Kubota J112-STD, J108-STD, J110-STD, J114-STD, J107-STD Operator's Manual

...
G3907-8911-5
ENGLISH
3
To prevent electrical shock the following instruction must be followed.
Before the generator can be connected to a building’s electrical system, a licensed electrician must install an isolation (transfer) switch in the building’s main fuse box. The switch is the connection point for generator power and allows selection of generator or main line power to the building. This will prevent the generator from charging the main power line (backfeeding) when the main power supply has failed or has been turned off for line repair. Backfeeding can electrocute or injure line maintenance personnel. Also, generator and building electrical system damage can occur when normal operating power returns if unit is used without an isolation switch.
WARNING
FOREWORD
You are now the proud owner of a KUBOTA Diesel Engine Generator. This gen­erator is a product of KUBOTA quality engineering and manufacturing. It is made of fine materials and under a rigid quality control system with correct maintenance. It will give you long, satisfactory service. To obtain the best use of your generator, please read this manual carefully. It will help you become familiar with the operation of the generator and contains many helpful hints about generator maintenance. It is KUBOTA's policy to utilize as quickly as possible every advance in our research. The immediate use of new techniques in the manufacture of products may cause some small parts of this manual to be outdated. KUBOTA distributors and dealers will have the most up-to-date information. Please do not hesitate to consult with them.
ENGLISH
3
This symbol, the industry's "Safety Alert Symbol", is used throughout this manual and on labels on the machine itself to warn of the possibility of personal injury. Read these instructions carefully. It is essential that you read the instruc­tions and safety regulations before you attempt to assemble or use this unit.
3 3 3
IMPORTANT : Indicates that equipment or property damage could result
NOTE : Gives helpful information.
DANGER : Indicates an imminently hazardous situation which, if not
avoided, will result in death or serious injury.
WARNING : Indicates a potentially hazardous situation which, if not
avoided, could result in death or serious injury.
CAUTION: Indicates a potentially hazardous situation which, if not
avoided, may result in minor or moderate injury.
if instructions are not followed.
SAFETY FIRST
CONTENTS
SAFE OPERATION .................................................................................................. 1
SERVICING OF GENERATOR....................................................................................1
SPECIFICATIONS .......................................................................................................2
1 Phase Type ................................................................................................................... 2
3 Phase Type ................................................................................................................... 5
NOMENCLATURE ....................................................................................................... 8
Control Panel.................................................................................................................. 10
Easy Checker ................................................................................................................. 13
Control Box.....................................................................................................................13
PREPARATION TO SUPPLY THE ELECTRIC POWER...........................................14
CONNECTING THE LOAD ........................................................................................16
Connection Notes........................................................................................................... 16
Connecting the Load (Standard Model) ......................................................................... 16
Connecting the Load (AUS Model)................................................................................. 18
HANDLING THE CIRCUIT BREAKER.......................................................................19
Handling the Circuit Breaker (Protector) (Australian model) .......................................... 19
PRE-OPERATION CHECK ........................................................................................20
DAILY CHECK........................................................................................................20
Battery ............................................................................................................................ 20
Engine Oil....................................................................................................................... 21
Coolant ........................................................................................................................... 21
Fuel ................................................................................................................................ 21
ENGLISH
OPERATING THE GENERATOR .............................................................................. 22
Starting the Engine......................................................................................................... 22
Cold Weather Starting .................................................................................................... 24
Stopping the Engine ....................................................................................................... 25
If the Engine Fails to Stop in the Usual Procedure (EMERGENCY STOP) ................... 25
MAINTENANCE ......................................................................................................... 27
SERVICE INTERVALS ...........................................................................................27
PERIODIC SERVICE .................................................................................................29
FUEL ...................................................................................................................... 29
Fuel Level Check and Refueling .................................................................................... 29
Air Bleeding the Fuel System ......................................................................................... 30
Checking the Fuel Pipes ................................................................................................ 31
