(C) 2005 KTI Networks Inc. All rights reserved. No part of this documentation may be reproduced in
any form or by any means or used to make any directive work (such as translation or transformation)
without permission from KTI Networks Inc.
KTI Networks Inc. reserves the right to revise this documentation and to make changes in content
from time to time without obligation on the part of KTI Networks Inc. to provide notification of such
revision or change.
The information contained in this document is subject to change without prior notice. Copyright (C). All
Rights Reserved.
TRADEMARKS
Ethernet is a registered trademark of Xerox Corp.
WARNING:
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant
to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This equipment generates,
uses, and can radiate radio frequency energy and if not installed and used in accordance with the
instruction manual may cause harmful interference in which case the user will be required to correct the
interference at his own expense.
NOTICE:
(1) The changes or modifications not expressively approved by the party responsible for compliance
could void the user's authority to operate the equipment.
(2) Shielded interface cables and AC power cord, if any, must be used in order to comply with the
emission limits.
CISPR A COMPLIANCE:
This device complies with EMC directive of the European Community and meets or exceeds the following
technical standard.
EN 55022 - Limits and Methods of Measurement of Radio Interference Characteristics of Information
Technology Equipment. This device complies with CISPR Class A.
WARNING: This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
CE NOTICE
Marking by the symbol indicates compliance of this equipment to the EMC directive of the Euro-
pean Community. Such marking is indicative that this equipment meets or exceeds the following technical standards:
EN 55022: Limits and Methods of Measurement of Radio Interference characteristics of Information
Technology Equipment.
EN 50082/1:Generic Immunity Standard -Part 1: Domestic Commercial and Light Industry.
EN 60555-2: Disturbances in supply systems caused by household appliances and similar electrical
equipment - Part 2: Harmonics.
• Supports concisely the status of port and easily port configuration
• Supports per port traffic monitoring counters
• Supports port mirror function
• Supports the static trunk function
• Supports 802.1Q VLAN
• Supports user management and limits one user to login
• Maximal packet length can be up to 9216 bytes for jumbo frame application
• Supports Broadcasting Suppression to avoid network suspended or crashed
• Supports to send the trap event while monitored events happened
• Supports default configuration which can be restored to overwrite the current configuration
which is working on via Web UI and Reset button of the switch
• Supports on-line plug/unplug SFP modules
• Supports Quality of Service (QoS) for real time applications based on the information taken from
Layer 2 to Layer 4, such as VoIP
• Built-in web-based management with convenient GUI for the user
-6-
Page 7
1.2 View of Web Smart 24-Port Gigabit Switch
The major user interface components on the front panel and rear panel are:
• LED indicatorsLED Display for system power status and port status
IEEE802.3x compliant for full duplex
Backpressure flow control for half duplex
Cable and Maximum Length:
Gigabit copperCat. 5 UTP cable Cat.5e recommended, up to 100m
Gigabit fiber50/125, 60/125 MMF, 9/125 SMF, distance (depending on the SFP transceiver)
Diagnostic LED:
System LED :Power
Port 1 - 24 10/100/1000M : Speed status
Port 1 - 24 LINK/ACT :Link status and activities
Port 23, 24 SFP :SFP fiber link status
Power Requirement: Voltage 100 - 240 VAC, Frequency 50/60 Hz, Consumption 30W
Ambient Temperature: Operating 0 to 50oC, Humidity 5% to 90%
Dimensions: 44(H) ( 442(W) ( 209(D) mm
Approval: Comply with FCC Part 15 Class A & CE Mark Approval
-8-
Page 9
1.4 Management Software Specifications
Interface : Web Http browsing
System configuration: IP address settings, system name, password, Auto-logout timer
Port configuration: Port operating mode, flow control
VLAN configuration
VLAN mode : disable, Port-based, 802.1Q Tag-based, Metro (predefined Port-based)
VLAN groups : up to 24 active groups, Group ID, description, VID, member ports
VID value range : 1 - 4094
