Page 3
The information contained in this document is subject to change without prior notice.Copyright (C) All Rights
Reserved.
TRADEMARKS
Ethernet is a registered trademark of Xerox Corp.
FCC NOTICE
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)
This device may not cause harmful interference, and (2) This device must accept any interference received,
including the interference that may cause undesired operation.
CE NOTICE
Marking by the symbol indicates compliance of this equipment to the EMC directive 2014/30/EU of the
European Community. Such marking is indicative that this equipment meets or exceeds the following technical
standards:
EMC
EN 55032 Class A
CISPR 32
IEC 55024
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6
IEC 61000-4-8
The KGS-1260 is a 12-port industrial managed Gigabit Ethernet switch series which is featured with the
following communication ports:
Eight 10/100/1000Mbps Gigabit copper ports
Four dual-speed SFP slots for 100Base-FX 1000Base-X
One RS-232 console port
1.1 Model Definitions
-6-
Page 7
1.2 Features
Eight 10/100/1000Mbps RJ-45 and four dual-speed SFP slots
All copper ports support auto-negotiation and auto-MDI/MDI-X detection.
Four SFP slots support dual speed for 100BASE-FX and 1000BASE-X SFP transceivers.
Full wire speed forwarding
Supports 802.3x flow control for full-duplex and backpressure for half-duplex
Supports SFP with Digital Diagnostic Monitoring (DDM)
Supports redundant power inputs
Provides fiber Optical Power Alarm (OPA) function
Provides Automatic Laser Shutdown (ALS) function
Management:
- Private MIB for remote boot the device over SNMP
- Private MIB for TFTP firmware update over SNMP
- Private MIB for configuring OPA function
- Private MIB for configuring ALS function
- OPA alarm traps
-7-
Page 8
1.3 LED Indicators
Pin
RS-232 signals
IN/OUT
1, 2, 7, 8
NC
3
RxD
IN
6
TxD
OUT
LED Function
PWR Power status
Mgt. Management status
Port 1~ 8 SPEED LEDs Speed status
Port 1~ 8 LINK LEDs Link & activity status
SFP 9~12 LEDs Speed & link & activity status of SFP port
1.4 Specifications
10/100/1000 Copper Ports (Port 1 ~ Port 8)
Compliance IEEE 802.3 10Base-T, IEEE 802.3u 100Base-TX, IEEE 802.3u 1000Base-T
Connectors Shielded RJ-45 jacks
Pin assignments Auto MDI/MDI-X detection
Configuration Auto-negotiation or software control
Transmission rate 10Mbps, 100Mbps, 1000Mbps
Duplex support Full/Half duplex
Network cable Cat.5 UTP
Dual-speed SFP Slots (Port 9 ~ Port 12)
Compliance IEEE 802.3u 100Base-FX
IEEE 802.3z 1000Base-SX/LX (mini-GBIC)
Connectors SFP for optional SFP type fiber transceivers
Configuration Auto 1000Mbps, Full duplex
MAC Addresses Table 8K entries
Forwarding & filtering Non-blocking, full wire speed
Switching technology Store and forward
Maximum packet length 9.6K bytes
IP Multicast groups 8192 supported
Flow control IEEE 802.3x pause frame base for full duplex operation
Back pressure for half duplex operation
DC IN Terminal Block
Pin assignments
Redundancy Input A & Input B
Power input voltages +12 ~ +60VDC
Power consumption 8.5W max. @24V
Protection Polarity Reversal shutdown
Isolation Power lines vs. frame ground
Alarm Relay Output Terminal Block
Pin assignments 3 terminal contacts (30VDC/1A max. or 120VAC/0.5A max.)