Cleaning the Fuel Filter Pot ............................................................................................ 31
ENGINE OIL ........................................................................................................... 32
Checking Oil Level and Adding Engine Oil..................................................................... 32
Changing Engine Oil ...................................................................................................... 33
Replacing the Oil Filter Cartridge ................................................................................... 34
AIR CLEANER........................................................................................................34
Cleaning Secondary Air Filter Element .......................................................................... 34
Cleaning Primary Air Filter Element ............................................................................... 35
Evacuator Valve ............................................................................................................. 35
For the Air Cleaner with a Dust Cup............................................................................... 35
RADIATOR ............................................................................................................. 36
Checking Coolant Level, Adding Coolant....................................................................... 36
ENGLISH
CONTENTS
Changing Coolant........................................................................................................... 37
Remedies for quick decrease of coolant ........................................................................ 37
Checking Radiator Hoses and Clamps .......................................................................... 38
Precaution Overheating.................................................................................................. 38
Cleaning Radiator Core (outside) ................................................................................... 38
Cleaning the Radiator..................................................................................................... 38
Anti-freeze ...................................................................................................................... 38
BATTERY ............................................................................................................... 39
Battery Charging ............................................................................................................ 39
Instructions for Long Term Storage ................................................................................ 41
Battery Boost Starting .................................................................................................... 41
ELECTRIC WIRING ............................................................................................... 41
PERIODIC SERVICING AND CLEANING OF THE GENERATOR........................42
FUSE ...................................................................................................................... 44
FAN BELT ..............................................................................................................45
Adjusting Fan Belt Tension ............................................................................................ 45
TRANSPORTING / STORAGE ..................................................................................46
Transporting ................................................................................................................... 46
Storage........................................................................................................................... 46
TROUBLESHOOTING ...............................................................................................47
Generator .......................................................................................................................47
Easy Checker ................................................................................................................. 48
Engine ............................................................................................................................ 48
AUTOMATIC START/STOP UNIT (A S/S UNIT) ....................................................... 50
WIRING DIAGRAM .................................................................................................... 51
SAFE OPERATION
Careful operation is your best insurance against an accident. Read and understand this operator’s manual carefully before operating the generator. All operators, no matter how much experience they may have had, should read this manual and all labels on the generator before operating the generator. It is the owner's responsibility to instruct all operators in safe operation.
Be sure to observe the following for safe operation.
OBSERVE SAFETY INSTRUCTIONS
A Read and understand carefully this OPERATOR'S
MANUAL and LABELS ON THE GENERATOR before attempting to start and operate the generator.
A Learn how to operate and work safely. Know your
equipment and its limitations. Always keep the generator in good condition.
A Before allowing other people to use your generator,
explain to them how to operate and have them read this manual before operation.
A DO NOT modify the engine by yourself.
UNAUTHORIZED MODIFICATIONS to the engine may impair the function and / or safety and affect engine life.
1SAFE OPERATION
ENGLISH
WEAR SAFETY CLOTHING
A DO NOT wear loose, torn or bulky clothing around the
generator that may catch on working controls and projections causing personal injury.
A Use additional safety items, e.g. hard hat, safety
protections, gloves, etc., as appropriate or required.
A DO NOT operate generator or any equipment attached to
it while under the influence of alcohol, medication, or other substances, or while fatigued.
A DO NOT wear radio or music headphones while
operating the generator.
SAFE OPERATION2
CHECK BEFORE OPERATION & STARTING THE ENGINE
ENGLISH
A Always turn off the circuit breaker and all switches for the
electrical devices before starting the generator.
A Check the wiring and connections of the electrical
devices before starting the generator.
A Be sure to check the engine before operation. If
something is wrong with the engine, repair it immediately and before operation.
A Keep all guards and shields in place before operating the
generator. Replace any that are damaged or missing.
A Check to see that bystanders are in a safe distance from
the generator before starting.
