Panel Mounting Bracket
KSD-800
Industrial 8-Port Fast Ethernet Switches 
with Fiber Connectivity
Benefits :
 Fast Ethernet switch with 8 10/100Mbps copper ports and optional fiber ports
 Wide operating temperature range for temperature critical environment
 Support DIN rail mounting and panel mounting
 Provide two power input types to meet more application needs
 Accept wide power input voltage range for application flexibility
 Industrial-rated Emission and Immunity performance
Key Features :
 8 10/100M ports support auto-negotiation and auto-MDI/MDI-X configuration
 Port 7 and Port 8 provide either copper or fiber connection (model dependent)
 Provides wire speed store-and-forward switching
 Supports IEEE 802.3x flow control for full-duplex operation
 Supports Back-pressure flow control for half-duplex operation
 Provides Far End Fault function on the fiber ports
Specifications : 
Standard   IEEE 802.3 10Base-T, IEEE 802.3u 100Base-TX, 100Base-FX
Network Ports   8 RJ-45 10/100Mbps auto-negotiation, auto-MDI/MDI-X ports 
     2 100Mbps 100Base-FX ports (model depedent) 
     (Port 7 and Port 8 provide dual connectivities, either copper or fiber.)
Network Cables  10Base-T :  Cat. 3, 4, 5 or higher up to 100m 
     100Base-TX : Cat. 5 or higher up to 100m 
     100Base-FX : MMF 50/125µm 60/125µm, SMF 9/125µm
MAC Addresses   Table with 1K entries
LEDs   Per unit :     Power, Management 
     Per 10/100M port :  Link/Activity, 100M, Duplex/Collision status 
     Per fiber port slot :  Link/Activity status status
Relay Output   Alarm :  Power failure 
     Interface : 2 terminal contacts 
     Spec. :  30VDC/1A max. or 120VAC/0.5A max.
DC Power Input   Screwed terminator block : 2 pairs of +/- contacts 
     DC jack :        -D 6.3mm / + D 2.0mm 
    Operating voltage range :  +7 - +30VDC
Power Consumption  7.3 watts (max.)
Housing   Enclosed metal with no fan
Dimension   140 x 106 x 40 mm (WxDxH)
Mounting Support  DIN Rail mounting, Panel mounting
080110

EMI EMS Safety Environmental Tests:
Test
FCC/EMI
CE/EMC/EMI
CE/EMC/Harmonic
CE/EMC/VFF
CE/EMC/EMS
ESD Test
RS Test
EFT/BURST
Surge Immunity
CS Test
Magnetic Field Imm.
Voltage Dips Imm.
Safety
Dielectric Voltage
Insulation Resistance
Cold Test
Dry Heat Test
Damp Heat Test
Storage Test
Vibration Test
Standard
FCC Rule Part 15
EN55022, CISPR 22
EN 61000-3-2
EN 61000-3-3
EN 55024
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6
IEC 61000-4-8
IEC 61000-4-11
EN 60950, IEC 60950
IEEE 802.3
IEEE 802.3
IEC 68-2-1 Test Ad
IEC 68-2-2 Test Bd
IEC 68-2-3
IEC 68-2-48
IEC 68-2-34
Specifications
Class A
Class A
< 75 W
Clause 5
Contact:+/-8KV
Air:+/-16KV
Strength:10V/m
+/-4KV
Power:4KV
Signal:0.5KV
Level 3
50Hz 40A/m
Interruption : C
Dips : B
TP, 1500VAC/60sec.
TP, 500VDC/10Mohm
O
-20
C, 96hrs
O
+70
C 40%RH 96hrs
O
C 90%RH 96hrs
+60
O
C 96hrs
-20
O
+85
C 40%RH 96hrs
Ordering Information :
Operating
Model
KSD-800-xxx
-1T
-1C 
-2T
-2C
-2C1
-2SA2
-2SL2
-C1SL2
FX Ports
FX8 ST MMF
FX8 SC MMF
FX8 SC MMF-1C1 
FX8 SC SMF-1SA2  20km
FX8 SC SMF-1SL2  20km
FX7 ST MMF 
FX8 ST MMF
FX7 SC MMF 
FX8 SC MMF
FX7 SC MMF 
FX8 SC MMF
FX7 SC SMF 
FX8 SC SMF
FX7 SC SMF 
FX8 SC SMF
FX7 SC MMF 
FX8 SC SMF
Ref.