Alarm events Power failure, Specific port link fault (software configured), OPA
RESET
Push Button Short push - System reset
Long push – Restore factory default settings
856BUMechanical
-9-
Page 10
Dimension 140 x 106 x 60 mm (HxDxW)
Housing Enclosed metal with no fan
Mounting Din-rail mounting, Panel mounting (with optional bracket)
860BUEnvironmental
Operating Temperature Typical -40℃ ~ +70℃
Storage Temperature -40℃ ~ +85℃
Relative Humidity 5% ~ 95% non-condensing
MTBF
KGS-1260/G 212K hours
KGS-1260/I 212K hours
Tests and Approvals
FCC Part 15 rule Class A
CE EMC Class A
VCCI Class A
EN 55032 Emission
IEC 55024 Immunity
IEC 61850-3 EMC & environment for power substation (Enhanced model)
IEEE 1613 for power substation (Enhanced model)
LVD, IEC60950-1 Safety
IEC 60068-2-64 Vibration
IEC 60068-2-27 30G Shock test
802.1Q VLAN Ingress 802.1Q tag stripping, Egress 802.1Q tagging (tag insertion)
S-tag tagging (802.1ad double tagging)
OPA Control Configuration
ALS Control Configuration
Maintenance Restore factory default, reboot, firmware update, configuration file save & upload
SNMP Private MIB DDM status, OPA control, ALS control
SNMP Trap Trap events: Boot up, Port link change, OPA trap
Power saving Disable, Link Up, Link Down, Full
-10-
Page 11
1.5 IEC 61850-3 & IEEE 1613
IEC 61850-3
Test
Level
C 6.7.4 / EN 55022
DC IN conducted emission
Class A
C 6.7.4 / EN 55022
LAN conducted emission
Class A
C 6.7.4 / EN 55022
Radiated emission
Class A
C 6.7.3 / IEC 61000-4-2
ESD
+/-15kV Air, +/-8kV Contact
C 6.7.3 / IEC 61000-4-3
RS
10V/m
C 6.7.3 / IEC 61000-4-4
EFT
DC IN & LAN: +/-4kV
C 6.7.3 / IEC 61000-4-5
Surge
DC IN +/-1kV, LAN +/-4kV
C 6.7.3 / IEC 61000-4-6
CS
DC IN & LAN: 10V
C 6.7.3 / IEC 61000-4-8
PFMF
100A/m, 1000A/m
C 6.7.3 / IEC 61000-4-11
AC-DIP
N/A: No AC input in the device
C 6.7.3 / IEC 61000-4-16
LFCS
DC IN & LAN: 30V/300V
C 6.7.3 / IEC 61000-4-17
DC-Ripple
10% of DC IN
C 6.7.3 / IEC 61000-4-18
Damped Oscillatory Wave
DC IN & LAN: +/-2.5kV
C 6.7.3 / IEC 61000-4-29
DC dips and interruption
DC IN 30% 0.1s, 0% 50ms
IEC 61850-3
Test
Specification
C 6.9.3
Dry heat - operational
+70℃, 30%RH, 72hrs
C 6.9.3
Cold – operational
-40℃, 72hrs
C 6.9.3
Change of temperature - operational
-40 ~ +75℃, 3hr, 6 cycles
C 6.9.3
Damp heat - operational
+70℃, 95%RH, 72hrs
KGS-1260/I model has been enhanced and verified with compliance for IEC 61850-3 EMC, environmental and
mechanical requirements and IEEE 1613 requirements for power substations.
IEC 61850-3
IEC 61850-3 defines the general requirements, mainly regarding construction, design and environmental
conditions for utility communication and automation IEDs (intelligent electronic devices) and systems in
power plant and substation environments.