Port VID range (PVID) : 1 - 4094
Per Port Ingress Rules : Forward packets with VID=PVID, Drop untagged packets
Per Port Egress Rules : Port Tagging mode, Untagging specific VID packets
Link Aggregation (Trunking) Configuration
Trunks : up to 8 groups
Trunk port members : up to 8 ports
Mirroring Function
Sniffer mode : Ingress traffic of the source ports
Sniffer port : one port
Source ports : multiple ports are allowed
Quality of Service (QoS)
Priority class : High and low
Per port classification options : 802.1p, IP ToS, IP DSCP, IP TCP/UDP Port (L4 base)
Bandwidth Control
Per port basis control
Ingress Rate control : All traffic rate, Unicast rate, Broadcast/Multicast rate
Egress Rate control : All traffic rate
Trap Event Control
System events : Cold boot, Warm boot
Port events : Port link up, port link down, Invalid login, Tx error, Rx error
Event counters
Max. Packet Length Control:
Per port basis control
Option : 1518, 1532, 9216 (Jumbo frame support)
Statistics Monitoring : Per port basis control, Simplified port statistics, Detailed port statistics
Status Monitoring: All configuration current settings, All port link status
To reduce the risk of bodily injury, electrical shock, fire, and damage to the equipment, observe the
following precautions.
• Do not service any product except as explained in your system documentation.
• Opening or removing covers may expose you to electrical shock.
• Only a trained service technician should service components inside these compartments.
• If any of the following conditions occur, unplug the product from the electrical outlet and replace
the part or contact your trained service provider:
- The power cable, extension cable, or plug is damaged.
- An object has fallen into the product.
- The product has been exposed to water.
- The product has been dropped or damaged.
- The product does not operate correctly when you follow the operating instructions.
• Do not push any objects into the openings of your system. Doing so can cause fire or electric
shock by shorting out interior components.
• Operate the product only from the type of external power source indicated on the electrical
ratings label. If you are not sure of the type of power source required, consult your service
provider or local power company.
2.2 Desktop Mounting
The switch can be mounted on a desktop or shelf. Make sure that there is proper heat dissipation from
and adequate ventilation around the device. Do not place heavy objects on the device.
2.3 Applying Power
One AC power cord which meets the specification of your country of origin was supplied with the
switch unit. The switch supports wide range of AC power input specifications as follows:
Power Rating : 100 ~ 240VAC, 50/60Hz, 30W max.
Voltage Range : 90 ~ 264VAC
Frequency : 47 ~ 63 Hz
2.4 SFP Transceiver Installation
Verify the following Steps when installing an SFP transceiver into an empty SFP port:
1. Use the SFP transceivers qualified only by switch manufacturer.
2. The switch supports Hot-plug installation of the SFP transceiver even when the switch is on.
3. Make sure the transceiver is seated in the SFP port securely.
4. Install the fiber cable after the transceiver installation.
-10-
Page 11
2.5 Port and Cable
ConnectionCables
10/100M copper connectionCat.3, 4, 5, Cat.5 is recommended
1000M copper connectionCat. 5, 5e, Cat. 5e is recommended
1000M fiber connectionMMF or SMF depending on the SFP transceiver used
2.6 Rack Mounting
Two 19-inch rack mounting brackets are supplied with the switch for 19-inch rack mounting.
The steps to mount the switch onto a 19-inch rack are:
1. Turn the power to the switch off.
2. Install two brackets with supplied screws onto the switch.
2. Mount the switch onto 19-inch rack with rack screws securely.
3. Turn the power to the switch on.
2.7 RESET Button
The reset button is located on the front panel. The button provides the following functions:
OperationFunction
Press the button more than 3 secondRestore the switch back to factory default settings
Press the button less than 3 secondsReboot the switch
2.8 Software Management
It will take about 30 seconds, after that, the switch will flash all the LED once and automatically
performs self-test and is in ready state. The switch features an http server which can serve the management requests coming from any web browser software over internet or intranet network.