A Always keep the generator at least 1 m away from
buildings and other facilities.
A DO NOT allow children or livestock to approach the
generator while the engine is running.
A DO NOT start the engine by shorting across starter
terminals or bypassing normal starting circuit. The generator may start unexpectedly causing electric shock to others.
HANDLING ELECTRICAL COMPONENTS
Always exercise extra caution when handling electrical equipment. Careless handling of electrical components can cause serious personal injury, death by electrocution or property damage.
A DO NOT touch the electrical system during operation. A Connect or disconnect the load to the AC receptacles or
terminals only when the engine is stopped.
A Make certain that all power cables and wiring are in good
condition. Bare wire or frayed insulation can cause dangerous electrical shock, burns or death.
A DO NOT use the generator in damp or wet conditions.
Handling terminals and cables with wet hands can result in personal injury or death.
A Always shut the engine off and allow to cool before
cleaning. Use water sparingly when cleaning the outside of the generator. Make sure that water does not splash onto the electrical system or into the generator.
A DO NOT touch the generator with wet hands. You may
get an electric shock that can cause burns or death.
A DO NOT connect this generator to any building's
electrical system unless an isolation switch has been installed by a licensed electrician.
A DO NOT run other generators in parallel.
KEEP THE AREA AROUND THE ENGINE CLEAN
A Be sure to stop the engine before cleaning. A Keep the engine clean and free of accumulated dirt,
grease and trash to avoid a fire. Store flammable fluids away from sparks and fire.
A DO NOT stop the engine without idling. Sudden stops
can cause temperatures around the engine to rise suddenly. Keep the engine idling for about 5 minutes before stopping.
SAFE HANDLING OF FUEL AND LUBRICANTS
A Always stop the engine before refueling and/or
lubricating.
A DO NOT smoke or allow flames or sparks in the working
area. Fuel is extremely flammable and explosive under certain conditions.
A Refuel only when the engine has cooled off. Refuel in a
well ventilated and open place. When fuel and lubricants are spilled, clean them up before starting the engine.
A DO NOT mix gasoline or alcohol with diesel fuel. The
mixture can cause a fire and damage engine components.
A Operate the generator on a firm and level surface only.
DO NOT tilt or move the generator while it is running since this can cause fuel spillage.
3SAFE OPERATION
ENGLISH
SAFE OPERATION4
EXHAUST GASES & FIRE PREVENTION
ENGLISH
A Engine exhaust fumes can be very harmful if allowing
them to accumulate. Be sure to run the engine in a well ventilated place and where there are no people or livestock near the generator.
A DO NOT operate the generator in a closed area such as
inside houses, warehouses, tunnels, wells, ship holds, tanks, etc. or places without proper ventilation.
A DO NOT operate the generator where the building or
other obstructions block off air circulation or where exhaust gas can accumulate.
A The exhaust gas from the muffler is very hot. To prevent
a fire, DO NOT expose to dry grass, papers, oil and any other combustible materials to exhaust gas. Also, keep the engine and muffler clean at all times.
A To avoid fire, be alert for leaks of flammables from hoses
and lines. Be sure to check for leaks from hoses or pipes, such as fuel and engine oil by following the maintenance check list.
A To avoid a fire, DO NOT short across power cables and
wires. Check to see that all power cables and wiring are in good condition.
A Keep all power connections clean and tight. Bare wire or
frayed insulation can cause a dangerous electrical shock and personal injury.
HANDS AND BODY AWAY FROM THE ROTATING PARTS
A DO NOT operate the generator with the side covers
removed or open. Serious personal injury may result if fingers or clothing are caught in the rotating parts.
A Be sure to stop the engine before checking or adjusting
belt tension and cooling fan.
A To avoid personal injury, keep your hands and body
away from the rotating parts, such as cooling fan, V-belt, fan drive V-belt, pulleys or flywheel.
