
Panel Mounting Bracket
KSD-800
Industrial 8-Port Fast Ethernet Switches
with Fiber Connectivity
Benefits :
Fast Ethernet switch with 8 10/100Mbps copper ports and optional fiber ports
Wide operating temperature range for temperature critical environment
Support DIN rail mounting and panel mounting
Provide two power input types to meet more application needs
Accept wide power input voltage range for application flexibility
Industrial-rated Emission and Immunity performance
Key Features :
8 10/100M ports support auto-negotiation and auto-MDI/MDI-X configuration
Port 7 and Port 8 provide either copper or fiber connection (model dependent)
Provides wire speed store-and-forward switching
Supports IEEE 802.3x flow control for full-duplex operation
Supports Back-pressure flow control for half-duplex operation
Provides Far End Fault function on the fiber ports
Specifications :
Standard IEEE 802.3 10Base-T, IEEE 802.3u 100Base-TX, 100Base-FX
Network Ports 8 RJ-45 10/100Mbps auto-negotiation, auto-MDI/MDI-X ports
2 100Mbps 100Base-FX ports (model depedent)
(Port 7 and Port 8 provide dual connectivities, either copper or fiber.)
Network Cables 10Base-T : Cat. 3, 4, 5 or higher up to 100m
100Base-TX : Cat. 5 or higher up to 100m
100Base-FX : MMF 50/125µm 60/125µm, SMF 9/125µm
MAC Addresses Table with 1K entries
LEDs Per unit : Power, Management
Per 10/100M port : Link/Activity, 100M, Duplex/Collision status
Per fiber port slot : Link/Activity status status
Relay Output Alarm : Power failure
Interface : 2 terminal contacts
Spec. : 30VDC/1A max. or 120VAC/0.5A max.
DC Power Input Screwed terminator block : 2 pairs of +/- contacts
DC jack : -D 6.3mm / + D 2.0mm
Operating voltage range : +7 - +30VDC
Power Consumption 7.3 watts (max.)
Housing Enclosed metal with no fan
Dimension 140 x 106 x 40 mm (WxDxH)
Mounting Support DIN Rail mounting, Panel mounting
080110

EMI EMS Safety Environmental Tests:
Test
FCC/EMI
CE/EMC/EMI
CE/EMC/Harmonic
CE/EMC/VFF
CE/EMC/EMS
ESD Test
RS Test
EFT/BURST
Surge Immunity
CS Test
Magnetic Field Imm.
Voltage Dips Imm.
Safety
Dielectric Voltage
Insulation Resistance
Cold Test
Dry Heat Test
Damp Heat Test
Storage Test
Vibration Test
Standard
FCC Rule Part 15
EN55022, CISPR 22
EN 61000-3-2
EN 61000-3-3
EN 55024
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6
IEC 61000-4-8
IEC 61000-4-11
EN 60950, IEC 60950
IEEE 802.3
IEEE 802.3
IEC 68-2-1 Test Ad
IEC 68-2-2 Test Bd
IEC 68-2-3
IEC 68-2-48
IEC 68-2-34
Specifications
Class A
Class A
< 75 W
Clause 5
Contact:+/-8KV
Air:+/-16KV
Strength:10V/m
+/-4KV
Power:4KV
Signal:0.5KV
Level 3
50Hz 40A/m
Interruption : C
Dips : B
TP, 1500VAC/60sec.
TP, 500VDC/10Mohm
O
-20
C, 96hrs
O
+70
C 40%RH 96hrs
O
C 90%RH 96hrs
+60
O
C 96hrs
-20
O
+85
C 40%RH 96hrs
Ordering Information :
Operating
Model
KSD-800-xxx
-1T
-1C
-2T
-2C
-2C1
-2SA2
-2SL2
-C1SL2
FX Ports
FX8 ST MMF
FX8 SC MMF
FX8 SC MMF-1C1
FX8 SC SMF-1SA2 20km
FX8 SC SMF-1SL2 20km
FX7 ST MMF
FX8 ST MMF
FX7 SC MMF
FX8 SC MMF
FX7 SC MMF
FX8 SC MMF
FX7 SC SMF
FX8 SC SMF
FX7 SC SMF
FX8 SC SMF
FX7 SC MMF
FX8 SC SMF
Ref.
Distance
2km
2km
2km
2km
2km
2km
2km
2km
2km
20km
20km
20km
20km
2km
20km
Temperature
-10 ~ 70OC
-10 ~ 70OC
-20 ~ 70OC
-20 ~ 70OC
-20 ~ 70OC
-10 ~ 70OC
-10 ~ 70OC
-20 ~ 70OC
-20 ~ 70OC
-20 ~ 70OC
-20 ~ 70OC
Environment Operating temperature : -20OC ~ 70OC
Storage temperature : -20OC ~ 85OC
Relative Humidity : 5% ~ 95% non-condensing
Approval FCC Class A
CE/EMC Class A, EN60950 safety
Fiber Optical Specification :
Model FX &Cable Wavelength Tx Power Rx Sensitivity Rx Max.Power
-1T FX8 :ST MMF 1310nm -19 ~-14 dBm -31 dBm -14 dBm
-1C FX8 :SC MMF 1310nm -19 ~-14 dBm -31 dBm -14 dBm
-1C1 FX8 :SC MMF 1310nm -20 ~-14 dBm -31 dBm 0 dBm
-1SA2 FX8 :SC SMF 1310nm -15 ~-8 dBm -31 dBm -7 dBm
-1SL2 FX8 :SC SMF 1310nm -15 ~-8 dBm -30 dBm -7 dBm
-2T FX7 :ST MMF 1310nm -19 ~-14 dBm -31 dBm -14 dBm
FX8 :ST MMF 1310nm -19 ~-14 dBm -31 dBm -14 dBm
-2C FX7 :SC MMF 1310nm -19 ~-14 dBm -31 dBm -14 dBm
FX8 :SC MMF 1310nm -19 ~-14 dBm -31 dBm -14 dBm
-2C1 FX7 :SC MMF 1310nm -20 ~-14 dBm -31 dBm 0 dBm
FX8 :SC MMF 1310nm -20 ~-14 dBm -31 dBm 0 dBm
-2SA2 FX7 :SC SMF 1310nm -15 ~-8 dBm -31 dBm -7 dBm
FX8 :SC SMF 1310nm -15 ~-8 dBm -31 dBm -7 dBm
-2SL2 FX7 :SC SMF 1310nm -15 ~-8 dBm -30 dBm -7 dBm
FX8 :SC SMF 1310nm -15 ~-8 dBm -30 dBm -7 dBm
-C1SL2 FX7 :SC MMF 1310nm -20 ~-14 dBm -31 dBm 0 dBm
FX8 :SC SMF 1310nm -15 ~-8 dBm -30 dBm -7 dBm
FCC Part 15
CISPR 22 Class A
Class A
'
Katron Technologies Inc.
15F-7, No. 79, Sec. 1, Hsin Tai Wu Rd.,
Taipei Hsien, Taiwan.
Hsi-chih,
Te l:886-2-2698-3878
Fax:886-2-2698-3873
E-mail:kti@ktinet.com.tw
URL:http://www.ktinet.com.tw
KTI Networks Inc.
7400 Harwin Dr., Suite 120 Houston,
Texas 77036 U.S.A.
Te l:713-266-3891
Fax:713-914-0555
E-mail:kti@ktinet.com
URL:http://ww
Trademarks: All brand names are trademarks or registered
trademarks of their respective holders.
This info
w.ktinet.com
rmation is subject to change without prior notice.
080110