Web Browser
• Microsoft IE 6.0 above recommended, Netscape V7.1 above or FireFox V1.00 above
• Display resolution 1024x768.
Set IP Address for the switch unit
Before the switch can be managed from a web browser software, make sure a unique IP address is
configured for the switch.
2.9 IP Address Settings and Changing Password
The switch is shipped with the following factory default settings:
• IP address of the switch : 192.168.1.1
• Subnet Mask of the switch : 255.255.255.0
• Default Gateway of the switch : 192.168.1.254
• Password : admin
For security reason, it is recommended to change the default settings for the switch before deploying it
to your network:
To change IP addressUse Web System Configuration Menu
To change passwordUse Web System Configuration Menu
-11-
Page 12
3. Operation of Web-based Management
The steps to start web management are:
1. Type http://192.168.1.1 in the address row in a browser.
2. Type password in order to login and access authentication. The default password is [admin].
Login
For the first time to use, please enter the default password, then click the <Apply> button.
The login process now is completed.
In the switch, it supports a simple user management function allowing only one administrator to configure the system at the same time.
To optimize the display effect, it is recommended to use :
• Microsoft IE 6.0 above, Netscape V7.1 above or FireFox V1.00 above
• Display resolution 1024x768.
-12-
Page 13
3.1 Web Management Home Overview
The Information of Page Layout
Top side
It shows the front panel of the switch. In the front panel, the linked ports will display green; as to the
ports, which are link off, they will be dark. For the optional modules, the slot will show only a cover
plate if no module exists and will show a module if a module is present. The image of module depends
on the one you inserted. The same, if disconnected, the port will show just dark, if linked, green.
Left side
The main menu tree for web is listed in the page. According to the function name in boldface, all
functions can be divided into three parts, including Configuration, Monitoring and Maintenance. The
functions of each folder are described in its corresponded section respectively. As to the function
names in normal type are the sub-functions. When clicking it, the function is performed.
Right side
This area is used for detailed configuration and status.
The following list is the main function tree for web user interface.
-13-
Page 14
3.2 Configuration
Each of them will be described in detail orderly in the following sections.
-14-
Page 15
3.2.1 System Configuration
The switch supports manual IP address setting. When IP address is changed, you must reboot the
switch to have the setting taken effect and use the new IP to browse for web management.
Parameter description:
MAC AddressIt is the Ethernet MAC address of the management agent in this switch.
Firmware VersionThe firmware version of this switch.
Hardware VersionThe hardware version of this switch.
Serial NumberThe serial number is assigned by the manufacturer.
IP AddressUsers can configure the IP settings and fill in new values. Default:
192.168.1.1
Subnet MaskSubnet mask is used to set the subnet mask value. Default: 255.255.255.0
Default GatewaySet an IP address for a gateway to handle those packets that do not meet
the routing rules predefined in the device. Default: 192.168.1.254
System NameSet a special name for this switch. Up to 16 characters are allowed in this
parameter. Any alphanumeric character and null are acceptable. Default:
Giga Switch
PasswordSet a password for this switch. Up to 16 characters are allowed in this
parameter. Any alphanumeric character is acceptable. Default: admin
Auto Logout TimerSet the auto-logout timer. The valid value is 0 ~ 60 in the unit of minute
and a decimal point is not allowed. The value 0 means auto-logout timer is
disabled. Default: 0
-15-
Page 16
3.2.2 Ports Configuration
Parameter description:
ModeSet the speed and duplex of the port. Speed/Duplex is comprised of the combina-
tion of speed mode, 10/100/1000Mbps, and duplex mode, full duplex and half
duplex. In Auto Speed mode, no default value. In Forced mode, default value
depends on your setting.
Flow ControlThere are two modes to choose in flow control, including Enable and Disable. If
flow control is set Enable, both parties can send PAUSE frame to the transmitting device(s) if the receiving port is too busy to handle. When it is set Disable,
there will be no flow control in the port. It drops the packet if too much to
handle. Default: Enable
-16-
Page 17
3.2.3 VLAN Mode Configuration
The switch supports Port-based VLAN and 802.1Q Tag-based VLAN. Support 24 active VLANs and
VLAN ID 1~4094.