Distance
2km
2km
2km
2km 
2km
2km 
2km
2km 
2km
20km 
20km
20km 
20km
2km
20km
Temperature
-10 ~ 70OC
-10 ~ 70OC
-20 ~ 70OC
-20 ~ 70OC
-20 ~ 70OC
-10 ~ 70OC
-10 ~ 70OC
-20 ~ 70OC
-20 ~ 70OC
-20 ~ 70OC
-20 ~ 70OC
Environment   Operating temperature : -20OC ~ 70OC 
   Storage temperature : -20OC ~ 85OC 
   Relative Humidity :  5% ~ 95% non-condensing
Approval  FCC Class A 
   CE/EMC Class A, EN60950 safety
Fiber Optical Specification :
Model  FX &Cable  Wavelength  Tx Power  Rx Sensitivity  Rx Max.Power
-1T  FX8 :ST MMF  1310nm  -19 ~-14 dBm  -31 dBm  -14 dBm
-1C  FX8 :SC MMF  1310nm  -19 ~-14 dBm  -31 dBm  -14 dBm
-1C1  FX8 :SC MMF  1310nm  -20 ~-14 dBm  -31 dBm  0 dBm
-1SA2  FX8 :SC SMF  1310nm  -15 ~-8 dBm  -31 dBm  -7 dBm
-1SL2  FX8 :SC SMF  1310nm  -15 ~-8 dBm  -30 dBm  -7 dBm
-2T  FX7 :ST MMF  1310nm  -19 ~-14 dBm  -31 dBm  -14 dBm 
  FX8 :ST MMF  1310nm  -19 ~-14 dBm  -31 dBm  -14 dBm
-2C  FX7 :SC MMF  1310nm  -19 ~-14 dBm  -31 dBm  -14 dBm 
  FX8 :SC MMF  1310nm  -19 ~-14 dBm  -31 dBm  -14 dBm
-2C1  FX7 :SC MMF  1310nm  -20 ~-14 dBm  -31 dBm  0 dBm 
  FX8 :SC MMF  1310nm  -20 ~-14 dBm  -31 dBm  0 dBm
-2SA2  FX7 :SC SMF  1310nm  -15 ~-8 dBm  -31 dBm  -7 dBm 
  FX8 :SC SMF  1310nm  -15 ~-8 dBm  -31 dBm  -7 dBm
-2SL2  FX7 :SC SMF  1310nm  -15 ~-8 dBm  -30 dBm  -7 dBm 
  FX8 :SC SMF  1310nm  -15 ~-8 dBm  -30 dBm  -7 dBm
-C1SL2  FX7 :SC MMF  1310nm  -20 ~-14 dBm  -31 dBm  0 dBm 
  FX8 :SC SMF  1310nm  -15 ~-8 dBm  -30 dBm  -7 dBm
FCC Part 15
CISPR 22 Class A
Class A
'
Katron Technologies Inc.
15F-7, No. 79, Sec. 1, Hsin Tai Wu Rd.,
Taipei Hsien, Taiwan.
Hsi-chih, 
Te l:886-2-2698-3878 
Fax:886-2-2698-3873 
E-mail:kti@ktinet.com.tw 
URL:http://www.ktinet.com.tw
KTI Networks Inc.
7400 Harwin Dr., Suite 120 Houston, 
Texas 77036 U.S.A. 
Te l:713-266-3891 
Fax:713-914-0555 
E-mail:kti@ktinet.com 
URL:http://ww
Trademarks: All brand names are trademarks or registered 
trademarks of their respective holders. 
This info
w.ktinet.com
rmation is subject to change without prior notice.
080110