A DO NOT run the engine with installed safety guards
detached. Install safety guards securely before operation.
ESCAPING FLUID
A Relieve all pressure in the oil and the cooling systems
before any lines, fittings or related items are removed or disconnected.
A Be alert for possible pressure when disconnecting any
device from a system that utilizes pressure. DO NOT check for pressure leaks with your hand. High pressure oil or fuel can cause serious personal injury.
A Escaping fluid under pressure has sufficient force to
penetrate skin causing serious personal injury.
A Fluid escaping from pinholes may be invisible.
Use a piece of cardboard or wood to search for suspected leaks: DO NOT use hands or body. Use safety goggles or other eye protection when checking for leaks.
A If injured by escaping fluid, see a medical doctor at once.
This fluid can produce gangrene or severe allergic reaction.
5SAFE OPERATION
ENGLISH
SAFE OPERATION6
CAUTIONS AGAINST BURNS & BATTERY EXPLOSION
ENGLISH
A To avoid burns, be alert for hot components, e.g. muffler,
muffler cover, radiator, pipes, hoses, engine body, coolant, engine oil, etc. during operation and just after the engine has been shut off.
A DO NOT remove the radiator cap while the engine is
running or immediately after stopping. Otherwise hot water from the radiator will escape under pressure causing injury by scalding. Wait for more than 10 minutes to allow the coolant to cool down, before removing the cap.
A Make sure to close the drain valve of coolant and engine
oil, close radiator pressure cap and tighten hose clamps before operating. If any of these parts are taken off, or left loose, serious personal injury can result.
A The battery presents an explosive hazard. When the
battery is being activated, hydrogen and oxygen gases are extremely explosive.
A Keep sparks and open flames away from the battery,
especially when charging the battery. DO NOT strike a match near the battery.
A DO NOT check battery charge by placing a metal object
across the terminals. Use a voltmeter or hydrometer.
A DO NOT charge battery if frozen, there is a risk of
explosion. When battery is frozen, allow the battery to warm up to 16 C (61 F) before charging.
A DO NOT use or charge the battery if its fluid level is below
the LOWER (lower limit level) mark (refillable type battery only). Otherwise, the component parts may deteriorate earlier than expected, which may shorten the service life or cause an explosion. Add distilled water until the fluid level
CONDUCTING SAFETY CHECKS & MAINTENANCE
A Know how to stop the generator quickly, and understand
operation of all the controls. DO NOT permit anyone to operate the generator without proper instruction.
A When checking engine or servicing, place the generator
in an open area and level ground. DO NOT work on anything that is supported ONLY by lift jacks or a hoist. Always use blocks or safety stands to support the generator before servicing.
A Detach the battery from the generator before conducting
service. Put a “DO NOT OPERATE!” tag on the key switch and remove the key to avoid accidental starting.
A To avoid sparks from an accidental short circuit, always
disconnect the battery’s ground cable (-) first and connect it last.
A Sulfuric acid in battery electrolyte is poisonous. It is
strong enough to burn skins and clothing and cause blindness if splashed into eyes. Keep electrolyte away from eyes, hands and clothing. If you spill electrolyte on yourself, flush with water, and get medical attention immediately.
A Be sure to stop the engine and remove the key when
conducting daily and periodic maintenance, servicing and cleaning.
A Check or conduct maintenance after the engine, coolant,
muffler, or muffler cover have cooled off completely.
A Always use the appropriate lifting equipment and make
sure safety stands are in good condition when performing any service work. Make sure that you understand how to use the equipment before servicing.
A Use ONLY the correct engine flywheel rotating
techniques for manually rotating the engine. DO NOT attempt to rotate the engine by pulling or prying on the cooling fan or V-belt. This practice can cause serious personal injury or premature machine damage to the cooling fan.
A Replace fuel, lubricant and coolant hoses with their hose
clamps every 2 years or earlier if required. They are made of rubber and deteriorate over time whether used or not.