Parameter description:
VLAN ModeDisable - Stop VLAN function on the switch. In this mode, no VLAN is applied
to the switch. This is the default setting.
Port-based - Port-based VLAN is defined by port. No filtering criterion applies
in port-based VLAN. The only criterion is the physical port you connect to.
Tag-based - Tag-based VLAN identifies its member by VID. This is quite
different from port-based VLAN. Each tag-based VLAN you built up must be
assigned VLAN name and VLAN ID. Valid VLAN ID is 1-4094.
Metro Mode - The Metro Mode is a quick configuration VLAN environment
method on Port-based VLAN. It will create 22 or 23 Port-based VLAN groups.
Up-link PortThis function is enabled only when metro mode is chosen in VLAN mode.
23 - Except Port 23, each port of the switch cannot transmit packets with each
other. Each port groups a VLAN with Port 23, thus, total 23 groups consisting of
2 members are formed.
24 - Except Port 24, each port of the switch cannot transmit packets with each
other. Each port groups a VLAN with Port 24, thus, total 23 groups consisting of
2 members are formed.
23&24 - Except Port 23 and Port 24, each port of the switch cannot transmit
packets with each other. Each port groups a VLAN with Port 23 and Port 24,
thus, total 22 groups consisting of 3 members are formed.
This switch can support up to maximal 24 port-based VLAN groups or 24 Tag VLAN groups.
Management Interface:
StateIt works when the tag-based mode is chosen. When this function is enabled, only the
tagged packets with this VID can manage the switch.
VIDValid range 1~4094.
-17-
Page 18
3.2.4 VLAN Group Configuration
It shows the existed information of VLAN Groups List and maintains them, i.e. modify and delete one
of them. You can easily create and delete a VLAN group by pressing <Add Group> and <Delete
Group> function buttons, or click the Group ID directly to edit it.
Parameter description:
ID (Group ID)When you want to edit a VLAN group, you must select the Group ID field.
Then, you will enter Tag-based VLAN Group Setting or Port-based VLAN
Group Setting page, which depends on your VLAN mode selection.
DescriptionThe description defined by administrator is associated with a VLAN group.
VIDVLAN identifier. Each tag-based VLAN group has a unique VID. It appears
only in tag-based mode.
MemberThis is used to enable or disable if a port is a member of the new added VLAN,
[Enable] means it is a member of the VLAN. Just tick the check box (t) beside
the port x to enable it.
<Add Group>Create a new port-based VLAN or tag-based VLAN, which depends on the
VLAN mode you choose in VLAN mode function.
Add a Port-based VLAN group
-18-
Page 19
Add a Tag-based VLAN group
<Delete Group> Just tick the check box (t) beside the ID, then press the <Delete Group> button
to delete the group.
Delete a Port-based VLAN group
Delete a Tag-based VLAN group
-19-
Page 20
3.2.5 PVID Configuration
This configuration is applied to Tag-based VLAN mode only.
Parameter description:
Port 1-24Port number.
PVIDThis PVID range will be 1-4094. Before you set a number x as PVID, you have to
create a Tag-based VLAN group with VID x.
Rule 1Forward only packets with VID matching this port configured VID. You can apply
Rule 1 as a way to a given port to filter unwanted traffic.
Rule 2Drop untagged frame. You can configure a given port to accept all frames (Tagged and
Untagged) or just receive tagged frame.
Note: If Rule 1 is enabled and port 1, for example, receives an untagged packet, the
switch will apply the PVID of port 1 to tag this packet, the packet then will be forwarded. But if the PVID of port 1 is not 100, the packet will be dropped.
TagThis is an egress rule of the port. Here you can choose untag or tag. Tag means the
outgoing packets must carry VLAN tag header, just click the check box. Untag means
the outgoing packets carry no VLAN tag header.
