3 parameter setting interface.
Page 26
ELECTRIC BICYCLE METER KTLCD3 Product User Manual
- 25 -
C3 Power Assist Ratio Gear Initialization Setting
Enter C3 parameter setting interface after C2 parameter setting is finished, C3 parameter column flashes.
C3 parameter setting interface
Hold button (UP) or button (DOWN) for selection C3 parameter values. The factory default is 8. C3 parameter values
C3
Parameter value meaning
0
The meter is powered on and the power assist ratio is at gear 0.
1
The meter is powered on and the power assist ratio is at gear 1.
2
The meter is powered on and the power assist ratio is at gear 2.
3
The meter is powered on and the power assist ratio is at gear 3.
4
The meter is powered on and the power assist ratio is at gear 4.
5
The meter is powered on and the power assist ratio is at gear 5.
6&7
Retain
8
Each startup will automatically restore the gear shutdown last time.
After finishing C3 parameter setting, hold button (SW) shortly to save the current set values and enter C4 parameter setting interface.
C4 Handlebar Function Setting
Enter C4 parameter setting interface after C3 parameter setting is finished, C4 parameter column flashes.
Page 27
ELECTRIC BICYCLE METER KTLCD3 Product User Manual
- 26 -
C4 parameter setting interface
C4 is handlebar function setting, the setting range is 0-4, hold button (UP) or
button (DOWN) for selection.
C4 parameter definition table
C4 value
P4=0
P4=1
0
zero startup handlebar
Non-zero startup handlebar
1
Zero startup, handlebar speed limit is 6Km/h
Before power assist, the handlebar speed limit is 6Km/h, after power assist, handlebar is full speed.
2
Zero startup, handlebar speed limit is specified
Non-zero startup, handlebar is specified speed limit.
3
Zero startup, Zero gear effectively
Before power assist, the handlebar speed limit is 6Km/h, after power assist, handlebar is full speed. Stop power assist, return the handlebar speed limit is 6Km/h.
4
Handlebar gears is distinguished according to the display meter.
Non-zero startup handlebar, Handlebar gears is distinguished according to the display meter.
5
Retain
Retain
When C4 = 2 is confirmed, "specified speed limit value of handlebar" flashes, press (UP) button or (DOWN) button for short to make selection, and the
default value is 20.
When C4 = 4 is confirmed, the "percentage value of the first gear speed accounts for its full speed" of the power assist gear flashes, press (UP) button or
(DOWN) button for short to make selection, and the default value is 50%. The
percentage values of other gears divide automatically in equal.
Page 28
ELECTRIC BICYCLE METER KTLCD3 Product User Manual
- 27 -
After finishing C4 parameter setting, hold button (SW) shortly to save the current set values and enter C5 parameter setting interface.
C5 Controller Maximum Current Adjustment Setting
Enter C5 parameter setting interface after C4 parameter setting is finished, C5 parameter column flashes.
C5 parameter setting interface
C5 is controller maximum operating current adjustment setting(tiny-adjustment of
limit current value), the default value is 10, setting range is 0-10, hold button (UP)
or button (DOWN) shortly for selection. C5 parameter definition table
C5 value
Maximum current value(A)
00
Undefined
01
Undefined
02
Undefined
03
Maximum current value÷2.00
04
Maximum current value÷1.50
05
Maximum current value÷1.33
06
Maximum current value÷1.25
07
Maximum current value÷1.20
08
Maximum current value÷1.15
09
Maximum current value÷1.10
10
Maximum current value
When C5 setting is 10, maximum current value is controller maximum operating
Page 29
ELECTRIC BICYCLE METER KTLCD3 Product User Manual
- 28 -
current value (ie, limit current value); when setting is 9, maximum current value divided by
1.10, when setting is 8, maximum current value divided by 1.15 and so on.
After finishing C5 parameter setting, hold button (SW) shortly to save the current set values and enter C6 parameter setting interface.
C6 Backlight Brightness Adjustment Setting
Enter C6 parameter setting interface after C5 parameter setting is finished, C6 parameter column flashes.
C6 parameter setting interface
C6 is the meter backlight brightness adjustment setting, the default value is 3, and
setting range is 1-5, hold button (UP) or button (DOWN) shortly for selection. C6 parameter definition table
C6 value
Backlight brightness
1
Dimmest
2
Darker
3
Standard
4
Brighter
5
Brightest
After finishing C6 parameter setting, hold button (SW) shortly to save the current set values and enter C7 parameter setting interface.
C7 Cruise Function Setting
Enter C7 parameter setting interface after C6 parameter setting is finished, C7
Page 30
ELECTRIC BICYCLE METER KTLCD3 Product User Manual
- 29 -
parameter column flashes.