IEEE 1613
IEEE Standard Environmental and Testing Requirements for Communications Networking Devices in Electric
Power Substations
IEC 61850-3 EMC Test Specifications
IEC 61850-3 Environmental Test Specifications
-11-
Page 12
C 6.9.3
Damp heat – steady state
+40℃, 95%RH, 48hrs
C 6.9.3
Humidity
+25℃95%RH 12hrs/
55oC 95%RH 12hrs, 2 cycles
C 6.9.3
Dry heat - storage
+85℃, 30%RH, 96hrs
C 6.9.3
Cold – storage
-40℃, 96hrs
IEC 61850-3
Test
Specification
C 6.10
Vibration – resonant search
Class 2, 1Gn, 1/axis
C 6.10
Vibration – endurance
Class 2, 2Gn, 20/axis
C 6.10
Shock - responds
Class 2, 10Gn, 11ms, 3/axis
C 6.10
Shock - withstand
Class 2, 30Gn, 11ms, 3/axis
C 6.10
Shock – bump
Class 2, 20Gn, 16ms, 1000/axis
C 6.10
Seismic
Class 2, x – 2Gn, y – 1Gn, 10min.
C 6.10
Enclosure protection
Ingress of solid foreign subjects >=2.5mm
IEEE 1613
Test
Level
Clause 4.1
DC rated control power inputs
80% 100% Max. DC IN
Clause 4.2
Ripple on DC power input
10%
Clause 4.3
AC rated control power inputs
N/A: No AC input in the device
Clause 5.2
Dielectric strength
DC IN vs. LAN ports: 2.8kV
Clause 5.3
Impulse voltage
DC IN vs. LAN ports: 1000Vac
Clause 6 / EMC
1Mhz oscillatory wave
DC IN & LAN: +/-2.5kV
Clause 6 / EMC
EFT
DC IN & LAN: +/-4kV
Clause 7 / EMC
RS
10V/m
Clause 8 / EMC
ESD
+/-15kV Air, +/-8kV Contact
IEC 61850-3 Mechanical Test Specifications
IEEE 1613 Test Specifications
-12-
Page 13
2. Installation
Do not service any product except as explained in your system documentation.
Opening or removing covers may expose you to electrical shock.
Only a trained service technician should service components inside these compartments.
If any of the following conditions occur, unplug the product from the electrical outlet and replace the
part or contact your trained service provider:
- The power cable, extension cable, or plug is damaged.
- An object has fallen into the product.
- The product has been exposed to water.
- The product has been dropped or damaged.
- The product does not operate correctly when you follow the operating instructions.
Do not push any objects into the openings of your system. Doing so can cause fire or electric shock by
shorting out interior components.
Operate the product only from the type of external power source indicated on the electrical ratings
label. If you are not sure of the type of power source required, consult your service provider or local
power company.
Since the surface temperature of the device may be higher than 70℃ in range of
the rated operating temperatures, install and operate the product only by authorized
personnel only. Install the product at a restricted area where un-authorized persons
cannot reach.
2.1 Unpacking
The product package contains:
The device unit for Din-rail mounting
QR code label linking to product documentation cloud
2.2 Safety Cautions
To reduce the risk of bodily injury, electrical shock, fire and damage to the product, observe the following
precautions.
-13-
Page 14
2.3 DIN-Rail Mounting
171BIn the product package, a DIN-rail bracket is provided for mounting the switch in an industrial DIN-rail
enclosure.
172BThe steps to mount the switch onto a DIN rail are:
1. 1287BInstall the mounting bracket onto the switch unit as shown below:
2. 1288BAttach bracket to the lower edge of the DIN rail and push the unit upward a little bit until the bracket can
clamp on the upper edge of the DIN rail.
3. 1289BClamp the unit to the DIN rail and make sure it is mounted securely.
-14-
Page 15
KGS-1260/G and KGS-1260/I have the same dimension as follows:
-15-
Page 16
2.4 Panel Mounting
173BThe switch is provided with an optional panel mounting bracket. The bracket supports mounting the switch on
a plane surface securely.
The mounting steps are:
1. 1290BInstall the mounting bracket on the switch unit.
2. 1291BScrew the bracket on the switch unit.
3. 1292BScrew the switch unit on a panel. Three screw locations are shown below:
-16-
Page 17
KGS-1260/G and KGS-1260/I have the same dimension as follows:
-17-
Page 18
2.5 Applying Power
Pin
1
A
DC power input A () terminal
2
A +
DC power input A (+) terminal
3
B
DC power input B () terminal
4
B +
DC power input B (+) terminal
DC Power Terminal Block
For supporting power redundancy, the device is featured with two DC power input interfaces, DC input A and
input B that enable to receive power from two different power sources.