A When servicing is performed together by two or more
persons, take care to perform all work safely.
A Keep first aid kit and fire extinguisher handy at all times.
7SAFE OPERATION
ENGLISH
SAFE OPERATION8
DANGER, WARNING AND CAUTION LABELS
ENGLISH
Pay special attention to all labels on the generator. Refer to following representations for labels used on the J-Series Generator. Labels are available individually from your KUBOTA Dealer.
(1) Part No. G3907-8832-0 (2) Part No. G3907-8830-0
(3) Part No. G3907-8836-0 (4) Part No. G3907-8831-0
(5) Part No. 18901-5090-2
(6) Part No. G3907-8824-0
(7) Part No. 18620-8806-0 (8) Part No. G3907-8833-0
9SAFE OPERATION
ENGLISH
For the Z482 or D722-mounted machines only.
SAFE OPERATION10
CARE OF DANGER, WARNING AND CAUTION LABELS
ENGLISH
1. Keep danger, warning and caution labels clean and free from obstructing material.
2. Clean danger, warning and caution labels with soap and water, dry with a soft cloth.
3. Replace damaged or missing danger, warning and caution labels with new labels from your local KUBOTA Dealer.
4. If a component with danger, warning and caution label(s) affixed is replaced with new part, make sure new label(s) is (are) attached in the same location(s) as the replaced component.
5. Mount new danger, warning and caution labels by applying on a clean dry surface and pressing any bubbles to outside edge.
SERVICING OF GENERATOR
Your dealer is interested in your new generator and has the desire to help you get the most value from it. After reading this manual thoroughly, you will find that you can do some of the regular maintenance yourself. However, when in need of parts or major service, be sure to see your KUBOTA Dealer. For service, contact the KUBOTA Dealership from which you purchased your generator or your local KUBOTA Dealer.
When in need of parts, be prepared to give your dealer the generator and engine serial numbers. Locate the serial numbers now and record them in the space provided below.
1SERVICING OF GENERATOR
ENGLISH
Model Serial No.
Generator
Engine
Date of Purchase
Name of Dealer
(To be filled in by purchaser)
[Engine model : D1005, V1305]
[Engine model : Z482, D722]
(1) Generator serial number (2) Generator model (3) Engine serial number
2 SPECIFICATIONS
SPECIFICATIONS
ENGLISH
MOKUJIYOU
B1 Phase Type
GENERATOR
Model Unit
Design
Frequency Hz 50 60 50
Rated Output (COP)
Rated Voltage V 220 240 110/220 127/220 220 240 Phase & Wire φ-w 1-2 1-3 1-2 Power Factor % 100 No. of Poles - 2 Insulation - Rotary coil: Class F, Stator coil: Class B Voltage Regulation % 7 (No load to full load) Type of Coupling Direct coupled
DIESEL ENGINE
Model Z482-B-SEC D722-B-SEC Design Vertical, water-cooled, 4-cycle diesel engine No. of cylinders 2 3 Bore x stroke mm φ67 x 68 φ67 x 68 Displacement L 0.479 0.719 Engine speed rpm 3000 3600 3000 Lubricating Oil API service class CD or higher Oil capacity L 2.2 3.4 Coolant capacity L 2.3 3.0
SET
kVA 5.5 6.5 8
kW 5.5 6.5 8