C7 parameter setting interface
C7 is cruise function setting, the setting range is 0 or 1, hold button (UP) or
button (DOWN) shortly for selection.
C7 parameter definition table
C7 value
Cruise function
0
Off
1
On
After finishing C7 parameter setting, hold button (SW) shortly to save the current set values and enter C8 parameter setting interface.
C8 Motor Operating Temperature Display Setting
Enter C8 parameter setting interface after C7 parameter setting is finished, C8 parameter column flashes.
C8 parameter setting interface
C8 is motor operating temperature display setting, the setting range is 0 or 1, hold
button (UP) or button (DOWN) shortly for selection. C8 parameter definition table
Page 31
ELECTRIC BICYCLE METER KTLCD3 Product User Manual
- 30 -
C8 value
Motor operating temperature
0
Function off
1
Function on
Please Note:The motor operating temperature display requires installing temperature
sensor in the motor, output temperature detection signal simultaneously.
After finishing C8 parameter setting, hold button (SW) shortly to save the current set values and enter C9 parameter setting interface.
C9 Startup Password Setting
Enter C9 parameter setting interface after C8 parameter setting is finished, C9 parameter column flashes.
C9 parameter setting interface
C9 is meter power-on password setting, the default value is 0, hold button (UP)
or button (DOWN) shortly for selection. C9 parameter definition table
C9 value
Startup password setting
0
Function off
1
Function on
When C9 setting is 1, hold button (SW) shortly, indicating that the password function is startup, and then enter the password settings interface, three password setting
columns flash.
Page 32
ELECTRIC BICYCLE METER KTLCD3 Product User Manual
- 31 -
Password Setting Interface
The password setting is done sequentially from left to right, hold button shortly to confirm after each setting and enter next setting. Password setting range is 000-999, hold
button (UP) or button (DOWN) shortly for selection.
Please note:If you forget your password, the parameters can only be copied (see
parameter copy) by data source meter prier to be decoded.
After finishing C9 parameter setting, hold button (SW) shortly to save the current set values and enter C10 parameter setting interface.
C10 Automatically Restore Factory Setting
Enter C10 parameter setting interface after C9 parameter setting is finished, C10 parameter column flashes.
C10 parameter setting interface
C10 is automatic restore factory settings, the default is n, and the setting can be n, or y,
hold button (UP) or button (DOWN) shortly for selection. C10 parameter definition table
C10 value
Restore default setting
n
Function off
y
Function on
Page 33
ELECTRIC BICYCLE METER KTLCD3 Product User Manual
- 32 -
When the meter is needed to restore default setting, C10 selects y, hold button long for about 2 seconds, all parameters restore default settings and exit setting
environment, and then return to the display1.
C10 selects n, hold button (SW) shortly to save the current set values and enter C11 parameter setting interface.
C11 Meter Attribute Selection Setting
Enter C11 parameter setting interface after C10 parameter setting is finished, C11 parameter column flashes.
C11 parameter setting interface
C11 is meter attribute selection setting, the setting range is 0-2, hold button
(UP) or button (DOWN) shortly for selection. C11 parameter definition table
C11
value
Meter Attribute
0
Meter uses LCD3 new version of communication protocol, it is compatible
LCD1 and LCD2.
1
Meter uses LCD1 and LCD2 old version communication protocol, it is not
compatible LCD3.
2
As data source for copying parameters, the meter transfers the new LD3
parameter to other meters.
C11 selects 2, hold (SW) long for about 2 seconds to exit the setting environment, and then the meter is served as data source for copying parameter (see
Page 34
ELECTRIC BICYCLE METER KTLCD3 Product User Manual
- 33 -
parameter copy), there’s source logo on display interface.
Data Source Display Interface
After finishing C11 parameter setting, hold button (SW) shortly to save the current set values and enter C12 parameter setting interface.
C12 Controller Minimum Voltage Adjustment Setting
Enter C12 parameter setting interface after C11 parameter setting is finished, C12 parameter column flashes.