2.5.1 DC power Terminal Block
Connector: European 4P terminal block & plug
DC Power input contacts:
Redundant input A & B
DC power input voltages: +12 ~ +60VDC
Power consumption: 8.5W max. @24V
Power wires: 24 ~ 12AWG (IEC 0.5~2.5mm2)
Wire length: 1 meter max.
Protection: Polarity Reversal shutdown
-18-
Page 19
2.6 Alarm Relay Output
Pin
1
2
Alarm relay output, NO (Normal Open) contacts
Normal: Open, Alarm: Shorted
NO
2
3
Alarm relay output, NC (Normal Close) contacts
Normal: Shorted, Alarm: Open
NC
Alarm relay output is provided for reporting failure events to a remote alarm relay monitoring system. The
replay output is provided with three contacts on a terminal block connector.
Alarm Relay (AR) output pins and logic:
The relay output can connect relay monitoring system. Both of NO and NC logic are provided individually for
logic selection.
Alarm Events
Input power failure
Configured port link fault
OPA alarm
Note:
Be sure the voltage applied on the relay contacts is within the specification of 30VDC/1A max. or
120VAC/0.5A max.
-19-
Page 20
2.7 Reset Button
The reset button is used to perform a reset to the device. It is not used in normal cases and can be used for
diagnostic purpose. If any network hanging problem is suspected, it is useful to push the button to reset the
device without turning off the power. Check whether the network is recovered.
The button can also be used to restore the software configuration settings to factory default values.
The operations are:
Operation Function
Press the button and release during operation Reset & boot up the device. The behavior is
Press the button when boot-up until all LEDs blink. Boot & restore all factory default settings
same as power boot procedure.
-20-
Page 21
3. Making LAN Connections
3.1 10/100/1000 TP Copper Port
The 10/100/1000 TP copper port supports the following connection types and distances:
Network Cables
10BASE-T: 2-pair UTP Cat. 3, 4, 5 , EIA/TIA-568B 100-ohm
100BASE-TX: 2-pair UTP Cat. 5, EIA/TIA-568B 100-ohm
1000BASE-T: 4-pair UTP Cat. 5 or higher (Cat.5e is recommended), EIA/TIA-568B 100-ohm
Link distance: Up to 100 meters for all above
Auto MDI/MDI-X Function
This function allows the port to auto-detect the twisted-pair signals and adapts itself to form a valid MDI to
MDI-X connection with the remote connected device automatically. No matter a straight through cable or
crossover cable are connected, the ports can sense the receiving pair automatically and configure themselves to
match the rule for MDI to MDI-X connection. It simplifies the cable installation.
Auto-negotiation Function
The port is featured with auto-negotiation function and full capability to support connection to any Ethernet
-21-
Page 22
devices. The port performs a negotiation process for the speed and duplex configuration with the connected
device automatically when each time a link is being established. If the connected device is also
auto-negotiation capable, both link partners will come out the best configuration after negotiation process. If
the connected device is incapable in auto-negotiation, the port will sense the speed and use half duplex for the
connection.
3.2 Making Fiber Connection
The SFP slots (FX port) must be installed with an SFP fiber transceiver for making fiber connection. Your
device may come with an SFP transceiver pre-installed when it was shipped.
Installing SFP Fiber Transceiver
To install an SFP fiber transceiver into SFP slot, the steps are:
1. Turn off the power to the device unit.
2. Insert the SFP fiber transceiver into the SFP slot. Normally, a bail is provided for every SFP transceiver.
Hold the bail and make insertion.
3. Until the SFP transceiver is seated securely in the slot, place the bail in lock position.
Dual Speed Support
The SFP slot supports 1000BASE-X based SFP fiber transceivers and 100BASE-FX based SFP fiber
-22-
Page 23
transceivers.