Untag State If you checked this function for a Tag out port, the packet form this port may be tag
out. But, the packet would be untag out if the VID of its tag is the same as the value of
Untag VID while Untag VID state is Enable.
Untag VID Valid range is 0~4094.
-20-
Page 21
3.2.6 Aggregation Configuration
The Aggregation (Port Trunking) Configuration is used to configure the settings of Link Aggregation.
You can bundle more than one port with the same speed, full duplex and the same MAC to be a single
logical port, thus the logical port aggregates the bandwidth of these ports.
Parameter description:
NormalSet up the ports that do not join any aggregation trunking group.
Group 1~8 Group the ports you choose together. Up to 12 ports can be selected for each group.
Note:
Check the following to avoid errors in configuration - When configuring the link aggregation
function, you should check that whether the aggregated ports are in full-duplex mode as well as
their speed is the same or not. The aggregated ports are in the same VLAN group.
-21-
Page 22
3.2.7 Mirror Configuration
Mirror Configuration is to monitor the traffic of the network. For example, we assume that Port A and
Port B are Sniffer Port and Source Port respectively, thus, the traffic passed by Port B will be copied
to Port A for monitoring.
Parameter description:
Sniffer ModeUsed for the activation or deactivation of Port Mirror function, the switch port
mirror supported Ingress traffic only. Default is disable.
Sniffer PortSet up the port for monitoring. Valid port is Port 1~24 and default is Port 1.
Source PortSet up the ports for being monitored. Just tick the check box (t) under the port x
and valid port is Port 1~24.
Note:
When configuring the mirror function, you should avoid setting a port to be a sniffer port and
aggregated port at the same time. It will cause something wrong.
-22-
Page 23
3.2.8 Quality of Service Configuration
Function description:
Default ClassSome packets which did not belong to the selected QoS classifica-
tion method would be classified as Default Class.
[VLAN Tag Priority]In VLAN-tagged packet, there are 3 bits belonging to priority.
According to these 3 bits, we could arrange 8 traffics -0 0 0, 0 0 1, 0
1 0, 0 1 0, 1 0 0, 1 0 1, 1 1 0, 1 1 1. We can set High priority or Low
priority for each traffic class.
[IP ToS Classification]In a received IP packet, TOS field is used to classify the priority
class to which the packet belongs.
[
IP TCP/UDP Port Classification] In a received TCP or UDP packet, the software Port number
associated with the packet is checked and classified for the priority
class. Eight Port numbers can be configured. This option also
supports simple L4 configuration for some popular applications.
[IP Deffserv Classification] In a received IP packet, DiffServ field is used to classify the priority
class to which the packet belongs.
Click one of the QoS classification methods for the switch and click <Apply> to confirm the selection.
Then, click [Configure] for further detailed configuration for the selected classification method.
-23-
Page 24
3.2.8.1 Vlan Tag Configuration
Parameter description:
PortPort 1 ~ Port 24 - User can set up the port (1~24) respectively to let Vlan Tag QoS
function work on them. Multiple port selection is allowed.
All - select all ports (1~24) to simplify the procedure of configuration.
ClassEach priority tag value is configured with a priority class.
High - High Priority
Low - Low priority
Note:
1. Bit 0 Bit 1 Bit 2 represent the 3-bit value in priority tag field.
2. Each port can be configured its own tag values and priority class mapping.
3. Untagged packets are classified with Default Class.
-24-
Page 25
3.2.8.2 IP ToS Classification
Parameter description:
PortPort 1 ~ Port 24 - User can set up the port (1~24) respectively to let IP ToS QoS
Classification function work on them. Multiple port selection is allowed.
All - select all ports (1~24) to simplify the procedure of configuration.
ClassEach ToS value is configured with a priority class.
High - High Priority
Low - Low priority
Note:
Bit 0, Bit 1, Bit 2 represent Bit 5 ~ Bit 7 in TOS Field of IP Header in an IP packet.