C12 parameter setting interface
C12 is controller minimum operating voltage adjustment setting (tiny adjustment of
voltage shortage), the default value is 4, and the setting range is 0-7, hold button
(UP) or button (DOWN) shortly for selection. C12 parameter definition table
C12 value
Minimum Voltage(V)
24V Controller
36VController
48VController
0
Default value-2V
Default value-2V
Default value-2V
1
Default value-1.5V
Default
value-1.5V
Default
value-1.5V
Page 35
ELECTRIC BICYCLE METER KTLCD3 Product User Manual
- 34 -
2
Default value-1V
Default value-1V
Default value-1V
3
Default value-0.5V
Default
value-0.5V
Default
value-0.5V
4
Default value 20V
Default value
30V
Default value
40V
5
Default value+0.5V
Default
value+0.5V
Default
value+0.5V
6
Default value+1V
Default value+1V
Default value+1V
7
Default value+1.5V
Default
value+1.5V
Default
value+1.5V
C12 default value is 4, namely, controller minimum operating voltage (voltage shortage value); when setting is 5, the default value plus 0.5V, when setting is 4, the default value minus 0.5Vand so on.
After finishing C12 parameter setting, hold button (SW) shortly to save the current set values and enter C13 parameter setting interface.
C13 ABS brakes of the controller and parameters of anti-charge control Setting
Enter into C13 parameter setting interface, C13 parameter bar flashes.
C13 parameter setting interface
C13 is ABS brakes of the controller and parameters of anti-charge control setting, the
default value is 0 with the setting range between 0-5, press (UP) button or
(DOWN) button to make selection.
Page 36
ELECTRIC BICYCLE METER KTLCD3 Product User Manual
- 35 -
C13 parameter definition table:
C13 Value
ABS braking strength
Energy recovery efficiency
0
None
None
1
Class 1 braking strength
Best energy recovery
efficiency
2
Class2 braking strength
General energy recovery
efficiency
3
Class 3 braking strength
Weaker energy recovery
efficiency
4
Class4 braking strength
Poor energy recovery
efficiency
5
Class5 braking strength
Bad energy recovery
efficiency
The recommended value of C13 is 1; other values need to be chosen with caution for use.
Be sure to note: the higher is the braking intensity level, and the braking strength
will be greater, the greater damage to the motor shaft accordingly.
After finishing the parameter setting of C13, press (SW) button for short to enter C14 parameter setting interface.
C14 Power-assist tuning parameters Setting
Enter into C14 parameter setting interface, C14 parameter bar flashes.
C14 parameter setting interface
C14 is the parameters of power-assist tuning setting, with the default value of 2. The power-assist is between1-4 gear, and it is invalid until P3 equals to 1. The setting range 1-3,
and press (UP) button or (DOWN) button for short to make selection. C14 parameter definition table:
C14 Value
Assist strength of intelligent pedal motor
1
Weak assist strength of motor
2
General assist strength of motor
3
Stronger assist strength of motor
After finishing C14 parameter setting, hold button (SW) shortly to save current
Page 37
ELECTRIC BICYCLE METER KTLCD3 Product User Manual
- 36 -
set values and enter C1 parameter setting interface again. Or hold button (SW) long for about 2 seconds to exit C parameter setting environment and return to the display 1.
Exit C Parameter Setting
Among the fourteen C parameter settings, when each parameter setting is completed,
if held button (SW) long for about 2 seconds, all can exit the setting environment and return to display 1, meanwhile, the current set parameters would be saved.
Under each parameter setting interface, if there’s no button operation on the meter for more than 1 minute, and then the meter will automatically return to display 1, and the original set parameters will be saved.
Parameter Copy
Set parameters (include general project parameter, P parameter and C parameter) of all KT-LCD3 meter produced by our company according to requirements, and set the meter to be a data source according to the method of "C11 meter attribute selection setting".
Use special wiring cables to properly wire to LCD3 meter needs to be copied according to the diagram.
Meter parameter copy wiring diagram
Page 38
ELECTRIC BICYCLE METER KTLCD3 Product User Manual
- 37 -
Special wiring cable
Turn on meter power supply of data source. Power supply of 48V or 36V or 24V is available (VB + positive power supply). After wiring the meter needs to be copied, hold
button long till meter is startup. Within 5 seconds after startup, hold button
(UP) and button (DOWN) simultaneously for about 2 seconds, meter parameter copy is completed. If the copy operation is correct, the meter subject to be copied will display as follow.
Interface of finishing parameter copy
Please note: Both C9 power-on password and C11 meter attributes can’t be copied.
Besides, LCD3 meter can only copy parameter of the same meter model.
User Setting Note
After entering the user setting environment, if there’s no button operation on the data for more than 1 minute, the meter will automatically return to display1, and the new set parameters won’t be saved.
The factory parameter set value and the default value of the meter can be set according to user requirements, the meter parameter can be restored by using "C10
Page 39
ELECTRIC BICYCLE METER KTLCD3 Product User Manual
- 38 -
automatically restore factory setting " approach when adjusting it.
Version Information
KT_LCD3_V3.0
Released on April 12, 2015
Loading...