Connecting Fiber Cables
LC connectors are commonly equipped on most SFP transceiver modules. Identify TX and RX connector
before making cable connection. The following figure illustrates a connection example between two fiber
ports:
Make sure the Rx-to-Tx connection rule is followed on the both ends of the fiber cable.
Network Cables
Multimode (MMF) - 50/125, 62.5/125
Single mode (SMF) - 9/125
3.3 Making Console Connection
-23-
Page 24
Pin
RS-232 signals
IN/OUT
1, 2, 7, 8
NC 3
RxD
IN 6 TxD
OUT
4, 5
GND
The connector designed for the console port is RJ-45.
Pin Assignments
Baud Rate information
Baud rate - 115200
Data bits - 8
Parity - None
Stop bit - 1
Flow control – None
-24-
Page 25
3.4 LED Indication
LED
Function
Color
State
Interpretation
PWR
Power
status
Green
ON
The power is supplied to the switch.
OFF
The power is not supplied to the switch.
Mgt
Management status
Green
BLINK
The switch is in initialization and diagnostics.
Yellow
BLINK
Initialization completed with diagnostic error or system error found during normal operation
Green
ON
Initialization completed with no error
Port1 ~ Port 8
SPEED_LED
Port speed status
Green
ON
Speed is 1000Mbps.
Yellow
ON
Speed is 10Mbps or 100Mbps.
LINK_LED
Port link status
Green
ON
Port link is established. (No traffic)
BLINK
Port link is up and there is traffic.
OFF
Port link is down.
Port 9 ~ Port 12
SPEED_LED
Port speed/link
status
Green
ON
A 1000Mbps link is established.
Yellow
ON
A 100Mbps link is established.
BLINK
Activity status
OFF
Port link is down.
-25-
Page 26
4. Manage the Switch
The switches provide the following methods to configure and monitor the switch as follows:
Making out of band telnet CLI management via the console port
Making in-band management via telnet CLI over TCP/IP network
Making in-band management via web interface over TCP/IP network
Making in-band SNMP management over TCP/IP network
4.1 IP Address & Password
The IP Address is an identification of the switch in a TCP/IP network. Each switch should be designated a new
and unique IP address in the network. The switch is shipped with the following factory default settings for
software management:
Default IP address of the switch: 192.168.0.2 / 255.255.255.0
The switch uses local authentication instead of RADIUS authentication with factory defaults.
Fixed Username: admin
Default password:
No password is required with factory default. However, the password is used for local authentication in
accessing to the switch via console, telnet and Http web-based interface. For security reason, it is
recommended to change the default settings for the switch before deploying it to your network.
4.2 Configuring IP Address & Password via console and telnet
[IP Address] setting command is in IP command group.
Refer to “Operation manual for telnet and console management”.
4.3 Configuring IP Address via Web Interface
Start Web Browser
Start your browser software and enter the default IP address of the switch unit to which you want to connect.
The IP address is used as URL for the browser software to search the device.
URL: http:/192.168.0.2/
Login to Switch Unit
When browser software connects to the switch unit successfully, a Login screen is provided for you to login to
the device as the left display below:
Enter the following default values in the login page:
Default username: admin
Default password:
-27-
Page 28
No password is required.
Click OK to login into the switch.
Web Page after a Successful Login
Select [Configuration] -> [System] -> [IP] to configure IP address
-28-
Page 29
Configuration Description
DHCP Client Enable the DHCP client by checking this box.
IP Address Provide the IP address of this switch unit.
IP Mask Provide the IP mask of this switch unit.
IP Router Provide the IP address of the default router for this switch unit.
VLAN ID Provide the managed VLAN ID. The allowed range is 1 through 4095.
DNS Server Provide the IP address of the DNS Server in dotted decimal notation.
DNS Proxy When DNS proxy is enabled, DUT will relay DNS requests to the current configured
Save Click to save the changes.