-25-
Page 26
3.2.8.3 IP TCP/UDP Port Classification
In L4 QoS Configuration, you can select one of these special network transmission events with the
associated predefined configuration. Or, click <Advanced> to view the detailed configuration and make
change for customizing. The L4 event options are:
• Disable IP TCP/UDP Port Classification
• Down prioritize web browsing, e-mail, FTP and news
• Prioritize IP Telephony (VoIP)
• Prioritize iSCSI
• Prioritize web browsing, e-mail, FTP transfers and news
• Prioritize Streaming Audio/Video
• Prioritize Databases (Oracle, IBM DB2, SQL, Microsoft)
Click one of the options.
<Advance>>>Click Advanced mode to view and modify detailed port number configuration.
<Simple<<>Click to disable display of the detailed port number configuration.
-26-
Page 27
Advanced Mode:
Special TCP/UDP class:
Class assigned to the configured Custom Port numbers
High - High Priority
Low - Low priority
Default class (all other TCP/UDP ports):
The class assigned to the port numbers that are not in the Custom port list.
PortPort 1 ~ Port 24 - User can set up the port (1~24) respectively to let L4 QoS Classifi-
cation function work on them. Multiple port selection is allowed.
All - select all ports (1~24) to simplify the procedure of configuration.
Custom:TCP/UDP port number (Up to 10 custom port numbers can be configured.)
The following figure illustrates the predefined configuration when selecting option of [Down prioritize
web browsing, e-mail, FTP and news] and the port numbers are 80,280,443,25,110,20,21,69,119,2009.
-27-
Page 28
3.2.8.4 IP Diffserv Classification
IP Diffserve Classification method uses 6-bit field of DSCP in an IP packet to classify the priority class
of the received IP packet. Each DSCP (Diffserv value) can be configured a priority class.
Parameter description:
Diffserv:Display 64 (0~63) DSCP items.
Class:Class assigned to the DSCP
High - High Priority
Low - Low priority
Note:
The classification function are applied to all ports and can not be configured for each port
respectively..
-28-
Page 29
3.2.9 Bandwidth Management
Bandwidth Management function is used to set up the limit of Ingress and Egress bandwidth for each
port.
Note:
Each port of the switch owns 16KB packet buffer. The packet buffer size will be reduced when
the bandwidth rate limitation is enabled, which may cause that jumbo frame cannot be forwarded.
Avoid enabling jumbo frame and bandwidth rating functions at the same time.
Ingress Rate Limiting parameter description:
Port Number:Choose the port that you would like this function to work on it. Valid range
of the port is 1~24. Multiple port selection is allowed. [All] means all ports
(Port 1 ~ 24).
All T raffic:Set up the limit of Ingress bandwidth for the selected ports. Incoming
traffic will be discarded if the rate exceeds the value you set up in Data
Rate field. Pause frames are also generated if flow control is enabled. The
format of the packet limits to Unicast, broadcast and multicast.
Data Rate (Mbps):Valid range is 0~1000.
Broadcast & Multicasat:Set up the limit of Ingress bandwidth for the port you choose. Incoming
traffic will be discarded if the rate exceeds the value you set up in Data
Rate field. The format of the packet only limits to broadcast and multicast.
Data Rate (Mbps):Valid range is 0~1000.
Egress Rate Limiting parameter description:
All T raffic:Set up the limit of Egress bandwidth for the port you choose. Packet
transmission will be delayed if the rate exceeds the value you set up in
Data Rate field. Traffic may be lost if egress buffers run full. The format
of the packet limits to Unicast, broadcast and multicast.
Data Rate (Mbps):Valid range is 0~1000.
-29-
Page 30
3.2.10 Trap Event Configuration
The Trap Events Configuration function is used to enable the switch to send out the SNMP trap
information while predefined trap events occurred.
Parameter description:
Trap IP:IP address of the SNMP trap manager who can receive the traps. Two trap managers
are supported.
System Events:
Warm BootWarm Start Management operation event
Cold BootPower on event of the switch
Illegal LoginInvalid login event
Port Events:
Link UpPort link up event
Link DownPort link down event
Rx error thresholdRx error over threshold event
Tx error thresholdTx error over threshold event
Error thresholdThe number of error packets in 5 seconds
This page also displays occurrence counters of some events.
