KTM Manuals: Series PDS (Powder Discharge System) Ball Valve OSI, KTM-EN Manuals & Guides

KTM SERIES POWDER DISCHARGE SYSTEM (PDS) BALL VALVES
OPERATING AND SAFETY INSTRUCTION
Before installation these instructions must be read fully and understood
1 SCOPE OF APPLICATION
This instruction manual applies to the PDS ball valve.
2 HANDLING SUMMARY
In order to keep using the valve in good condition for long, carry out piping in ac-cordance with the following procedure.
a. Before installing the delivered product,
collate whether it meets specified opera­tional conditions (e.g. temperature, pressure, fluid property, environment, piping standard).
b. Check each section of the valve for
components such as bolts, and nuts. Make sure there is no loosening of each section caused by transportational vibration, etc. If a loose section is found, tighten it as required.
c. Since both flanges of the valve are covered
with dustproof seals, peel them off.
d. Before installing the valve, carry out
adequate flashing of pipe lines (inside of pipe line) to remove foreign matters. Installing and operating the valve to open and close leaving welding or cut chips unremoved inside pipes may threaten to cause damage to the ball and seat of the valve.
e. The valve can be mounted to a horizontal
or vertical pipe, or can be installed in any direction such as turning it sideways, except that the mounting attitude of the valve may be limited for maintenance or automatic operation.
f. When fastening flange bolts, alternately
fasten each pair of those opposite to each other toward the center of the flange by applying uniform strength with care for uneven fastening. Uneven fastening of flange bolts causes pipe stress, thereby damaging the flange, or inducing an excessive operating torque.
2.2 Checkup and maintenance
To make the valve perform its intrinsic function to the utmost end without fail, carry out periodic checkup and maintenance of it as required.
a. Valve seat The valve seat is made of stainless steel
deposited of stellite. In case unusu-ally excessive leakage occurs from the valve seat disassemble the valve to check for leakage from the surface of seat and ball.
Since a scratch or flaw on the surface of
ball or seat may cause excessive leakage from the vale seat, it is necessary to replace the seat or ball as re-quired. (Since the allowance for leakage from the valve seat is prescribed by the ANSI/FC170-2bCLASS 5, the KTM employs the allowance as standard.)
In addition, when reassembling the valve,
replace the gasket with a new one.
b. Mating face between the body and the
body cap
The mating face between the valve body and
the body cap uses a gasket. Make sure there is no leakage from the mating face. In case slight leakage occurs from the mating face, retighten bolts and nuts for the body cap. In case even slight leakage still continues, disassemble the valve, check the gasket to make sure of the presence or absence of abnormality, and replace the gasket as required.
Emerson.com/FinalControl © 2020 Emerson. All rights reserved. VCOSI-14922-EN 20/01
KTM SERIES POWDER DISCHARGE SYSTEM (PDS) BALL VALVES
OPERATING AND SAFETY INSTRUCTION
c. Gland seal The seal for the gland uses a packing made
of reinforced PTFE or Graphite. Since the gland is the sliding section of the stem, execute periodic checkup on the gland to make sure there is no leakage from the gland seal. In case even slight leakage occurs from the gland seal, retighten gland bolts uniformly to make sure the leakage has been stopped. In case the leakage still contin-ues, disassemble the valve to check for the packing, make sure of the pres-ence or absence of abnormality, and replace the packing as required.
d. Mating face between the valve body and the
lower cover
The mating face between the valve body and
the lower cover uses a gasket. Make sure there is no leakage from the mating face. In case even slight leakage occurs from the mating face, retighten bolts and nuts for the mating face. In case the leakage still continues, disassemble the valve, check for the gasket to make sure of the presence or absence of abnormality, and replace the gasket as required.
2.3 Cautions for disassembly and assembly of the valve
For the valve structure, see the drawing of delivery. When disassembling and assembling the valve, be careful for the following matters.
a. Since fluid (gas or liquid) pressure may be
left as it is inside the cavity of the valve body, discharge the pressure by open the drain plug, or open or close the valve to discharge the pressure from the cavity. After making sure there is no pressure inside the cavity any longer, disassemble the valve.
b. If fluid for use in the valve is physically
harmful, or strongly inflammable, clean the valve and pipes adequately so that no fluid remains inside the cavity of the valve body. After making sure there remains no fluid used inside, disassemble the valve. In this case, too, it is effective to repeat opening and closing the valve a number of times before disassembling and assembling the valve.
c. Handle the spherical surface of the ball and
each seal with care not to dent or flaw them.
d. In order to protect the spherical surface
of the ball and the seat from being dented or flaw, fully close the valve before disassembling or assembling it.
e. When assembling the valve, replace all the
gaskets, stem bearing and thrust bearing with new ones.
2.4 Disassembly
The following provides a procedure for disassembling the valve required for maintenance and checkup, or troubleshooting of the valve.
1. Removal of the actuator (pneumatic torque cylinder).
See drawing AE0106-7437 a. Shut off operational pneumatic pressure
and operational electric power supply, and remove the pneumatic piping and electric wiring from the ac-tuator.
b. Remove all of the attachments that
may threaten to be damaged by the
disassembly. c. Mark both yoke (2) and valve (1) with tally. d. Unfasten Hex Socket Head Bolt (7) from
connector and remove con-nector (3)
from the valve stem. e. Unfasten anchor nuts to remove both
actuator (4) and yoke (2) together from
valve (1).
2. Disassembly of the valve. See drawing HE0106-7477 a. Remove key (41) from stem (4), unfasten
nut (32) to remove gland flange (31)
from the valve. Next, unfasten nut (37) to
remove EXT. bonnet (13) from the valve.
(Then, removing the gland packing from
the valve makes the removal work easy.) b. Extract stem (4) from valve body (1) (Since there is a female threaded hole
on the top of stem (4), screwing an
eyebolt, or the like in the hole makes
the extraction easy. Moreover, the use
of a jig as shown in Figure 1 makes the
extraction easier.) c. Unfasten nut (39) to remove lower cover
(14) and shim (44). Next, extract lower
stem (5) from valve body (1). (Since there is a female threaded hole
on the under surface of lower stem (5),
screwing an eyebolt, or the like in the hole
makes the extraction easy. Moreover, the
use of a jig as shown in Figure 1 makes
the extraction easier.) d. Unfasten nut (35) to remove body cap
(2) from valve body (1). After that, ball
(3) from valve body (1) with care not to
scratch or flaw the spherical surface of
the ball. e. Remove seat (6), O-ring (9), spring holder
(7) and spring (8) from the valve body.
Then, be careful for spring (8) set in the
back of spring holder (7) not to be lost. f. Also, disassemble seat (6) attached to
body cap (2) in the same manner as the
procedure described in step (e) above.
2
Loading...
+ 2 hidden pages