J106 J107 J108
-STD -AUS -STD -SA -STD -AUS Salient-pole, revolving-field AC generator
(AVR system with separate and self-excitation brush)
Fuel Diesel fuel No. 2 (ASTM D975) Fuel consumption (at full load) L 2.3 2.8 3.2 Fuel tank capacity L 37 37 Continuous Operating Hours hrs 16.0 13.2 11.5
Battery (V x Ah/5Hr)
Starting System Electric
L x W x H (with wheel) mm
Approx Net Wt. kg 225 255
Output
Option Caster ­Sound Level (full load at 7m) dB(A) 74.0 76.0 75.0 Emergency Stop System - In case of abnormal: Oil pressure, water temperature
AMPS
AMPS A 25.0 22.9
Terminal - - ­Receptacle - - - - -
38B20R
(12V x 28Ah)
923 x 593 x 860
(1037)
59.1/
29.5
51.2/
29.5
55B24R
(12V x 36Ah)
995 x 593 x 860
(1037)
36.4 33.3
GENERATOR
3SPECIFICATIONS
Model Unit
Design
Frequency Hz 60 50 60
kVA 10 12 14
Rated Output (COP)
kW 10 12 14
Rated Voltage V 110/220 127/220 220 240 110/220 127/220 Phase & Wire φ-w 1-3 1-2 1-3 Power Factor % 100 No. of Poles - 2 Insulation - Rotary coil: Class F, Stator coil: Class B
Voltage Regulation %
Type of Coupling Direct coupled
DIESEL ENGINE
Model D722-B-SEC D1005-BG-SEC Design Vertical, water-cooled, 4-cycle diesel engine No. of cylinders 3 Bore x stroke mm φ67 x 68 φ76 x 73.6 Displacement L 0.719 1.001 Engine speed rpm 3600 3000 3600 Lubricating Oil API service class CD or higher Oil capacity L 3.4 4.3 Coolant capacity L 3.0 3.3
SET
J110 J112 J114
-STD -SA -STD -AUS -STD -SA Salient-pole, revolving-field AC generator
(AVR system with separate and self-excitation brush)
11.5/
14.0
11.5/
14.0
7 (No load to full
load)
8 (No load to full load)
ENGLISH
Fuel Diesel fuel No. 2 (ASTM D975) Fuel consumption (at full load) L 4.2 4.5 5.8 Fuel tank capacity L 37 79 Continuous Operating Hours hrs 8.5 17.0 13.5
Battery (V x Ah/5Hr)
Starting System Electric
L x W x H (with wheel) mm
Approx Net Wt. kg 255 340
Output
Option Caster - ­Sound Level (full load at 7m) dB(A) 76.5 76.5 81.0
Emergency Stop System -
AMPS
AMPS A
Terminal - ­Receptacle---- --
55B24R
(12V x 36Ah)
995 x 593 x 860
(1037)
In case of
abnormal: Oil
pressure, water
temperature
90.9/
45.5
78.7/
45.5
In case of abnormal: Oil pressure, water
temperature, fan belt broken
54.5 50.0
80D26R(S)
(12V x 55Ah)
1215 x 611 x 922
63.6 x 2 /63.6
90.6/
63.6
4 SPECIFICATIONS
GENERATOR
Model Unit
ENGLISH
Design
Frequency Hz 50 60
kVA 16 18.8 11.5/18.8
Rated Output (COP)
kW 16 18.8 11.5/18.8
Rated Voltage V 220 240 110/220 127/220 Phase & Wire φ-w 1-2 1-3 Power Factor % 100 No. of Poles - 2 Insulation - Rotary coil: Class F, Stator coil: Class B Voltage Regulation % 8 (No load to full load) Type of Coupling Direct coupled
DIESEL ENGINE
Model V1305-BG-SEC Design Vertical, water-cooled, 4-cycle diesel engine No. of cylinders 4 Bore x stroke mm φ76 x 73.6 Displacement L 1.335 Engine speed rpm 3000 3600 Lubricating Oil API service class CD or higher Oil capacity L 5.7 Coolant capacity L 3.5
SET
-STD -AUS -STD -SA
(AVR system with separate and self-excitation brush)