-30-
Page 31
3.2.11 Max. Packet Length
This function is used to limit the maximum packet length accepted by each port.
Jumbo Frame(bytes)Set up the maximum length of the packet that each port can accept.
Options : 1518, 1532, 9216 bytes
The default is 1532 bytes.
-31-
Page 32
3.3 Monitoring
There are two functions contained in the monitoring section.
3.3.1 Statistics Overview
The function of Statistics Overview collects any information and provides the counting summary about
the traffic of the port, no matter the packet is good or bad.
If the counting is overflow, the counter will be reset and restart counting.
Parameters description:
Tx BytesTotal transmitted bytes.
Tx FramesThe counting number of the packet transmitted.
Rx BytesTotal received bytes.
Rx FramesThe counting number of the packet received.
Tx ErrorsNumber of bad packets transmitted.
Rx ErrorsNumber of bad packets received.
-32-
Page 33
3.3.2 Detailed Statistics
Parameter description:
Rx PacketsThe counting number of the packet received.
RX OctetsTotal received bytes.
Rx High Priority Packets Number of Rx packets classified as high priority.
Rx Low Priority PacketsNumber of Rx packets classified as low priority.
Rx BroadcastShow the counting number of the received broadcast packet.
Rx MulticastShow the counting number of the received multicast packet.
Tx PacketsThe counting number of the packet transmitted.
TX OctetsTotal transmitted bytes.
Tx High Priority Packets Number of Tx packets classified as high priority.
Tx Low Priority PacketsNumber of Tx packets classified as low priority.
Tx BroadcastShow the counting number of the transmitted broadcast packet.
Tx MulticastShow the counting number of the transmitted multicast packet.
Rx 64 BytesNumber of 64-byte frames in all packets received.
-33-
Page 34
Rx 65-127 BytesNumber of 65 ~ 126-byte frames in all packets received.
Rx 128-255 BytesNumber of 127 ~ 255-byte frames in all packets received.
Rx 256-511 BytesNumber of 256 ~ 511-byte frames in all packets received.
Rx 512-1023 BytesNumber of 512 ~ 1023-byte frames in all packets received.
Rx 1024-BytesNumber of 1024-max_length-byte frames in all packets received.
Tx 64 BytesNumber of 64-byte frames in all packets transmitted.
Tx 65-127 BytesNumber of 65 ~ 126-byte frames in all packets transmitted.
Tx 128-255 BytesNumber of 127 ~ 255-byte frames in all packets transmitted.
Tx 256-511 BytesNumber of 256 ~ 511-byte frames in all packets transmitted.
Tx 512-1023 BytesNumber of 512 ~ 1023-byte frames in all packets transmitted.
Tx 1024-BytesNumber of 1024-max_length-byte frames in all packets transmitted.
Rx CRC/AlignmentNumber of Alignment errors and CRC error packets received.
Rx UndersizeNumber of short frames (<64 Bytes) with valid CRC.
Rx OversizeNumber of long frames(according to max_length register) with valid CRC.
Rx FragmentsNumber of short frames (< 64 bytes) with invalid CRC.
Rx JabberNumber of long frames with invalid CRC.
Rx DropsFrames dropped due to the lack of receiving buffer.
Tx CollisionsNumber of collisions transmitting frames experienced.
Tx DropsNumber of frames dropped due to excessive collision, late collision, or
frame aging.
Tx FIFO DropsNumber of frames dropped due to the lack of transmitting buffer.
-34-
Page 35
3.4 Maintenance
The functions are supported:
StatusDisplay all configuration and status of the switch
Warm StartPerform a reboot for the switch
Factory Default Restore all settings back to factory default values
Software Update Perform an update to the management firmware of the switch
LogoutPerform a logout from the switch
3.4.1 Status
The status including System Status, TP Port Status, Fiber Port Status, Aggregation, VLAN, Mirror,
Trap Event and Maximum Packet Length are contained in this function folder for port monitor and
management.