Reset Click to undo any changes made locally and revert to previously saved values.
Renew Click to renew DHCP. This button is only available if DHCP is enabled.
DNS server on DUT, and reply as a DNS resolver to the client device on the network.
4.4 Reference Manuals for Web, Console, Telnet Management
The following operation manuals are also provided separately for Console, Telnet and Web management:
The manuals describe the detailed commands and information.
-29-
Page 30
4.5 Configuration for SNMP Management
The switch supports SNMP v1, SNMP v2c, and SNMP v3 management. Make sure the related settings are
well-configured for the switch before you start the SNMP management from an SNMP manager.
Using Telnet Interface
The following are available commands in telnet SNMP command group to configure SNMP-related settings:
>SNMP Configuration
>SNMP Mode [enable|disable]
>SNMP Version [1|2c|3]
>SNMP Read Community [<community>]
>SNMP Write Community [<community>]
>SNMP Trap Mode [enable|disable]
>SNMP Trap Version [1|2c|3]
>SNMP Trap Community [<community>]
>SNMP Trap Destination [<ip_addr_string>]
>SNMP Trap IPv6 Destination [<ipv6_addr>]
>SNMP Trap Authentication Failure [enable|disable]
>SNMP Trap Link-up [enable|disable]
>SNMP Trap Inform Mode [enable|disable]
>SNMP Trap Inform Timeout [<timeout>]
>SNMP Trap Inform Retry Times [<retries>]
>SNMP Trap Probe Security Engine ID [enable|disable]
>SNMP Trap Security Engine ID [<engineid>]
>SNMP Trap Security Name [<security_name>]
>SNMP Engine ID [<engineid>]
>SNMP Community Add <community> [<ip_addr>] [<ip_mask>]
>SNMP Community Delete <index>
>SNMP Community Lookup [<index>]
>SNMP User Add <engineid> <user_name> [MD5|SHA] [<auth_password>] [DES] [<priv_password>]
>SNMP User Delete <index>
>SNMP User Changekey <engineid> <user_name> <auth_password> [<priv_password>]
>SNMP User Lookup [<index>]
>SNMP Group Add <security_model> <security_name> <group_name>
>SNMP Group Delete <index>
>SNMP Group Lookup [<index>]
>SNMP View Add <view_name> [included|excluded] <oid_subtree>
- Private OPA function MIB (OPA configuration for the SFP ports)
- Private ALS function MIB (ALS configuration for the SFP ports)
One product MIB file is also available in the product CD for SNMP manager software.
4.6.1 SNMP Traps
In addition to the SNMP standard traps, the device is equipped with private OPA alarm traps.
The traps are:
- Alarm trap – Port TX power lower than the minimal value
- Alarm trap – Port TX power higher than the maximal value
- Normal trap – Port TX power back to normal (higher than the minimal value)
- Normal trap – Port TX power back to normal (lower than the maximal value)
-32-
Page 33
5. Redundant Ring Applications
5.1 Auto Multi-Ring Technology
Auto Multi-Ring Technology was developed especially for switches connected in ring topology which needs
redundant support when any failure occurs in ring. For large network, more than one ring connections are very
common. Auto Multi-Ring Technology implementation can support more than one ring connection within a
switch. It is also able to work with RSTP support concurrently in the switch.
Some basic information is:
Supports up to six rings in one switch
Supports up to 100 member switches in one ring
Provides fast response time than RSTP protocol
Works with RSTP protocol concurrently within one switch
The following figure illustrates a configuration that three redundant rings and one RSTP ring hook on a main
redundant ring. Some switches support two redundant rings concurrently.
-33-
Page 34
The following figure shows one switch is configured to support three redundant rings and one RSTP ring at the
same time.
5.2 Redundant Ring Applications with industrial standard RSTP protocol
It also can be done to support a ring connection using industrial standard RSTP function and establish a backup
path. In case that any link failure occurs, the backup path can link up immediately to recover the network
operation.
-34-