J116 J119
Salient-pole, revolving-field AC generator
Fuel Diesel fuel No. 2 (ASTM D975) Fuel consumption (at full load) L 6.0 7.5 Fuel tank capacity L 79 Continuous Operating Hours hrs 13.0 10.5 Battery (V x Ah/5Hr) 80D26R(S) (12V x 55Ah) Starting System Electric L x W x H (with wheel) mm 1300 x 611 x 922
Approx Net Wt. kg 380
Output
Option Caster - ­Sound Level (full load at 7m) dB(A) 77.5 82.0
Emergency Stop System -
AMPS
AMPS A 72.7 66.7
Terminal - ­Receptacle - - - -
In case of abnormal:
Oil pressure, water temperature, fan belt broken
85.5 x 2 /85.5
90.6/85.5
B3 Phase Type
5SPECIFICATIONS
GENERATOR
Model Unit
Design
Frequency Hz 50 60
Rated Output (COP)
Rated Voltage V 380 415 240 220 Phase & Wire φ-w 3-4 Power Factor % 80 80 100 80 No. of Poles - 2 Insulation - Rotary coil: Class F, Stator coil: Class B Voltage Regulation % 8 (No load to full load) Type of Coupling Direct coupled
DIESEL ENGINE
Model D722-B-SEC Design Vertical, water-cooled, 4-cycle diesel engine No. of cylinders 3 Bore x stroke mm φ67 x 68 Displacement L 0.719 Engine speed rpm 3000 3600 Lubricating Oil API service class CD or higher Oil capacity L 3.4 Coolant capacity L 3.0
SET
kVA 10 10 6 12.5
kW 8 8 6 10
-STD -AUS -STD Salient-pole, revolving-field AC generator
(AVR system with separate and self-excitation brush)
J310 J313
ENGLISH
Fuel Diesel fuel No. 2 (ASTM D975) Fuel consumption (at full load) L 3.2 4.2 Fuel tank capacity L 37 Continuous Operating Hours hrs 11.5 8.5 Battery (V x Ah/5Hr) 55B24R (12V x 36Ah) Starting System Electric L x W x H (with wheel) mm 995 x 593 x 860 (1037) Approx Net Wt. kg 255
Output
Option Caster ­Sound Level (full load at 7m) dB(A) 75.0 76.5 Emergency Stop System - In case of abnormal: Oil pressure, water temperature
AMPS
AMPS A 15.2 13.9 8.3 x 3 32.8
Terminal - ­Receptacle - - -
6 SPECIFICATIONS
GENERATOR
Model Unit
ENGLISH
Design
Frequency Hz 50 60
Rated Output (COP)
Rated Voltage V 380 415 240 220 Phase & Wire φ-w 3-4 Power Factor % 80 80 100 80 No. of Poles - 2 Insulation - Rotary coil: Class F, Stator coil: Class B Voltage Regulation % 8 (No load to full load) Type of Coupling Direct coupled
DIESEL ENGINE
Model D1005-BG-SEC Design Vertical, water-cooled, 4-cycle diesel engine No. of cylinders 3 Bore x stroke mm φ76 x73.6 Displacement L 1.001 Engine speed rpm 3000 3600 Lubricating Oil API service class CD or higher Oil capacity L 4.3 Coolant capacity L 3.3
SET
kVA 15 15 9 17.5
kW 12 12 9 14
-STD -AUS -STD Salient-pole, revolving-field AC generator
(AVR system with separate and self-excitation brush)
J315 J318
Fuel Diesel fuel No. 2 (ASTM D975) Fuel consumption (at full load) L 4.5 5.8 Fuel tank capacity L 79 Continuous Operating Hours hrs 17.0 13.5 Battery (V x Ah/5Hr) 80D26R(S) (12V x 55Ah) Starting System Electric L x W x H (with wheel) mm 1215 x 611 x 922 Approx Net Wt. kg 340
Output
Option Caster - ­Sound Level (full load at 7m) dB(A) 76.5 81.0
Emergency Stop System -
AMPS
AMPS A 22.8 20.9 12.5 x 3 45.9