-35-
Page 36
Each of them will be described in detail orderly in the following sections.
System Status
Product Name:To show the product name of this device.
Firmware Version:To show the firmware version of this switch.
Hardware Version:To show the hardware version of this switch.
Serial Number:The serial number is assigned by the manufacturer.
IP Address:To show the IP address of this switch.
Subnet Mask:To show the subnet mask of this switch.
Default Gateway:To show the default gateway of this switch.
MAC Address:To show the Ethernet MAC address of this switch.
System Name:To show the special name for this switch.
Auto Logout Timer:To show the setting of auto-logout timer in the web UI.
Ports Status
Port:Display the port number. The number is 1 - 24. Both port 23 and 24 are
optional modules.
Link Status:Link Status will show the current active link speed and duplex. Otherwise,
it shows [Down].
Speed:Display Auto or Forced the speed mode.
Flow Control:Show each port flow control status.
Aggregation
Normal:Display the ports that do not join any aggregation trunking group.
Group 1~8:Display the members of the Group.
VLAN
VLAN Mode:Display Port-based, Tag-based and metro mode, which depends on the
setting in VLAN mode configuration function.
ID:Display the Group ID.
Description:Display the description defined by administrator is associated with a
VLAN group.
VID:Display VLAN identifier. Each tag-based VLAN group has a unique VID.
It appears only in tag-based mode.
Member:Display the port members belonging to each VLAN Group.
Management Interface
StateVLAN Tagging status of the switch management interface
VIDVID used by the switch management interface
-36-
Page 37
Mirror
Sniffer Mode:Display the status the activation or deactivation of Port Mirror function.
Sniffer Port:Display the port for monitoring.
Source Port:Display the port for being monitored.
Trap Event
Trap IPThe IP address of the first Trap manager
Trap IPThe IP address of the second Trap manager
Warm BootTrap event enable setting
Cold BootTrap event enable setting
Illegal LoginTrap event enable setting and counter
Link UpTrap event enable setting and counter
Link DownTrap event enable setting and counter
Rx error thresholdTrap event enable setting and counter
Tx error thresholdTrap event enable setting and counter
Error thresholdSetting
Maximum Packet Length
Jumbo Frame(bytes):Display the settings about the maximum length of the packet that each port
of the switch can accept.
<Refresh>Button to refresh all status
3.4.2 Warm Restart
Warm Start function allows to reboot the switch with the current settings and configuration. After
upgrading software, then you must reboot to have the new configuration taken effect.
Press <Yes> button to confirm warm restart function, and it will take around thirty (30) seconds to
complete the system boot.
-37-
Page 38
3.4.3 Factory Default
Factory Default function can restore settings back to factory default values except the IP address
settings.
Note:
FunctionCurrent IP Address settingsOther settings
Factory Default web commandNo changeFactory default values
Push RESET button less 3 secondsNo changeNo change
Push RESET button for 3 secondsFactory default valuesFactory default values
-38-
Page 39
3.4.4 Software Update
The switch supports the software update function for the user to upgrade the firmware of the switch to
the latest software version.
Click this function and press the <Yes> button, then you will enter next two pages to complete the
software updating procedures. You must complete the updating procedure.
Note:
After pressing <Yes>, if you encounter any problems or you want to quit the updating you must
turn off the power to the switch for more than 5 seconds and turn it on to resume the management operation.
Wait around 5 seconds and then click the <Go> button to enter software update page.
Click the <Browse> button to search for the file on your management host.
Click the <Update> to start the updating.
-39-
Page 40
3.4.5 Logout
Besides the Auto Logout Timer function described in the section of System Configuration, the switch
also allows the user to logout manually by performing the Logout function.
If no action and no key is stroke as well in any function screen more than the minutes you set up in Auto
Logout Timer, the switch will have you logout automatically. Or press the <Logout> button in Logout
function to exit the system manually.
-40-
Loading...