Terminal - ­Receptacle - - -
In case of abnormal:
Oil pressure, water temperature, fan belt broken
GENERATOR
7SPECIFICATIONS
Model Unit
Design
Frequency Hz 50 60
Rated Output (COP)
Rated Voltage V 380 415 240 220 Phase & Wire φ-w 3-4 Power Factor % 80 80 100 80 No. of Poles - 2 Insulation - Rotary coil: Class F, Stator coil: Class B Voltage Regulation % 8 (No load to full load) Type of Coupling Direct coupled
DIESEL ENGINE
Model V1305-BG-SEC Design Vertical, water-cooled, 4-cycle diesel engine No. of cylinders 4 Bore x stroke mm φ76 x73.6 Displacement L 1.335 Engine speed rpm 3000 3600 Lubricating Oil API service class CD or higher Oil capacity L 5.7 Coolant capacity L 3.5
SET
kVA 20 20 10.8 23.5
kW 16 16 10.8 18.8
-STD -AUS -STD Salient-pole, revolving-field AC generator
(AVR system with separate and self-excitation brush)
J320 J324
ENGLISH
Fuel Diesel fuel No. 2 (ASTM D975) Fuel consumption (at full load) L 6.0 7.5 Fuel tank capacity L 79 Continuous Operating Hours hrs 13.0 10.5 Battery (V x Ah/5Hr) 80D26R(S) (12V x 55Ah) Starting System Electric L x W x H (with wheel) mm 1300 x 611 x 922 Approx Net Wt. kg 380
Output
Option Caster - ­Sound Level (full load at 7m) dB(A) 77.5 82.0
Emergency Stop System -
AMPS
AMPS A 30.4 27.8 15 x 3 61.7
Terminal - ­Receptacle - - -
In case of abnormal:
Oil pressure, water temperature, fan belt broken
8 NOMENCLATURE
NOMENCLATURE
ENGLISH
MOKUJIYOU
(1) Control panel (2) Hook (3) Coolant filling port (4) Fuel tank cap (5) Door (6) Engine oil drain plug (7) Air cleaner (8) Battery (9) Reserve tank (10) Fuel cock (11) Engine oil port (12) Oil dipstick (13) Oil filter cartridge (14) Radiator (15) Coolant drain plug (radiator) (16) Coolant drain plug (engine) (17) Fuel tank (18) Generator (19) Muffler (20) Base (21) Fork pockets (22) Fuel gauge (23) Terminal cover
(1) Control panel (2) Hook (3) Coolant filling port (4) Fuel tank cap (5) Door (6) Engine oil drain plug (7) Air cleaner (8) Battery (9) Reserve tank (10) Fuel cock (11) Engine oil port (12) Oil dipstick (13) Oil filter cartridge (14) Radiator (15) Coolant drain plug (radiator) (16) Coolant drain plug (engine) (17) Fuel tank (18) Generator (19) Muffler (20) Base (21) Fork pockets (22) Fuel gauge (23) Terminal cover
9NOMENCLATURE
ENGLISH
NOMENCLATURE10
BControl Panel
ENGLISH
Standard Model
C 1 Phase Type (220V Type)
[J106-STD, J108-STD]
[J112-STD, J116-STD]
C 1 Phase Type (110V/220V Dual voltage type)
[J107-STD, J110-STD]
[J114-STD, J119-STD]
(1) A.C. Voltmeter (2) Glow plug lamp (3) Water temperature lamp (4) Oil pressure lamp (5) Battery charge lamp (6) Main switch (key)
(7) Circuit breaker (8) Hour meter (9) Ground terminal (10) Terminal (Autostart unit) (11) Terminals (output)
(1) A.C. Voltmeter (2) Glow plug lamp (3) Water temperature lamp (4) Oil pressure lamp (5) Battery charge lamp (6) Main switch (key)
(7) Circuit breaker (8) Hour meter (9) Ground terminal (10) Terminal (Autostart unit) (11) Terminals (output)